Jian Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jian Song has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Bennett Kalafut
MOBILion Systems, Inc.
2 shared publications- Changbin Yu
College of Medical Information and Artificial Intelligence, Jinan Central Hospital Affiliated to Shandong First Medical University, Shandong First Medical University and Shandong Academy of Medical Sciences
2 shared publications - Liulin Deng
MOBILion Systems, Inc., 4 Hillman Drive, Suite 130, Chadds Ford, Pennsylvania 19317, United States
2 shared publications - Xiaohui Wu
Cancer Institute, Suzhou Medical College, Soochow University, Suzhou, China
2 shared publications - Bo Wang
Department of Pathology The First Affiliated Hospital, Zhejiang University School of Medicine Hangzhou China
1 shared publication - Changbin Yu
School of Engineering Westlake University Hangzhou China
1 shared publication
Latest Publications
- 9 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 30080-30090
xTracer: Integrating Chromatogram and Mobilogram Correlations for Untargeted Peptide Identification in SLIM-Based PAMAF Data
Parallel accumulation with mobility-aligned fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry-based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF, where precursor−fragment relationships are encoded along the mobility dimension, is not ideally suited to many existing peptide identification tools. Here, we present xTracer, an untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming both single-domain correlation strategies and diaTracer, which was developed for diaPASEF data. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility-based proteomics.
- 9 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (44) , 30080-30090
xTracer: Integrating Chromatogram and Mobilogram Correlations for Untargeted Peptide Identification in SLIM-Based PAMAF Data
Parallel accumulation with mobility-aligned fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry-based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF, where precursor−fragment relationships are encoded along the mobility dimension, is not ideally suited to many existing peptide identification tools. Here, we present xTracer, an untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming both single-domain correlation strategies and diaTracer, which was developed for diaPASEF data. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility-based proteomics.
- Open Access
xTracer: Integrating chromatogram and mobiligram correlations for untargeted peptide identification in SLIM-based PAMAF data
Parallel Accumulation with Mobility-Aligned Fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry–based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF where precursor–fragment relationships are encoded along the mobility dimension renders it incompatible with existing peptide identification tools. Here, we present xTracer, the first untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming single-domain correlation strategies. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility (HRIM)–based proteomics.
Open AccessxTracer: Integrating chromatogram and mobiligram correlations for untargeted peptide identification in SLIM-based PAMAF data
Parallel Accumulation with Mobility-Aligned Fragmentation (PAMAF) achieves near-complete ion utilization and high spectral specificity by fragmenting all mobility-separated precursors without quadrupole isolation. Leveraging the ultrahigh mobility resolution of SLIM, this quadrupole-free strategy maximizes ion utilization efficiency and offers a promising approach in mass spectrometry–based proteomics, particularly for low-abundance peptides or low-input samples. However, the unique data structure of PAMAF where precursor–fragment relationships are encoded along the mobility dimension renders it incompatible with existing peptide identification tools. Here, we present xTracer, the first untargeted peptide identification algorithm developed specifically for PAMAF data. xTracer integrates correlations across both chromatographic and mobility dimensions to associate precursor and fragment ions, reconstruct pseudo-spectra, and enable database searching using well-established DDA search engines. Applied to datasets with varying sample loads and acquisition throughputs, xTracer consistently achieved robust and reproducible peptide identifications, outperforming single-domain correlation strategies. Overall, xTracer provides a versatile and high-efficiency computational framework for reconstructing pseudo-spectra from quadrupole-free, mobility-aligned fragmentation data, enhancing the analytical power of high-resolution ion mobility (HRIM)–based proteomics.
