Sebastian Kaule
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sebastian Kaule has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Finja Borowski
Institute for ImplantTechnology and Biomaterials, Friedrich-Barnewitz-Straße 4, Rostock , Germany
3 shared publications - Jan Oldenburg
Kompetenzzentrum für Medizintechnik, Mecklenburg-Vorpommern , Institut für Implantat Technologie und Biomaterialien e.V. , Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemünde , Germany
3 shared publications - Klaus-Peter Schmitz
Institute for ImplantTechnology and Biomaterials e.V., Rostock-Warnemünde, Germany
3 shared publications Michael Stiehm
Institute for ImplantTechnology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock , Germany
3 shared publications- Alper Öner
Department of Cardiology, Rostock University Medical Center, Rostock, Germany
2 shared publications Alper Oener
Department of Cardiology, University Medical Centre , Rostock , Germany
1 shared publication
Latest Publications
- Open Access
- 1 September 2023
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 503-506
Comparison of steady-state and transient flow measurements for the characterization of paravalvular leakage of transcatheter-aortic valve prostheses
Severe aortic valve stenosis has been successfully treated with minimally invasive transcatheter aortic valve replacement (TAVR) for more than 20 years. The therapy is applied to an increasing cohort of patients. Nevertheless, paravalvular leakage (PVL) remains one of the main complications after TAVR implantation reducing safety and efficacy of the implant. To improve TAVR performance, virtual patient cohorts can be used to generate a significant amount of data with biologically varying conditions comparable to clinically realworld data. For this purpose, in silico models need to be established which are used to evaluate the possible occurrence of PVL. When establishing in silico models, the question between simplification to reduce computational effort and still valid information from the model must always be clarified. Thus, we investigated the comparability between steadystate and transient PVL measurements as an input parameter for simulations in virtual cohorts. A clinically established TAVR was implanted into different annulus models and tested in a steady-state back-flow test bench and in a pulse duplicator system. As a result, leakage rates were compared and assumptions for the in silico models were derived. Although the trend of PVL is comparable in steady-state and transient conditions, absolute values differ making it difficult to extract generalized assumptions. Especially when PVL increased, e.g. in a larger implantation diameter or in an imperfect annulus, the variation also increased up to 50% of the measured value.
- 1 September 2023
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 503-506
Open AccessComparison of steady-state and transient flow measurements for the characterization of paravalvular leakage of transcatheter-aortic valve prostheses
Severe aortic valve stenosis has been successfully treated with minimally invasive transcatheter aortic valve replacement (TAVR) for more than 20 years. The therapy is applied to an increasing cohort of patients. Nevertheless, paravalvular leakage (PVL) remains one of the main complications after TAVR implantation reducing safety and efficacy of the implant. To improve TAVR performance, virtual patient cohorts can be used to generate a significant amount of data with biologically varying conditions comparable to clinically realworld data. For this purpose, in silico models need to be established which are used to evaluate the possible occurrence of PVL. When establishing in silico models, the question between simplification to reduce computational effort and still valid information from the model must always be clarified. Thus, we investigated the comparability between steadystate and transient PVL measurements as an input parameter for simulations in virtual cohorts. A clinically established TAVR was implanted into different annulus models and tested in a steady-state back-flow test bench and in a pulse duplicator system. As a result, leakage rates were compared and assumptions for the in silico models were derived. Although the trend of PVL is comparable in steady-state and transient conditions, absolute values differ making it difficult to extract generalized assumptions. Especially when PVL increased, e.g. in a larger implantation diameter or in an imperfect annulus, the variation also increased up to 50% of the measured value.
- Open Access
- 28 February 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 91 (6) , 291-304
Analysis of thrombosis risk of commissural misaligned transcatheter aortic valve prostheses using particle image velocimetry
Due to excellent clinical results, transcatheter aortic valve replacement (TAVR) has evolved to a treatment option for patients with low surgical risk, resulting in an increasing demand for durable heart valve prostheses. Durability of TAVR could be limited by leaflet thrombosis. Thrombus formation in the aortic root is mainly affected by the hemodynamic situation, which is dependent on the positioning of the implant. We investigated the flow field in the aortic root after TAVR implantation by means of particle image velocimetry. To quantify the influence of the implant-position with respect to an alignment or misalignment of the leaflet commissures on the thrombogenic potential, we used a transport equation for residence time (RT) to consider washout behavior. Furthermore, we introduced a shear effect criterion (SIE) to address platelet activation as a measure for a potential thrombus formation. Misaligned implantation of a TAVR resulted in a reversed direction of rotation of the occurring recirculation area. This led to fluid flow with comparable areas of increased relative blood RT (RTaligned: 97.6%, RTmisaligned: 88.0%) and a smaller area of low shear load for the misaligned TAVR (SIEaligned: 57.7%, SIEmisaligned: 3.70%) into the sinus region, indicating a higher potential for thrombus formation.
