Sota Goto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sota Goto has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Hayashi
College of Transdisciplinary Sciences for Innovation Kanazawa University Kanazawa Ishikawa Japan
4 shared publications - Takashi Asahara
Department of Radiological Technology, Faculty of Health Sciences Okayama University Okayama Japan
3 shared publications - Natsumi Kimoto
Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, 1-1-1 Chikushigaoka, Fukuoka, Minami-Ku, 815-8510, Japan
2 shared publications - Rina Nishigami2 shared publications
Ryuji Akino
2 shared publications- Tatsuya Maeda
Graduate School of Medical Sciences, Kanazawa University, Ishikawa, 920-0942, Japan
2 shared publications
Latest Publications
- Open Access
- 26 February 2026
- Published by Elsevier in SSRN Electronic Journal
Development of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays
Active-type radiation dosimeters can measure list-mode datasets related to the measurement time and exposure dose, which contribute to detailed analysis of radiation exposure for patients and clinical staff. The aim of this study is to develop a compact active-type dosimeter based on an optically stimulated luminescence (OSL) system, and to establish a dose measurement procedure for diagnostic X-rays. The proposed dosimeter consists of an OSL sheet made of Al2O3:C and a multi-pixel photon counter (MPPC), and the detector region dimension is 10 mm × 10 mm × 13 mm. List-mode datasets consisting of measurement time and pulse height were recorded. The accumulated signal was analyzed by integrating the pulse-height data, in which the processing for smoothing, recovery-time correction, and counting-loss correction were performed. A dose calibration curve was determined from the integrated signal and reference air kerma measured with an ionization chamber. System performance was evaluated using diagnostic X-ray equipment under various dose rate conditions: a tube voltage of 80 kV, tube currents of 20–160 mA, and an exposure time of 1.0 s. Clinical applicability was also verified under typical exposure conditions for hand (50 kV), abdominal (80 kV), and chest (120 kV) examinations. In the experimental results, it was found that the proposed dosimeter can appropriately measure list-mode datasets and determine the accumulated dose with an accuracy of ±20% for 0.3–10 mGy/s. These findings indicate that the proposed dosimeter can be used for clinical dosimetry during diagnostic X-ray examinations.
- 26 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of an Active-Type Optically Stimulated Luminescence (OSL) Dosimeter for Real-Time Dose Measurement of Diagnostic X-Rays
Active-type radiation dosimeters can measure list-mode datasets related to the measurement time and exposure dose, which contribute to detailed analysis of radiation exposure for patients and clinical staff. The aim of this study is to develop a compact active-type dosimeter based on an optically stimulated luminescence (OSL) system, and to establish a dose measurement procedure for diagnostic X-rays. The proposed dosimeter consists of an OSL sheet made of Al2O3:C and a multi-pixel photon counter (MPPC), and the detector region dimension is 10 mm × 10 mm × 13 mm. List-mode datasets consisting of measurement time and pulse height were recorded. The accumulated signal was analyzed by integrating the pulse-height data, in which the processing for smoothing, recovery-time correction, and counting-loss correction were performed. A dose calibration curve was determined from the integrated signal and reference air kerma measured with an ionization chamber. System performance was evaluated using diagnostic X-ray equipment under various dose rate conditions: a tube voltage of 80 kV, tube currents of 20–160 mA, and an exposure time of 1.0 s. Clinical applicability was also verified under typical exposure conditions for hand (50 kV), abdominal (80 kV), and chest (120 kV) examinations. In the experimental results, it was found that the proposed dosimeter can appropriately measure list-mode datasets and determine the accumulated dose with an accuracy of ±20% for 0.3–10 mGy/s. These findings indicate that the proposed dosimeter can be used for clinical dosimetry during diagnostic X-ray examinations.