- Open Access
- 26 December 2024
- Published by Oxford University Press (OUP) in Bioinformatics Advances
- Vol. 5 (1)
Disc-Hub: a python package for benchmarking machine learning strategies in DIA-MS identification
Motivation: Accurate analysis of data-independent acquisition (DIA) mass spectrometry data relies on machine learning to distinguish target peptides from decoy peptides. Different DIA identification engines adopt distinct binary classifiers and training workflows to accomplish this learning task. However, systematic comparisons of how different machine learning strategies affect identification performance are lacking. This absence of evaluation hinders optimal learning strategy selection, increases the risk of model underfitting or overfitting, and ultimately undermines the effectiveness and reliability of false discovery rate (FDR) control. Results: In this study, we benchmarked three training strategies and four classifiers on representative DIA datasets. Among them, K-fold training combined with a multilayer perceptron achieved the best balance between identification depth and FDR control. We have released the datasets and code through the Python package Disc-Hub, enabling rapid selection of optimal machine learning configurations for developing DIA identification algorithms. Availability and implementation: Disc-Hub is released as an open source software and can be installed from PyPi as a python module. The source code is available on GitHub at https://github.com/yuyiwen-yiyuwen/Disc_Hub.
- 26 December 2024
- Published by Oxford University Press (OUP) in Bioinformatics Advances
- Vol. 5 (1)
Open AccessDisc-Hub: a python package for benchmarking machine learning strategies in DIA-MS identification
Motivation: Accurate analysis of data-independent acquisition (DIA) mass spectrometry data relies on machine learning to distinguish target peptides from decoy peptides. Different DIA identification engines adopt distinct binary classifiers and training workflows to accomplish this learning task. However, systematic comparisons of how different machine learning strategies affect identification performance are lacking. This absence of evaluation hinders optimal learning strategy selection, increases the risk of model underfitting or overfitting, and ultimately undermines the effectiveness and reliability of false discovery rate (FDR) control. Results: In this study, we benchmarked three training strategies and four classifiers on representative DIA datasets. Among them, K-fold training combined with a multilayer perceptron achieved the best balance between identification depth and FDR control. We have released the datasets and code through the Python package Disc-Hub, enabling rapid selection of optimal machine learning configurations for developing DIA identification algorithms. Availability and implementation: Disc-Hub is released as an open source software and can be installed from PyPi as a python module. The source code is available on GitHub at https://github.com/yuyiwen-yiyuwen/Disc_Hub.
- Open Access
Beta-DIA: Integrating learning-based and function-based feature scores to optimize the proteome profiling of single-shot diaPASEF mass spectrometry data
We present a freely available diaPASEF data analysis software, Beta-DIA, that utilizes deep learning methods to score coelution consistency in retention time-ion mobility dimensions and spectrum similarity. Beta-DIA integrates these learning-based scores with traditional function-based scores, enhancing the qualitative analysis performance. In some low detection datasets, Beta-DIA identifies twice as many protein groups as DIA-NN. The success of Beta-DIA has paved another way for the application of deep learning in fundamental proteome profiling.
Open AccessBeta-DIA: Integrating learning-based and function-based feature scores to optimize the proteome profiling of single-shot diaPASEF mass spectrometry data
We present a freely available diaPASEF data analysis software, Beta-DIA, that utilizes deep learning methods to score coelution consistency in retention time-ion mobility dimensions and spectrum similarity. Beta-DIA integrates these learning-based scores with traditional function-based scores, enhancing the qualitative analysis performance. In some low detection datasets, Beta-DIA identifies twice as many protein groups as DIA-NN. The success of Beta-DIA has paved another way for the application of deep learning in fundamental proteome profiling.
- Open Access
- 1 July 2024
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 40 (7)
Calib-RT: an open source python package for peptide retention time calibration in DIA mass spectrometry data
Motivation: The data independent acquisition (DIA) mass spectrometry (MS) method is increasingly popular in the field of proteomics. But the loss of the correspondence between peptide ions and their spectra in DIA makes the identification challenging. One effective approach to reduce false positive identification is to calculate the deviation between the peptide’s estimated retention time (RT) and measured RT. During this process, scaling the spectral library RT into the estimated RT, known as the RT calibration, is a prerequisite for calculating the deviation. Currently, within the DIA algorithm ecosystem, there is a lack of engine-independent and readily usable RT calibration toolkits. Results: In this work, we introduce Calib-RT, a RT calibration method tailored to the characteristics of RT data. This method can achieve the nonlinear calibration across various data scales and tolerate a certain level of noise interference. Calib-RT is expected to enrich the open source DIA algorithm toolchain and assist in the development of DIA identification algorithms. Availability and implementation: Calib-RT is released as an open source software under the MIT license and can be installed from PyPi as a python module. The source code is available on GitHub at https://github.com/chenghui03/Calib_RT.
