CWCyrus Wekesa

Cyrus Wekesa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Cyrus Wekesa has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Metaheuristic-based optimal sizing of standalone PV-wind-BESS-EV hybrid renewable energy system

    by Fsaha Mebrahtu Gebru, Cyrus Wekesa, Peter Moses Musau, Suud Ademnur Hasen


  • Open Access

    A hybrid ANN-PSO approach for self-tuning parameters of polycrystalline photovoltaic arrays

    by Zouhir Boumous, Samira Boumous, Moussa Sedraoui, Mohcene Bechouat, Cyrus Wabuge Wekesa, Ramazan Ayaz

    This paper introduces a novel, self-tuning equivalent circuit model for polycrystalline photovoltaic (PV) modules to overcome the accuracy limitations of conventional fixed-parameter models under dynamic climatic conditions. The proposed model features dynamically adjustable parameters-the diode quality factor, series resistance, and shunt resistance-that evolve with changes in solar irradiance, temperature, and wind speed. The design of this adaptive model is achieved through a dedicated two-stage hybrid methodology. First, an artificial neural network (ANN) trained via the Back-Propagation Neural Network (BPNN) technique on 300 experimental samples establishes an initial mapping from climatic inputs to the optimal electrical parameters. The primary force of the proposed hybridization is that the optimal biases and weights from this ANN-BPNN model are then used to meticulously initialize the Particle Swarm Optimization (PSO) algorithm. In the second stage, this PSO algorithm, leveraging its superior initial population, performs a refined minimization of the Mean Squared Error (MSE) between the predicted and measured PV currents to yield the final, high-precision model. For validation, this model is compared against a conventional fixed-parameter model optimized with the same PSO parameters. The results demonstrate a dramatic accuracy improvement: the proposed dynamic model achieves an MSE of 0.0387, a 90.82% reduction compared to the conventional model's MSE of 0.4226. The key novelty lies in this effective ANN-PSO hybridization, which ensures robust and accurate dynamic modeling, providing a superior foundation for advanced PV system applications like maximum power point tracking (MPPT).


  • Open Access

    Power System Voltage Stability Assessment and Control Strategies: State‐of‐the‐Art Review

    by Yalew Gebru Werkie, George Nyauma Nyakoe, Cyrus Wabuge Wekesa

    Voltage stability is crucial for power systems, ensuring that electrical grids maintain voltages within acceptable limits with increasing demand, renewable energy integration, and changing network topology. This paper reviews the voltage stability phenomena, voltage stability indices (VSIs) (line and bus), and offline/online voltage stability assessment considering load variations, uncertain renewable energy, and network structures. Multiple VSIs and algorithms quantify voltage stability, providing information on the system’s resilience to disruptions. A systematic review encompassing the essential aspects of mathematical formulation, expressions, constraints, and applicability of VSIs is presented. Also discussed is the voltage stability control strategy employing flexible AC transmission system (FACTS) devices, considering the incorporation of the power generated from renewable resources. A comparison of voltage stability analysis methodologies is performed. The study offers power system researchers and practitioners a comprehensive summary of voltage stability assessment methods and control strategies for integrating various FACTS devices with renewable energy sources. Finally, the challenges and limitations of voltage stability assessment and control are discussed, as are further research directions.


  • Open Access

    Optimal sizing and placement of STATCOM, TCSC and UPFC using a novel hybrid genetic algorithm-improved particle swarm optimization

    by Urbanus Mwanzia Ngei, Abraham Mutunga Nyete, Peter Musau Moses, Cyrus Wekesa


  • Open Access

    Optimal sizing of grid connected multi-microgrid system using grey wolf optimization

    by Dessalegn Bitew Aeggegn, George Nyauma Nyakoe, Cyrus Wekesa


  • Open Access

    Multi-criteria optimal sizing and analysis of PV/wind/fuel cell/battery/diesel generator for rural electrification: A case study in Chad

    by Mahamat Adoum Abdoulaye, Sebastian Waita, Cyrus Wabuge Wekesa, Julius Mwakondo Mwabora