- Open Access
- 9 November 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 184
Helpfulness of effective atomic number image in forensic dental identification: Photon-counting computed tomography is suitable
- 9 November 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 184
Open AccessHelpfulness of effective atomic number image in forensic dental identification: Photon-counting computed tomography is suitable
- 5 December 2022
- Published by Elsevier in Radiation Measurements
- Vol. 160
Signal-stabilized Al2O3:C-OSL dosimeter “checking chip” for correcting OSL reader sensitivity variation
- 5 December 2022
- Published by Elsevier in Radiation Measurements
- Vol. 160
Signal-stabilized Al2O3:C-OSL dosimeter “checking chip” for correcting OSL reader sensitivity variation
- 16 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Idea for Preparing the Stabilizing Optically Stimulated Luminescence (OSL) Dosimeter Having Smaller Signal Depletion
We plan to apply Optically Stimulated Luminescence (OSL) dosimeters to the quality assessment of delivered dose from a clinical linear accelerator (linac). To manage the output dose appropriately, it is important to measure the absorbed dose to water with high accuracy. There is an issue of sensitivity variation of commercially available OSL dosimeter reading devices with uncertainty being the major component of concern. Previously, a monitoring method to solve this issue was proposed, but this conventional method is too complex to use in clinical facilities. This is because signal instability of an OSL dosimeter, which is used as a monitoring dosimeter, should also be corrected. In order to establish a simple monitoring method, we focused our attention on the development of a signal-stabilized dosimeter for use as a monitoring dosimeter. This study aims to propose a novel idea for processing the dosimeter leading to less signal depletion after multiple readings. Our idea to reduce the number of electrons trapped at the shallow energy level, which is the cause of signal depletion, is to perform partial bleaching on the commercial dosimeter after irradiating at a high dose. OSL dosimeters were prepared under several conditions first we used irradiation doses of 10 and 50 Gy and then exposure to visible light for 0, 10, 30, and 60 seconds. After processing, the OSL signals were read out using a commercial reader, and the signal depletion rate and statistical uncertainty were analyzed. When comparing the results for 10 Gy and 50 Gy, the statistical uncertainty became smaller after irradiating at a high dose. From the results of different bleaching times, we found that signal depletion rate related to one reading can be reduced by partial bleaching; however statistical uncertainty became larger with increased bleaching time. When performing 50 Gy irradiation at 30-second bleaching times, we can prepare a dosimeter having good characteristics of signal depletion rate of -0.007 % and statistical uncertainty of 0.33 %.
- 16 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Idea for Preparing the Stabilizing Optically Stimulated Luminescence (OSL) Dosimeter Having Smaller Signal Depletion
We plan to apply Optically Stimulated Luminescence (OSL) dosimeters to the quality assessment of delivered dose from a clinical linear accelerator (linac). To manage the output dose appropriately, it is important to measure the absorbed dose to water with high accuracy. There is an issue of sensitivity variation of commercially available OSL dosimeter reading devices with uncertainty being the major component of concern. Previously, a monitoring method to solve this issue was proposed, but this conventional method is too complex to use in clinical facilities. This is because signal instability of an OSL dosimeter, which is used as a monitoring dosimeter, should also be corrected. In order to establish a simple monitoring method, we focused our attention on the development of a signal-stabilized dosimeter for use as a monitoring dosimeter. This study aims to propose a novel idea for processing the dosimeter leading to less signal depletion after multiple readings. Our idea to reduce the number of electrons trapped at the shallow energy level, which is the cause of signal depletion, is to perform partial bleaching on the commercial dosimeter after irradiating at a high dose. OSL dosimeters were prepared under several conditions first we used irradiation doses of 10 and 50 Gy and then exposure to visible light for 0, 10, 30, and 60 seconds. After processing, the OSL signals were read out using a commercial reader, and the signal depletion rate and statistical uncertainty were analyzed. When comparing the results for 10 Gy and 50 Gy, the statistical uncertainty became smaller after irradiating at a high dose. From the results of different bleaching times, we found that signal depletion rate related to one reading can be reduced by partial bleaching; however statistical uncertainty became larger with increased bleaching time. When performing 50 Gy irradiation at 30-second bleaching times, we can prepare a dosimeter having good characteristics of signal depletion rate of -0.007 % and statistical uncertainty of 0.33 %.