Wanquan Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wanquan Yan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Shing Shin Cheng
The Chinese University of Hong Kong
11 shared publications - Qingpeng Ding
The Chinese University of Hong Kong
8 shared publications - Kim Yan
CUHK, T Stone Robotics Institute and the Department of Mechanical and Automation Engineering, Hong Kong, Hong Kong
7 shared publications - Jianghua Chen
Department of Mechanical and Automation Engineering and T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong
5 shared publications - Jibiao Chen
Department of Mechanical and Automation Engineering and T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong
4 shared publications - Junyan Yan
Department of Mechanical and Automation Engineering and T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong
3 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- p. 1-12
An Active Cooling Method for Fast Actuation of a Millimeter-Scale Shape Memory Alloy-Based Bending Joint
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- p. 1-12
Open AccessAn Active Cooling Method for Fast Actuation of a Millimeter-Scale Shape Memory Alloy-Based Bending Joint
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (5) , 5130-5137
MambaXCTrack: Mamba-Based Tracker With SSM Cross-Correlation and Motion Prompt for Ultrasound Needle Tracking
Ultrasound (US)-guided needle insertion is widely employed in percutaneous interventions. However, providing feedback on the needle tip position via US imaging presents challenges due to noise, artifacts, and the thin imaging plane of US, which degrades needle features and leads to intermittent tip visibility. In this letter, a Mamba-based US needle tracker MambaXCTrack utilizing structured state space models cross-correlation (SSMX-Corr) and implicit motion prompt is proposed, which is the first application of Mamba in US needle tracking. The SSMX-Corr enhances cross-correlation by long-range modeling and global searching of distant semantic features between template and search maps, benefiting the tracking under noise and artifacts by implicitly learning potential distant semantic cues. By combining with cross-map interleaved scan (CIS), local pixel-wise interaction with positional inductive bias can also be introduced to SSMX-Corr. The implicit low-level motion descriptor is proposed as a non-visual prompt to enhance tracking robustness, addressing the intermittent tip visibility problem. Extensive experiments on a dataset with motorized needle insertion in both phantom and tissue samples demonstrate that the proposed tracker outperforms other state-of-the-art trackers while ablation studies further highlight the effectiveness of each proposed tracking module.
- 7 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (5) , 5130-5137
MambaXCTrack: Mamba-Based Tracker With SSM Cross-Correlation and Motion Prompt for Ultrasound Needle Tracking
Ultrasound (US)-guided needle insertion is widely employed in percutaneous interventions. However, providing feedback on the needle tip position via US imaging presents challenges due to noise, artifacts, and the thin imaging plane of US, which degrades needle features and leads to intermittent tip visibility. In this letter, a Mamba-based US needle tracker MambaXCTrack utilizing structured state space models cross-correlation (SSMX-Corr) and implicit motion prompt is proposed, which is the first application of Mamba in US needle tracking. The SSMX-Corr enhances cross-correlation by long-range modeling and global searching of distant semantic features between template and search maps, benefiting the tracking under noise and artifacts by implicitly learning potential distant semantic cues. By combining with cross-map interleaved scan (CIS), local pixel-wise interaction with positional inductive bias can also be introduced to SSMX-Corr. The implicit low-level motion descriptor is proposed as a non-visual prompt to enhance tracking robustness, addressing the intermittent tip visibility problem. Extensive experiments on a dataset with motorized needle insertion in both phantom and tissue samples demonstrate that the proposed tracker outperforms other state-of-the-art trackers while ablation studies further highlight the effectiveness of each proposed tracking module.
