Jianghua Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jianghua Chen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Shing Shin Cheng
The Chinese University of Hong Kong
7 shared publications - Qingpeng Ding
The Chinese University of Hong Kong
6 shared publications - Wanquan Yan
Department of Mechanical and Automation Engineering and T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong
5 shared publications - Kim Yan
CUHK, T Stone Robotics Institute and the Department of Mechanical and Automation Engineering, Hong Kong, Hong Kong
4 shared publications - Jibiao Chen
Department of Mechanical and Automation Engineering and T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong
2 shared publications - Junyan Yan
Department of Mechanical and Automation Engineering and T Stone Robotics Institute, The Chinese University of Hong Kong, Hong Kong
2 shared publications
Latest Publications
- 30 April 2026
- Published by SAGE Publications in Soft Robotics
- Vol. 13 (6) , 889-903
Integrated Multicomponent Modeling and Optimal Design for Antagonistic Shape Memory Alloy Bending Joint
Shape memory alloys (SMAs) are highly suitable for flexible and soft robots due to their lightweight nature, high power density, and miniaturization potential. However, the design of SMA-based continuum bending joints for robotic applications is often restricted by the inherent trade-offs in their mechanical characteristics. In this work, we present an integrated multicomponent framework that encompasses four submodels, including bending angle, load-deflection stiffness, distal twisting angle, and output force for antagonistic SMA wire bending joints. The framework unifies all submodels under a common temperature input set and systematically clarifies their coupled relationships, providing quantitative insight into their trade-offs. A model-based optimal design methodology is then developed for the SMA bending joint, balancing the different mechanical performance metrics to deliver an optimal joint design that satisfies the task requirements. Experiments on the SMA bending joint with optimal design parameters validate the accuracy of various submodels. Two additional nonoptimal prototypes were experimentally evaluated against the optimized design, validating the feasibility of the proposed optimal design methodology. The integrated multicomponent modeling framework and optimal design methodology address the intricate coupling effects inherent in antagonistic SMA wires, minimizing the need for iterative prototyping and facilitating the adoption of SMA wires in flexible and soft robots.
- 30 April 2026
- Published by SAGE Publications in Soft Robotics
- Vol. 13 (6) , 889-903
Integrated Multicomponent Modeling and Optimal Design for Antagonistic Shape Memory Alloy Bending Joint
Shape memory alloys (SMAs) are highly suitable for flexible and soft robots due to their lightweight nature, high power density, and miniaturization potential. However, the design of SMA-based continuum bending joints for robotic applications is often restricted by the inherent trade-offs in their mechanical characteristics. In this work, we present an integrated multicomponent framework that encompasses four submodels, including bending angle, load-deflection stiffness, distal twisting angle, and output force for antagonistic SMA wire bending joints. The framework unifies all submodels under a common temperature input set and systematically clarifies their coupled relationships, providing quantitative insight into their trade-offs. A model-based optimal design methodology is then developed for the SMA bending joint, balancing the different mechanical performance metrics to deliver an optimal joint design that satisfies the task requirements. Experiments on the SMA bending joint with optimal design parameters validate the accuracy of various submodels. Two additional nonoptimal prototypes were experimentally evaluated against the optimized design, validating the feasibility of the proposed optimal design methodology. The integrated multicomponent modeling framework and optimal design methodology address the intricate coupling effects inherent in antagonistic SMA wires, minimizing the need for iterative prototyping and facilitating the adoption of SMA wires in flexible and soft robots.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (12) , 8200-8207
A Cross-Entropy Motion Planning Framework for Hybrid Continuum Robots
The sampling-based motion planners, including the Rapidly-exploring Random Trees (RRT) algorithms, are widely utilized in continuum robots, enabling efficient search for feasible motion plans in constrained environments. In surgical robotics, complex mapping among the high-dimensional kinematics of continuum robots, trajectory parameterization, and path redundancy may lead to non-optimal motion path, which in turn affects their efficiency and surgical task performance (e.g. path following), and ultimately the patient outcome. In this letter, a cross-entropy (CE) motion planning framework is proposed for continuum robots, wherein the RRT * planner is equipped with a CE estimation method serving as a probabilistic model to sample elite trajectories with optimal computation costs. It can asymptotically optimize the sampling distributions among individuals in terms of either robot states or parameterized trajectories. The presented CE motion planners were implemented on a hybrid continuum robot to enable obstacle avoidance, approximate follow-the-leader (FTL) motion, and navigation in a clinical scenario. They are shown to offer lower sampling cost and higher computational efficiency compared to existing approaches.