- 28 February 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 91 (6) , 291-304
Open AccessAnalysis of thrombosis risk of commissural misaligned transcatheter aortic valve prostheses using particle image velocimetry
Due to excellent clinical results, transcatheter aortic valve replacement (TAVR) has evolved to a treatment option for patients with low surgical risk, resulting in an increasing demand for durable heart valve prostheses. Durability of TAVR could be limited by leaflet thrombosis. Thrombus formation in the aortic root is mainly affected by the hemodynamic situation, which is dependent on the positioning of the implant. We investigated the flow field in the aortic root after TAVR implantation by means of particle image velocimetry. To quantify the influence of the implant-position with respect to an alignment or misalignment of the leaflet commissures on the thrombogenic potential, we used a transport equation for residence time (RT) to consider washout behavior. Furthermore, we introduced a shear effect criterion (SIE) to address platelet activation as a measure for a potential thrombus formation. Misaligned implantation of a TAVR resulted in a reversed direction of rotation of the occurring recirculation area. This led to fluid flow with comparable areas of increased relative blood RT (RTaligned: 97.6%, RTmisaligned: 88.0%) and a smaller area of low shear load for the misaligned TAVR (SIEaligned: 57.7%, SIEmisaligned: 3.70%) into the sinus region, indicating a higher potential for thrombus formation.
- Open Access
- 30 January 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 90 (5) , 323-331
Analysis on the effects of hypo-attenuated leaflet thickening on the hemodynamics of transcatheter aortic valve prostheses by means of particle image velocimetry
The minimally invasive therapy for the treatment of aortic valve regurgitation and stenosis, transcatheter aortic valve replacement (TAVR), is an alternative to surgical valve replacement. Promising clinical results led to the consideration of expanding the use of TAVR in younger patients with lower surgical risk. This implies a longer durability of the TAVR. In relation to the durability of the TAVR, thickening of TAVR leaflets, including reduced motion, has been clinically observed. The aim of this study was to analyse the effects of valve leaflet thickening with reduced leaflet kinematics on the hemodynamics. We measured the flow through a TAVR under pulsatile conditions by using phase-resolved particle image velocimetry (PIV). It has been shown that flow conditions alter in a pathological manner in a TAVR replica with thickened leaflets compared with thin leaflets. In detail, shear stress and Reynolds stress increased by up to a factor of two and additionally the washout behaviour was worse for thickened leaflets. This suggests that a thickened valve is at higher risk for platelet activation and aggregation. This could lead to a self-reinforcing process in which the formation of a thickened valve promotes thrombus formation, which in turn promotes further progression of the thickening.
- 30 January 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 90 (5) , 323-331
Open AccessAnalysis on the effects of hypo-attenuated leaflet thickening on the hemodynamics of transcatheter aortic valve prostheses by means of particle image velocimetry
The minimally invasive therapy for the treatment of aortic valve regurgitation and stenosis, transcatheter aortic valve replacement (TAVR), is an alternative to surgical valve replacement. Promising clinical results led to the consideration of expanding the use of TAVR in younger patients with lower surgical risk. This implies a longer durability of the TAVR. In relation to the durability of the TAVR, thickening of TAVR leaflets, including reduced motion, has been clinically observed. The aim of this study was to analyse the effects of valve leaflet thickening with reduced leaflet kinematics on the hemodynamics. We measured the flow through a TAVR under pulsatile conditions by using phase-resolved particle image velocimetry (PIV). It has been shown that flow conditions alter in a pathological manner in a TAVR replica with thickened leaflets compared with thin leaflets. In detail, shear stress and Reynolds stress increased by up to a factor of two and additionally the washout behaviour was worse for thickened leaflets. This suggests that a thickened valve is at higher risk for platelet activation and aggregation. This could lead to a self-reinforcing process in which the formation of a thickened valve promotes thrombus formation, which in turn promotes further progression of the thickening.