- Open Access
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (4) , 1735-1749
Task-Oriented Network Design for Visual Tracking and Motion Filtering of Needle Tip Under 2D Ultrasound
Needle tip tracking under ultrasound (US) imaging is critical for accurate lesion targeting in US-guided percutaneous procedures. While most state-of-the-art trackers have relied on complex network architecture for enhanced performance, the compromised computational efficiency prevents their real-time implementation. Pure visual trackers are also limited in addressing the drift errors caused by temporary needle tip disappearance. In this paper, a compact, task-oriented visual tracker, consisting of an appearance adaptation module and a distractor suppression module, is first designed before it is integrated with a motion filter, namely TransKalman, that leverages the Transformer network for Kalman filter gain estimation. The ablation study shows that the mean tracking success rate (i.e. error <3mm in 95% video frames) of the visual tracker increases by 25% compared with its baseline model. The complete tracking system, integrating the visual tracker and TransKalman, outperforms other existing trackers by at least 5.1% in success rate and 47% in tracking speed during manual needle manipulation experiments in ex-vivo tissue. The proposed real-time tracking system will potentially be integrated in both manual and robotic procedures to reduce operator dependence and improve targeting accuracy during needle-based diagnostic and therapeutic procedures.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (4) , 1735-1749
Open AccessTask-Oriented Network Design for Visual Tracking and Motion Filtering of Needle Tip Under 2D Ultrasound
Needle tip tracking under ultrasound (US) imaging is critical for accurate lesion targeting in US-guided percutaneous procedures. While most state-of-the-art trackers have relied on complex network architecture for enhanced performance, the compromised computational efficiency prevents their real-time implementation. Pure visual trackers are also limited in addressing the drift errors caused by temporary needle tip disappearance. In this paper, a compact, task-oriented visual tracker, consisting of an appearance adaptation module and a distractor suppression module, is first designed before it is integrated with a motion filter, namely TransKalman, that leverages the Transformer network for Kalman filter gain estimation. The ablation study shows that the mean tracking success rate (i.e. error <3mm in 95% video frames) of the visual tracker increases by 25% compared with its baseline model. The complete tracking system, integrating the visual tracker and TransKalman, outperforms other existing trackers by at least 5.1% in success rate and 47% in tracking speed during manual needle manipulation experiments in ex-vivo tissue. The proposed real-time tracking system will potentially be integrated in both manual and robotic procedures to reduce operator dependence and improve targeting accuracy during needle-based diagnostic and therapeutic procedures.
- 23 May 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 88, 102847
Learning-based needle tip tracking in 2D ultrasound by fusing visual tracking and motion prediction
- 23 May 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 88, 102847
Learning-based needle tip tracking in 2D ultrasound by fusing visual tracking and motion prediction
- 27 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (6) , 5902-5913
A High-Performance Modular SMA Actuator With Fast Heating and Active Cooling for Medical Robotics
Shape memory alloy (SMA) has been adopted in medical robotics due to its high power density, compactness, and medical imager compatibility. However, its use in clinical applications remains limited due to its low actuation bandwidth and the lack of proper system integration approaches, leading to poor control accuracy and repeatability. In this article, we report the design, modeling, and characterization of a high-performance SMA actuator for real-time medical robotics application. It uses nichrome wire for fast heating and forced air convection for active cooling to improve the actuation bandwidth, with the SMA spring predisplacements tunable with a simple mechanism. All structures are packaged in a compact module to facilitate practical integration in a robotic system, and enable consistent performance and convenient use. We have also developed an intuitive constitutive model and heat transfer model of the actuator to facilitate selection of its critical parameters, such as SMA predisplacement, heating current, and air pressure, based on the performance requirements. During characterization, the actuator achieved a stroke of 147.2$\mathrm{^{\circ }}$ , stall torque of 172.5 Nmm and actuation bandwidth of 0.43 Hz at$\pm$ 5$\mathrm{^{\circ }}$ rotation amplitude. It also demonstrated high control accuracy (error$< $ 1$\mathrm{^{\circ }}$ ) and high repeatability (standard deviation$< $ 0.16$\mathrm{^{\circ }}$ ) under closed-loop control. Torque–speed relationship was experimentally determined to show its performance under external loading. Finally, the actuator was used to build a steerable endoscope manipulator as a demonstration for real-time application in surgical robotics.- 27 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (6) , 5902-5913
A High-Performance Modular SMA Actuator With Fast Heating and Active Cooling for Medical Robotics