- 18 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (12) , 8200-8207
A Cross-Entropy Motion Planning Framework for Hybrid Continuum Robots
The sampling-based motion planners, including the Rapidly-exploring Random Trees (RRT) algorithms, are widely utilized in continuum robots, enabling efficient search for feasible motion plans in constrained environments. In surgical robotics, complex mapping among the high-dimensional kinematics of continuum robots, trajectory parameterization, and path redundancy may lead to non-optimal motion path, which in turn affects their efficiency and surgical task performance (e.g. path following), and ultimately the patient outcome. In this letter, a cross-entropy (CE) motion planning framework is proposed for continuum robots, wherein the RRT * planner is equipped with a CE estimation method serving as a probabilistic model to sample elite trajectories with optimal computation costs. It can asymptotically optimize the sampling distributions among individuals in terms of either robot states or parameterized trajectories. The presented CE motion planners were implemented on a hybrid continuum robot to enable obstacle avoidance, approximate follow-the-leader (FTL) motion, and navigation in a clinical scenario. They are shown to offer lower sampling cost and higher computational efficiency compared to existing approaches.
- 23 May 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 88, 102847
Learning-based needle tip tracking in 2D ultrasound by fusing visual tracking and motion prediction
- 23 May 2023
- Published by Elsevier in Medical Image Analysis
- Vol. 88, 102847
Learning-based needle tip tracking in 2D ultrasound by fusing visual tracking and motion prediction
- 27 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (6) , 5902-5913
A High-Performance Modular SMA Actuator With Fast Heating and Active Cooling for Medical Robotics
Shape memory alloy (SMA) has been adopted in medical robotics due to its high power density, compactness, and medical imager compatibility. However, its use in clinical applications remains limited due to its low actuation bandwidth and the lack of proper system integration approaches, leading to poor control accuracy and repeatability. In this article, we report the design, modeling, and characterization of a high-performance SMA actuator for real-time medical robotics application. It uses nichrome wire for fast heating and forced air convection for active cooling to improve the actuation bandwidth, with the SMA spring predisplacements tunable with a simple mechanism. All structures are packaged in a compact module to facilitate practical integration in a robotic system, and enable consistent performance and convenient use. We have also developed an intuitive constitutive model and heat transfer model of the actuator to facilitate selection of its critical parameters, such as SMA predisplacement, heating current, and air pressure, based on the performance requirements. During characterization, the actuator achieved a stroke of 147.2$\mathrm{^{\circ }}$ , stall torque of 172.5 Nmm and actuation bandwidth of 0.43 Hz at$\pm$ 5$\mathrm{^{\circ }}$ rotation amplitude. It also demonstrated high control accuracy (error$< $ 1$\mathrm{^{\circ }}$ ) and high repeatability (standard deviation$< $ 0.16$\mathrm{^{\circ }}$ ) under closed-loop control. Torque–speed relationship was experimentally determined to show its performance under external loading. Finally, the actuator was used to build a steerable endoscope manipulator as a demonstration for real-time application in surgical robotics.- 27 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (6) , 5902-5913
A High-Performance Modular SMA Actuator With Fast Heating and Active Cooling for Medical Robotics
Shape memory alloy (SMA) has been adopted in medical robotics due to its high power density, compactness, and medical imager compatibility. However, its use in clinical applications remains limited due to its low actuation bandwidth and the lack of proper system integration approaches, leading to poor control accuracy and repeatability. In this article, we report the design, modeling, and characterization of a high-performance SMA actuator for real-time medical robotics application. It uses nichrome wire for fast heating and forced air convection for active cooling to improve the actuation bandwidth, with the SMA spring predisplacements tunable with a simple mechanism. All structures are packaged in a compact module to facilitate practical integration in a robotic system, and enable consistent performance and convenient use. We have also developed an intuitive constitutive model and heat transfer model of the actuator to facilitate selection of its critical parameters, such as SMA predisplacement, heating current, and air pressure, based on the performance requirements. During characterization, the actuator achieved a stroke of 147.2$\mathrm{^{\circ }}$ , stall torque of 172.5 Nmm and actuation bandwidth of 0.43 Hz at$\pm$ 5$\mathrm{^{\circ }}$ rotation amplitude. It also demonstrated high control accuracy (error$< $ 1$\mathrm{^{\circ }}$ ) and high repeatability (standard deviation$< $ 0.16$\mathrm{^{\circ }}$ ) under closed-loop control. Torque–speed relationship was experimentally determined to show its performance under external loading. Finally, the actuator was used to build a steerable endoscope manipulator as a demonstration for real-time application in surgical robotics.- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 3835-3842
A Variable Length, Variable Stiffness Flexible Instrument for Transoral Robotic Surgery
Transoral robotic surgery (TORS) in upper aerodigestive tract remains challenging due to the rigidity and insufficient workspace of existing instruments, and inappropriate balance between compliance and stiffness in flexible instruments. In this letter, a flexible surgical robotic instrument, featuring a shape memory alloy (SMA)-based continuously variable length bending joint (CVLBJ), was developed for TORS. The integration of the CVLBJ allows bending length adjustment, leading to enhanced distal workspace compared to traditional fixed length flexible instruments. The instrument also exhibits variable stiffness capability via the length variation of the CVLBJ and the SMA temperature variation. The quasi-static, kinematics, and stiffness model were developed to evaluate quantitatively the instrument workspace and stiffness range. The instrument was experimentally characterized and shown to provide a range of bending configurations suitable for the easily accessible oropharynx and the less accessible larynx, and stiffness range between 0.21 N/m and 1.83 N/m that is sufficiently large for tissue manipulation tasks. The instrument was also demonstrated to be capable of accurate motion tracking, given significant payload and 3D trajectory references. The proposed CVLBJ-integrated flexible instrument offers the variable length and variable stiffness properties missing in existing instruments that could potentially improve the clinical outcomes of TORS.
