Joshua Cysyk
Joshua Cysyk has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Gerson Rosenberg
From the *Department of Surgery, Penn State College of Medicine, Hershey, PA
4 shared publicationsRay Newswanger
From the *Department of Surgery, Penn State College of Medicine, Hershey, PA
4 shared publicationsWilliam Weiss
From the *Department of Surgery, Penn State College of Medicine, Hershey, PA
4 shared publicationsChoon-Sik Jhun
Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
3 shared publicationsJohn Reibson
From the *Department of Surgery, Penn State College of Medicine, Hershey, PA
3 shared publicationsBradley Doxtater
Department of Surgery, The Pennsylvania State University, College of Medicine, Hershey, Pennsylvania
2 shared publications
Latest Publications
- 1 October 2022
- Published by Springer Nature in Journal of Science Education and Technology
- Vol. 32 (1) , 96-110
Examining Science and Technology/Engineering Educators’ Views of Teaching Biomedical Concepts Through Physical Computing
Programming and automation continue to evolve rapidly and advance the capabilities of science, technology, engineering, and mathematics (STEM) fields. However, physical computing (the integration of programming and interactive physical devices) integrated within biomedical contexts remains an area of limited focus in secondary STEM education programs. As this is an emerging area, many educators may not be well prepared to teach physical computing concepts within authentic biomedical contexts. This shortcoming provided the rationale for this study, to examine if professional development (PD) had a noticeable influence on high school science and technology and engineering (T&E) teachers’ (1) perceptions of teaching biomedical and computational thinking (CT) concepts and (2) plans to integrate physical computing within the context of authentic biomedical engineering challenges. The findings revealed a significant difference in the amount of biomedical and CT concepts that teachers planned to implement as a result of the PD. Using a modified version of the Science Teaching Efficacy Belief Instrument (STEBI-A) Riggs and Enochs in Science Education, 74(6), 625–637 (1990), analyses revealed significant gains in teachers’ self-efficacy toward teaching both biomedical and CT concepts from the PD. Further analyses revealed that teachers reported increases in their perceived knowledge of biomedical and CT concepts and a significant increase in their intent to collaborate with a science or T&E educator outside of their content area. This study provides implications for researchers and educators to integrate more biomedical and physical computing instruction at the secondary education level.
- 1 October 2022
- Published by Springer Nature in Journal of Science Education and Technology
- Vol. 32 (1) , 96-110
Examining Science and Technology/Engineering Educators’ Views of Teaching Biomedical Concepts Through Physical Computing
Programming and automation continue to evolve rapidly and advance the capabilities of science, technology, engineering, and mathematics (STEM) fields. However, physical computing (the integration of programming and interactive physical devices) integrated within biomedical contexts remains an area of limited focus in secondary STEM education programs. As this is an emerging area, many educators may not be well prepared to teach physical computing concepts within authentic biomedical contexts. This shortcoming provided the rationale for this study, to examine if professional development (PD) had a noticeable influence on high school science and technology and engineering (T&E) teachers’ (1) perceptions of teaching biomedical and computational thinking (CT) concepts and (2) plans to integrate physical computing within the context of authentic biomedical engineering challenges. The findings revealed a significant difference in the amount of biomedical and CT concepts that teachers planned to implement as a result of the PD. Using a modified version of the Science Teaching Efficacy Belief Instrument (STEBI-A) Riggs and Enochs in Science Education, 74(6), 625–637 (1990), analyses revealed significant gains in teachers’ self-efficacy toward teaching both biomedical and CT concepts from the PD. Further analyses revealed that teachers reported increases in their perceived knowledge of biomedical and CT concepts and a significant increase in their intent to collaborate with a science or T&E educator outside of their content area. This study provides implications for researchers and educators to integrate more biomedical and physical computing instruction at the secondary education level.
- 1 June 2022
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (6) , 791-799
In Vivo Evaluation of a Physiologic Control System for Rotary Blood Pumps Based on the Left Ventricular Pressure-Volume Loop
Current generation continuous flow assist devices to operate at a fixed speed, which limits preload response and exercise capacity in left ventricular assist device (LVAD) patients. A feedback control system was developed to automatically adjust pump speed based on direct measurements of ventricular loading using a custom cannula tip with an integrated pressure sensor and volume-sensing conductance electrodes. The input to the control system is the integral of the left ventricular (LV) pressure versus conductance loop (PGA) over each cardiac cycle. The feedback control system adjusts pump speed based on the difference between the measured PGA and the desired PGA. The control system and cannula tip were tested in acute ovine studies (n = 5) using the HeartMate II LVAD. The preload response of the control system was evaluated by partially occluding and releasing the inferior vena cava using a vessel loop snare. The cannula tip was integrated onto a custom centrifugal flow LVAD and tested in a 14-day bovine study. The control system adjusted pump support to maintain constant ventricular loading: pump speed increased (decreased) following an increase (decrease) in preload. This study demonstrated in vivo the Starling-like response of an automatic pump control system based on direct measurements of LV loading.
- 1 June 2022
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (6) , 791-799
In Vivo Evaluation of a Physiologic Control System for Rotary Blood Pumps Based on the Left Ventricular Pressure-Volume Loop
Current generation continuous flow assist devices to operate at a fixed speed, which limits preload response and exercise capacity in left ventricular assist device (LVAD) patients. A feedback control system was developed to automatically adjust pump speed based on direct measurements of ventricular loading using a custom cannula tip with an integrated pressure sensor and volume-sensing conductance electrodes. The input to the control system is the integral of the left ventricular (LV) pressure versus conductance loop (PGA) over each cardiac cycle. The feedback control system adjusts pump speed based on the difference between the measured PGA and the desired PGA. The control system and cannula tip were tested in acute ovine studies (n = 5) using the HeartMate II LVAD. The preload response of the control system was evaluated by partially occluding and releasing the inferior vena cava using a vessel loop snare. The cannula tip was integrated onto a custom centrifugal flow LVAD and tested in a 14-day bovine study. The control system adjusted pump support to maintain constant ventricular loading: pump speed increased (decreased) following an increase (decrease) in preload. This study demonstrated in vivo the Starling-like response of an automatic pump control system based on direct measurements of LV loading.