- 1 July 2024
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 40 (7)
Open AccessCalib-RT: an open source python package for peptide retention time calibration in DIA mass spectrometry data
Motivation: The data independent acquisition (DIA) mass spectrometry (MS) method is increasingly popular in the field of proteomics. But the loss of the correspondence between peptide ions and their spectra in DIA makes the identification challenging. One effective approach to reduce false positive identification is to calculate the deviation between the peptide’s estimated retention time (RT) and measured RT. During this process, scaling the spectral library RT into the estimated RT, known as the RT calibration, is a prerequisite for calculating the deviation. Currently, within the DIA algorithm ecosystem, there is a lack of engine-independent and readily usable RT calibration toolkits. Results: In this work, we introduce Calib-RT, a RT calibration method tailored to the characteristics of RT data. This method can achieve the nonlinear calibration across various data scales and tolerate a certain level of noise interference. Calib-RT is expected to enrich the open source DIA algorithm toolchain and assist in the development of DIA identification algorithms. Availability and implementation: Calib-RT is released as an open source software under the MIT license and can be installed from PyPi as a python module. The source code is available on GitHub at https://github.com/chenghui03/Calib_RT.
- 6 January 2022
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 38 (6) , 1525-1531
Alpha-Tri: a deep neural network for scoring the similarity between predicted and measured spectra improves peptide identification of DIA data
Motivation: Peptide identification of data-independent acquisition (DIA) mass spectrometry applying the peptide-centric approach heavily relies on the spectral library matching, such as the fragment intensity similarity. If the intensity similarity is calculated through all possible fragment ions of a targeted peptide instead of just a few fragment ions provided by the spectral library, the matching will be more comprehensive and reliable, and thus the identification will be more confident. In addition, the emergence of high precision spectrum predictors, like Prosit, also makes it possible to capitalize on the predicted spectrum, which contains all possible fragment ion intensities, to calculate the intensity similarity for DIA data. Results: In this work, we propose Alpha-Tri, a neural-network-based model to calculate intensity similarity as a post-processing score using the predicted spectrum, measured spectrum and correlation spectrum (triple-spectrum). The predicted spectrum is generated by Prosit, the measured spectrum is retrieved from the apex of the chromatograms of all possible fragment ions and the correlation spectrum is used to indicate the present probabilities of these fragment ions as the link between the precursor and its fragment ions is lost in DIA. By adopting a data-driven method, Alpha-Tri is able to learn the intensity similarity from the triple-spectrum. This learned value is appended to initial scores from DIA-NN, allowing the ensuing statistical validation tool to report more peptides at the same false discovery rate (FDR). In our evaluation of the HeLa dataset with gradient lengths ranging from 0.5 to 2 h, Alpha-Tri delivered 3.0–7.2% gains in peptide detections at 1% FDR. On LFQbench dataset, a mixed-species dataset with known ratios, Alpha-Tri identified more peptides and proteins fell within the valid ratio ranges by up to 8.6% and 7.6%, respectively, compared with DIA-NN solely. Availability and implementation: The original datasets for benchmarks are downloaded from the ProteomeXchange with the identifiers PXD005573, PXD000954 and PXD002952. Source code is available at https://github.com/YuAirLab/Alpha-Tri.
