Jasmine Vu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jasmine Vu has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Laleh Golestanirad
Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
5 shared publications Bhumi Bhusal
Northwestern University,Feinberg School of Medicine,Department of Radiology,Chicago,IL,USA
4 shared publications- Bhumi Bhusal
Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
4 shared publications Joshua Rosenow
Northwestern University,Feinberg School of Medicine,Department of Neurosurgery,Chicago,IL,USA
3 shared publicationsLaleh Golestanirad
Northwestern University,McCormick School of Engineering,Department of Biomedical Engineering,Evanston,IL,USA
3 shared publicationsBach T. Nguyen
Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
2 shared publications
Latest Publications
- Open Access
Cumulative Transfer Function for Assessment of MRI-Induced RF Heating Risk in Pediatric Patients Implanted with Bifurcated Leads
Purpose: RF-induced heating remains a major barrier to MRI access for patients with epicardial cardiac implantable electronic devices (CIEDs). Although ISO/TS 10974 Tier-3 transfer function (TF) methods are established for unbranched leads, no analogous framework exists for bifurcated leads, in which branch asymmetry and inter-branch coupling may substantially alter heating. We developed and validated a cumulative transfer function (cTF) framework to address this gap. Methods: Following ISO/TS 10974 Tier-3 formalism, we measured, calibrated, and validated cTFs for a commercial 35 cm bipolar epicardial lead at 1.5 T. The framework explicitly accounts for branch-specific response and cross-branch coupling. Validation was performed with 24 canonical lead configurations in a homogeneous phantom and, without recalibration, in a heterogeneous anthropomorphic pediatric phantom with clinically derived trajectories. A single-branch TF approximation served as a comparator. The validated cTF was applied to predict RF heating across adult and pediatric human models at multiple imaging landmarks. Results: Compared with the single-branch TF approximation, the cTF reduced prediction error by nearly 70% in the primary validation dataset. In secondary validation, the cTF maintained low error across clinically relevant trajectories and imaging landmarks. In human models, the framework revealed marked anatomy- and landmark-dependent variation in predicted heating for the tested 35 cm lead, with low predicted heating in pediatric models and substantially higher heating in selected adult chest and upper abdominal imaging scenarios. Conclusion: The cTF provides a validated framework for RF-heating assessment of bifurcated leads and substantially improves prediction accuracy over single-branch TF approximations that neglect branch coupling.
Open AccessCumulative Transfer Function for Assessment of MRI-Induced RF Heating Risk in Pediatric Patients Implanted with Bifurcated Leads
Purpose: RF-induced heating remains a major barrier to MRI access for patients with epicardial cardiac implantable electronic devices (CIEDs). Although ISO/TS 10974 Tier-3 transfer function (TF) methods are established for unbranched leads, no analogous framework exists for bifurcated leads, in which branch asymmetry and inter-branch coupling may substantially alter heating. We developed and validated a cumulative transfer function (cTF) framework to address this gap. Methods: Following ISO/TS 10974 Tier-3 formalism, we measured, calibrated, and validated cTFs for a commercial 35 cm bipolar epicardial lead at 1.5 T. The framework explicitly accounts for branch-specific response and cross-branch coupling. Validation was performed with 24 canonical lead configurations in a homogeneous phantom and, without recalibration, in a heterogeneous anthropomorphic pediatric phantom with clinically derived trajectories. A single-branch TF approximation served as a comparator. The validated cTF was applied to predict RF heating across adult and pediatric human models at multiple imaging landmarks. Results: Compared with the single-branch TF approximation, the cTF reduced prediction error by nearly 70% in the primary validation dataset. In secondary validation, the cTF maintained low error across clinically relevant trajectories and imaging landmarks. In human models, the framework revealed marked anatomy- and landmark-dependent variation in predicted heating for the tested 35 cm lead, with low predicted heating in pediatric models and substantially higher heating in selected adult chest and upper abdominal imaging scenarios. Conclusion: The cTF provides a validated framework for RF-heating assessment of bifurcated leads and substantially improves prediction accuracy over single-branch TF approximations that neglect branch coupling.