Shape memory alloy (SMA) has been adopted in medical robotics due to its high power density, compactness, and medical imager compatibility. However, its use in clinical applications remains limited due to its low actuation bandwidth and the lack of proper system integration approaches, leading to poor control accuracy and repeatability. In this article, we report the design, modeling, and characterization of a high-performance SMA actuator for real-time medical robotics application. It uses nichrome wire for fast heating and forced air convection for active cooling to improve the actuation bandwidth, with the SMA spring predisplacements tunable with a simple mechanism. All structures are packaged in a compact module to facilitate practical integration in a robotic system, and enable consistent performance and convenient use. We have also developed an intuitive constitutive model and heat transfer model of the actuator to facilitate selection of its critical parameters, such as SMA predisplacement, heating current, and air pressure, based on the performance requirements. During characterization, the actuator achieved a stroke of 147.2$\mathrm{^{\circ }}$ , stall torque of 172.5 Nmm and actuation bandwidth of 0.43 Hz at$\pm$ 5$\mathrm{^{\circ }}$ rotation amplitude. It also demonstrated high control accuracy (error$< $ 1$\mathrm{^{\circ }}$ ) and high repeatability (standard deviation$< $ 0.16$\mathrm{^{\circ }}$ ) under closed-loop control. Torque–speed relationship was experimentally determined to show its performance under external loading. Finally, the actuator was used to build a steerable endoscope manipulator as a demonstration for real-time application in surgical robotics.- 11 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (9) , 2958-2969
A Continuum Robotic Cannula With Tip Following Capability and Distal Dexterity for Intracerebral Hemorrhage Evacuation
Objective: This paper aims to investigate a new continuum robot design and its motion implementation methods appropriate for a minimally invasive intracerebral hemorrhage (ICH) evacuation. Methods: We propose a continuum robotic cannula, consisting of a precurved body and a 2-degree-of-freedom (DoF) flexible tip, monolithically fabricated. Kinematic model with cable elongation model, and a dedicated design optimization and motion planning algorithm were developed to enable the follow-the-leader (FTL) motion of the cannula. A task-dependent Jacobian-based closed loop control was also designed to track the cannula motion during the insertion and its independent tip motion. Results: Comprehensive experiments were conducted to verify the kinematic model and submillimeter motion coupling between the cannula precurved body and its flexible tip. The cannula was also capable of achieving FTL motion within around 2.5 mm shape deviation and control performance within submillimeter errors. It was finally demonstrated to be capable of the nonlinear insertion and tip manipulation in the brain phantom. Conclusion: The new cannula design, together with the proposed algorithms, provides the unique ability to access ICH in a nonlinear trajectory and dexterous tip motion. Significance: These motion capabilities of the robot in such a slender form factor will lead to more complete ICH evacuation and reduced trauma to the healthy brain tissues.
- 11 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (9) , 2958-2969
A Continuum Robotic Cannula With Tip Following Capability and Distal Dexterity for Intracerebral Hemorrhage Evacuation
Objective: This paper aims to investigate a new continuum robot design and its motion implementation methods appropriate for a minimally invasive intracerebral hemorrhage (ICH) evacuation. Methods: We propose a continuum robotic cannula, consisting of a precurved body and a 2-degree-of-freedom (DoF) flexible tip, monolithically fabricated. Kinematic model with cable elongation model, and a dedicated design optimization and motion planning algorithm were developed to enable the follow-the-leader (FTL) motion of the cannula. A task-dependent Jacobian-based closed loop control was also designed to track the cannula motion during the insertion and its independent tip motion. Results: Comprehensive experiments were conducted to verify the kinematic model and submillimeter motion coupling between the cannula precurved body and its flexible tip. The cannula was also capable of achieving FTL motion within around 2.5 mm shape deviation and control performance within submillimeter errors. It was finally demonstrated to be capable of the nonlinear insertion and tip manipulation in the brain phantom. Conclusion: The new cannula design, together with the proposed algorithms, provides the unique ability to access ICH in a nonlinear trajectory and dexterous tip motion. Significance: These motion capabilities of the robot in such a slender form factor will lead to more complete ICH evacuation and reduced trauma to the healthy brain tissues.
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 3835-3842
A Variable Length, Variable Stiffness Flexible Instrument for Transoral Robotic Surgery
Transoral robotic surgery (TORS) in upper aerodigestive tract remains challenging due to the rigidity and insufficient workspace of existing instruments, and inappropriate balance between compliance and stiffness in flexible instruments. In this letter, a flexible surgical robotic instrument, featuring a shape memory alloy (SMA)-based continuously variable length bending joint (CVLBJ), was developed for TORS. The integration of the CVLBJ allows bending length adjustment, leading to enhanced distal workspace compared to traditional fixed length flexible instruments. The instrument also exhibits variable stiffness capability via the length variation of the CVLBJ and the SMA temperature variation. The quasi-static, kinematics, and stiffness model were developed to evaluate quantitatively the instrument workspace and stiffness range. The instrument was experimentally characterized and shown to provide a range of bending configurations suitable for the easily accessible oropharynx and the less accessible larynx, and stiffness range between 0.21 N/m and 1.83 N/m that is sufficiently large for tissue manipulation tasks. The instrument was also demonstrated to be capable of accurate motion tracking, given significant payload and 3D trajectory references. The proposed CVLBJ-integrated flexible instrument offers the variable length and variable stiffness properties missing in existing instruments that could potentially improve the clinical outcomes of TORS.
