George Nyauma Nyakoe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
George Nyauma Nyakoe has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Cyrus Wekesa
School of Engineering, University of Eldoret, Eldoret, Kenya.
6 shared publications - Christopher Maina Muriithi
Dept. of Electrical and Electronics Engineering, Murang'a University of Technology, Murang'a, Kenya
4 shared publications - Dessalegn Bitew Aeggegn
Department of Electrical and Computer Engineering, Debre Markos University, Debre Markos, Ethiopia
3 shared publications - Engidaw Abel Hailu
Pan African University Institute for Basic Sciences, Technology, and Innovation, Juja, Kenya
2 shared publications - Yalew Gebru Werkie2 shared publications
- Aloys Oriedi Akumu
Dept. of Electrical Engineering, Tshwane University of Technology, eMalahleni Campus, 1034, South Africa
1 shared publication
Latest Publications
- Open Access
- 21 March 2026
- Published by Elsevier in Energy Reports
- Vol. 15
Optimal UPFC deployment for voltage stability enhancement: Application of weighted voltage stability indices and hybrid optimization
- 21 March 2026
- Published by Elsevier in Energy Reports
- Vol. 15
Open AccessOptimal UPFC deployment for voltage stability enhancement: Application of weighted voltage stability indices and hybrid optimization
- Open Access
- 1 January 2025
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2025 (1)
Power System Voltage Stability Assessment and Control Strategies: State‐of‐the‐Art Review
Voltage stability is crucial for power systems, ensuring that electrical grids maintain voltages within acceptable limits with increasing demand, renewable energy integration, and changing network topology. This paper reviews the voltage stability phenomena, voltage stability indices (VSIs) (line and bus), and offline/online voltage stability assessment considering load variations, uncertain renewable energy, and network structures. Multiple VSIs and algorithms quantify voltage stability, providing information on the system’s resilience to disruptions. A systematic review encompassing the essential aspects of mathematical formulation, expressions, constraints, and applicability of VSIs is presented. Also discussed is the voltage stability control strategy employing flexible AC transmission system (FACTS) devices, considering the incorporation of the power generated from renewable resources. A comparison of voltage stability analysis methodologies is performed. The study offers power system researchers and practitioners a comprehensive summary of voltage stability assessment methods and control strategies for integrating various FACTS devices with renewable energy sources. Finally, the challenges and limitations of voltage stability assessment and control are discussed, as are further research directions.
- 1 January 2025
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2025 (1)
Open AccessPower System Voltage Stability Assessment and Control Strategies: State‐of‐the‐Art Review
Voltage stability is crucial for power systems, ensuring that electrical grids maintain voltages within acceptable limits with increasing demand, renewable energy integration, and changing network topology. This paper reviews the voltage stability phenomena, voltage stability indices (VSIs) (line and bus), and offline/online voltage stability assessment considering load variations, uncertain renewable energy, and network structures. Multiple VSIs and algorithms quantify voltage stability, providing information on the system’s resilience to disruptions. A systematic review encompassing the essential aspects of mathematical formulation, expressions, constraints, and applicability of VSIs is presented. Also discussed is the voltage stability control strategy employing flexible AC transmission system (FACTS) devices, considering the incorporation of the power generated from renewable resources. A comparison of voltage stability analysis methodologies is performed. The study offers power system researchers and practitioners a comprehensive summary of voltage stability assessment methods and control strategies for integrating various FACTS devices with renewable energy sources. Finally, the challenges and limitations of voltage stability assessment and control are discussed, as are further research directions.