- Open Access
- 24 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 1411-1426
A deep brain stimulation–conditioned RF coil for 3T MRI
Purpose: To develop and test an MRI coil assembly for imaging deep brain stimulation (DBS) at 3 T with a reduced level of local specific absorption rate of RF fields near the implant.Methods: A mechanical rotatable linearly polarized birdcage transmitter outfitted with a 32‐channel receive array was constructed. The coil performance and image quality were systematically evaluated using bench‐level measurements and imaging performance tests, including SNR maps, array element noise correlation, and acceleration capabilities. Electromagnetic simulations and phantom experiments were performed with clinically relevant DBS device configurations to evaluate the reduction of specific absorption rate and temperature near the implant compared with a circular polarized body coil setup.Results: The linearly polarized birdcage coil features a block‐shaped low electric field region to be co‐aligned with the implanted DBS lead trajectory, while the close‐fit receive array enables imaging with high SNR and enhanced encoding capabilities.Conclusion: The 3T coil assembly, consisting of a rotating linear birdcage and a 32‐channel close‐fit receive array, showed DBS‐conditioned imaging technology with substantially reduced heat generation at the DBS implants.
- 24 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 1411-1426
Open AccessA deep brain stimulation–conditioned RF coil for 3T MRI
Purpose: To develop and test an MRI coil assembly for imaging deep brain stimulation (DBS) at 3 T with a reduced level of local specific absorption rate of RF fields near the implant.Methods: A mechanical rotatable linearly polarized birdcage transmitter outfitted with a 32‐channel receive array was constructed. The coil performance and image quality were systematically evaluated using bench‐level measurements and imaging performance tests, including SNR maps, array element noise correlation, and acceleration capabilities. Electromagnetic simulations and phantom experiments were performed with clinically relevant DBS device configurations to evaluate the reduction of specific absorption rate and temperature near the implant compared with a circular polarized body coil setup.Results: The linearly polarized birdcage coil features a block‐shaped low electric field region to be co‐aligned with the implanted DBS lead trajectory, while the close‐fit receive array enables imaging with high SNR and enhanced encoding capabilities.Conclusion: The 3T coil assembly, consisting of a rotating linear birdcage and a 32‐channel close‐fit receive array, showed DBS‐conditioned imaging technology with substantially reduced heat generation at the DBS implants.
- Open Access
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2023, 1-4
Rapid prediction of MRI-induced RF heating of active implantable medical devices using machine learning
The interaction between an active implantable medical device and magnetic resonance imaging (MRI) radiofrequency (RF) fields can cause excessive tissue heating. Existing methods for predicting RF heating in the presence of an implant rely on either extensive phantom experiments or electromagnetic (EM) simulations with varying degrees of approximation of the MR environment, the patient, or the implant. On the contrary, fast MR thermometry techniques can provide a reliable real-time map of temperature rise in the tissue in the vicinity of conductive implants. In this proof-of-concept study, we examined whether a machine learning (ML) based model could predict the temperature increase in the tissue near the tip of an implanted lead after several minutes of RF exposure based on only a few seconds of experimentally measured temperature values. We performed phantom experiments with a commercial deep brain stimulation (DBS) system to train a fully connected feedforward neural network (NN) to predict temperature rise after ~3 minutes of scanning at a 3 T scanner using only data from the first 5 seconds. The NN effectively predicted ΔT max —R 2 = 0.99 for predictions in the test dataset. Our model also showed potential in predicting RF heating for other various scenarios, including a DBS system at a different field strength (1.5 T MRI, R 2 = 0.87), different field polarization (1.2 T vertical MRI, R 2 = 0.79), and an unseen implant (cardiac leads at 1.5 T MRI, R 2 = 0.91). Our results indicate great potential for the application of ML in combination with fast MR thermometry techniques for rapid prediction of RF heating for implants in various MR environments.Clinical Relevance— Machine learning-based algorithms can potentially enable rapid prediction of MRI-induced RF heating in the presence of unknown AIMDs in various MR environments.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2023, 1-4
Open AccessRapid prediction of MRI-induced RF heating of active implantable medical devices using machine learning
The interaction between an active implantable medical device and magnetic resonance imaging (MRI) radiofrequency (RF) fields can cause excessive tissue heating. Existing methods for predicting RF heating in the presence of an implant rely on either extensive phantom experiments or electromagnetic (EM) simulations with varying degrees of approximation of the MR environment, the patient, or the implant. On the contrary, fast MR thermometry techniques can provide a reliable real-time map of temperature rise in the tissue in the vicinity of conductive implants. In this proof-of-concept study, we examined whether a machine learning (ML) based model could predict the temperature increase in the tissue near the tip of an implanted lead after several minutes of RF exposure based on only a few seconds of experimentally measured temperature values. We performed phantom experiments with a commercial deep brain stimulation (DBS) system to train a fully connected feedforward neural network (NN) to predict temperature rise after ~3 minutes of scanning at a 3 T scanner using only data from the first 5 seconds. The NN effectively predicted ΔT max —R 2 = 0.99 for predictions in the test dataset. Our model also showed potential in predicting RF heating for other various scenarios, including a DBS system at a different field strength (1.5 T MRI, R 2 = 0.87), different field polarization (1.2 T vertical MRI, R 2 = 0.79), and an unseen implant (cardiac leads at 1.5 T MRI, R 2 = 0.91). Our results indicate great potential for the application of ML in combination with fast MR thermometry techniques for rapid prediction of RF heating for implants in various MR environments.Clinical Relevance— Machine learning-based algorithms can potentially enable rapid prediction of MRI-induced RF heating in the presence of unknown AIMDs in various MR environments.