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 3835-3842
A Variable Length, Variable Stiffness Flexible Instrument for Transoral Robotic Surgery
Transoral robotic surgery (TORS) in upper aerodigestive tract remains challenging due to the rigidity and insufficient workspace of existing instruments, and inappropriate balance between compliance and stiffness in flexible instruments. In this letter, a flexible surgical robotic instrument, featuring a shape memory alloy (SMA)-based continuously variable length bending joint (CVLBJ), was developed for TORS. The integration of the CVLBJ allows bending length adjustment, leading to enhanced distal workspace compared to traditional fixed length flexible instruments. The instrument also exhibits variable stiffness capability via the length variation of the CVLBJ and the SMA temperature variation. The quasi-static, kinematics, and stiffness model were developed to evaluate quantitatively the instrument workspace and stiffness range. The instrument was experimentally characterized and shown to provide a range of bending configurations suitable for the easily accessible oropharynx and the less accessible larynx, and stiffness range between 0.21 N/m and 1.83 N/m that is sufficiently large for tissue manipulation tasks. The instrument was also demonstrated to be capable of accurate motion tracking, given significant payload and 3D trajectory references. The proposed CVLBJ-integrated flexible instrument offers the variable length and variable stiffness properties missing in existing instruments that could potentially improve the clinical outcomes of TORS.
- 16 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 7461-7468
Towards Safe Control of Continuum Manipulator Using Shielded Multiagent Reinforcement Learning
Continuum robotic manipulators are increasingly adopted in minimal invasive surgery. However, their nonlinear behavior is challenging to model accurately, especially when subject to external interaction, potentially leading to poor control performance. In this letter, we investigate the feasibility of adopting a model-free multiagent reinforcement learning (RL), namely multiagent deep Q network (MADQN), to control a 2-degree of freedom (DoF) cable-driven continuum surgical manipulator. The control of the robot is formulated as a one DoF, one agent problem in the MADQN framework to improve the learning efficiency. Combined with a shielding scheme that enables dynamic variation of the action set boundary, MADQN leads to efficient and importantly safer control of the robot. Shielded MADQN enabled the robot to perform point and trajectory tracking with submillimeter root mean square errors under external loads, soft obstacles, and rigid collision, which are common interaction scenarios encountered by surgical manipulators. The controller was further proven to be effective in a miniature continuum robot with high structural nonlinearitiy, achieving trajectory tracking with submillimeter accuracy under external payload.
- 16 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (4) , 7461-7468
Towards Safe Control of Continuum Manipulator Using Shielded Multiagent Reinforcement Learning
Continuum robotic manipulators are increasingly adopted in minimal invasive surgery. However, their nonlinear behavior is challenging to model accurately, especially when subject to external interaction, potentially leading to poor control performance. In this letter, we investigate the feasibility of adopting a model-free multiagent reinforcement learning (RL), namely multiagent deep Q network (MADQN), to control a 2-degree of freedom (DoF) cable-driven continuum surgical manipulator. The control of the robot is formulated as a one DoF, one agent problem in the MADQN framework to improve the learning efficiency. Combined with a shielding scheme that enables dynamic variation of the action set boundary, MADQN leads to efficient and importantly safer control of the robot. Shielded MADQN enabled the robot to perform point and trajectory tracking with submillimeter root mean square errors under external loads, soft obstacles, and rigid collision, which are common interaction scenarios encountered by surgical manipulators. The controller was further proven to be effective in a miniature continuum robot with high structural nonlinearitiy, achieving trajectory tracking with submillimeter accuracy under external payload.
