AIAlmazbek Imanaliev

Almazbek Imanaliev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Almazbek Imanaliev has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Towards testing Bell's inequality using atoms correlated in momentum

    by Almazbek Imanaliev

    Vers la réalisation du test d’inégalité de Bell avec les atomes corrèle en impulsion: Ce manuscrit décrit des expériences d’optique atomique quantique utilisant un détecteur résolu en impulsions d’atomes uniques d’hélium métastable. La première partie du manuscrit décrit la mesure de cohérence de deuxième ordre de la superradiance à partir d’un condensat de Bose-Einstein d’helium métastable. Bien que le condensat soit cohérent et le gain du processus de superradiance élevé, celle-ci montre toujours une statistique thermique comme celle de l’émission spontanée. La suite du manuscrit est dédiée au test de la non localité d’une source atomique corrélée en impulsion. Le schéma du test s’inspire d’une réalisation faite par Rarity et Tapster sur des photons intriqués en impulsion. Les ingrédients principaux d’un tel schéma sont la source atomique générée par instabilité dynamique du condensat dans un réseau optique en mouvement, le contrôle cohérent des atomes par diffraction de Bragg et la mesure de la corrélation des atomes dans les différentes voies de sortie du schéma interférométrique. Un point clé est le contrôle et la manipulation de la phase des ondes atomiques. Le chapitre 3 décrit les tests sur le contrôle cohérent par diffraction de Bragg et leurs résultats encourageants. La nature non classique de notre source atomique est démontrée par l’observation d’une interférence à deux particules en les envoyant sur une séparatrice atomique. Cet analogue atomique de l’expérience de Hong Ou et Mandel est le sujet du dernier chapitre de ce manuscrit. Le résultat de cette expérience ouvre la possibilité du test d’inégalité de Bell avec des particules massives corrélées sur des degrés de liberté externe.

  • Finite Element Analysis of the Uncertainty Contribution From Mechanical Imperfections in the LNE’s Thompson–Lampard Calculable Capacitor

    by Almazbek Imanaliev, Olivier Thevenot, Kamel Dougdag

    Thompson-Lampard type calculable capacitors (TLCC) serve as electrical capacitance standards, enabling the realization of the farad in the International System of Units (SI) with a combined uncertainty on the order of one part in 108. This paper presents an electrostatic finite element (FEM) simulation study focusing on the mechanical imperfections inherent in the developed second generation TLCC at LNE and their influence on the combined uncertainty of the practical realization of the farad. In particular, this study establishes the acceptable tolerances for deviations from perfect geometrical arrangements of the TLCC electrodes required to achieve the target relative uncertainty of one part in 108. The simulation predictions are compared with corresponding experimental observations which were conducted with the help of the sub-micron level control of the standard’s electrode geometry. In the second generation of the LNE’s TLCC, the uncertainty contribution from mechanical imperfections was reduced by at least a factor of 4, as demonstrated by the present FEM analysis. Combined with other improvements, the standard’s overall uncertainty meets the target level.


  • Measuring Nonlinearity in AH 2700A Capacitance Bridges With Sub-ppm Level Uncertainty

    by Almazbek Imanaliev, Olivier Thévenot, Kamel Dougdag, François Piquemal

    The stability and non-linearity of a commercial AH 2700A capacitance bridge were studied beyond its specified capabilities using the Thompson-Lampard Calculable Capacitor (TLCC) at LNE. The TLCC allows for continuous variation of measured capacitance between 0.4 pF and 1.2 pF with a resolution of 2 parts in 10 7 and stability better than 1 part in 10 9 over 2 days. The study aimed to determine root cause of the saw-tooth non-linearity pattern observed in the AH 2700A capacitance bridge. This pattern becomes apparent when the internal calibration is no longer valid, indicating deviations in the bridge circuit. Additionally, the dependence of capacitance non-linearity on various factors such as frequency and capacitance value are described. This work enables automatic calibration of the commercial bridge with an uncertainty of sub-ppm level and allows for quick evaluation of TLCC’s non-linearity and monitoring of any changes over time through in-situ measurements.