    Access to sustainable, clean, affordable, and reliable electricity is crucial for social and economic development, yet Sub-Saharan Africa (SSA) struggles significantly in this context. In CHAD, only 11.3% of the population is able to access electricity, making it one of the least electrified countries in SSA with the lowest clean energy access. In rural areas, electricity access falls to just 1.3%. This research applies and executes a Multi-Objective Particle Swarm Optimization (MOPSO) algorithm using MATLAB R2023b to assess the techno-economic, environmental, and social impacts of a hybrid system based on optimal PV/Wind/Battery/Fuel Cell (FC)/Diesel generator (DG) sizing for rural electrification in CHAD. The proposed system's self-sufficiency index (SSSI) and the Annualized System Cost (ASC) were chosen as objective functions to guarantee the economic feasibility of the system, higher self-sufficiency, and lower dependence on external energy sources (DG). The simulation results show that the optimal size of the proposed system supplies the load demand by 100% of the renewable energy sources (RES) fraction, and the optimal capacities of the main components to supply the load demand are: Solar Power (493 KW), Wind Turbine (166 KW), Battery Energy Charge/Discharge (229180 kWh /221300 kWh), Hydrogen tank storage energy (83 874 kWh), Electrolyzer size (202 KW), Fuel cell size (144 KW). The evelized cost of electricity (LCOE) of 0.2982 $/kWh, which is 51.12% lower than the national unit production costs of electricity in rural areas of CHAD (0.61 $/kWh). This LCOE is also the lowest compared to previous works done using HOMER Pro for the country of CHAD. The results also give a levelized cost of hydrogen (LCOH) of 3.8563 US $/kg, lower than for all studies found in the literature for the country of Chad. The proposed system's yearly avoided greenhouse gas (GHG) emission is 374 640 kg. The proposed system will create five (5) new jobs (JCO) and improve the Human Development Index (HDI) of the study area by 17.66% (the obtained HDI is 0.4683, and the CHAD HDI is 0.398) with an SSSI of 51.14%. This study provides a better practical energy design tool in decision-making for designers, companies, investors, policymakers, and the Chadian government when implementing this type of system in particular rural locations.


  • Open Access

    ANFIS‐Controlled Boost and Bidirectional Buck‐Boost DC‐DC Converters for Solar PV, Fuel Cell, and BESS‐Based Microgrid Application

    by Dessalegn Bitew Aeggegn, George Nyauma Nyakoe, Cyrus Wekesa

    DC‐DC converters are essential for integrating distributed energy resources into microgrid (MG) systems. These converters are designed to incorporate intermittent renewable energy sources such as solar photovoltaic (PV) panels, fuel cells (FCs), and battery energy storage systems (BESSs) into the grid. However, conventional DC‐DC converters have limitations including lower efficiency, voltage ripple, insufficient voltage regulation, and compatibility issues. This article presents boost and bidirectional buck‐boost converters for direct current microgrid (DCMG) applications, employing an adaptive neuro‐fuzzy inference system (ANFIS) for control. These proposed converter configurations adeptly manage wide input voltage fluctuations from intermittent sources, consistently supplying power to the DC bus at 500 V and 120 V for boost and buck operations, respectively, with an efficiency of 98.8%. The output voltage result shows that the ANFIS‐based boost converter has 10% overshoot as compared to 41% and 50% overshoot in proportional integral (PI) and fuzzy logic controller (FLC), respectively. In both buck and boost modes, the converters’ voltage gain is influenced by duty ratio adjustments only, not sensitive to dynamic input voltage and flexible manipulation of the output voltage for BESS charging. Moreover, the designed converters accommodate load variations within the MG. To assess the converters’ ability to regulate output voltage effectively, PI, FLC, and ANFIS controllers are implemented and compared. And the ANFIS controller demonstrates superior performance, offering faster response times and enhanced stability. Evaluations are conducted through simulations in the MATLAB/Simulink environment.


  • Open Access

    Wind Energy Resource Prediction and Optimal Storage Sizing to Guarantee Dispatchability: A Case Study in the Kenyan Power Grid

    by Hampfrey Odero, Cyrus Wekesa, George Irungu

    Kenya is experiencing a fast increase in grid-connected intermittent renewable energy sources (RESs) to meet its increased power demand, and at the same time be able to fulfill its Paris Agreement obligations of abating greenhouse gas emissions. For instance, Kenya has 102 MW of grid-tied solar power and 410 MW of grid-tied wind power. However, these sources are very intermittent with low predictability. Thus, after their installation and integration into the grid, they impose a new challenge for the secure, reliable, and economic operation of the system. To mitigate these and to ensure proper planning of the system operations, accurate and faster prediction of the generation output of the wind energy resources and optimal design and sizing of storage for the large-scale wind energy integration into the grid are of paramount importance. Artificial intelligence (AI) and metaheuristic techniques have proven to be efficient and robust in offering solutions to complex nonlinear prediction and optimization problems. Therefore, this study aims to utilize backpropagation neural network (BPNN) algorithm to conduct hourly prediction of the generation output of Lake Turkana Wind Power Plant (LTWPP), a 310 MW plant connected to the Kenyan power grid, and optimally size its battery energy storage system (BESS) using genetic algorithm (GA) to guarantee its dispatchability. The historical weather data, namely wind speed, ambient temperature, relative humidity, wind direction, and generation output from LTWPP, are employed in the training, testing, and validation of the neural network. LTWPP and BESS are modelled in MATLAB R2016a software. Thereafter, the developed BPNN and GA algorithms are applied to the modelled systems to predict the wind output and optimize the storage system, respectively. BESS optimization with neural prediction reduces the BESS capacity and investment costs by 59.82%, while the overall dispatchability of LTWPP is increased from 73.36% to 90.14%, hence enabling the farm to meet its allowable loss of power supply probability (LPSP) index of 0.1 while guaranteeing its dispatchability.