- Open Access
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2023, 1-5
Optimizing the trajectory of deep brain stimulation leads reduces RF heating during MRI at 3 T: Characteristics and clinical translation
Radiofrequency (RF) induced tissue heating around deep brain stimulation (DBS) leads is a well-known safety risk during magnetic resonance imaging (MRI), hindering routine protocols for patients. Known factors that contribute to variations in the magnitude of RF heating across patients include the implanted lead’s trajectory and its orientation with respect to the MRI electric fields. Currently, there are no consistent requirements for surgically implanting the extracranial portion of the DBS lead. Recent studies have shown that incorporating concentric loops in the extracranial trajectory of the lead can reduce RF heating, but the optimal positioning of the loop is unknown. In this study, we evaluated RF heating of 77 unique lead trajectories to determine how different characteristics of the trajectory affect RF heating during MRI at 3 T. We performed phantom experiments with commercial DBS systems from two manufacturers to determine how consistently modifying the lead trajectory mitigates RF heating. We also presented the first surgical implementation of these modified trajectories in patients. Low-heating trajectories included small concentric loops near the surgical burr hole which were readily implemented during the surgical procedure; these trajectories generated nearly a 2-fold reduction in RF heating compared to unmodified trajectories.Clinical Relevance— Surgically modifying the DBS lead trajectory can be a cost-effective strategy for reducing RF-induced heating during MRI at 3 T.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2023, 1-5
Open AccessOptimizing the trajectory of deep brain stimulation leads reduces RF heating during MRI at 3 T: Characteristics and clinical translation
Radiofrequency (RF) induced tissue heating around deep brain stimulation (DBS) leads is a well-known safety risk during magnetic resonance imaging (MRI), hindering routine protocols for patients. Known factors that contribute to variations in the magnitude of RF heating across patients include the implanted lead’s trajectory and its orientation with respect to the MRI electric fields. Currently, there are no consistent requirements for surgically implanting the extracranial portion of the DBS lead. Recent studies have shown that incorporating concentric loops in the extracranial trajectory of the lead can reduce RF heating, but the optimal positioning of the loop is unknown. In this study, we evaluated RF heating of 77 unique lead trajectories to determine how different characteristics of the trajectory affect RF heating during MRI at 3 T. We performed phantom experiments with commercial DBS systems from two manufacturers to determine how consistently modifying the lead trajectory mitigates RF heating. We also presented the first surgical implementation of these modified trajectories in patients. Low-heating trajectories included small concentric loops near the surgical burr hole which were readily implemented during the surgical procedure; these trajectories generated nearly a 2-fold reduction in RF heating compared to unmodified trajectories.Clinical Relevance— Surgically modifying the DBS lead trajectory can be a cost-effective strategy for reducing RF-induced heating during MRI at 3 T.
