RGRun Ze Gao

Run Ze Gao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Run Ze Gao has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    ADDITIVE MANUFACTURING OF PROSTHETIC DEVICES: A SCOPING REVIEW OF CLINICAL OUTCOMES

    by Christopher Bhatla, Matthew Ho, Catherine Devion, Run Ze Gao, Amanda Lee Mayo

    BACKGROUND: Additive manufacturing (3D printing) has been proposed as a means of improving customization, accessibility, and production efficiency in prosthetic fabrication. However, clinical outcomes remain incompletely characterized, with existing evidence limited by heterogeneous study designs, small samples, and inconsistent outcome reporting. OBJECTIVE: To conduct a scoping review to map the available evidence on clinical outcomes of 3D-printed prosthetic devices in individuals with limb loss or congenital limb difference. METHODOLOGY: JBI (formerly Joanna Briggs Institute) methodology and Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines were followed. MEDLINE, Embase, CINAHL, CENTRAL, and Web of Science were searched from inception to December 31, 2025. Studies were eligible if they reported clinical outcomes, assessed using an identifiable method of measurement, for a functional limb prosthesis directly fabricated using additive manufacturing. RESULTS: Of 1,396 records screened, 42 studies were included. Thirty-one (73.8%) were case reports or case series; no randomized controlled trials were identified. Thirty-two studies (76.2%) involved upper-limb prostheses and ten (23.8%) involved transtibial devices. Fused deposition modeling (FDM) was the most reported additive manufacturing method (76.2%). In upper-limb studies without a comparator, participants frequently reported improved gross motor function compared with using no prosthesis, while fine motor performance and device durability were common limitations. Where a conventional device was used as a comparator, findings were mixed rather than uniformly favoring either fabrication approach. In lower-limb studies, gait and patient-reported outcomes were generally comparable between 3D-printed and conventionally fabricated devices. CONCLUSION: The literature describes 3D-printed prostheses being fabricated, fitted, and used across a range of clinical contexts, including for customized and activity-specific designs, but the evidence base remains limited. Future work should prioritize larger comparative studies, longer follow-up, and more standardized outcome assessment to better define the role of additive manufacturing in prosthetic care. Layman's Abstract Prosthetic limbs help people who have lost a limb, or were born with a limb difference, move and carry out everyday activities. Traditionally, prostheses are manually made using techniques that take time, skill, and clinical resources. 3D printing, which builds an object layer by layer from a digital file, has been suggested as a customizable approach to prosthetic fabrication with possible workflow advantages, though it also carries its own trade-offs. It remains unclear how well 3D-printed prostheses work for the people who use them. This review searched multiple databases to identify published studies examining how people experience 3D-printed prosthetic arms or legs, including how well the devices perform, how comfortable they are, and how satisfied users feel. We identified and reviewed 42 relevant studies, most of which were small reports describing only a handful of patients rather than large trials. In arm prosthesis studies, users often reported improvements in everyday tasks compared to using no prosthesis, though fine motor performance and durability were common weaknesses; results were mixed when compared with conventionally made devices. Studies of leg prostheses generally found comparable outcomes between 3D-printed and conventional devices. Overall, the studies describe 3D-printed prostheses being made, fitted, and used in a range of clinical settings, including custom devices made for specific activities, but the evidence base remains limited. Larger, higher-quality studies with longer follow-up and more consistent outcome measures are needed to better define the role of 3D printing in the production of prostheses. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/47836/35342 How To Cite: Bhatla C, Ho M, Devion C, Gao R.Z, Mayo A.L. Additive manufacturing of prosthetic devices: A scoping review of clinical outcomes. Can Prosthet Orthot J. 2026;9(2):5. https://doi.org/10.33137/cpoj.v9i2.47836 Corresponding Author: Dr. Amanda L. Mayo, MD, MHSc, FRCPC, Affiliations: 1) Division of Physical Medicine and Rehabilitation, Department of Medicine, Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada; 2) Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.E-Mail: Amanda.Mayo@sunnybrook.ca ORCID ID: https://orcid.org/0000-0001-7061-2529

  • Open Access

    DEVELOPING A RESEARCH AGENDA IN DIGITAL WORKFLOWS FOR THE FABRICATION OF PROSTHESES AND ORTHOSES

    by Jan Andrysek, Amanda L. Mayo, Calvin C. Ngan, Dan Blocka, Vishal Pendse, Emma Calovini, Elijah Birley, Fae Azhari, Crystal McKay, Dan Dafonseca, et al.