- 6 January 2022
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 38 (6) , 1525-1531
Alpha-Tri: a deep neural network for scoring the similarity between predicted and measured spectra improves peptide identification of DIA data
Motivation: Peptide identification of data-independent acquisition (DIA) mass spectrometry applying the peptide-centric approach heavily relies on the spectral library matching, such as the fragment intensity similarity. If the intensity similarity is calculated through all possible fragment ions of a targeted peptide instead of just a few fragment ions provided by the spectral library, the matching will be more comprehensive and reliable, and thus the identification will be more confident. In addition, the emergence of high precision spectrum predictors, like Prosit, also makes it possible to capitalize on the predicted spectrum, which contains all possible fragment ion intensities, to calculate the intensity similarity for DIA data. Results: In this work, we propose Alpha-Tri, a neural-network-based model to calculate intensity similarity as a post-processing score using the predicted spectrum, measured spectrum and correlation spectrum (triple-spectrum). The predicted spectrum is generated by Prosit, the measured spectrum is retrieved from the apex of the chromatograms of all possible fragment ions and the correlation spectrum is used to indicate the present probabilities of these fragment ions as the link between the precursor and its fragment ions is lost in DIA. By adopting a data-driven method, Alpha-Tri is able to learn the intensity similarity from the triple-spectrum. This learned value is appended to initial scores from DIA-NN, allowing the ensuing statistical validation tool to report more peptides at the same false discovery rate (FDR). In our evaluation of the HeLa dataset with gradient lengths ranging from 0.5 to 2 h, Alpha-Tri delivered 3.0–7.2% gains in peptide detections at 1% FDR. On LFQbench dataset, a mixed-species dataset with known ratios, Alpha-Tri identified more peptides and proteins fell within the valid ratio ranges by up to 8.6% and 7.6%, respectively, compared with DIA-NN solely. Availability and implementation: The original datasets for benchmarks are downloaded from the ProteomeXchange with the identifiers PXD005573, PXD000954 and PXD002952. Source code is available at https://github.com/YuAirLab/Alpha-Tri.
- 16 August 2021
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 38 (1) , 38-43
Alpha-XIC: a deep neural network for scoring the coelution of peak groups improves peptide identification by data-independent acquisition mass spectrometry
Motivation: The peptide-centric identification methodologies of data-independent acquisition (DIA) data mainly rely on scores for the mass spectrometric signals of targeted peptides. Among these scores, the coelution scores of peak groups constructed by the chromatograms of peptide fragment ions have a significant influence on the identification. Most of the existing coelution scores are achieved by artificially designing some functions in terms of the shape similarity, retention time shift of peak groups. However, these scores cannot characterize the coelution robustly when the peak group is in the circumstance of interference. Results: On the basis that the neural network is more powerful to learn the implicit features of data robustly from a large number of samples, and thus minimizing the influence of data noise, in this work, we propose Alpha-XIC, a neural network-based model to score the coelution. By learning the characteristics of the coelution of peak groups derived from the being analyzed DIA data, Alpha-XIC is capable of yielding robust coelution scores even for peak groups with interference. With this score appending to initial scores generated by the accompanying identification engine DIA-NN, the ensuing statistical validation can report the identification result and recover the misidentified peptides. In our evaluation of the HeLa dataset with gradient lengths ranging from 0.5 to 2 h, Alpha-XIC delivered 9.4–16.2% improvements in the number of identified precursors at 1% false discovery rate. Furthermore, Alpha-XIC was tested on LFQbench, a mixed-species dataset with known ratios, and increased the number of peptides and proteins fell within valid ratios by up to 16.4% and 17.8%, respectively, compared to the initial identification by DIA-NN. Availability and implementation: Source code is available at https://github.com/YuAirLab/Alpha-XIC.
- 16 August 2021
- Published by Oxford University Press (OUP) in Bioinformatics
- Vol. 38 (1) , 38-43
Alpha-XIC: a deep neural network for scoring the coelution of peak groups improves peptide identification by data-independent acquisition mass spectrometry
Motivation: The peptide-centric identification methodologies of data-independent acquisition (DIA) data mainly rely on scores for the mass spectrometric signals of targeted peptides. Among these scores, the coelution scores of peak groups constructed by the chromatograms of peptide fragment ions have a significant influence on the identification. Most of the existing coelution scores are achieved by artificially designing some functions in terms of the shape similarity, retention time shift of peak groups. However, these scores cannot characterize the coelution robustly when the peak group is in the circumstance of interference. Results: On the basis that the neural network is more powerful to learn the implicit features of data robustly from a large number of samples, and thus minimizing the influence of data noise, in this work, we propose Alpha-XIC, a neural network-based model to score the coelution. By learning the characteristics of the coelution of peak groups derived from the being analyzed DIA data, Alpha-XIC is capable of yielding robust coelution scores even for peak groups with interference. With this score appending to initial scores generated by the accompanying identification engine DIA-NN, the ensuing statistical validation can report the identification result and recover the misidentified peptides. In our evaluation of the HeLa dataset with gradient lengths ranging from 0.5 to 2 h, Alpha-XIC delivered 9.4–16.2% improvements in the number of identified precursors at 1% false discovery rate. Furthermore, Alpha-XIC was tested on LFQbench, a mixed-species dataset with known ratios, and increased the number of peptides and proteins fell within valid ratios by up to 16.4% and 17.8%, respectively, compared to the initial identification by DIA-NN. Availability and implementation: Source code is available at https://github.com/YuAirLab/Alpha-XIC.
