Sergey Gunther
Research Subjects
Sergey Gunther has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Ekaterina Sergeevna Marchenko
National Research Tomsk State University, Tomsk, Russia
6 shared publications - Yuri F. Yasenchuk
Laboratory of Superelastic Biointerfaces, National Research Tomsk State University, 36 Lenin Ave., 634045 Tomsk, Russia
6 shared publications - Gulsharat A. Baigonakova
Laboratory of Medical Alloys and Implants with Shape Memory, National Research Tomsk State University, Tomsk, Russia
4 shared publications - Oleg V. Kokorev
Siberian State Medical University
4 shared publications - Georgiy Ts. Dambaev
Siberian State Medical University
3 shared publications G.TS. Dambaev
Department of Clinical Surgery Siberian State Medical University Tomsk Russia
2 shared publications
Latest Publications
- 9 January 2023
- Published by Taylor & Francis in Materials and Manufacturing Processes
- Vol. 38 (6) , 659-667
Plasticity of Porous NiTi Alloys Obtained by Self-propagating High-temperature Synthesis in Closed and Open Gas Flow Reactors
Porous NiTi alloys were obtained by self-propagating high-temperature synthesis (SHS) using layer-by-layer combustion in closed and open gas flow reactors under a protective argon atmosphere. The maximum compressive strain of porous NiTi alloys synthesized in the closed reactor was 34% compared to 7% in the open gas flow reactor. X-ray diffraction, differential scanning calorimetry, scanning electron microscopy, energy dispersive spectroscopy, and optical microscopy showed that the reaction products in the two-phase gas zone of peritectic crystallization are in the form of isolated Ti2Ni crystalline clusters in the TiNi matrix. The ductility and strength of the recrystallized Ti2Ni phase hard dendrites increase the effective stiffness of porous NiTi alloys and decrease the maximum compressive strain. A highly porous NiTi alloy with improved mechanical properties was obtained by the SHS method in a closed reactor.
- 9 January 2023
- Published by Taylor & Francis in Materials and Manufacturing Processes
- Vol. 38 (6) , 659-667
Plasticity of Porous NiTi Alloys Obtained by Self-propagating High-temperature Synthesis in Closed and Open Gas Flow Reactors
Porous NiTi alloys were obtained by self-propagating high-temperature synthesis (SHS) using layer-by-layer combustion in closed and open gas flow reactors under a protective argon atmosphere. The maximum compressive strain of porous NiTi alloys synthesized in the closed reactor was 34% compared to 7% in the open gas flow reactor. X-ray diffraction, differential scanning calorimetry, scanning electron microscopy, energy dispersive spectroscopy, and optical microscopy showed that the reaction products in the two-phase gas zone of peritectic crystallization are in the form of isolated Ti2Ni crystalline clusters in the TiNi matrix. The ductility and strength of the recrystallized Ti2Ni phase hard dendrites increase the effective stiffness of porous NiTi alloys and decrease the maximum compressive strain. A highly porous NiTi alloy with improved mechanical properties was obtained by the SHS method in a closed reactor.
- Open Access
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 68-81
Clinical application of titanium nickelide knitwear based on the quantitative assessment of rheological similarity to soft biological tissues
Samples of metal knitted mesh made of the 40 μm, 60 μm and 90 μm diameter TiNi wires are studied by uniaxial tension to rupture and uniaxial cyclic tension. It was found that the metal knitted TiNi mesh behaves like a hyperelastic material under uniaxial tension in contrast to the superelastic wire from which it is made. Using the rheological models of Gent, Neo-Hookean, Mooney–Rivlin and Bergstrom-Boyce, the calculation of the cyclic tension of the knitted mesh was carried out. The similarity of the mechanical behavior of knitted mesh and biological tissues is shown. Criteria for quantitative assessment of the biomechanical compatibility of a knitted mesh implant for plasty of hyperelastic biological tissues are proposed.The main criteria for the rheological similarity of knitted mesh and soft tissues are the ultimate tensile strength, elastic modulus and the range of low-modulus and high-modulus elastic strain under loading and unloading; the residual strain value during cyclic tension.It has been found that knitted mesh made of superelastic TiNi wire exhibits a rubber-like behavior characteristic of hyperelastic materials under soft zero cyclic tension. At the same time, in the most loaded contact areas of the superelastic TiNi wire, the martensitic transition did not affect the tension cycles is due to friction, which counteracts the recovery of elastic strain during unloading. It has been established that the Bergstrom–Boyce model is closest in terms of the stress–strain diagram to the knitted mesh and biological tissues. Knitted mesh implants made of nickeide titanium wire were used for plasty of soft tissues and musculoskeletal complexes. The developed method for quantitative assessment diagram of the hyperelastic knittes mesh. The residual strain during the first two tension of the biocompatibility of the implant and biological tissue make it possible to choosу knitteв mesh with a certain wire diametre, focusing on the forces developed by the knitted mesh and the variable elasticity modulus. The knitted mesh was applied without additional fixation, using elastic self-fixation of knitted mesh loops into soft tissues.
