Dessalegn Bitew Aeggegn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dessalegn Bitew Aeggegn has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Sherif S. M. Ghoneim
Department of Electrical Engineering, College of Engineering, Taif University, Taif, Saudi Arabia
4 shared publications- Cyrus Wekesa
School of Engineering, University of Eldoret, Eldoret, Kenya.
3 shared publications Enas Ali
Centre for Research Impact & Outcome, Chitkara University Institute of Engineering and Technology, Chitkara University, Rajpura, India
3 shared publications- George Nyauma Nyakoe
Department of Electrical and Electronic Engineering, Jomo Kenyatta University of Agriculture and Technology, Nairobi, Kenya, India
3 shared publications Badreddine Babes
Research Center in Industrial Technologies CRTI, Algiers, Algeria
2 shared publications- Churchill Otieno Saoke
Institute of Energy and Environmental Technology, Jomo Kenyatta University of Agriculture and Technology 1 , Juja
2 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (11)
Techno-economic optimization of an off-grid solar-wind-battery energy storage system for sustainable rural electrification in Dibo, Ethiopia
Existing microgrid modeling often ignores the electrical mismatch in the modules and obstructions in the vicinity, creating unrealistic estimates of energy production. To fill this gap, this study combines weather data from Meteonorm 8.1 with PVsyst for accurate 3D spatial shading analysis and Hybrid Optimization Model for Electric Renewables Pro for life-cycle cost optimization of an off-grid solar-wind-battery system in Dibo, Ethiopia. The system was designed to supply a primary electrical load of 2714.32 kWh/day together with a deferrable load of 38.8 kWh/day. The annual solar yield penalty and total system loss for explicit 3D shading constraints are 3.63% and 15.63%, respectively. With baseline unshaded conditions, the system’s Net Present Cost (NPC) is $740 112, its Levelized Cost of Energy (LCOE) is $0.0332/kWh, and the mix of renewables provided by the system is 67.9% solar PV and 32.1% wind energy. With a realistic 3D spatial layout and near-shading losses, the system dynamically scales up its component size to reliably deliver the community demand of 1 004 133 kWh/yr. As a result, the overall generation mix is slightly modified to 65.4% solar PV and 34.6% wind, and the overall NPC of the system rises to $747 512, with the LCOE at $0.0335/kWh, while the unmet load is very small at 0.0734%. The structural economic robustness is verified by sensitivity analyses in the face of market changes. This mechanism is foundational in the pipeline of renewable energy projects in sub-Saharan Africa, where explicit terrain and module designs ensure component sizing, ensuring a solid route to rural electrification.
- 1 November 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (11)
Open AccessTechno-economic optimization of an off-grid solar-wind-battery energy storage system for sustainable rural electrification in Dibo, Ethiopia
Existing microgrid modeling often ignores the electrical mismatch in the modules and obstructions in the vicinity, creating unrealistic estimates of energy production. To fill this gap, this study combines weather data from Meteonorm 8.1 with PVsyst for accurate 3D spatial shading analysis and Hybrid Optimization Model for Electric Renewables Pro for life-cycle cost optimization of an off-grid solar-wind-battery system in Dibo, Ethiopia. The system was designed to supply a primary electrical load of 2714.32 kWh/day together with a deferrable load of 38.8 kWh/day. The annual solar yield penalty and total system loss for explicit 3D shading constraints are 3.63% and 15.63%, respectively. With baseline unshaded conditions, the system’s Net Present Cost (NPC) is $740 112, its Levelized Cost of Energy (LCOE) is $0.0332/kWh, and the mix of renewables provided by the system is 67.9% solar PV and 32.1% wind energy. With a realistic 3D spatial layout and near-shading losses, the system dynamically scales up its component size to reliably deliver the community demand of 1 004 133 kWh/yr. As a result, the overall generation mix is slightly modified to 65.4% solar PV and 34.6% wind, and the overall NPC of the system rises to $747 512, with the LCOE at $0.0335/kWh, while the unmet load is very small at 0.0734%. The structural economic robustness is verified by sensitivity analyses in the face of market changes. This mechanism is foundational in the pipeline of renewable energy projects in sub-Saharan Africa, where explicit terrain and module designs ensure component sizing, ensuring a solid route to rural electrification.