- 2 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 3224-3231
Needle Tip Tracking in 2D Ultrasound Based on Improved Compressive Tracking and Adaptive Kalman Filter
Ultrasound (US) is commonly used in percutaneous needle procedures for real-time guidance. Accurate and robust automatic needle tracking is highly desirable to address the influence of noise and artifacts in US images. This letter presents a tracking approach which combines an improved compressive tracking (ICT) algorithm and a modified Sage-Husa adaptive Kalman filter (SHAKF) to achieve real-time needle tip tracking under 2D US. Estimated needle insertion velocity is used to improve the tracking performance while the high US pixel intensity of the needle tip is used to correct drift. A simplified SHAKF is then implemented to adaptively estimate the statistical characteristics of the noise in the compressive tracking results. An innovation threshold is proposed to improve the response speed of the filter while a normalized cross correlation based method is used to improve the tracking robustness. The proposed tracking approach has been evaluated in in-plane and out-of-plane motions under different insertion speeds and angles in both phantom and tissue experiments. Compared with the original compressive tracking, ICT+Kalman filter, and the template matching algorithm, our proposed approach demonstrates highly accurate tracking performance and high robustness in all cases.
- 2 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 3224-3231
Needle Tip Tracking in 2D Ultrasound Based on Improved Compressive Tracking and Adaptive Kalman Filter
Ultrasound (US) is commonly used in percutaneous needle procedures for real-time guidance. Accurate and robust automatic needle tracking is highly desirable to address the influence of noise and artifacts in US images. This letter presents a tracking approach which combines an improved compressive tracking (ICT) algorithm and a modified Sage-Husa adaptive Kalman filter (SHAKF) to achieve real-time needle tip tracking under 2D US. Estimated needle insertion velocity is used to improve the tracking performance while the high US pixel intensity of the needle tip is used to correct drift. A simplified SHAKF is then implemented to adaptively estimate the statistical characteristics of the noise in the compressive tracking results. An innovation threshold is proposed to improve the response speed of the filter while a normalized cross correlation based method is used to improve the tracking robustness. The proposed tracking approach has been evaluated in in-plane and out-of-plane motions under different insertion speeds and angles in both phantom and tissue experiments. Compared with the original compressive tracking, ICT+Kalman filter, and the template matching algorithm, our proposed approach demonstrates highly accurate tracking performance and high robustness in all cases.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2993-3000
Towards a Wristed Percutaneous Robot With Variable Stiffness for Pericardiocentesis
Pericardiocentesis is the drainage of excessive fluid in the pericardium surrounding the heart under ultrasound guidance. The percutaneous procedure comes with the risk of cardiac perforation since the needle is inserted towards the beating heart. This letter presents a novel percutaneous robot that features a flexible wrist made of shape memory alloy (SMA) spring which can vary its stiffness through temperature variation. The SMA spring can be heated and thus stiffened to allow insertion. At lower temperature, it behaves like a spring backbone that allows the needle to be bent away from the heart and thus minimizing the chance of cardiac perforation. A heating tube made of nichrome wire and PTFE tube was developed to be the heat source for the SMA spring. The robot has an outer diameter of 4 mm, similar to the dilator used in pericardiocentesis, and a lumen to pass a guidewire through. A stiffness model and kinematics model were developed and verified through experiments. The surface temperature of the SMA-based wrist was evaluated to be less than the tissue necrosis temperature. Lastly, we demonstrated that the robot could be inserted into gelatin phantoms of different stiffnesses and produce a wristed motion under ultrasound guidance.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2993-3000
Towards a Wristed Percutaneous Robot With Variable Stiffness for Pericardiocentesis
Pericardiocentesis is the drainage of excessive fluid in the pericardium surrounding the heart under ultrasound guidance. The percutaneous procedure comes with the risk of cardiac perforation since the needle is inserted towards the beating heart. This letter presents a novel percutaneous robot that features a flexible wrist made of shape memory alloy (SMA) spring which can vary its stiffness through temperature variation. The SMA spring can be heated and thus stiffened to allow insertion. At lower temperature, it behaves like a spring backbone that allows the needle to be bent away from the heart and thus minimizing the chance of cardiac perforation. A heating tube made of nichrome wire and PTFE tube was developed to be the heat source for the SMA spring. The robot has an outer diameter of 4 mm, similar to the dilator used in pericardiocentesis, and a lumen to pass a guidewire through. A stiffness model and kinematics model were developed and verified through experiments. The surface temperature of the SMA-based wrist was evaluated to be less than the tissue necrosis temperature. Lastly, we demonstrated that the robot could be inserted into gelatin phantoms of different stiffnesses and produce a wristed motion under ultrasound guidance.