    BACKGROUND: Recent advancements in digital workflows, including the use of 3D printing, are transforming the prosthetics and orthotics (P&O) field. Digital technologies offer opportunities to deliver P&O services that are more efficient by reducing design and fabrication times, are less wasteful through the elimination or reduction of consumables, including plaster, foam and other materials, and are more repeatable by having digitally saved designs. Despite known advantages, the adoption of digital workflows in P&O has been inconsistent, underscoring the need for cross-sector collaboration to guide the field using evidence-informed approaches. OBJECTIVE: To collaborate with key interest groups to identify priority areas for advancing the adoption and implementation of digital workflows in the P&O field. METHODOLOGY: A modified Delphi approach was used to inform the structure of a Canada-wide initiative and involved participation of 79 representatives from key interest groups, including prosthetists, orthotists, technicians, biomedical engineers, researchers, and people with limb absence/difference. Research priorities were identified through online surveys followed by a hybrid meeting during which attendees engaged in small- and large-group discussions to refine and select priorities. RESULTS: Five key digital P&O research priorities were identified: (1) strengthening evidence on device quality and system performance compared to traditional methods; (2) developing economic and reimbursement models to support clinical integration; (3) improving education and training for digital workflows; (4) establishing standardized practice guidelines; and (5) increasing key interest group engagement to better understand user needs and perspectives. While the general components of digital workflows are now broadly understood, future efforts should focus on more specific contexts, and discussions should be more targeted and disaggregated (e.g., by device type, patient population, or care setting) and include experts with context-specific experience. CONCLUSION: This collaboration initiative provides a strategic roadmap for advancing the adoption of digital workflows in the P&O field and supports the development of national collaborations aimed at fostering innovations and evidence-based practice. Layman's Abstract Recent advances in digital technologies, including three-dimensional (3D) printing, are changing how prostheses and orthoses are designed and fabricated. Digital workflows are the processes of using digital technologies to design and create prostheses or orthoses. These approaches may improve prostheses and orthoses care by reducing design and fabrication time, decreasing waste by reducing the use of plaster and other materials, and improving consistency by allowing designs to be digitally stored and reused. Despite these potential benefits, digital workflows are not yet widely used in clinical practice. Barriers such as limited evidence, gaps in education and training, cost and reimbursement challenges, and a lack of shared standards have slowed adoption. To help address these challenges, a Canada-wide initiative was conducted to bring together key interest groups and develop a shared research agenda. Using a structured consensus-building approach, 79 invitees (including prosthetists, orthotists, biomedical engineers, researchers, and people who use prostheses and/or orthoses) contributed through online surveys and a hybrid meeting that included group discussions. Five main research priorities were identified: generating stronger evidence comparing digitally produced prostheses or orthoses with traditionally made devices, improving education and training for digital workflows, developing economic and reimbursement models that support routine clinical use, creating baseline guidelines to promote consistent and safe practices, and increasing engagement with key interest groups to better understand their perspectives and needs. Overall, this work provides a roadmap to guide future initiatives and collaboration, supporting innovation and evidence-informed use of digital workflows in prostheses and orthoses care. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/46848/35280 How To Cite: Andrysek J, Mayo A.L, Ngan C.C, Blocka D, Pendse V, Calovini E, et al. Developing a research agenda in digital workflows for the fabrication of prostheses and orthoses. Can Prosthet Orthot J. 2026;9(2):4. https://doi.org/10.33137/cpoj.v9i2.46848 Corresponding Author: Prof. Jan Andrysek, PhDAffiliation: 1) Bloorview Research Institute, Holland Bloorview Kids Rehabilitation Hospital, Toronto, Ontario, Canada; 2) Institute of Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada.E-Mail: JAndrysek@hollandbloorview.caORCID ID: https://orcid.org/0000-0002-4976-1228

  • Open Access

    Soft, Highly Stretchable Capacitive Strain Sensors for Continuous In-Home Volumetric Monitoring of Breast Cancer Related Lymphedema

    by Nicholas Levinski, Derry Tong, Lavan Sumanan, Jacob Kowalski, Cameron Sjaarda, Run Ze Gao, Carolyn Ren