- Open Access
Accelerated Protein Biomarker Discovery from FFPE tissue samples using Single-shot, Short Gradient Microflow SWATH MS
We report and evaluated a microflow, single-shot, short gradient SWATH MS method intended to accelerate the discovery and verification of protein biomarkers in clinical specimens. The method uses 15-min gradient microflow-LC peptide separation, an optimized SWATH MS window configuration and OpenSWATH software for data analysis. We applied the method to a cohort 204 of FFPE prostate tissue samples from 58 prostate cancer patients and 10 prostatic hyperplasia patients. Altogether we identified 27,976 proteotypic peptides and 4,043 SwissProt proteins from these 204 samples. Compared to a reference SWATH method with 2-hour gradient the accelerated method consumed only 27% instrument time, quantified 80% proteins and showed reduced batch effects. 3,800 proteins were quantified by both methods in two different instruments with relatively high consistency (r = 0.77). 75 proteins detected by the accelerated method with differential abundance between clinical groups were selected for further validation. A shortlist of 134 selected peptide precursors from the 75 proteins were analyzed using MRM-HR, exhibiting high quantitative consistency with the 15-min SWATH method (r = 0.89) in the same sample set. We further verified the capacity of these 75 proteins in separating benign and malignant tissues (AUC = 0.99) in an independent prostate cancer cohort (n=154). Overall our data show that the single-shot short gradient microflow-LC SWATH MS method achieved about 4-fold acceleration of data acquisition with reduced batch effect and a moderate level of protein attrition compared to a standard SWATH acquisition method. Finally, the results showed comparable ability to separate clinical groups.
Open AccessAccelerated Protein Biomarker Discovery from FFPE tissue samples using Single-shot, Short Gradient Microflow SWATH MS
We report and evaluated a microflow, single-shot, short gradient SWATH MS method intended to accelerate the discovery and verification of protein biomarkers in clinical specimens. The method uses 15-min gradient microflow-LC peptide separation, an optimized SWATH MS window configuration and OpenSWATH software for data analysis. We applied the method to a cohort 204 of FFPE prostate tissue samples from 58 prostate cancer patients and 10 prostatic hyperplasia patients. Altogether we identified 27,976 proteotypic peptides and 4,043 SwissProt proteins from these 204 samples. Compared to a reference SWATH method with 2-hour gradient the accelerated method consumed only 27% instrument time, quantified 80% proteins and showed reduced batch effects. 3,800 proteins were quantified by both methods in two different instruments with relatively high consistency (r = 0.77). 75 proteins detected by the accelerated method with differential abundance between clinical groups were selected for further validation. A shortlist of 134 selected peptide precursors from the 75 proteins were analyzed using MRM-HR, exhibiting high quantitative consistency with the 15-min SWATH method (r = 0.89) in the same sample set. We further verified the capacity of these 75 proteins in separating benign and malignant tissues (AUC = 0.99) in an independent prostate cancer cohort (n=154). Overall our data show that the single-shot short gradient microflow-LC SWATH MS method achieved about 4-fold acceleration of data acquisition with reduced batch effect and a moderate level of protein attrition compared to a standard SWATH acquisition method. Finally, the results showed comparable ability to separate clinical groups.