- Open Access
- 29 January 2022
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (3) , 189-200
Particle-Image-Velocimetry zur strömungsmechanischen Analyse des thrombogenen Potentials von Transkatheter-Aortenklappenprothesen
Zusammenfassung Die minimalinvasive Implantation einer Transkatheter-Aortenklappenprothese (TAVR) hat sich zur Standardtherapie für Patienten mit schwerer Aortenklappenstenose und erhöhtem Operationsrisiko etabliert. Postoperative Komplikationen, wie die subklinische Klappenthrombose, rufen langfristig eine Funktionsstörung der TAVR hervor, die ohne Revisionstherapie zum Tod des Patienten führen kann. Mit der Abschätzung des Thromboserisikos von TAVR werden strömungsmechanische Mechanismen assoziiert. Die Particle Image Velocimetry (PIV) bietet ein etabliertes Messverfahren zur Bestimmung des Geschwindigkeitsfeldes einer TAVR, aus dem beispielsweise die Verweilzeit von Blut im Umfeld einer TAVR abgeleitet werden kann. Ein traversierbarer stereo-PIV Aufbau, bei dem zwei CMOS-Kameras im 45 ° Winkel zur Lichtschnittebene positioniert wurden, ermöglichte die Detektion von Tracerpartikeln in den relevanten Bereichen im Umfeld des TAVR. Mit einer geeigneten Messkammer, die in die hydraulische Nachbildung eines kardiovaskulären Kreislaufs implementiert wurde, konnte eine quasi-volumetrische Messung des physiologischen Geschwindigkeitsfeldes durchgeführt werden. Dafür wurde anhand radiologischer Daten eine realistische Implantationsumgebung rekonstruiert. Mit einem Blutersatzfluid (NaCl-Glycerin-Gemisch) wurde die normativ (ISO 5840:2021) geforderte kinematische Viskosität von ν = 3,5 cSt realisiert. Phasengetriggerte Aufnahmen ermöglichten die Messung zu definierten Zeitpunkten im kardiologischen Zyklus. Insgesamt ist es gelungen die komplexe Strömungstopologie mit dem dargestellten Messaufbau in allen relevanten Bereichen zu erfassen und damit zukünftig das Thromboserisiko abschätzen zu können.
- 29 January 2022
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 89 (3) , 189-200
Open AccessParticle-Image-Velocimetry zur strömungsmechanischen Analyse des thrombogenen Potentials von Transkatheter-Aortenklappenprothesen
Zusammenfassung Die minimalinvasive Implantation einer Transkatheter-Aortenklappenprothese (TAVR) hat sich zur Standardtherapie für Patienten mit schwerer Aortenklappenstenose und erhöhtem Operationsrisiko etabliert. Postoperative Komplikationen, wie die subklinische Klappenthrombose, rufen langfristig eine Funktionsstörung der TAVR hervor, die ohne Revisionstherapie zum Tod des Patienten führen kann. Mit der Abschätzung des Thromboserisikos von TAVR werden strömungsmechanische Mechanismen assoziiert. Die Particle Image Velocimetry (PIV) bietet ein etabliertes Messverfahren zur Bestimmung des Geschwindigkeitsfeldes einer TAVR, aus dem beispielsweise die Verweilzeit von Blut im Umfeld einer TAVR abgeleitet werden kann. Ein traversierbarer stereo-PIV Aufbau, bei dem zwei CMOS-Kameras im 45 ° Winkel zur Lichtschnittebene positioniert wurden, ermöglichte die Detektion von Tracerpartikeln in den relevanten Bereichen im Umfeld des TAVR. Mit einer geeigneten Messkammer, die in die hydraulische Nachbildung eines kardiovaskulären Kreislaufs implementiert wurde, konnte eine quasi-volumetrische Messung des physiologischen Geschwindigkeitsfeldes durchgeführt werden. Dafür wurde anhand radiologischer Daten eine realistische Implantationsumgebung rekonstruiert. Mit einem Blutersatzfluid (NaCl-Glycerin-Gemisch) wurde die normativ (ISO 5840:2021) geforderte kinematische Viskosität von ν = 3,5 cSt realisiert. Phasengetriggerte Aufnahmen ermöglichten die Messung zu definierten Zeitpunkten im kardiologischen Zyklus. Insgesamt ist es gelungen die komplexe Strömungstopologie mit dem dargestellten Messaufbau in allen relevanten Bereichen zu erfassen und damit zukünftig das Thromboserisiko abschätzen zu können.