    Lumen reconstruction of covered stents for numerical simulation of thrombosis risk

    by Finja Borowski, Stefan Siewert, Klaus-Peter Schmitz, Michael Stiehm, Daniela Koper

    Covered stents are increasingly used in the treatment of aortoiliac occlusions and aneurysms. However, the presence of a polymeric cover may inhibit endothelialization and alter blood flow, potentially increasing the risk of thrombosis. Accurate geometric models of the stent lumen are crucial for computational fluid dynamics (CFD) simulations for thrombosis risk assessment. This study presents a workflow combining silicone casting, μCT imaging, and CFD for thrombosis risk assessment. Applied to a Gore Viabahn VBX stent, the workflow achieved high accuracy with deviations below 0.1mm. CFD simulations identified low wall shear stress regions downstream of cover-induced constrictions, critical for thrombus formation. This approach offers valuable insights for stent design optimization.

  • Open Access

    A fast in silico model for preoperative risk assessment of paravalvular leakage

    by Michelle Spanjaards, Finja Borowski, Laura Supp, René Ubachs, Valentina Lavezzo, Olaf van der Sluis

    In silico simulations can be used to evaluate and optimize the safety, quality, efficacy and applicability of medical devices. Furthermore, in silico modeling is a powerful tool in therapy planning to optimally tailor treatment for each patient. For this purpose, a workflow to perform fast preoperative risk assessment of paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is presented in this paper. To this end, a novel, efficient method is introduced to calculate the regurgitant volume in a simplified, but sufficiently accurate manner. A proof of concept of the method is obtained by comparison of the calculated results with results obtained from in vitro experiments. Furthermore, computational fluid dynamics (CFD) simulations are used to validate more complex stenosis scenarios. Comparing the simplified leakage model to CFD simulations reveals its potential for procedure planning and qualitative preoperative risk assessment of PVL. Finally, a 3D device deployment model and the efficient leakage model are combined to showcase the application of the presented leakage model, by studying the effect of stent size and the degree of stenosis on the regurgitant volume. The presented leakage model is also used to visualize the leakage path. To generalize the leakage model to a wide range of clinical applications, further validation on a large cohort of patients is needed to validate the accuracy of the model’s prediction under various patient-specific conditions.


  • Open Access

    In silico model to assess thrombosis risk of TAVR with hemodynamic predictors using fluid structure interaction

    by Finja Borowski, Sebastian Kaule, Jan Oldenburg, Alper Öner, Klaus-Peter Schmitz, Michael Stiehm

    The promising results of transcatheter aortic valve replacement (TAVR) over the past two decades indicate an expansion of the patient cohort toward patients with intermediate or low surgical risk. Since some complications of TAVR have already been minimized, subclinical leaflet thrombosis (SLT) has gained importance in recent years. SLT is manifested by a thrombotic layer on the prosthetic leaflets that gradually reduces leaflet motion. The resulting decrease in functionality of the TAVR causes a need for re-intervention. The origin of SLT and approaches to prevent SLT are still unexplored. For this reason, we have developed an in silicomodel that can be used during the design development process of TAVR devices to estimate the thrombosis risk of the implant. Based on passive scalar transport, hemodynamic metrics are used to quantify platelet activation and aggregation which are associated with the formation of thrombosis. In conjunction with a numerical simulation model considering the fluid-structure interaction between the blood mimicking fluid and the TAVR implanted in an aortic root, the thrombosis risk can be modeled. The simulation model can be used to calculate the three-dimensional flow structures within the native sinus and neo-sinus and also provides the ability to derive metrics to assess the risk of thrombosis. We demonstrated that this in silicomodel is a time-effective tool to assess thrombosis risk in TAVR product development.


  • Open Access

    Analysis of thrombosis risk of commissural misaligned transcatheter aortic valve prostheses using particle image velocimetry

    by Finja Borowski, Sebastian Kaule, Jan Oldenburg, Klaus-Peter Schmitz, Alper Öner, Michael Stiehm

    Due to excellent clinical results, transcatheter aortic valve replacement (TAVR) has evolved to a treatment option for patients with low surgical risk, resulting in an increasing demand for durable heart valve prostheses. Durability of TAVR could be limited by leaflet thrombosis. Thrombus formation in the aortic root is mainly affected by the hemodynamic situation, which is dependent on the positioning of the implant. We investigated the flow field in the aortic root after TAVR implantation by means of particle image velocimetry. To quantify the influence of the implant-position with respect to an alignment or misalignment of the leaflet commissures on the thrombogenic potential, we used a transport equation for residence time (RT) to consider washout behavior. Furthermore, we introduced a shear effect criterion (SIE) to address platelet activation as a measure for a potential thrombus formation. Misaligned implantation of a TAVR resulted in a reversed direction of rotation of the occurring recirculation area. This led to fluid flow with comparable areas of increased relative blood RT (RTaligned: 97.6%, RTmisaligned: 88.0%) and a smaller area of low shear load for the misaligned TAVR (SIEaligned: 57.7%, SIEmisaligned: 3.70%) into the sinus region, indicating a higher potential for thrombus formation.