- Open Access
- 12 December 2024
- Published by Elsevier in Energy Reports
- Vol. 13, 286-302
An Energy Management System for Multi-Microgrid system considering uncertainties using multi-objective multi-verse optimization
- 12 December 2024
- Published by Elsevier in Energy Reports
- Vol. 13, 286-302
Open AccessAn Energy Management System for Multi-Microgrid system considering uncertainties using multi-objective multi-verse optimization
- Open Access
- 17 June 2024
- Published by Elsevier in Results in Engineering
- Vol. 23
Optimal sizing of grid connected multi-microgrid system using grey wolf optimization
- 17 June 2024
- Published by Elsevier in Results in Engineering
- Vol. 23
Open AccessOptimal sizing of grid connected multi-microgrid system using grey wolf optimization
- Open Access
- 1 January 2024
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2024 (1)
ANFIS‐Controlled Boost and Bidirectional Buck‐Boost DC‐DC Converters for Solar PV, Fuel Cell, and BESS‐Based Microgrid Application
DC‐DC converters are essential for integrating distributed energy resources into microgrid (MG) systems. These converters are designed to incorporate intermittent renewable energy sources such as solar photovoltaic (PV) panels, fuel cells (FCs), and battery energy storage systems (BESSs) into the grid. However, conventional DC‐DC converters have limitations including lower efficiency, voltage ripple, insufficient voltage regulation, and compatibility issues. This article presents boost and bidirectional buck‐boost converters for direct current microgrid (DCMG) applications, employing an adaptive neuro‐fuzzy inference system (ANFIS) for control. These proposed converter configurations adeptly manage wide input voltage fluctuations from intermittent sources, consistently supplying power to the DC bus at 500 V and 120 V for boost and buck operations, respectively, with an efficiency of 98.8%. The output voltage result shows that the ANFIS‐based boost converter has 10% overshoot as compared to 41% and 50% overshoot in proportional integral (PI) and fuzzy logic controller (FLC), respectively. In both buck and boost modes, the converters’ voltage gain is influenced by duty ratio adjustments only, not sensitive to dynamic input voltage and flexible manipulation of the output voltage for BESS charging. Moreover, the designed converters accommodate load variations within the MG. To assess the converters’ ability to regulate output voltage effectively, PI, FLC, and ANFIS controllers are implemented and compared. And the ANFIS controller demonstrates superior performance, offering faster response times and enhanced stability. Evaluations are conducted through simulations in the MATLAB/Simulink environment.
- 1 January 2024
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2024 (1)
Open AccessANFIS‐Controlled Boost and Bidirectional Buck‐Boost DC‐DC Converters for Solar PV, Fuel Cell, and BESS‐Based Microgrid Application
DC‐DC converters are essential for integrating distributed energy resources into microgrid (MG) systems. These converters are designed to incorporate intermittent renewable energy sources such as solar photovoltaic (PV) panels, fuel cells (FCs), and battery energy storage systems (BESSs) into the grid. However, conventional DC‐DC converters have limitations including lower efficiency, voltage ripple, insufficient voltage regulation, and compatibility issues. This article presents boost and bidirectional buck‐boost converters for direct current microgrid (DCMG) applications, employing an adaptive neuro‐fuzzy inference system (ANFIS) for control. These proposed converter configurations adeptly manage wide input voltage fluctuations from intermittent sources, consistently supplying power to the DC bus at 500 V and 120 V for boost and buck operations, respectively, with an efficiency of 98.8%. The output voltage result shows that the ANFIS‐based boost converter has 10% overshoot as compared to 41% and 50% overshoot in proportional integral (PI) and fuzzy logic controller (FLC), respectively. In both buck and boost modes, the converters’ voltage gain is influenced by duty ratio adjustments only, not sensitive to dynamic input voltage and flexible manipulation of the output voltage for BESS charging. Moreover, the designed converters accommodate load variations within the MG. To assess the converters’ ability to regulate output voltage effectively, PI, FLC, and ANFIS controllers are implemented and compared. And the ANFIS controller demonstrates superior performance, offering faster response times and enhanced stability. Evaluations are conducted through simulations in the MATLAB/Simulink environment.