- Open Access
- 16 December 2022
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 101 (1) , 47-59
Artifacts Can Be Deceiving: The Actual Location of Deep Brain Stimulation Electrodes Differs from the Artifact Seen on Magnetic Resonance Images
Introduction: Deep brain stimulation (DBS) is a common treatment for a variety of neurological and psychiatric disorders. Recent studies have highlighted the role of neuroimaging in localizing the position of electrode contacts relative to target brain areas in order to optimize DBS programming. Among different imaging methods, postoperative magnetic resonance imaging (MRI) has been widely used for DBS electrode localization; however, the geometrical distortion induced by the lead limits its accuracy. In this work, we investigated to what degree the difference between the actual location of the lead’s tip and the location of the tip estimated from the MRI artifact varies depending on the MRI sequence parameters such as acquisition plane and phase encoding direction, as well as the lead’s extracranial configuration. Accordingly, an imaging technique to increase the accuracy of lead localization was devised and discussed. Methods: We designed and constructed an anthropomorphic phantom with an implanted DBS system following 18 clinically relevant configurations. The phantom was scanned at a Siemens 1.5 Tesla Aera scanner using a T1MPRAGE sequence optimized for clinical use and a T1TSE sequence optimized for research purposes. We varied slice acquisition plane and phase encoding direction and calculated the distance between the caudal tip of the DBS lead MRI artifact and the actual tip of the lead, as estimated from MRI reference markers. Results: Imaging parameters and lead configuration substantially altered the difference in the depth of the lead within its MRI artifact on the scale of several millimeters − with a difference as large as 4.99 mm. The actual tip of the DBS lead was found to be consistently more rostral than the tip estimated from the MR image artifact. The smallest difference between the tip of the DBS lead and the tip of the MRI artifact using the clinically relevant sequence (i.e., T1MPRAGE) was found with the sagittal acquisition plane and anterior-posterior phase encoding direction. Discussion/Conclusion: The actual tip of an implanted DBS lead is located up to several millimeters rostral to the tip of the lead’s artifact on postoperative MR images. This distance depends on the MRI sequence parameters and the DBS system’s extracranial trajectory. MRI parameters may be altered to improve this localization.
- 16 December 2022
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 101 (1) , 47-59
Open AccessArtifacts Can Be Deceiving: The Actual Location of Deep Brain Stimulation Electrodes Differs from the Artifact Seen on Magnetic Resonance Images
Introduction: Deep brain stimulation (DBS) is a common treatment for a variety of neurological and psychiatric disorders. Recent studies have highlighted the role of neuroimaging in localizing the position of electrode contacts relative to target brain areas in order to optimize DBS programming. Among different imaging methods, postoperative magnetic resonance imaging (MRI) has been widely used for DBS electrode localization; however, the geometrical distortion induced by the lead limits its accuracy. In this work, we investigated to what degree the difference between the actual location of the lead’s tip and the location of the tip estimated from the MRI artifact varies depending on the MRI sequence parameters such as acquisition plane and phase encoding direction, as well as the lead’s extracranial configuration. Accordingly, an imaging technique to increase the accuracy of lead localization was devised and discussed. Methods: We designed and constructed an anthropomorphic phantom with an implanted DBS system following 18 clinically relevant configurations. The phantom was scanned at a Siemens 1.5 Tesla Aera scanner using a T1MPRAGE sequence optimized for clinical use and a T1TSE sequence optimized for research purposes. We varied slice acquisition plane and phase encoding direction and calculated the distance between the caudal tip of the DBS lead MRI artifact and the actual tip of the lead, as estimated from MRI reference markers. Results: Imaging parameters and lead configuration substantially altered the difference in the depth of the lead within its MRI artifact on the scale of several millimeters − with a difference as large as 4.99 mm. The actual tip of the DBS lead was found to be consistently more rostral than the tip estimated from the MR image artifact. The smallest difference between the tip of the DBS lead and the tip of the MRI artifact using the clinically relevant sequence (i.e., T1MPRAGE) was found with the sagittal acquisition plane and anterior-posterior phase encoding direction. Discussion/Conclusion: The actual tip of an implanted DBS lead is located up to several millimeters rostral to the tip of the lead’s artifact on postoperative MR images. This distance depends on the MRI sequence parameters and the DBS system’s extracranial trajectory. MRI parameters may be altered to improve this localization.