- 19 April 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (11) , 1240-1249
Miniaturized Fontan Circulation Assist Device: Chronic In Vivo Evaluation
We have miniaturized and optimized our implantable rotary blood pump developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the miniaturized Fontan circulation assist device (mini-FCAD) during 30-day sheep studies (n = 5). A complete right heart bypass was performed and all return flow was supported by the pump. Postoperatively, unfractionated heparin was given to maintain thromboelastography R times of 2× normal. The first two studies were terminated on day 0 and day 4 due to complications. In the final three studies, the animals remained healthy and were electively terminated at 30 ± 2 days. Pump flow was between 5 and 7 lpm, left atrial pressure remained normal, and inlet pressures were between 3 and 18 mm Hg with no incidents of suction. There was no evidence of hemolysis, end organ or pulmonary dysfunction, thromboembolic events, nor thermal damage to the surrounding tissue. Explanted devices from two studies were free of thrombi and in the third study there were unattached thrombi on the SVC inlet of the rotor. The mini-FCAD was successfully tested in vivo as a right heart replacement device demonstrating adequate circulatory support and normal physiologic pulmonary and venous pressures.
- 19 April 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (11) , 1240-1249
Miniaturized Fontan Circulation Assist Device: Chronic In Vivo Evaluation
We have miniaturized and optimized our implantable rotary blood pump developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the miniaturized Fontan circulation assist device (mini-FCAD) during 30-day sheep studies (n = 5). A complete right heart bypass was performed and all return flow was supported by the pump. Postoperatively, unfractionated heparin was given to maintain thromboelastography R times of 2× normal. The first two studies were terminated on day 0 and day 4 due to complications. In the final three studies, the animals remained healthy and were electively terminated at 30 ± 2 days. Pump flow was between 5 and 7 lpm, left atrial pressure remained normal, and inlet pressures were between 3 and 18 mm Hg with no incidents of suction. There was no evidence of hemolysis, end organ or pulmonary dysfunction, thromboembolic events, nor thermal damage to the surrounding tissue. Explanted devices from two studies were free of thrombi and in the third study there were unattached thrombi on the SVC inlet of the rotor. The mini-FCAD was successfully tested in vivo as a right heart replacement device demonstrating adequate circulatory support and normal physiologic pulmonary and venous pressures.
- 1 August 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (6) , 593-600
Chronic In Vivo Test of a Right Heart Replacement Blood Pump for Failed Fontan Circulation
An implantable rotary blood pump was developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the pump in vivo in a 30 day sheep study. Pump speed was set at 3,900 rpm for the duration of the study, and pump power was between 4.3 and 4.6 W. The pump inlet pressures for the superior vena cava (SVC) and inferior vena cava (IVC) were 14 ± 15 and 11 ± 15 mm Hg, respectively, over the duration of the study. Hematocrit remained stable at 30% ± 4%. Partial thromboplastin time (PTT) steadily increased from 30 s preoperatively to a high of 59 s on postoperative day 20, while prothrombin time (PT) remained at 20 ± 2 s for the duration of the study. The implantation and postoperative recovery were successful, and the animal demonstrated normal physiologic pulmonary and venous pressures and cardiac output. On pump inspection, the IVC and SVC inlets were completely clear of any deposits, but there were small thrombi (approximately 0.5 mm diameter) between each of the three rotor blades and along 20% of the parting line of the two volute halves. A complete right heart bypass was performed, postoperative recovery was successful, and the pump demonstrated adequate circulatory support and normal physiologic pulmonary and venous pressures. This study was the first successful test of a right heart replacement device in a chronic animal study.
- 1 August 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (6) , 593-600
Chronic In Vivo Test of a Right Heart Replacement Blood Pump for Failed Fontan Circulation
An implantable rotary blood pump was developed to provide long-term mechanical right heart support for patients who have failing Fontan circulation. The objective of this study was to evaluate the pump in vivo in a 30 day sheep study. Pump speed was set at 3,900 rpm for the duration of the study, and pump power was between 4.3 and 4.6 W. The pump inlet pressures for the superior vena cava (SVC) and inferior vena cava (IVC) were 14 ± 15 and 11 ± 15 mm Hg, respectively, over the duration of the study. Hematocrit remained stable at 30% ± 4%. Partial thromboplastin time (PTT) steadily increased from 30 s preoperatively to a high of 59 s on postoperative day 20, while prothrombin time (PT) remained at 20 ± 2 s for the duration of the study. The implantation and postoperative recovery were successful, and the animal demonstrated normal physiologic pulmonary and venous pressures and cardiac output. On pump inspection, the IVC and SVC inlets were completely clear of any deposits, but there were small thrombi (approximately 0.5 mm diameter) between each of the three rotor blades and along 20% of the parting line of the two volute halves. A complete right heart bypass was performed, postoperative recovery was successful, and the pump demonstrated adequate circulatory support and normal physiologic pulmonary and venous pressures. This study was the first successful test of a right heart replacement device in a chronic animal study.
- 1 May 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (4) , 318-323
Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.
- 1 May 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (4) , 318-323
Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development
The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.