- Open Access
- 30 March 2023
- Published by FOREX Publication in International Journal of Electrical and Electronics Research
- Vol. 11 (1) , 44-53
A Novel Congestion Control Scheme using Firefly Algorithm Optimized Fuzzy-PID Controller in Wireless Sensor Network
In this study, a microstrip antenna is created utilizing a substrate made of jeans. It works between 2.4 to 2.5 GHz in the ISM (industrial, scientific, and medical) band. High-frequency structure simulator (HFSS) software was used to simulate two antennas, one with an incomplete and the other with a complete ground plane. Wearable antennas can protect the body from the impacts of RF radiation by utilizing the entire ground plane principle
- 30 March 2023
- Published by FOREX Publication in International Journal of Electrical and Electronics Research
- Vol. 11 (1) , 44-53
Open AccessA Novel Congestion Control Scheme using Firefly Algorithm Optimized Fuzzy-PID Controller in Wireless Sensor Network
In this study, a microstrip antenna is created utilizing a substrate made of jeans. It works between 2.4 to 2.5 GHz in the ISM (industrial, scientific, and medical) band. High-frequency structure simulator (HFSS) software was used to simulate two antennas, one with an incomplete and the other with a complete ground plane. Wearable antennas can protect the body from the impacts of RF radiation by utilizing the entire ground plane principle
- Open Access
Techniques of power system static security assessment and improvement: A literature survey
- Open Access
- 23 September 2022
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2022, 1-19
Application of Data-Driven Tuned Fuzzy Inference System for Static Equivalencing of Power Systems with High Penetration of Renewable Energy
To reduce the complexity of multiarea power systems during power flow study and security assessment, equivalencing of external power systems is essential. In this paper, external power systems are modeled as adaptive loads representing the tie-line flows varying with system operating conditions. The fuzzy inference system tuned by hybrid genetic-simulated annealing (HGSA-FIS) is proposed to predict the active and reactive power of adaptive loads from forecasted renewable energy (RE) generation and loads demand. The performance of proposed equivalent has been evaluated with an RTS-GMLC by comparing the power flow results in the internal system before and after equivalencing under varying RE and load demand scenarios. The results demonstrate the robustness of HGSA-FIS-based equivalent under varying RE generation and load demand. Furthermore, the proposed equivalent performs close to ANN-based equivalent and outperforms ANFIS-based equivalent. To practically implement the proposed approach, the neighboring system operators are required to exchange only the forecast data of RE generation and load demand, and the equivalent needs to be updated upon major grid changes.
- 23 September 2022
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2022, 1-19
Open AccessApplication of Data-Driven Tuned Fuzzy Inference System for Static Equivalencing of Power Systems with High Penetration of Renewable Energy
To reduce the complexity of multiarea power systems during power flow study and security assessment, equivalencing of external power systems is essential. In this paper, external power systems are modeled as adaptive loads representing the tie-line flows varying with system operating conditions. The fuzzy inference system tuned by hybrid genetic-simulated annealing (HGSA-FIS) is proposed to predict the active and reactive power of adaptive loads from forecasted renewable energy (RE) generation and loads demand. The performance of proposed equivalent has been evaluated with an RTS-GMLC by comparing the power flow results in the internal system before and after equivalencing under varying RE and load demand scenarios. The results demonstrate the robustness of HGSA-FIS-based equivalent under varying RE generation and load demand. Furthermore, the proposed equivalent performs close to ANN-based equivalent and outperforms ANFIS-based equivalent. To practically implement the proposed approach, the neighboring system operators are required to exchange only the forecast data of RE generation and load demand, and the equivalent needs to be updated upon major grid changes.
- 14 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 324-329
A Fuzzy Controlled Pitch Angle in a Permanent Magnet Synchronous Generator Type Wind Energy Conversion System
Controlling technique of the pitch angle is an efficient mechanism to control the mechanical torque of the wind turbine system during a strong wind beyond the rated operating wind speed of the turbine. To control the pitch angle, we have to choose generator’s electrical power, rotor speed, wind speed, and the turbine power coefficient as control parameters. In this article, a pitch angle controller based on fuzzy logic is introduced using the PMSG power as a control variable and wind speed as a sensitivity parameter to improve the control performance of the controller. The fuzzy logic controller is designed and its effectiveness is compared to the PI controller and fixed pitch angle control mechanisms. The simulation result shows that the fuzzy logic pitch angle controller has superior performance at various operation conditions when it was compared to the PI and fixed angle pitch control mechanisms.