    Accurate and continuous monitoring of limb volume is critical for the early detection and management of breast-cancer–related lymphedema; however, existing clinical and home-based methods either lack sensitivity to subtle volumetric changes or are impractical for routine use. Here, we present a proof-of-concept wearable limb-volumetric monitoring platform based on soft, highly stretchable capacitive strain sensors (SHSCSS) fabricated via direct-ink-writing (DIW) using interdigitated electrode (IDE) architectures. Parametric IDE design tools and a DIW process workflow were developed to enable continuous-path electrode geometries, minimizing nozzle retractions and improving fabrication yield and print consistency. Electrical–mechanical characterization across three elastomeric substrates identified intexar as the optimal substrate, exhibiting low hysteresis and stable sensing behavior. Bench-top testing using a limb-volume phantom showed a near-linear capacitance response with strong correlation to diameter expansion (R² = 0.97) over the clinically relevant 0–10% range, with predictable nonlinearity observed beyond 15% expansion. The sensors remained functional after 100 cycles loading tests and exhibited mechanical resilience up to 150% elongation. Collectively, these results demonstrate that DIW-fabricated SHSCSSs offer a manufacturable, high-resolution sensing strategy for wearable limb-volume monitoring, supporting decentralized and continuous surveillance of lymphedema.

  • Open Access

    Microfluidic Valve‐Integrated Garment for Smooth Sequential Gradient Mechanotherapy

    by Run Ze Gao, Chen Xi Huang, Drew M. Werbowski, Jacqueline Mary Kormylo, Clark R. Dickerson, Carolyn L. Ren

    Current mechanotherapy systems for at‐home management of lymphedema and deep vein thrombosis are limited by gaps between actuators and bulky electromechanical control units, leading to untreated regions and restricting use to stationary settings. A key bottleneck is that conventional designs require one valve per actuator, causing control unit size and power demand to scale with actuator count. Here, we present a benchtop study on a wearable mechanotherapy system that addresses these challenges through two innovations: (1) a monolithic sheet of overlapping soft fluidic actuators integrated into a garment to eliminate actuator gaps and (2) embedded microfluidic in‐line membrane valves (μIMVs) that dramatically reduce the number of required electromechanical valves. Overlapping actuators by 40% removes pressure gaps between neighboring actuators, enabling smooth, uniform gradient compression. We further demonstrate μIMVs (3.6 × 0.6 mm) integrated directly with actuators and combined with resistance microchannels on a chip to achieve gradient pressure holding (10–20 mbar increments) and rapid, uniform passive deflation (<3 s), overcoming slow‐throughput treatment cycles limitations of valve‐less microchannel designs while maintaining scalability. This miniaturized system enables a smartphone‐sized control unit, supports direct garment integration, and represents a substantial advance toward truly portable, patient‐centric mechanotherapy for circulatory disorders.

  • Soft Dynamic Fluidic Cushion for Pressure Sore Management in Transtibial Prosthetics: A Proof-of-Concept Study

    by Run Ze Gao, Erica J. W. Rossi, Marley E. O'COnnell, Peter S. Lee, Doug Dittmer, Andreas Schirm, Carolyn L. Ren, James Y. Tung

    Objective: Due to volume fluctuations, bony prominences contacting prosthetic sockets are susceptible to skin breakdown due to constant pressure and shear stresses from lateral and vertical displacements throughout gait. A low-profile unloading cushion that can be controlled with a millisecond response to dynamically provide localized socket fit at the fibular head may offer stress relief during gait. Methods: The study presents a low-profile (<0.5 mm thick) dynamic fluidic cushion that can provide targeted cushioning during gait to mitigate high contact pressures at bony prominences while minimizing duration of pressure and shear. The proof-of-concept study comprised benchtop testing using a residual limb model. Results: The dynamic cushion effectively unloaded high pressure caused by the body weights only during the stance phase at the fibular head for up to 80 kg by mitigating and redistributing contact pressures away from the fibular head to the immediately surrounding soft tissues. Results demonstrated that the fibular head peak contact pressure could be reduced by as much as 94% (98 to 6 kPa) with a response time of 250 milliseconds in benchtop tests, fast enough to turn on during stance and off during swing. Conclusion: The proposed dynamic fluidic cushion has the potential to offer unloading during gait to prevent skin damage at pressure-sensitive spots, notably benefiting individuals with complex limb geometries. Significance: We introduce a new method with the potential to be integrated into prosthetist workflows to locally adjust socket fit (e.g., at the fibular head) using elastomer sheets and a handheld heat press.