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 68-81
Open AccessClinical application of titanium nickelide knitwear based on the quantitative assessment of rheological similarity to soft biological tissues
Samples of metal knitted mesh made of the 40 μm, 60 μm and 90 μm diameter TiNi wires are studied by uniaxial tension to rupture and uniaxial cyclic tension. It was found that the metal knitted TiNi mesh behaves like a hyperelastic material under uniaxial tension in contrast to the superelastic wire from which it is made. Using the rheological models of Gent, Neo-Hookean, Mooney–Rivlin and Bergstrom-Boyce, the calculation of the cyclic tension of the knitted mesh was carried out. The similarity of the mechanical behavior of knitted mesh and biological tissues is shown. Criteria for quantitative assessment of the biomechanical compatibility of a knitted mesh implant for plasty of hyperelastic biological tissues are proposed.The main criteria for the rheological similarity of knitted mesh and soft tissues are the ultimate tensile strength, elastic modulus and the range of low-modulus and high-modulus elastic strain under loading and unloading; the residual strain value during cyclic tension.It has been found that knitted mesh made of superelastic TiNi wire exhibits a rubber-like behavior characteristic of hyperelastic materials under soft zero cyclic tension. At the same time, in the most loaded contact areas of the superelastic TiNi wire, the martensitic transition did not affect the tension cycles is due to friction, which counteracts the recovery of elastic strain during unloading. It has been established that the Bergstrom–Boyce model is closest in terms of the stress–strain diagram to the knitted mesh and biological tissues. Knitted mesh implants made of nickeide titanium wire were used for plasty of soft tissues and musculoskeletal complexes. The developed method for quantitative assessment diagram of the hyperelastic knittes mesh. The residual strain during the first two tension of the biocompatibility of the implant and biological tissue make it possible to choosу knitteв mesh with a certain wire diametre, focusing on the forces developed by the knitted mesh and the variable elasticity modulus. The knitted mesh was applied without additional fixation, using elastic self-fixation of knitted mesh loops into soft tissues.
- Open Access
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 25-37
Regenerative effect tissue engineering scaffold based on fibrous permeable TiNi-based alloy
The aim of this study was to explore the in vivo applicability of intracorporeal constructions with hepatocytes cultured in the fiber TiNi-based scaffold (FTNS). We also sought to determine whether application of hepatocytes cultured in the FTNS was superior to simple hepatocyte injection in terms of restoration of liver functions and survival time in a CCl4-induced hepatitis rat model. In investigation 200 animals were assigned to explore the experimental groups as follows: Group I – control; Group II – animals with CCl4-induced hepatitis; Group III – animals with toxic hepatitis followed by implantation of cell-free FTNS (sham-surgery); Group IV – animals with toxic hepatitis followed by infusion of hepatocytes only (20 × 106 cells/ml); Group V – animals with toxic hepatitis followed by implantation of hepatocytes cultured in the FTNS. In terms of restoration of liver function, Group V showed a significant reduction of serum alanine aminotransferase level compared to Group II. Group IV also showed a significant decrease in ALT level at 15 days. However, the level of ALT increased at 30 days, and the level was similar with results of the Group II. This probably was caused by a short-term effect of hepatocyte injection only. The change patterns of serum protein, lactate, albumin, fibrinogen, and total bilirubin levels were similar to the results of ALT. The survival time of animals was significantly longer in Group V. These findings showed possible abilities of the FTNS as a scaffold to support the hepatocellular metabolism. Using 12 animals, image analysis of SEM data of in vivo hepatocyte evolution in the FTNS was carried out. In the SEM analysis, hepatocytes demonstrated good adhesion and proliferation in the pore space of the FTNS. Moreover, mature tissue comprising both colloidal and fibrous components filled the pore body by 95% in 28 days. Overall, this study sheds a light on how the implantable «auxiliary liver» by engrafting the cultured FTNS substitutes the missing hepatic function without the need to replace the whole liver.
