Zhengbo Cheng
Research Subjects
Research Interests
Zhengbo Cheng has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Yi Tan
Department of Engineering Physics, Tsinghua University, Beijing, China
4 shared publications - Zhe Gao
Tsinghua University
4 shared publications - Binbin Wang
Shaanxi Startorus Fusion Technology Company, Ltd., Shaanxi, China
3 shared publications - Long Zeng
Tsinghua University
3 shared publications Yi Tan
Department of Engineering Physics, Tsinghua University, Beijing 100084, People’s Republic of China
3 shared publications- Zichong Song
Department of Engineering Physics, Tsinghua University, Beijing, China
3 shared publications
Latest Publications
- 30 October 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (11) , 115002
Preliminary progress of magnetic plasma control for the SUNIST-2 spherical tokamak
Plasma control is a comprehensive physical and technological problem that is critical for tokamak operation. This article presents the initial advancements related to plasma magnetic control for the SUNIST-2 spherical tokamak. The fundamental architecture for control and operation is introduced, focusing on diagnostics, power supplies, real-time server/network and integrated code toolbox. The feedforward equilibrium design and feedback controller design workflows are also introduced. A variety of configurations were tested in the finished experiments on the SUNIST-2. For example, negative triangularity plasma has been achieved using the designed feedforward coil current waveforms. Preliminary tests of plasma position and plasma current feedback controllers were also successful. These results verified the reliability of the infrastructure and operational workflow. Future plans for improving the SUNIST-2 plasma control ability are also briefly discussed.
- 30 October 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (11) , 115002
Preliminary progress of magnetic plasma control for the SUNIST-2 spherical tokamak
Plasma control is a comprehensive physical and technological problem that is critical for tokamak operation. This article presents the initial advancements related to plasma magnetic control for the SUNIST-2 spherical tokamak. The fundamental architecture for control and operation is introduced, focusing on diagnostics, power supplies, real-time server/network and integrated code toolbox. The feedforward equilibrium design and feedback controller design workflows are also introduced. A variety of configurations were tested in the finished experiments on the SUNIST-2. For example, negative triangularity plasma has been achieved using the designed feedforward coil current waveforms. Preliminary tests of plasma position and plasma current feedback controllers were also successful. These results verified the reliability of the infrastructure and operational workflow. Future plans for improving the SUNIST-2 plasma control ability are also briefly discussed.
- 7 July 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (7) , 075023
First results of lithium coating experiments in the SUNIST-2 spherical tokamak
Lithium coating is applied for wall conditioning in the Sino-UNIted Spherical Tokamak-2. Two movable evaporators are installed on the equatorial plane to evaporate lithium. A novel method to handle lithium is used in this paper. Before lithium coating, stainless steel foils are put up to cover almost all of the wall except for the graphite limiter, making it extremely easy to clean lithium after experiment. Following lithium coating, the water and carbon dioxide in residual gases are reduced by more than half, and the carbon, oxygen, and nitrogen impurities during discharge are reduced by one order of magnitude. During the merging compression startup, an enhancement of ion heating is observed and attributed to a 30% increase in the total plasma current. In ohmic discharges, the energy confinement time is observed to exceed the linear ohmic confinement within the lithium wall.
- 7 July 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (7) , 075023
First results of lithium coating experiments in the SUNIST-2 spherical tokamak
Lithium coating is applied for wall conditioning in the Sino-UNIted Spherical Tokamak-2. Two movable evaporators are installed on the equatorial plane to evaporate lithium. A novel method to handle lithium is used in this paper. Before lithium coating, stainless steel foils are put up to cover almost all of the wall except for the graphite limiter, making it extremely easy to clean lithium after experiment. Following lithium coating, the water and carbon dioxide in residual gases are reduced by more than half, and the carbon, oxygen, and nitrogen impurities during discharge are reduced by one order of magnitude. During the merging compression startup, an enhancement of ion heating is observed and attributed to a 30% increase in the total plasma current. In ohmic discharges, the energy confinement time is observed to exceed the linear ohmic confinement within the lithium wall.