  • Open Access

    Analysis on the effects of hypo-attenuated leaflet thickening on the hemodynamics of transcatheter aortic valve prostheses by means of particle image velocimetry

    by Jan Oldenburg, Finja Borowski, Sebastian Kaule, Klaus-Peter Schmitz, Alper Öner, Michael Stiehm

    The minimally invasive therapy for the treatment of aortic valve regurgitation and stenosis, transcatheter aortic valve replacement (TAVR), is an alternative to surgical valve replacement. Promising clinical results led to the consideration of expanding the use of TAVR in younger patients with lower surgical risk. This implies a longer durability of the TAVR. In relation to the durability of the TAVR, thickening of TAVR leaflets, including reduced motion, has been clinically observed. The aim of this study was to analyse the effects of valve leaflet thickening with reduced leaflet kinematics on the hemodynamics. We measured the flow through a TAVR under pulsatile conditions by using phase-resolved particle image velocimetry (PIV). It has been shown that flow conditions alter in a pathological manner in a TAVR replica with thickened leaflets compared with thin leaflets. In detail, shear stress and Reynolds stress increased by up to a factor of two and additionally the washout behaviour was worse for thickened leaflets. This suggests that a thickened valve is at higher risk for platelet activation and aggregation. This could lead to a self-reinforcing process in which the formation of a thickened valve promotes thrombus formation, which in turn promotes further progression of the thickening.


  • Open Access

    Validation of a Fluid Structure Interaction Model for TAVR using Particle Image Velocimetry

    by Finja Borowski, Robert Ott, Jan Oldenburg, Sebastian Kaule, Alper Öner, Klaus-Peter Schmitz, Michael Stiehm

    The implantation of a transcatheter aortic valve replacement (TAVR) in patients with severe aortic stenosis improves pathologic blood flow through the aortic valve, but still alters hemodynamics in comparison to a healthy native aortic valve. The hemodynamic characteristics of TAVR are associated with hypo-attenuating leaflet thickening and prosthetic leaflet thrombosis, which may reduce the durability of TAVR. For this reason we developed a numerical model to identify pro-thrombotic regions of TAVR based on the velocity field. In silico models have already been proven to be an effective tool for device optimization in other medical device applications. However, when using an in silico model, it is important to validate the model assumptions with experimental data or analytical solutions to confirm the accuracy of the model. In this study, we present an approach to validate a complex numerical Fluid Structure Interaction (FSI) model used to simulate leaflet kinematics and flow in the vicinity of a TAVR. Based on the recommendation of ISO 5840 (2021), a combined validation of the kinematic and fluid dynamic parameters was performed for this purpose. The leaflet kinematic was investigated via high-speed recordings and evaluated based on the Geometric Orifice Area (GOA). The velocity field of the TAVR was determined experimentally using Particle Image Velocimetry (PIV). The evaluation of the GOA showed a good agreement of the in silico model with the in vitro data for the systolic duration. The occurring velocities were qualitatively compared during peak systole for three planes and showed similar flow characteristics. The maximum velocity was 1.1 m/s in the in vitro and in silico model. Based on the results, it can be assumed that the numerical FSI model of the TAVR can be used for thrombosis risk assessment.


  • Open Access

    Particle-Image-Velocimetry zur strömungsmechanischen Analyse des thrombogenen Potentials von Transkatheter-Aortenklappenprothesen

    by Finja Borowski, Sebastian Kaule, Jan Oldenburg, Klaus-Peter Schmitz, Alper Öner, Michael Stiehm

    Zusammenfassung Die minimalinvasive Implantation einer Transkatheter-Aortenklappenprothese (TAVR) hat sich zur Standardtherapie für Patienten mit schwerer Aortenklappenstenose und erhöhtem Operationsrisiko etabliert. Postoperative Komplikationen, wie die subklinische Klappenthrombose, rufen langfristig eine Funktionsstörung der TAVR hervor, die ohne Revisionstherapie zum Tod des Patienten führen kann. Mit der Abschätzung des Thromboserisikos von TAVR werden strömungsmechanische Mechanismen assoziiert. Die Particle Image Velocimetry (PIV) bietet ein etabliertes Messverfahren zur Bestimmung des Geschwindigkeitsfeldes einer TAVR, aus dem beispielsweise die Verweilzeit von Blut im Umfeld einer TAVR abgeleitet werden kann. Ein traversierbarer stereo-PIV Aufbau, bei dem zwei CMOS-Kameras im 45 ° Winkel zur Lichtschnittebene positioniert wurden, ermöglichte die Detektion von Tracerpartikeln in den relevanten Bereichen im Umfeld des TAVR. Mit einer geeigneten Messkammer, die in die hydraulische Nachbildung eines kardiovaskulären Kreislaufs implementiert wurde, konnte eine quasi-volumetrische Messung des physiologischen Geschwindigkeitsfeldes durchgeführt werden. Dafür wurde anhand radiologischer Daten eine realistische Implantationsumgebung rekonstruiert. Mit einem Blutersatzfluid (NaCl-Glycerin-Gemisch) wurde die normativ (ISO 5840:2021) geforderte kinematische Viskosität von ν = 3,5 cSt realisiert. Phasengetriggerte Aufnahmen ermöglichten die Messung zu definierten Zeitpunkten im kardiologischen Zyklus. Insgesamt ist es gelungen die komplexe Strömungstopologie mit dem dargestellten Messaufbau in allen relevanten Bereichen zu erfassen und damit zukünftig das Thromboserisiko abschätzen zu können.