STSashank Thapa
Sashank Thapa
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sashank Thapa has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Khushmeet Kumar
Department of Mechanical Engineering, Baddi University of Emerging Sciences and Technology, Baddi 173205, India
4 shared publications - Raj Kumar
Department of Mechanical Engineering, Gachon University, Seongnam, South Korea
4 shared publications Sushant Samir
3 shared publications- Tej Singh
Faculty of Informatics, ELTE Eötvös Loránd University, 1117 Budapest, Hungary
3 shared publications Deoraj Prajapati
2 shared publicationsRaj Kumar
2 shared publications
Latest Publications
- Open Access
- 20 November 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 76
Impact of roughness parameters on heat transfer and fluid flow behaviour of solar thermal air collector: CFD-based analysis
- 20 November 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 76
Open AccessImpact of roughness parameters on heat transfer and fluid flow behaviour of solar thermal air collector: CFD-based analysis
- Open Access
Solar Thermal Collector Roughened with S-Shaped Ribs: Parametric Optimization Using AHP-MABAC Technique
The current examination used a multi-criteria decision-making (MCDM) approach to optimize the roughness parameters of S-shaped ribs (SSRs) in a solar thermal collector (STC) duct using air as the working fluid. Different SSRs were tested to identify the combination of parameters resulting in the best performance. Geometrical parameters such as relative roughness pitch () varied from 4 to 12, relative roughness height () from 0.022 to 0.054, arc angle () from 30° to 75°, and relative roughness width () from 1 to 4. The Nusselt number () and friction factor (), findings which impact the STC performance, rely on SSRs. The performance measurements show that no combination of SSR parameters lead to the best enhancement heat transfer rate at low enhancement in the friction. So, a hybrid multi-criteria decision-making strategy using the Analytical Hierarchy Process (AHP) for criterion significance and Multi Attributive Border Approximation Area Comparison (MABAC) for alternative ranking was used to determine which combination of geometrical parameters will result in the optimum performance of a roughened STC. This work employs a hybrid MCDM technique to optimise the effectiveness of an STC roughened with SSRs. To optimize the SSR design parameters, this study used the hybrid AHP-MABAC technique for analytical assessment of a roughened STC. The optimization results showed that the STC roughened with SSRs achieved the optimum performance at = 8, = 0.043, = 60° and = 3.Open AccessSolar Thermal Collector Roughened with S-Shaped Ribs: Parametric Optimization Using AHP-MABAC Technique
The current examination used a multi-criteria decision-making (MCDM) approach to optimize the roughness parameters of S-shaped ribs (SSRs) in a solar thermal collector (STC) duct using air as the working fluid. Different SSRs were tested to identify the combination of parameters resulting in the best performance. Geometrical parameters such as relative roughness pitch () varied from 4 to 12, relative roughness height () from 0.022 to 0.054, arc angle () from 30° to 75°, and relative roughness width () from 1 to 4. The Nusselt number () and friction factor (), findings which impact the STC performance, rely on SSRs. The performance measurements show that no combination of SSR parameters lead to the best enhancement heat transfer rate at low enhancement in the friction. So, a hybrid multi-criteria decision-making strategy using the Analytical Hierarchy Process (AHP) for criterion significance and Multi Attributive Border Approximation Area Comparison (MABAC) for alternative ranking was used to determine which combination of geometrical parameters will result in the optimum performance of a roughened STC. This work employs a hybrid MCDM technique to optimise the effectiveness of an STC roughened with SSRs. To optimize the SSR design parameters, this study used the hybrid AHP-MABAC technique for analytical assessment of a roughened STC. The optimization results showed that the STC roughened with SSRs achieved the optimum performance at = 8, = 0.043, = 60° and = 3. - Open Access
- 17 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (6) , 3527
Assessment of the Thermo-Hydraulic Efficiency of an Indoor-Designed Jet Impingement Solar Thermal Collector Roughened with Single Discrete Arc-Shaped Ribs
This study illustrates the impact of single discrete arc-shaped ribs (SDASR)-type artificial roughness on the performance of a jet impingement solar thermal collector (JISTC). The impact of parametric variations of SDASR on the Nusselt number , friction factor , and thermohydraulic performance is examined. The spacer length () of the SDASR was changed from 0 mm to 300 mm in stages of 100 mm during the experiment. The fixed parameters of the SDASR were a relative discrete distance of 0.67, relative discrete width of 0.87, relative rib height of 0.047, relative rib pitch of 1.7, angle of an arc of 60°, jet diameter ratio of 0.065, streamwise pitch ratio of 1.72, and spanwise pitch ratio of 0.82. The Reynolds number was altered from 3000 to 19,000. The and of a JISTC with a roughened absorber plate was found to be enhanced by 5.25 and 5.98 times as compared to an STC without artificial roughness. The optimal findings of , and were achieved at = 0 mm. The maximum value of the obtained at = 0 mm was 2.9.- 17 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (6) , 3527
Open AccessAssessment of the Thermo-Hydraulic Efficiency of an Indoor-Designed Jet Impingement Solar Thermal Collector Roughened with Single Discrete Arc-Shaped Ribs
This study illustrates the impact of single discrete arc-shaped ribs (SDASR)-type artificial roughness on the performance of a jet impingement solar thermal collector (JISTC). The impact of parametric variations of SDASR on the Nusselt number , friction factor , and thermohydraulic performance is examined. The spacer length () of the SDASR was changed from 0 mm to 300 mm in stages of 100 mm during the experiment. The fixed parameters of the SDASR were a relative discrete distance of 0.67, relative discrete width of 0.87, relative rib height of 0.047, relative rib pitch of 1.7, angle of an arc of 60°, jet diameter ratio of 0.065, streamwise pitch ratio of 1.72, and spanwise pitch ratio of 0.82. The Reynolds number was altered from 3000 to 19,000. The and of a JISTC with a roughened absorber plate was found to be enhanced by 5.25 and 5.98 times as compared to an STC without artificial roughness. The optimal findings of , and were achieved at = 0 mm. The maximum value of the obtained at = 0 mm was 2.9. - Open Access
- 1 January 2022
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 61 (1) , 481-491
Impact of artificial roughness variation on heat transfer and friction characteristics of solar air heating system
- 1 January 2022
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 61 (1) , 481-491
Open AccessImpact of artificial roughness variation on heat transfer and friction characteristics of solar air heating system
- 1 January 2021
- Published by Elsevier in Materials Today: Proceedings
- Vol. 45, 5097-5101
Effect of heat treatment processes on the mechanical properties of AISI 1045 steel
- 1 January 2021
- Published by Elsevier in Materials Today: Proceedings
- Vol. 45, 5097-5101
Effect of heat treatment processes on the mechanical properties of AISI 1045 steel