- 25 June 2022
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 25 (2) , 25-37
Open AccessRegenerative effect tissue engineering scaffold based on fibrous permeable TiNi-based alloy
The aim of this study was to explore the in vivo applicability of intracorporeal constructions with hepatocytes cultured in the fiber TiNi-based scaffold (FTNS). We also sought to determine whether application of hepatocytes cultured in the FTNS was superior to simple hepatocyte injection in terms of restoration of liver functions and survival time in a CCl4-induced hepatitis rat model. In investigation 200 animals were assigned to explore the experimental groups as follows: Group I – control; Group II – animals with CCl4-induced hepatitis; Group III – animals with toxic hepatitis followed by implantation of cell-free FTNS (sham-surgery); Group IV – animals with toxic hepatitis followed by infusion of hepatocytes only (20 × 106 cells/ml); Group V – animals with toxic hepatitis followed by implantation of hepatocytes cultured in the FTNS. In terms of restoration of liver function, Group V showed a significant reduction of serum alanine aminotransferase level compared to Group II. Group IV also showed a significant decrease in ALT level at 15 days. However, the level of ALT increased at 30 days, and the level was similar with results of the Group II. This probably was caused by a short-term effect of hepatocyte injection only. The change patterns of serum protein, lactate, albumin, fibrinogen, and total bilirubin levels were similar to the results of ALT. The survival time of animals was significantly longer in Group V. These findings showed possible abilities of the FTNS as a scaffold to support the hepatocellular metabolism. Using 12 animals, image analysis of SEM data of in vivo hepatocyte evolution in the FTNS was carried out. In the SEM analysis, hepatocytes demonstrated good adhesion and proliferation in the pore space of the FTNS. Moreover, mature tissue comprising both colloidal and fibrous components filled the pore body by 95% in 28 days. Overall, this study sheds a light on how the implantable «auxiliary liver» by engrafting the cultured FTNS substitutes the missing hepatic function without the need to replace the whole liver.
- 1 December 2021
- Published by Bentham Science Publishers Ltd. in Micro and Nanosystems
- Vol. 13 (4) , 442-447
Deformation Behavior, Fatigue and Fracture Surface Microstructure of Porous Titanium Nickelide
Background: The porous SHS–TiNi alloy is a widely used material for repairing defects in bone tissues. Objective: The objective of the study is to comprehensively investigate porous SHS–TiNi alloy samples for fatigue strength under cyclic bending, to study deformation characteristics under quasistatic tension and bending, and to carry out the fractographic analysis of fracture features. Methods: The study employed the electrospark method for cutting plates from a porous isotropic SHS– TiNi rod 30 mm in diameter and 300 mm in length. Results: Deformation behaviour under tension and three-point bending of porous plates showed that porous samples undergo viscoelastic deformation due to the austenite–martensite (A→M) phase transformation. The fracture surfaces of elastic porous samples were studied by SEM. Microscopic studies of fracture surfaces revealed zones of quasi-brittle fracture of martensite and viscous fracture of austenite. The porous framework of intermetallic alloy exhibits a continuous brittle layer and numerous brittle non-metallic inclusions. However, successful fatigue tests showed that brittle phases and inclusions do not significantly affect deformation and fatigue characteristics of porous titanium nickelide. It was found that 70% of porous samples sustain 106 cycles of deformation without fracture due to reversible A→M→A phase transformations in the TiNi phase, which is one of the components of multiphase porous alloy. Conclusion: Viscoelastic behavior of the porous sample and its high fatigue strength under cyclic loading is due to reversible deformation of the TiNi phase. The corrosion-resistant layer of the porous framework allows an effective use of SHS–TiNi.
- 1 December 2021
- Published by Bentham Science Publishers Ltd. in Micro and Nanosystems
- Vol. 13 (4) , 442-447
Deformation Behavior, Fatigue and Fracture Surface Microstructure of Porous Titanium Nickelide
Background: The porous SHS–TiNi alloy is a widely used material for repairing defects in bone tissues. Objective: The objective of the study is to comprehensively investigate porous SHS–TiNi alloy samples for fatigue strength under cyclic bending, to study deformation characteristics under quasistatic tension and bending, and to carry out the fractographic analysis of fracture features. Methods: The study employed the electrospark method for cutting plates from a porous isotropic SHS– TiNi rod 30 mm in diameter and 300 mm in length. Results: Deformation behaviour under tension and three-point bending of porous plates showed that porous samples undergo viscoelastic deformation due to the austenite–martensite (A→M) phase transformation. The fracture surfaces of elastic porous samples were studied by SEM. Microscopic studies of fracture surfaces revealed zones of quasi-brittle fracture of martensite and viscous fracture of austenite. The porous framework of intermetallic alloy exhibits a continuous brittle layer and numerous brittle non-metallic inclusions. However, successful fatigue tests showed that brittle phases and inclusions do not significantly affect deformation and fatigue characteristics of porous titanium nickelide. It was found that 70% of porous samples sustain 106 cycles of deformation without fracture due to reversible A→M→A phase transformations in the TiNi phase, which is one of the components of multiphase porous alloy. Conclusion: Viscoelastic behavior of the porous sample and its high fatigue strength under cyclic loading is due to reversible deformation of the TiNi phase. The corrosion-resistant layer of the porous framework allows an effective use of SHS–TiNi.