- Open Access
- 14 May 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (6) , 066017
Development of plasma burn-through simulation code and validation in SUNIST-2 and EAST
A full electromagnetic plasma burn-through simulation code has been developed to improve understanding of the plasma breakdown and initiation process in tokamaks, including spherical tokamaks. A 0D plasma model is adopted in the model, with only operation signals as input, such as current waveforms of central solenoid coils and poloidal field coils, prefill gas pressure and parameters for wall conditioning, which are determined before discharge experiments. The output includes the time evolution of the plasma current, electron temperature, ion temperature, and densities of gas compositions. The simulation code mainly contains three parts: circuit equations, energy balances, and particle balances. Eddy currents on toroidal passive conducting units of vacuum vessel and plasma current are calculated simultaneously by solving circuit equations. The use of eddy current waveforms and coil current waveforms enables calculation of the 2D space distribution of time-evolving poloidal magnetic field and flux, and consequently the plasma volume evolution can be calculated using the last closed flux surface. Energy balances and particle balances are used to solve the temperature and density evolution of fuel gas and impurities. The main procedures in energy balances and particle balances are ionization, recombination, charge exchange, radiation, and transport. Transport loss is estimated by perpendicular loss by Bohm diffusion and parallel loss along field lines, which is calculated using connection length and ion sound speed. The connection length is calculated using magnetic field line tracing with electromagnetic modeling. The code has been used to reproduce the time evolution of plasma current, electron density, flux loop data, and H α or D α data of plasma burn-through on SUNIST-2 spherical tokamak and EAST tokamak, and the simulated results are consistent with experimental measurements with the relative errors of the plasma current, loop voltage, and magnetic flux under 15%.
- 14 May 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (6) , 066017
Open AccessDevelopment of plasma burn-through simulation code and validation in SUNIST-2 and EAST
A full electromagnetic plasma burn-through simulation code has been developed to improve understanding of the plasma breakdown and initiation process in tokamaks, including spherical tokamaks. A 0D plasma model is adopted in the model, with only operation signals as input, such as current waveforms of central solenoid coils and poloidal field coils, prefill gas pressure and parameters for wall conditioning, which are determined before discharge experiments. The output includes the time evolution of the plasma current, electron temperature, ion temperature, and densities of gas compositions. The simulation code mainly contains three parts: circuit equations, energy balances, and particle balances. Eddy currents on toroidal passive conducting units of vacuum vessel and plasma current are calculated simultaneously by solving circuit equations. The use of eddy current waveforms and coil current waveforms enables calculation of the 2D space distribution of time-evolving poloidal magnetic field and flux, and consequently the plasma volume evolution can be calculated using the last closed flux surface. Energy balances and particle balances are used to solve the temperature and density evolution of fuel gas and impurities. The main procedures in energy balances and particle balances are ionization, recombination, charge exchange, radiation, and transport. Transport loss is estimated by perpendicular loss by Bohm diffusion and parallel loss along field lines, which is calculated using connection length and ion sound speed. The connection length is calculated using magnetic field line tracing with electromagnetic modeling. The code has been used to reproduce the time evolution of plasma current, electron density, flux loop data, and H α or D α data of plasma burn-through on SUNIST-2 spherical tokamak and EAST tokamak, and the simulated results are consistent with experimental measurements with the relative errors of the plasma current, loop voltage, and magnetic flux under 15%.
- 17 February 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 213
Equilibrium reconstruction in the Sino-United spherical tokamak
- 17 February 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 213
Equilibrium reconstruction in the Sino-United spherical tokamak
- Open Access
- 1 June 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (6)
Compressive sensing-based tomography for Absolute X-ray UltraViolet (AXUV) diagnostics
Absolute x-ray ultraviolet diagnostics ensures 2D coverage of the radiation emission region that enables tomographic reconstruction. However, retrieving the local emissivity via tomography remains a challenge due to its ill-posed nature. Tikhonov regularization with smoothness operation generally performs well but tends to over-smooth regions with steep gradients and local structure in the radiation profile and may introduce artifacts. In this paper, a tomography method based on compressive sensing theory with Tikhonov regularization terms is developed. Experimental results on multiple phantom sets show that the proposed method improves the reconstruction accuracy and quality in regions with steep gradients compared with the Tikhonov regularization method and suppresses the unphysical negative emissivity. The analysis of reconstruction uncertainty shows that the dictionary learning process provides more accurate prior information about steep gradients to improve the quality of reconstructed images, and compressive sensing has the denoising capability to reduce the impact of noise. Finally, the method is validated by data from the Sino-UNIted Spherical Tokamak, showing fewer artifacts and more reliable reconstruction images than the earlier method.