  • Soft-Rigid Hybrid Revolute and Prismatic Joints Using Multilayered Bellow-Type Soft Pneumatic Actuators: Design, Characterization, and Its Application as Soft-Rigid Hybrid Gripper

    by Peter Seungjune Lee, Cameron Sjaarda, Run Ze Gao, Jacob Dupuis, Maya Rukavina-Nolsoe, Carolyn L. Ren

    Despite the exponentially expanding capabilities of robotic systems with the introduction of soft robotics, the lack of practical considerations in designing and integrating soft robotic components hinders the widespread application of newly developed technology in real life. This study investigates the development and performance evaluation of soft-rigid hybrid (SRH) robotic systems employing multilayered bellow-shaped soft pneumatic actuators (MBSPAs) to overcome the common challenges exclusively exhibited in soft robotics. Specifically, we introduce a unique SRH revolute joint enabled by a single thermoplastic polyurethane-MBSPA and rigid components to tackle the limitations of existing soft pneumatic actuators (SPAs), such as restricted payload capacity, vulnerability to external damages, and lack of resilience against outdoor environment. The proposed SRH system entails rigid components encapsulating to protect the MBSPA throughout the entirety of the desired range of motion, and demonstrates improved displacement efficiency, force output, and resilience against external loads. The rigid components also help to stabilize the axis of motion, fostering high durability and repeatable motion. We also extend this concept to a one-degree of freedom SRH prismatic joint. Finite element method modeling is used to estimate the general actuator performance, facilitating the design of MBSPA with limited material information and bypassing trial and error. The wider application of this research targets delicate object handling in industries such as agriculture, encouraging safe and efficient automated harvesting. The article includes thorough actuator performance characterization including displacement, frequency response, durability with life cycle testing up to 25,000 cycles, force output, stiffness, and power density. Performance comparisons with other SPA are provided. A proof of concept 3-point gripper enabled by the proposed SRH joints is capable of gripping objects of various sizes and shapes, with detailed workspace analysis and demonstration showing the gripper’s versatility. The SRH system presented here lays a robust foundation for the ongoing advancement of soft robotic technology toward real-life applications, unveiling the potential for a future in which robots operate efficiently in the targeted applications, aiming to integrate seamlessly into workflows with human workers.


  • Hybrid Soft-Rigid Active Prosthetics Laboratory Exercise for Hands-On Biomechanical and Biomedical Engineering Education

    by Run Ze Gao, Peter S. Lee, Aravind Ravi, Carolyn L. Ren, Clark R. Dickerson, James Y. Tung

    This paper introduces a hands-on laboratory exercise focused on assembling and testing a hybrid soft-rigid active finger prosthetic for biomechanical and biomedical engineering (BME) education. This hands-on laboratory activity focuses on the design of a myoelectric finger prosthesis, integrating mechanical, electrical, sensor (i.e., inertial measurement units (IMUs), electromyography (EMG)), pneumatics, and embedded software concepts. We expose students to a hybrid soft-rigid robotic system, offering a flexible, modifiable lab activity that can be tailored to instructors' needs and curriculum requirements. All necessary files are made available in an open-access format for implementation. Off-the-shelf components are all purchasable through global vendors (e.g., DigiKey Electronics, McMaster-Carr, Amazon), costing approximately USD 100 per kit, largely with reusable elements. We piloted this lab with 40 undergraduate engineering students in a neural and rehabilitation engineering upper year elective course, receiving excellent positive feedback. Rooted in real-world applications, the lab is an engaging pedagogical platform, as students are eager to learn about systems with tangible impacts. Extensions to the lab, such as follow-up clinical (e.g., prosthetist) and/or technical (e.g., user-device interface design) discussion, are a natural means to deepen and promote interdisciplinary hands-on learning experiences. In conclusion, the lab session provides an engaging journey through the lifecycle of the prosthetic finger research and design process, spanning conceptualization and creation to the final assembly and testing phases.