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (2) , 3835-3842
A Variable Length, Variable Stiffness Flexible Instrument for Transoral Robotic Surgery
Transoral robotic surgery (TORS) in upper aerodigestive tract remains challenging due to the rigidity and insufficient workspace of existing instruments, and inappropriate balance between compliance and stiffness in flexible instruments. In this letter, a flexible surgical robotic instrument, featuring a shape memory alloy (SMA)-based continuously variable length bending joint (CVLBJ), was developed for TORS. The integration of the CVLBJ allows bending length adjustment, leading to enhanced distal workspace compared to traditional fixed length flexible instruments. The instrument also exhibits variable stiffness capability via the length variation of the CVLBJ and the SMA temperature variation. The quasi-static, kinematics, and stiffness model were developed to evaluate quantitatively the instrument workspace and stiffness range. The instrument was experimentally characterized and shown to provide a range of bending configurations suitable for the easily accessible oropharynx and the less accessible larynx, and stiffness range between 0.21 N/m and 1.83 N/m that is sufficiently large for tissue manipulation tasks. The instrument was also demonstrated to be capable of accurate motion tracking, given significant payload and 3D trajectory references. The proposed CVLBJ-integrated flexible instrument offers the variable length and variable stiffness properties missing in existing instruments that could potentially improve the clinical outcomes of TORS.
- 17 September 2021
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 33 (7) , 942-957
Design, modeling and evaluation of a millimeter-scale SMA bending actuator with variable length
Millimeter-scale continuum bending actuators are useful in minimally invasive surgery to allow distal visualization and manipulation outside the line of sight. This paper presents a new continuum bending actuator based on shape memory alloy (SMA) with variable bending length. It consists of two SMA wires antagonistically configured to produce bidirectional bending under Joule heating. A linearly actuated rigid tube along the longitudinal axis enables continuous bending length adjustment, thus enhancing its workspace and force range. The proposed fabrication method tackles the challenging assembly tasks of maintaining the antagonistic configuration of long SMA wires, and robust electrical and mechanical connection during actuation. A quasi-static model of the actuator based on beam model and SMA constitutive model is presented and verified. The bending actuator was evaluated comprehensively for its workspace, blocked force, and trajectory tracking capability at different bending lengths and under different cooling conditions. It is the first work that demonstrates real-time continuous bending length adjustment in SMA-based bending actuator, leading to the potential development of compact and compliant robotic end effectors with improved distal workspace and force.
- 17 September 2021
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 33 (7) , 942-957
Design, modeling and evaluation of a millimeter-scale SMA bending actuator with variable length
Millimeter-scale continuum bending actuators are useful in minimally invasive surgery to allow distal visualization and manipulation outside the line of sight. This paper presents a new continuum bending actuator based on shape memory alloy (SMA) with variable bending length. It consists of two SMA wires antagonistically configured to produce bidirectional bending under Joule heating. A linearly actuated rigid tube along the longitudinal axis enables continuous bending length adjustment, thus enhancing its workspace and force range. The proposed fabrication method tackles the challenging assembly tasks of maintaining the antagonistic configuration of long SMA wires, and robust electrical and mechanical connection during actuation. A quasi-static model of the actuator based on beam model and SMA constitutive model is presented and verified. The bending actuator was evaluated comprehensively for its workspace, blocked force, and trajectory tracking capability at different bending lengths and under different cooling conditions. It is the first work that demonstrates real-time continuous bending length adjustment in SMA-based bending actuator, leading to the potential development of compact and compliant robotic end effectors with improved distal workspace and force.
