PLPeter Seungjune Lee

Peter Seungjune Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peter Seungjune Lee has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Soft Dynamic Fluidic Cushion for Pressure Sore Management in Transtibial Prosthetics: A Proof-of-Concept Study

    by Run Ze Gao, Erica J. W. Rossi, Marley E. O'COnnell, Peter S. Lee, Doug Dittmer, Andreas Schirm, Carolyn L. Ren, James Y. Tung

    Objective: Due to volume fluctuations, bony prominences contacting prosthetic sockets are susceptible to skin breakdown due to constant pressure and shear stresses from lateral and vertical displacements throughout gait. A low-profile unloading cushion that can be controlled with a millisecond response to dynamically provide localized socket fit at the fibular head may offer stress relief during gait. Methods: The study presents a low-profile (<0.5 mm thick) dynamic fluidic cushion that can provide targeted cushioning during gait to mitigate high contact pressures at bony prominences while minimizing duration of pressure and shear. The proof-of-concept study comprised benchtop testing using a residual limb model. Results: The dynamic cushion effectively unloaded high pressure caused by the body weights only during the stance phase at the fibular head for up to 80 kg by mitigating and redistributing contact pressures away from the fibular head to the immediately surrounding soft tissues. Results demonstrated that the fibular head peak contact pressure could be reduced by as much as 94% (98 to 6 kPa) with a response time of 250 milliseconds in benchtop tests, fast enough to turn on during stance and off during swing. Conclusion: The proposed dynamic fluidic cushion has the potential to offer unloading during gait to prevent skin damage at pressure-sensitive spots, notably benefiting individuals with complex limb geometries. Significance: We introduce a new method with the potential to be integrated into prosthetist workflows to locally adjust socket fit (e.g., at the fibular head) using elastomer sheets and a handheld heat press.


  • Soft-Rigid Hybrid Revolute and Prismatic Joints Using Multilayered Bellow-Type Soft Pneumatic Actuators: Design, Characterization, and Its Application as Soft-Rigid Hybrid Gripper

    by Peter Seungjune Lee, Cameron Sjaarda, Run Ze Gao, Jacob Dupuis, Maya Rukavina-Nolsoe, Carolyn L. Ren

    Despite the exponentially expanding capabilities of robotic systems with the introduction of soft robotics, the lack of practical considerations in designing and integrating soft robotic components hinders the widespread application of newly developed technology in real life. This study investigates the development and performance evaluation of soft-rigid hybrid (SRH) robotic systems employing multilayered bellow-shaped soft pneumatic actuators (MBSPAs) to overcome the common challenges exclusively exhibited in soft robotics. Specifically, we introduce a unique SRH revolute joint enabled by a single thermoplastic polyurethane-MBSPA and rigid components to tackle the limitations of existing soft pneumatic actuators (SPAs), such as restricted payload capacity, vulnerability to external damages, and lack of resilience against outdoor environment. The proposed SRH system entails rigid components encapsulating to protect the MBSPA throughout the entirety of the desired range of motion, and demonstrates improved displacement efficiency, force output, and resilience against external loads. The rigid components also help to stabilize the axis of motion, fostering high durability and repeatable motion. We also extend this concept to a one-degree of freedom SRH prismatic joint. Finite element method modeling is used to estimate the general actuator performance, facilitating the design of MBSPA with limited material information and bypassing trial and error. The wider application of this research targets delicate object handling in industries such as agriculture, encouraging safe and efficient automated harvesting. The article includes thorough actuator performance characterization including displacement, frequency response, durability with life cycle testing up to 25,000 cycles, force output, stiffness, and power density. Performance comparisons with other SPA are provided. A proof of concept 3-point gripper enabled by the proposed SRH joints is capable of gripping objects of various sizes and shapes, with detailed workspace analysis and demonstration showing the gripper’s versatility. The SRH system presented here lays a robust foundation for the ongoing advancement of soft robotic technology toward real-life applications, unveiling the potential for a future in which robots operate efficiently in the targeted applications, aiming to integrate seamlessly into workflows with human workers.


  • Hybrid Soft-Rigid Active Prosthetics Laboratory Exercise for Hands-On Biomechanical and Biomedical Engineering Education

    by Run Ze Gao, Peter S. Lee, Aravind Ravi, Carolyn L. Ren, Clark R. Dickerson, James Y. Tung

    This paper introduces a hands-on laboratory exercise focused on assembling and testing a hybrid soft-rigid active finger prosthetic for biomechanical and biomedical engineering (BME) education. This hands-on laboratory activity focuses on the design of a myoelectric finger prosthesis, integrating mechanical, electrical, sensor (i.e., inertial measurement units (IMUs), electromyography (EMG)), pneumatics, and embedded software concepts. We expose students to a hybrid soft-rigid robotic system, offering a flexible, modifiable lab activity that can be tailored to instructors' needs and curriculum requirements. All necessary files are made available in an open-access format for implementation. Off-the-shelf components are all purchasable through global vendors (e.g., DigiKey Electronics, McMaster-Carr, Amazon), costing approximately USD 100 per kit, largely with reusable elements. We piloted this lab with 40 undergraduate engineering students in a neural and rehabilitation engineering upper year elective course, receiving excellent positive feedback. Rooted in real-world applications, the lab is an engaging pedagogical platform, as students are eager to learn about systems with tangible impacts. Extensions to the lab, such as follow-up clinical (e.g., prosthetist) and/or technical (e.g., user-device interface design) discussion, are a natural means to deepen and promote interdisciplinary hands-on learning experiences. In conclusion, the lab session provides an engaging journey through the lifecycle of the prosthetic finger research and design process, spanning conceptualization and creation to the final assembly and testing phases.


  • Soft robotics–inspired sensing system for detecting downward movement and pistoning in prosthetic sockets: A proof-of-concept study

    by Adam J. Yu, Run Ze Gao, Peter S. Lee, Christian Mele, Doug Dittmer, Andreas Schirm, Carolyn L. Ren, James Y. Tung

    Background: Vertical displacement of the residual limb within transtibial prosthetic socket, often known as “pistoning” or downward movement, may lead to skin breakdowns and ulcers. Downward movement is particularly difficult to self-manage for diabetic individuals living with amputation because of diminished sensation in the residual limb from peripheral neuropathy. Therefore, a customizable sensor at the distal end that can alert the users when high-risk downward movement and pistoning occurs is urgently needed. Objectives: Presented herein for the first time is a lightweight, inexpensive sensing system inspired by soft robotics that can detect the occurrence and severity of downward movement at the distal end. Methods: The sensing system consists of a multilayered torus-shaped balloon, allowing easy integration with pin-lock socket systems. The design allows sensing of vertical displacement without imparting high reaction forces back onto the distal end. A benchtop compression tester was used to characterize system performance. Systematic and parametric benchtop tests were conducted to examine the sensor’s physical characteristics. Long-term (24-h) stability of the sensor was also recorded. Results: Compared with water, air was determined to be a better medium with a higher linear full-scale span (FSS) because of its compressible nature. Repeatable 0.5-mm vertical displacements yielded a linear (>0.99 R2) FSS of 4.5 mm and a sensitivity of 0.8 kPa/mm. The sensing system is highly precise, with as low as 1% FSS total error band and average hysteresis of 2.84% of FSS. Over 24 h, a 4% FSS drift was observed. Conclusion: Sensing system characteristics, coupled with low-cost, customizable fabrication, indicates promising performance for daily use to notify and alert transtibial prosthetic users of downward movement and/or pistoning.