- 1 June 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (6)
Open AccessCompressive sensing-based tomography for Absolute X-ray UltraViolet (AXUV) diagnostics
Absolute x-ray ultraviolet diagnostics ensures 2D coverage of the radiation emission region that enables tomographic reconstruction. However, retrieving the local emissivity via tomography remains a challenge due to its ill-posed nature. Tikhonov regularization with smoothness operation generally performs well but tends to over-smooth regions with steep gradients and local structure in the radiation profile and may introduce artifacts. In this paper, a tomography method based on compressive sensing theory with Tikhonov regularization terms is developed. Experimental results on multiple phantom sets show that the proposed method improves the reconstruction accuracy and quality in regions with steep gradients compared with the Tikhonov regularization method and suppresses the unphysical negative emissivity. The analysis of reconstruction uncertainty shows that the dictionary learning process provides more accurate prior information about steep gradients to improve the quality of reconstructed images, and compressive sensing has the denoising capability to reduce the impact of noise. Finally, the method is validated by data from the Sino-UNIted Spherical Tokamak, showing fewer artifacts and more reliable reconstruction images than the earlier method.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053518
Development of a thin high-frequency and high-precision magnetic probe array in Sino-United Spherical Tokamak
Since the major/minor radius of the Sino-United Spherical Tokamak (SUNIST) is 0.3/0.23 m, respectively, the space left for magnetic diagnostics in the high field side (HFS) is quite limited. At the same time, a good signal-to-noise ratio and a high-frequency response (up to 1 MHz) are required for equilibrium reconstruction (ER) and Alfven eigenmode studies. Such a magnetic probe array must be extremely thin and tightly close to the central column, not exceeding the inner limiter and leaving the aspect ratio of the spherical tokamak unchanged. Therefore, the turn number and the shape of windings should be highly optimized to enable both a high-frequency response and an enough effective area. A 32-channel magnetic probe array fulfilling these requirements on the central column is designed, calibrated, and installed in the SUNIST. The array consists of 16 probes. Each of them consists of two perpendicular windings, which can measure toroidal and poloidal magnetic fields simultaneously. The effective area and frequency response of each probe are calibrated using a Helmholtz coil and an LCR bridge based on an equivalent probe-and-cable circuit model. After that, an expression of the magnetic diagnostic response to the field coil currents is used to calibrate the installation error. With the full coverage of magnetic probes in the poloidal direction, more reliable ER can be obtained, and the features of magnetohydrodynamic activities in the HFS can be studied.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053518
Development of a thin high-frequency and high-precision magnetic probe array in Sino-United Spherical Tokamak
Since the major/minor radius of the Sino-United Spherical Tokamak (SUNIST) is 0.3/0.23 m, respectively, the space left for magnetic diagnostics in the high field side (HFS) is quite limited. At the same time, a good signal-to-noise ratio and a high-frequency response (up to 1 MHz) are required for equilibrium reconstruction (ER) and Alfven eigenmode studies. Such a magnetic probe array must be extremely thin and tightly close to the central column, not exceeding the inner limiter and leaving the aspect ratio of the spherical tokamak unchanged. Therefore, the turn number and the shape of windings should be highly optimized to enable both a high-frequency response and an enough effective area. A 32-channel magnetic probe array fulfilling these requirements on the central column is designed, calibrated, and installed in the SUNIST. The array consists of 16 probes. Each of them consists of two perpendicular windings, which can measure toroidal and poloidal magnetic fields simultaneously. The effective area and frequency response of each probe are calibrated using a Helmholtz coil and an LCR bridge based on an equivalent probe-and-cable circuit model. After that, an expression of the magnetic diagnostic response to the field coil currents is used to calibrate the installation error. With the full coverage of magnetic probes in the poloidal direction, more reliable ER can be obtained, and the features of magnetohydrodynamic activities in the HFS can be studied.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043538
Implementation and data processing of a five-channel microwave interferometer with high temporal resolution and low noise on Sino-UNIted Spherical Tokamak
A five-channel microwave interferometer with high temporal resolution and high phase resolution has been developed for measuring electron density profiles and fluctuations on the Sino-UNIted Spherical Tokamak. A correction algorithm, based on the low signal amplitude detection, is proposed to eliminate the fringe jump errors. The correction algorithm achieves an accuracy of 92%. The density profile is reconstructed through the Park-matrix method, with the geometry of magnetic surfaces calculated by the equilibrium fitting. The reconstructed density profiles for discharges with supersonic molecular beam injection are in good agreement with the results of another 94 GHz single-channel horizontal interferometer and the Langmuir probes. The temporal resolution of the system is 0.5 µs and the line-integrated electron density resolution is 1 × 1015 m−2, which benefits from the single sideband modulation technique. Therefore, the multichannel interferometer system is capable of studying the details of the high-frequency (up to 200 kHz) density fluctuation such as that in the minor disruption event.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043538
Implementation and data processing of a five-channel microwave interferometer with high temporal resolution and low noise on Sino-UNIted Spherical Tokamak
A five-channel microwave interferometer with high temporal resolution and high phase resolution has been developed for measuring electron density profiles and fluctuations on the Sino-UNIted Spherical Tokamak. A correction algorithm, based on the low signal amplitude detection, is proposed to eliminate the fringe jump errors. The correction algorithm achieves an accuracy of 92%. The density profile is reconstructed through the Park-matrix method, with the geometry of magnetic surfaces calculated by the equilibrium fitting. The reconstructed density profiles for discharges with supersonic molecular beam injection are in good agreement with the results of another 94 GHz single-channel horizontal interferometer and the Langmuir probes. The temporal resolution of the system is 0.5 µs and the line-integrated electron density resolution is 1 × 1015 m−2, which benefits from the single sideband modulation technique. Therefore, the multichannel interferometer system is capable of studying the details of the high-frequency (up to 200 kHz) density fluctuation such as that in the minor disruption event.