  • Progress Report on the Thompson–Lampard Calculable Capacitor at LNE

    by Olivier Thevenot, Almazbek Imanaliev, Kamel Dougdag, François Piquemal

    We report on a new calculable electrical capacitance standard, which will enable realizing the farad in the SI with a combined uncertainty (k=1) of the order of one part in 10 8 . To achieve this result, we developed various original mechanical systems to position and control macroscopic elements at the nanometer scale. A measurement system allowing the in-situ control of this positioning was integrated into the standard. The electrodes were held in position in a hexapod structure, which was mechanically isolated from the standard’s carrier structure to ensure that no force is applied to change the electrodes’ positions. An additional electrode, so-called “movable guard”, was introduced into the cavity formed by the electrodes to vary the cross capacitance of the standard. The lateral position of this guard in the cavity must be controlled to within 100 nm along its entire length of travel, which was achieved by means of two piezoelectric actuators. An additional capacitive measurement device between the moving guard and the five electrodes ensures that it is correctly positioned in the cavity. We demonstrated that the system described here guarantees the correct positioning of the guard within 80 nm in the cavity, regardless of its vertical position.


  • Calibration of a superconducting gravimeter with an absolute atom gravimeter

    by Sébastien Merlet, Pierre Gillot, Bing Cheng, Romain Karcher, Almazbek Imanaliev, Ludger Timmen, Franck Pereira dos Santos


  • Improving the Accuracy of Atom Gravimeters with Ultracold Sources

    by Romain Karcher, Almazbek Imanaliev, Sebastien Merlet, Franck Pereira dos Santos

    Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget.

  • Open Access

    Improving the accuracy of atom interferometers with ultracold sources

    by Romain Karcher, Almazbek Imanaliev, Sebastien Merlet, Franck Pereira Dos Santos

    We report on the implementation of ultracold atoms as a source in a state of the art atom gravimeter. We perform gravity measurements with 10nm s-2 statistical uncertainties in a so-far largely unexplored temperature range for such a high accuracy sensor, down to 50 nK. This allows for an improved characterization of the most limiting systematic effect, related to wavefront aberrations of light beamsplitters. A thorough model of the impact of this effect onto the measurement is developed and a method is proposed to correct for this bias based on the extrapolation of the measurements down to zero temperature. Finally, an uncertainty of 13 nm s-2 is obtained in the evaluation of this systematic effect, which can be improved further by performing measurements at even lower temperatures. Our results clearly demonstrate the benefit brought by ultracold atoms to the metrological study of free falling atom interferometers. By tackling their main limitation, the method presented here allows reaching record-breaking accuracies for inertial sensors based on atom interferometry.


  • Ultracold Atom Gravimeter

    by Sebastien Merlet, Romain Karcher, Almazbek Imanaliev, Franck Pereira Dos Santos

    Atom interferometry allows for the realisation of inertial sensors based on laser cooled atoms. Their limits in performances, both in terms of accuracy and stability, are linked to the temperature of the atomic cloud, in the low μK range, and more specifically, to the residual ballistic expansion of the atomic sources in the laser beams. To overcome these limits, we use as a source ultracold atoms in the nano-kelvin range in our absolute atom gravimeter.


  • Two-Particle Four-Mode Interferometer for Atoms

    by Pierre Dussarrat, Maxime Perrier, Almazbek Imanaliev, Raphael Lopes, Alain Aspect, Marc Cheneau, Denis Boiron, Christoph I. Westbrook

    We present a free-space interferometer to observe two-particle interference of a pair of atoms with entangled momenta. The source of atom pairs is a Bose-Einstein condensate subject to a dynamical instability, and the interferometer is realized using Bragg diffraction on optical lattices, in the spirit of our recent Hong-Ou-Mandel experiment. We report on an observation ruling out the possibility of a purely mixed state at the input of the interferometer. We explain how our current setup can be extended to enable a test of a Bell inequality on momentum observables.


  • Top Cited Papers

    A determination of the Planck constant using the LNE Kibble balance in air

    by M Thomas, D Ziane, P Pinot, R Karcher, A Imanaliev, F Pereira Dos Santos, S Merlet, F Piquemal, P Espel

    A determination of the Planck constant h using the LNE Kibble balance in air was carried out in the spring of 2017. Substantial improvements since 2014, chiefly related to the mass standard, mechanical alignments, voltage measurements and type A evaluation uncertainties, leads to a h value of 6.626 070 41(38) × 10 –34 J · s, with a relative standard uncertainty of 5.7 × 10 –8 .