- Open Access
- 23 July 2026
- Published by Elsevier in Next Energy
- Vol. 13
AI-driven predictive maintenance for enhanced reliability of power transformers: Systematic review
- 23 July 2026
- Published by Elsevier in Next Energy
- Vol. 13
Open AccessAI-driven predictive maintenance for enhanced reliability of power transformers: Systematic review
- 25 January 2026
- Published by Science Publishing Group in American Journal of Electrical Power and Energy Systems
- Vol. 15 (1) , 1-13
Optimized Load Shedding for Voltage Resilience in Ethiopia's Power Grid
This study deals with the essential operational challenges of voltage instability in the Northwest Ethiopian transmission network (NETN), which is a rapidly growing energy demand. An intelligent voltage load-shedding framework, Particle Swarm Optimization, was used for the multi-objective function under contingency scenarios. The proposed method, tested on NETN, comprising 15 buses, 15 lines, two generators, and three external grids, was used to analyze the grid behavior under significant load escalation (50% and 75% increase). The results indicated severe voltage drops at critical buses, notably Metema and Gondar (Metema’s voltage declined from 0.978 p.u. to 0.8638 p.u. at 75% overload). The proposed algorithm combines voltage sensitivity indices with dynamic load-shedding logic to determine the exact place & magnitude of real power changes. PSO-based optimization simultaneously minimizes active power curtailment while maximizing voltage profile recovery. Upon activation, the strategy restored bus voltages to secure levels (Metema up to 0.9538 p.u.) with precise bus-specific shedding of real power. This method effectively and rapidly transitions the system from an emergency to a normal state with minimal load loss. In contrast to traditional approaches, this comprehensive method explores feasibility in near real-time and guarantees system-wide coordination, providing a cost-effective solution for enhancing reliability in developing power systems across various uncertainty and stress conditions. These findings provide an innovative and practical foundation for enhancing the voltage stability.
- 25 January 2026
- Published by Science Publishing Group in American Journal of Electrical Power and Energy Systems
- Vol. 15 (1) , 1-13
Optimized Load Shedding for Voltage Resilience in Ethiopia's Power Grid
This study deals with the essential operational challenges of voltage instability in the Northwest Ethiopian transmission network (NETN), which is a rapidly growing energy demand. An intelligent voltage load-shedding framework, Particle Swarm Optimization, was used for the multi-objective function under contingency scenarios. The proposed method, tested on NETN, comprising 15 buses, 15 lines, two generators, and three external grids, was used to analyze the grid behavior under significant load escalation (50% and 75% increase). The results indicated severe voltage drops at critical buses, notably Metema and Gondar (Metema’s voltage declined from 0.978 p.u. to 0.8638 p.u. at 75% overload). The proposed algorithm combines voltage sensitivity indices with dynamic load-shedding logic to determine the exact place & magnitude of real power changes. PSO-based optimization simultaneously minimizes active power curtailment while maximizing voltage profile recovery. Upon activation, the strategy restored bus voltages to secure levels (Metema up to 0.9538 p.u.) with precise bus-specific shedding of real power. This method effectively and rapidly transitions the system from an emergency to a normal state with minimal load loss. In contrast to traditional approaches, this comprehensive method explores feasibility in near real-time and guarantees system-wide coordination, providing a cost-effective solution for enhancing reliability in developing power systems across various uncertainty and stress conditions. These findings provide an innovative and practical foundation for enhancing the voltage stability.
- Open Access
- 7 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
An optimized shunt active power filter using the golden Jackal optimizer for power quality improvement
Integration of nonlinear loads in modern power systems has led to many issues arising mainly due to the generation of harmonic currents and the presence of reactive power, both having adverse effects on power quality and grid stability. Harmonic currents cause increased losses, overheating of equipment, and voltage distortions, while reactive power imbalances result in inefficiencies in power delivery and compromised system performance. To overcome these problems, a Shunt Active Power FIlter design and an optimal control strategy for harmonic mitigation and reactive power compensation are proposed in this paper. The design incorporates an optimized anti-windup PI controller for DC-link voltage regulation and an optimized output filter to enhance the quality of the injected current. This design is formulated as an optimization problem and solved using the Golden Jackal Optimizer. MATLAB/Simulink simulations validate the proposed method under different operating conditions, covering dynamic change of loads and unbalanced grid conditions. The result shows a remarkable reduction in Total Harmonic Distortion (THD) of grid current, and reactive power compensation meanwhile maintaining the stability of the grid.