- 30 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (5) , 1757-1766
Machine Learning-Based Prediction of MRI-Induced Power Absorption in the Tissue in Patients With Simplified Deep Brain Stimulation Lead Models
Interaction of an active electronic implant such as a deep brain stimulation (DBS) system and magnetic resonance imaging (MRI) radiofrequency (RF) fields can induce excessive tissue heating, limiting MRI accessibility. Efforts to quantify RF heating mostly rely on electromagnetic (EM) simulations to assess individualized specific absorption rate (SAR), but such simulations require extensive computational resources. Here, we investigate if a predictive model using machine learning (ML) can predict the local SAR in the tissue around tips of implanted leads from the distribution of the tangential component of the MRI incident electric field, E tan . A dataset of 260 unique patient-derived and artificial DBS lead trajectories was constructed, and the 1 g-averaged SAR, 1 g SAR max , at the lead-tip during 1.5 T MRI was determined by EM simulations. E tan values along each lead's trajectory and the simulated SAR values were used to train and test the ML algorithm. The resulting predictions of the ML algorithm indicated that the distribution of E tan could effectively predict 1 g SAR max at the DBS lead-tip ( R = 0.82). Our results indicate that ML has the potential to provide a fast method for predicting MR-induced power absorption in the tissue around tips of implanted leads such as those in active electronic medical devices.
- 30 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (5) , 1757-1766
Machine Learning-Based Prediction of MRI-Induced Power Absorption in the Tissue in Patients With Simplified Deep Brain Stimulation Lead Models
Interaction of an active electronic implant such as a deep brain stimulation (DBS) system and magnetic resonance imaging (MRI) radiofrequency (RF) fields can induce excessive tissue heating, limiting MRI accessibility. Efforts to quantify RF heating mostly rely on electromagnetic (EM) simulations to assess individualized specific absorption rate (SAR), but such simulations require extensive computational resources. Here, we investigate if a predictive model using machine learning (ML) can predict the local SAR in the tissue around tips of implanted leads from the distribution of the tangential component of the MRI incident electric field, E tan . A dataset of 260 unique patient-derived and artificial DBS lead trajectories was constructed, and the 1 g-averaged SAR, 1 g SAR max , at the lead-tip during 1.5 T MRI was determined by EM simulations. E tan values along each lead's trajectory and the simulated SAR values were used to train and test the ML algorithm. The resulting predictions of the ML algorithm indicated that the distribution of E tan could effectively predict 1 g SAR max at the DBS lead-tip ( R = 0.82). Our results indicate that ML has the potential to provide a fast method for predicting MR-induced power absorption in the tissue around tips of implanted leads such as those in active electronic medical devices.
- 7 May 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (3) , 1560-1572
Vertical open‐bore MRI scanners generate significantly less radiofrequency heating around implanted leads: A study of deep brain stimulation implants in 1.2T OASIS scanners versus 1.5T horizontal systems
Purpose: Patients with active implants such as deep brain stimulation (DBS) devices are often denied access to MRI due to safety concerns associated with the radiofrequency (RF) heating of their electrodes. The majority of studies on RF heating of conductive implants have been performed in horizontal close‐bore MRI scanners. Vertical MRI scanners which have a 90° rotated transmit coil generate fundamentally different electric and magnetic field distributions, yet very little is known about RF heating of implants in this class of scanners. We performed numerical simulations as well as phantom experiments to compare RF heating of DBS implants in a 1.2T vertical scanner (OASIS, Hitachi) compared to a 1.5T horizontal scanner (Aera, Siemens).Methods: Simulations were performed on 90 lead models created from post‐operative CT images of patients with DBS implants. Experiments were performed with wires and commercial DBS devices implanted in an anthropomorphic phantom.Results: We found significant reduction of 0.1 g‐averaged specific absorption rate (30‐fold, P < 1 × 10−5) and RF heating (9‐fold, P < .026) in the 1.2T vertical scanner compared to the 1.5T conventional scanner.Conclusion: Vertical MRI scanners appear to generate lower RF heating around DBS leads, providing potentially heightened safety or the flexibility to use sequences with higher power levels than on conventional systems.
