Abstract
Pericardiocentesis is the drainage of excessive fluid in the pericardium surrounding the heart under ultrasound guidance. The percutaneous procedure comes with the risk of cardiac perforation since the needle is inserted towards the beating heart. This letter presents a novel percutaneous robot that features a flexible wrist made of shape memory alloy (SMA) spring which can vary its stiffness through temperature variation. The SMA spring can be heated and thus stiffened to allow insertion. At lower temperature, it behaves like a spring backbone that allows the needle to be bent away from the heart and thus minimizing the chance of cardiac perforation. A heating tube made of nichrome wire and PTFE tube was developed to be the heat source for the SMA spring. The robot has an outer diameter of 4 mm, similar to the dilator used in pericardiocentesis, and a lumen to pass a guidewire through. A stiffness model and kinematics model were developed and verified through experiments. The surface temperature of the SMA-based wrist was evaluated to be less than the tissue necrosis temperature. Lastly, we demonstrated that the robot could be inserted into gelatin phantoms of different stiffnesses and produce a wristed motion under ultrasound guidance.Keywords
Funding Information
- Innovation and Technology Commission (ITS/389/18)
- Research Grants Council (CUHK 24201219)
- Chinese University of Hong Kong
- VC Fund (4930807)
- CUHK T Stone Robotics Institute
- University of Sydney (BME-p7-20)
- Shun Hing Institute of Advanced Engineering
This publication has 32 references indexed in Scilit:
- A Novel Discretely Actuated Steerable Probe for Percutaneous Procedures2014
- Robot-assisted automatic insertion of steerable needles with closed-loop imaging feedback and intraoperative trajectory replanningMechatronics, 2013
- A Flexure-Based Steerable Needle: High Curvature With Reduced Tissue DamageIEEE Transactions on Biomedical Engineering, 2012
- Management of pericardial effusionEuropean Heart Journal, 2012
- Thresholds for thermal damage to normal tissues: An updateInternational Journal of Hyperthermia, 2011
- Nonholonomic Modeling of Needle SteeringThe International Journal of Robotics Research, 2006
- Hand-Held Steerable Needle DeviceIEEE/ASME Transactions on Mechatronics, 2005
- Effect of the composition and thermal annealing on the transformation temperatures of sputtered TiNi shape memory alloy thin filmsThin Solid Films, 2001
- One-Dimensional Constitutive Behavior of Shape Memory Alloys: Thermomechanical Derivation with Non-Constant Material Functions and Redefined Martensite Internal VariableJournal of Intelligent Material Systems and Structures, 1993
- The PericardiumThe Annals of Thoracic Surgery, 1972