- 2 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 3224-3231
Needle Tip Tracking in 2D Ultrasound Based on Improved Compressive Tracking and Adaptive Kalman Filter
Ultrasound (US) is commonly used in percutaneous needle procedures for real-time guidance. Accurate and robust automatic needle tracking is highly desirable to address the influence of noise and artifacts in US images. This letter presents a tracking approach which combines an improved compressive tracking (ICT) algorithm and a modified Sage-Husa adaptive Kalman filter (SHAKF) to achieve real-time needle tip tracking under 2D US. Estimated needle insertion velocity is used to improve the tracking performance while the high US pixel intensity of the needle tip is used to correct drift. A simplified SHAKF is then implemented to adaptively estimate the statistical characteristics of the noise in the compressive tracking results. An innovation threshold is proposed to improve the response speed of the filter while a normalized cross correlation based method is used to improve the tracking robustness. The proposed tracking approach has been evaluated in in-plane and out-of-plane motions under different insertion speeds and angles in both phantom and tissue experiments. Compared with the original compressive tracking, ICT+Kalman filter, and the template matching algorithm, our proposed approach demonstrates highly accurate tracking performance and high robustness in all cases.
- 2 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 3224-3231
Needle Tip Tracking in 2D Ultrasound Based on Improved Compressive Tracking and Adaptive Kalman Filter
Ultrasound (US) is commonly used in percutaneous needle procedures for real-time guidance. Accurate and robust automatic needle tracking is highly desirable to address the influence of noise and artifacts in US images. This letter presents a tracking approach which combines an improved compressive tracking (ICT) algorithm and a modified Sage-Husa adaptive Kalman filter (SHAKF) to achieve real-time needle tip tracking under 2D US. Estimated needle insertion velocity is used to improve the tracking performance while the high US pixel intensity of the needle tip is used to correct drift. A simplified SHAKF is then implemented to adaptively estimate the statistical characteristics of the noise in the compressive tracking results. An innovation threshold is proposed to improve the response speed of the filter while a normalized cross correlation based method is used to improve the tracking robustness. The proposed tracking approach has been evaluated in in-plane and out-of-plane motions under different insertion speeds and angles in both phantom and tissue experiments. Compared with the original compressive tracking, ICT+Kalman filter, and the template matching algorithm, our proposed approach demonstrates highly accurate tracking performance and high robustness in all cases.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2993-3000
Towards a Wristed Percutaneous Robot With Variable Stiffness for Pericardiocentesis
Pericardiocentesis is the drainage of excessive fluid in the pericardium surrounding the heart under ultrasound guidance. The percutaneous procedure comes with the risk of cardiac perforation since the needle is inserted towards the beating heart. This letter presents a novel percutaneous robot that features a flexible wrist made of shape memory alloy (SMA) spring which can vary its stiffness through temperature variation. The SMA spring can be heated and thus stiffened to allow insertion. At lower temperature, it behaves like a spring backbone that allows the needle to be bent away from the heart and thus minimizing the chance of cardiac perforation. A heating tube made of nichrome wire and PTFE tube was developed to be the heat source for the SMA spring. The robot has an outer diameter of 4 mm, similar to the dilator used in pericardiocentesis, and a lumen to pass a guidewire through. A stiffness model and kinematics model were developed and verified through experiments. The surface temperature of the SMA-based wrist was evaluated to be less than the tissue necrosis temperature. Lastly, we demonstrated that the robot could be inserted into gelatin phantoms of different stiffnesses and produce a wristed motion under ultrasound guidance.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 6 (2) , 2993-3000
Towards a Wristed Percutaneous Robot With Variable Stiffness for Pericardiocentesis
Pericardiocentesis is the drainage of excessive fluid in the pericardium surrounding the heart under ultrasound guidance. The percutaneous procedure comes with the risk of cardiac perforation since the needle is inserted towards the beating heart. This letter presents a novel percutaneous robot that features a flexible wrist made of shape memory alloy (SMA) spring which can vary its stiffness through temperature variation. The SMA spring can be heated and thus stiffened to allow insertion. At lower temperature, it behaves like a spring backbone that allows the needle to be bent away from the heart and thus minimizing the chance of cardiac perforation. A heating tube made of nichrome wire and PTFE tube was developed to be the heat source for the SMA spring. The robot has an outer diameter of 4 mm, similar to the dilator used in pericardiocentesis, and a lumen to pass a guidewire through. A stiffness model and kinematics model were developed and verified through experiments. The surface temperature of the SMA-based wrist was evaluated to be less than the tissue necrosis temperature. Lastly, we demonstrated that the robot could be inserted into gelatin phantoms of different stiffnesses and produce a wristed motion under ultrasound guidance.