- 7 May 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (3) , 1560-1572
Vertical open‐bore MRI scanners generate significantly less radiofrequency heating around implanted leads: A study of deep brain stimulation implants in 1.2T OASIS scanners versus 1.5T horizontal systems
Purpose: Patients with active implants such as deep brain stimulation (DBS) devices are often denied access to MRI due to safety concerns associated with the radiofrequency (RF) heating of their electrodes. The majority of studies on RF heating of conductive implants have been performed in horizontal close‐bore MRI scanners. Vertical MRI scanners which have a 90° rotated transmit coil generate fundamentally different electric and magnetic field distributions, yet very little is known about RF heating of implants in this class of scanners. We performed numerical simulations as well as phantom experiments to compare RF heating of DBS implants in a 1.2T vertical scanner (OASIS, Hitachi) compared to a 1.5T horizontal scanner (Aera, Siemens).Methods: Simulations were performed on 90 lead models created from post‐operative CT images of patients with DBS implants. Experiments were performed with wires and commercial DBS devices implanted in an anthropomorphic phantom.Results: We found significant reduction of 0.1 g‐averaged specific absorption rate (30‐fold, P < 1 × 10−5) and RF heating (9‐fold, P < .026) in the 1.2T vertical scanner compared to the 1.5T conventional scanner.Conclusion: Vertical MRI scanners appear to generate lower RF heating around DBS leads, providing potentially heightened safety or the flexibility to use sequences with higher power levels than on conventional systems.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2020, 6107-6110
Evaluating Accuracy of Numerical Simulations in Predicting Heating of Wire Implants During MRI at 1.5 T
Patients with long conductive implants such as deep brain stimulation (DBS) leads are often denied access to magnetic resonance imaging (MRI) exams due to safety concerns associated with radiofrequency (RF) heating of implants. Experimental temperature measurements in tissue-mimicking gel phantoms under MRI RF exposure conditions are common practices to predict in-vivo heating in the tissue surrounding wire implants. Such experiments are both expensive—as they require access to MRI units—and time-consuming due to complex implant setups. Recently, full-wave numerical simulations, which include realistic MRI RF coil models and human phantoms, are suggested as an alternative to experiments. There is however, little literature available on the accuracy of such numerical models against direct thermal measurements. This study aimed to evaluate the agreement between simulations and measurements of temperature rise at the tips of wire implants exposed to RF exposure at 64 MHz (1.5 T) for different implant trajectories typically encountered in patients with DBS leads. Heating was assessed in seven patient-derived lead configurations using both simulations and RF heating measurements during imaging of an anthropomorphic head phantom with implanted wires. We found substantial variation in RF heating as a function of lead trajectory; there was a 9.5-fold and 9-fold increase in temperature rise from ID1 to ID7 during simulations and experimental measurements, respectively. There was a strong correlation (r 2 = 0.74) between simulated and measured temperatures for different lead trajectories. The maximum difference between simulated and measured temperature was 0.26 °C with simulations overestimating the temperature rise.
- 1 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2020, 6107-6110
Evaluating Accuracy of Numerical Simulations in Predicting Heating of Wire Implants During MRI at 1.5 T
Patients with long conductive implants such as deep brain stimulation (DBS) leads are often denied access to magnetic resonance imaging (MRI) exams due to safety concerns associated with radiofrequency (RF) heating of implants. Experimental temperature measurements in tissue-mimicking gel phantoms under MRI RF exposure conditions are common practices to predict in-vivo heating in the tissue surrounding wire implants. Such experiments are both expensive—as they require access to MRI units—and time-consuming due to complex implant setups. Recently, full-wave numerical simulations, which include realistic MRI RF coil models and human phantoms, are suggested as an alternative to experiments. There is however, little literature available on the accuracy of such numerical models against direct thermal measurements. This study aimed to evaluate the agreement between simulations and measurements of temperature rise at the tips of wire implants exposed to RF exposure at 64 MHz (1.5 T) for different implant trajectories typically encountered in patients with DBS leads. Heating was assessed in seven patient-derived lead configurations using both simulations and RF heating measurements during imaging of an anthropomorphic head phantom with implanted wires. We found substantial variation in RF heating as a function of lead trajectory; there was a 9.5-fold and 9-fold increase in temperature rise from ID1 to ID7 during simulations and experimental measurements, respectively. There was a strong correlation (r 2 = 0.74) between simulated and measured temperatures for different lead trajectories. The maximum difference between simulated and measured temperature was 0.26 °C with simulations overestimating the temperature rise.