  • Electronics-Free Soft Robotic Knee Brace for Dynamic Unloading During Gait for Knee Osteoarthritis: A Proof-of-Concept Study

    by Amanda Johnson, Run Ze Gao, Kendal Marriott, Clark R. Dickerson, Monica R. Maly, Carolyn L. Ren

    We present a novel electronics-free soft robotic knee brace which employs a closed-loop fluidic regenerative (CLFR) system for dynamic unloading in unicompartmental tibiofemoral osteoarthritis (OA). The existing dynamic unloaders are bulky, large, and heavy, and have low compliance likely due to the use of an electrical control box, which is eliminated in the CLFR system. The system consists of a commercial unloading knee brace, a spring-loaded bellow inserted under the heel inside a shoe, a soft-fluidic actuator (bladder), and tubing for fluid transfer. The novelty lies in the fact that the user's body weight (self-powered) compresses the bellow to provide energy to inflate the air bladder placed at the knee. As a result, the yielded pressure unloads the undesirable forces due to knee OA during the stance phase of gait while strategically applying no forces during the swing phase. The knee bladder contact pressure/force, the system response time, and the durability were evaluated via contact pressure measurements for six systems with varying bellow volumes and either pneumatic or hydraulic configurations. All systems produced safe pressure outputs for human skin within a tested bodyweight range of 60–90 kg. Pneumatic and hydraulic systems achieved 250 ms and 400 ms pressurization response times, respectively. During cyclic loading, pneumatic and hydraulic systems demonstrated less than 1% and ∼10% pressure loss, respectively. Overall, the CLFR system created a promising electronics-free solution for dynamically unloading the knee during gait, indicating a potential new paradigm for knee braces.


  • Soft robotics–inspired sensing system for detecting downward movement and pistoning in prosthetic sockets: A proof-of-concept study

    by Adam J. Yu, Run Ze Gao, Peter S. Lee, Christian Mele, Doug Dittmer, Andreas Schirm, Carolyn L. Ren, James Y. Tung

    Background: Vertical displacement of the residual limb within transtibial prosthetic socket, often known as “pistoning” or downward movement, may lead to skin breakdowns and ulcers. Downward movement is particularly difficult to self-manage for diabetic individuals living with amputation because of diminished sensation in the residual limb from peripheral neuropathy. Therefore, a customizable sensor at the distal end that can alert the users when high-risk downward movement and pistoning occurs is urgently needed. Objectives: Presented herein for the first time is a lightweight, inexpensive sensing system inspired by soft robotics that can detect the occurrence and severity of downward movement at the distal end. Methods: The sensing system consists of a multilayered torus-shaped balloon, allowing easy integration with pin-lock socket systems. The design allows sensing of vertical displacement without imparting high reaction forces back onto the distal end. A benchtop compression tester was used to characterize system performance. Systematic and parametric benchtop tests were conducted to examine the sensor’s physical characteristics. Long-term (24-h) stability of the sensor was also recorded. Results: Compared with water, air was determined to be a better medium with a higher linear full-scale span (FSS) because of its compressible nature. Repeatable 0.5-mm vertical displacements yielded a linear (>0.99 R2) FSS of 4.5 mm and a sensitivity of 0.8 kPa/mm. The sensing system is highly precise, with as low as 1% FSS total error band and average hysteresis of 2.84% of FSS. Over 24 h, a 4% FSS drift was observed. Conclusion: Sensing system characteristics, coupled with low-cost, customizable fabrication, indicates promising performance for daily use to notify and alert transtibial prosthetic users of downward movement and/or pistoning.


  • Open Access

    Synergizing microfluidics with soft robotics: A perspective on miniaturization and future directions

    by Run Ze Gao, Carolyn L. Ren

    Soft robotics has gone through a decade of tremendous progress in advancing both fundamentals and technologies. It has also seen a wide range of applications such as surgery assistance, handling of delicate foods, and wearable assistive systems driven by its soft nature that is more human friendly than traditional hard robotics. The rapid growth of soft robotics introduces many challenges, which vary with applications. Common challenges include the availability of soft materials for realizing different functions and the precision and speed of control required for actuation. In the context of wearable systems, miniaturization appears to be an additional hurdle to be overcome in order to develop truly impactful systems with a high user acceptance. Microfluidics as a field of research has gone through more than two decades of intense and focused research resulting in many fundamental theories and practical tools that have the potentials to be applied synergistically to soft robotics toward miniaturization. This perspective aims to introduce the potential synergy between microfluidics and soft robotics as a research topic and suggest future directions that could leverage the advantages of the two fields.