- 14 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 324-329
A Fuzzy Controlled Pitch Angle in a Permanent Magnet Synchronous Generator Type Wind Energy Conversion System
Controlling technique of the pitch angle is an efficient mechanism to control the mechanical torque of the wind turbine system during a strong wind beyond the rated operating wind speed of the turbine. To control the pitch angle, we have to choose generator’s electrical power, rotor speed, wind speed, and the turbine power coefficient as control parameters. In this article, a pitch angle controller based on fuzzy logic is introduced using the PMSG power as a control variable and wind speed as a sensitivity parameter to improve the control performance of the controller. The fuzzy logic controller is designed and its effectiveness is compared to the PI controller and fixed pitch angle control mechanisms. The simulation result shows that the fuzzy logic pitch angle controller has superior performance at various operation conditions when it was compared to the PI and fixed angle pitch control mechanisms.
- Open Access
- 29 April 2022
- Published by Hindawi Limited in Journal of Electrical and Computer Engineering
- Vol. 2022, 1-22
Performance of Various Voltage Stability Indices in a Stochastic Multiobjective Optimal Power Flow Using Mayfly Algorithm
The performance of voltage stability indices in the multiobjective optimal power flow of modern power systems is presented in this work. Six indices: the Voltage Collapse Proximity Index (VCPI), Line Voltage Stability Index (LVSI), Line Stability Index (Lmn), Fast Voltage Stability Index (FVSI), Line Stability Factor (LQP), and Novel Line Stability Index (NLSI) were considered as case studies on a modified IEEE 30-bus consisting of thermal, wind, solar and hybrid wind-hydro generators. A multiobjective evaluation using the multiobjective mayfly algorithm (MOMA) was performed in two operational scenarios: normal and contingency conditions, using the MATLAB-MATPOWER toolbox. Fuzzy Decision-Making technique was used to determine the best compromise solutions for each Pareto front. To evaluate the computational efficiency of the case studies, a preference selection index was used. The results indicate that VCPI and NLSI yielded the best-optimized system performance in minimizing generation costs, transmission loss reduction, and simulation time for normal and contingency conditions. The best-case studies also promoted the most scheduled reactive power generation from renewable energy sources (RES). On average, the VCPI index contributed the highest penetration level from RES (13.40%), while the Lmn index had the lowest. Overall, VCPI and Lmn index provided the best and worst average performance in both operating scenarios, respectively. Also, the MOMA algorithm demonstrated superior performance against the multiobjective harris hawks algorithm (MHHO), multiobjective Jaya algorithm (MOJAYA), multiobjective particle swarm algorithm (MOPSO), and nondominated sorting genetic algorithm III (NSGA-III) algorithms. In all, the proposed approach yields the lowest system cost and loss compared to other methods.
- 29 April 2022
- Published by Hindawi Limited in Journal of Electrical and Computer Engineering
- Vol. 2022, 1-22
Open AccessPerformance of Various Voltage Stability Indices in a Stochastic Multiobjective Optimal Power Flow Using Mayfly Algorithm
The performance of voltage stability indices in the multiobjective optimal power flow of modern power systems is presented in this work. Six indices: the Voltage Collapse Proximity Index (VCPI), Line Voltage Stability Index (LVSI), Line Stability Index (Lmn), Fast Voltage Stability Index (FVSI), Line Stability Factor (LQP), and Novel Line Stability Index (NLSI) were considered as case studies on a modified IEEE 30-bus consisting of thermal, wind, solar and hybrid wind-hydro generators. A multiobjective evaluation using the multiobjective mayfly algorithm (MOMA) was performed in two operational scenarios: normal and contingency conditions, using the MATLAB-MATPOWER toolbox. Fuzzy Decision-Making technique was used to determine the best compromise solutions for each Pareto front. To evaluate the computational efficiency of the case studies, a preference selection index was used. The results indicate that VCPI and NLSI yielded the best-optimized system performance in minimizing generation costs, transmission loss reduction, and simulation time for normal and contingency conditions. The best-case studies also promoted the most scheduled reactive power generation from renewable energy sources (RES). On average, the VCPI index contributed the highest penetration level from RES (13.40%), while the Lmn index had the lowest. Overall, VCPI and Lmn index provided the best and worst average performance in both operating scenarios, respectively. Also, the MOMA algorithm demonstrated superior performance against the multiobjective harris hawks algorithm (MHHO), multiobjective Jaya algorithm (MOJAYA), multiobjective particle swarm algorithm (MOPSO), and nondominated sorting genetic algorithm III (NSGA-III) algorithms. In all, the proposed approach yields the lowest system cost and loss compared to other methods.