- 7 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-13
Open AccessAn optimized shunt active power filter using the golden Jackal optimizer for power quality improvement
Integration of nonlinear loads in modern power systems has led to many issues arising mainly due to the generation of harmonic currents and the presence of reactive power, both having adverse effects on power quality and grid stability. Harmonic currents cause increased losses, overheating of equipment, and voltage distortions, while reactive power imbalances result in inefficiencies in power delivery and compromised system performance. To overcome these problems, a Shunt Active Power FIlter design and an optimal control strategy for harmonic mitigation and reactive power compensation are proposed in this paper. The design incorporates an optimized anti-windup PI controller for DC-link voltage regulation and an optimized output filter to enhance the quality of the injected current. This design is formulated as an optimization problem and solved using the Golden Jackal Optimizer. MATLAB/Simulink simulations validate the proposed method under different operating conditions, covering dynamic change of loads and unbalanced grid conditions. The result shows a remarkable reduction in Total Harmonic Distortion (THD) of grid current, and reactive power compensation meanwhile maintaining the stability of the grid.
- Open Access
- 26 April 2025
- Published by Elsevier in Results in Engineering
- Vol. 26
Extension of Maxwell's equations for non-stationary magnetic fluids using gauss's divergence theorem
- 26 April 2025
- Published by Elsevier in Results in Engineering
- Vol. 26
Open AccessExtension of Maxwell's equations for non-stationary magnetic fluids using gauss's divergence theorem
- Open Access
- 4 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-33
HIL co-simulation of an optimal hybrid fractional-order type-2 fuzzy PID regulator based on dSPACE for quadruple tank system
Accurate regulation of the liquid level in a quadruple tank system (QTS) is not easy and imposes higher requirements on control strategies, so the design of controllers in these systems is challenging due to the difficulty of dynamic analysis of its nonlinear characteristics and parametric uncertainties. To overcome these problems in liquid level regulation and increase the robustness to the pump coefficients, this article proposes and investigates the use of an optimal hybrid fractional-order type-2 fuzzy-PID (OH-FO-T2F-PID) regulator using a combination of two bio-inspired evolutionary optimizers, namely augmented grey wolf optimizer and cuckoo search optimizer, which gives rise to the new hybrid A-GWOCS algorithm. This control mechanism was chosen to facilitate the convergence of the water liquids in the two tanks as quickly as possible to the corresponding required values. In addition, a collaborative optimization technique with several objectives is used to adjust the regulator parameters. The capability and efficiency of the suggested regulator is first investigated through computer simulation results and then confirmed by real-time control experimental results on the QTS based on dSPACE 1104 computation engine. The findings showed that the suggested OH-FO-T2F-PID regulator significantly outperformed both the optimized ADRC and the OH-FO-T1F-PID regulators. Specifically, it reduced the rising time by 17.02% and 95.21%, respectively, and the settling time by 25.13% and 74.28%. Additionally, the designed OH-FO-T2F-PID regulator successfully eliminated the steady-state error and overshoot, enabling precise regulation of the QTS, and maintenance the liquid level at the desired set point under a wide range of working situations. The robustness of the recommended regulator is also studied by considering − 50% disturbance in the QTS parameters, and the findings showed that the OH-FO-T2F-PID regulator is less susceptible to variations in parameters.
- 4 March 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-33
Open AccessHIL co-simulation of an optimal hybrid fractional-order type-2 fuzzy PID regulator based on dSPACE for quadruple tank system
Accurate regulation of the liquid level in a quadruple tank system (QTS) is not easy and imposes higher requirements on control strategies, so the design of controllers in these systems is challenging due to the difficulty of dynamic analysis of its nonlinear characteristics and parametric uncertainties. To overcome these problems in liquid level regulation and increase the robustness to the pump coefficients, this article proposes and investigates the use of an optimal hybrid fractional-order type-2 fuzzy-PID (OH-FO-T2F-PID) regulator using a combination of two bio-inspired evolutionary optimizers, namely augmented grey wolf optimizer and cuckoo search optimizer, which gives rise to the new hybrid A-GWOCS algorithm. This control mechanism was chosen to facilitate the convergence of the water liquids in the two tanks as quickly as possible to the corresponding required values. In addition, a collaborative optimization technique with several objectives is used to adjust the regulator parameters. The capability and efficiency of the suggested regulator is first investigated through computer simulation results and then confirmed by real-time control experimental results on the QTS based on dSPACE 1104 computation engine. The findings showed that the suggested OH-FO-T2F-PID regulator significantly outperformed both the optimized ADRC and the OH-FO-T1F-PID regulators. Specifically, it reduced the rising time by 17.02% and 95.21%, respectively, and the settling time by 25.13% and 74.28%. Additionally, the designed OH-FO-T2F-PID regulator successfully eliminated the steady-state error and overshoot, enabling precise regulation of the QTS, and maintenance the liquid level at the desired set point under a wide range of working situations. The robustness of the recommended regulator is also studied by considering − 50% disturbance in the QTS parameters, and the findings showed that the OH-FO-T2F-PID regulator is less susceptible to variations in parameters.
- Open Access
- 14 January 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-18
Experimental evaluation of DC-DC buck converter based on adaptive fuzzy fast terminal synergetic controller
This study suggests an enhanced version of the adaptive fuzzy fast terminal synergetic controller (AF-FTSC) for controlling the uncertain DC/DC buck converter based on the synergetic theory of control (STC) and newly developed terminal attractor technique (TAT). The benefits of the proposed SC algorithm involve the features of finite-time convergence, unaffected by parameter variations, and chattering-free phenomenon. A type-1 fuzzy logic system (T1-FLS) make the considered controller more robust and is utilized to estimate the undefined converter nonlinear dynamics without resorting to the usual linearization and simplifications of the converter model. Taking a switching DC-DC buck converter as a demonstration, the suggested AF-FTSC is thoroughly analyzed and executed on a dSPACE ds1103 controller board. The outcomes of the experiment confirm the competence and applicability of the suggested regulator.
- 14 January 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-18
Open AccessExperimental evaluation of DC-DC buck converter based on adaptive fuzzy fast terminal synergetic controller
This study suggests an enhanced version of the adaptive fuzzy fast terminal synergetic controller (AF-FTSC) for controlling the uncertain DC/DC buck converter based on the synergetic theory of control (STC) and newly developed terminal attractor technique (TAT). The benefits of the proposed SC algorithm involve the features of finite-time convergence, unaffected by parameter variations, and chattering-free phenomenon. A type-1 fuzzy logic system (T1-FLS) make the considered controller more robust and is utilized to estimate the undefined converter nonlinear dynamics without resorting to the usual linearization and simplifications of the converter model. Taking a switching DC-DC buck converter as a demonstration, the suggested AF-FTSC is thoroughly analyzed and executed on a dSPACE ds1103 controller board. The outcomes of the experiment confirm the competence and applicability of the suggested regulator.
- Open Access
- 12 December 2024
- Published by Elsevier in Energy Reports
- Vol. 13, 286-302
An Energy Management System for Multi-Microgrid system considering uncertainties using multi-objective multi-verse optimization
- 12 December 2024
- Published by Elsevier in Energy Reports
- Vol. 13, 286-302
Open AccessAn Energy Management System for Multi-Microgrid system considering uncertainties using multi-objective multi-verse optimization
- Open Access
- 17 June 2024
- Published by Elsevier in Results in Engineering
- Vol. 23
Optimal sizing of grid connected multi-microgrid system using grey wolf optimization
- 17 June 2024
- Published by Elsevier in Results in Engineering
- Vol. 23
Open AccessOptimal sizing of grid connected multi-microgrid system using grey wolf optimization
- Open Access
- 13 April 2024
- Published by Taylor & Francis in Cogent Engineering
- Vol. 11 (1)
A state of the art review on energy management techniques and optimal sizing of DERs in grid-connected multi-microgrids
- 13 April 2024
- Published by Taylor & Francis in Cogent Engineering
- Vol. 11 (1)
Open AccessA state of the art review on energy management techniques and optimal sizing of DERs in grid-connected multi-microgrids