- 15 February 2020
- Published by Springer Nature in Russian Physics Journal
- Vol. 62 (10) , 1789-1793
Condensed-State Physics Structure and Phase Composition of a Coating Synthesized from Ti–Ni–Ti Laminate on Tini Substrate
- 15 February 2020
- Published by Springer Nature in Russian Physics Journal
- Vol. 62 (10) , 1789-1793
Condensed-State Physics Structure and Phase Composition of a Coating Synthesized from Ti–Ni–Ti Laminate on Tini Substrate
- Open Access
Biocompatibility and Clinical Application of Porous TiNi Alloys Made by Self-Propagating High-Temperature Synthesis (SHS)
Porous TiNi alloys fabricated by self-propagating high-temperature synthesis (SHS) are biomaterials designed for medical application in substituting tissue lesions and they were clinically deployed more than 30 years ago. The SHS process, as a very fast and economically justified route of powder metallurgy, has distinctive features which impart special attributes to the resultant implant, facilitating its integration in terms of bio-mechanical/chemical compatibility. On the phenomenological level, the fact of high biocompatibility of porous SHS TiNi (PTN) material in vivo has been recognized and is not in dispute presently, but the rationale is somewhat disputable. The features of the SHS TiNi process led to a multifarious intermetallic Ti4Ni2(O,N,C)-based constituents in the amorphous-nanocrystalline superficial layer which entirely conceals the matrix and enhances the corrosion resistance of the unwrought alloy. In the current article, we briefly explore issues of the high biocompatibility level on which additional studies could be carried out, as well as recent progress and key fields of clinical application, yet allowing innovative solutions.
Open AccessBiocompatibility and Clinical Application of Porous TiNi Alloys Made by Self-Propagating High-Temperature Synthesis (SHS)
Porous TiNi alloys fabricated by self-propagating high-temperature synthesis (SHS) are biomaterials designed for medical application in substituting tissue lesions and they were clinically deployed more than 30 years ago. The SHS process, as a very fast and economically justified route of powder metallurgy, has distinctive features which impart special attributes to the resultant implant, facilitating its integration in terms of bio-mechanical/chemical compatibility. On the phenomenological level, the fact of high biocompatibility of porous SHS TiNi (PTN) material in vivo has been recognized and is not in dispute presently, but the rationale is somewhat disputable. The features of the SHS TiNi process led to a multifarious intermetallic Ti4Ni2(O,N,C)-based constituents in the amorphous-nanocrystalline superficial layer which entirely conceals the matrix and enhances the corrosion resistance of the unwrought alloy. In the current article, we briefly explore issues of the high biocompatibility level on which additional studies could be carried out, as well as recent progress and key fields of clinical application, yet allowing innovative solutions.
- 3 June 2019
- Published by Springer Nature in Russian Physics Journal
- Vol. 62 (2) , 333-338
The Influence of Surface Treatment on Wettability of TiNi-Based Alloy
- 3 June 2019
- Published by Springer Nature in Russian Physics Journal
- Vol. 62 (2) , 333-338
The Influence of Surface Treatment on Wettability of TiNi-Based Alloy
- Open Access
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 88-97
The Technology of The Manufacturing Thin Wire of TiNi-based Alloys by Using Infrared Radiation
The paper describes the technology of manufacturing a thin nickel-titanium wire through direct exposure to infrared radiation (IR). The effect of IR on the change in the structure of a thin wire made from the TiNi-based alloy was studied during its manufacturing. A comparative analysis of the Ti, Ni and O concentration in the TiNi wire was carried out. The analysis was performed for both a thin wire exposed to infrared radiation and that not exposed to infrared radiation. The wire samples were studied using a scanning electron microscope with the energy dispersive analysis. The infrared radiation effect on the structure of the wire is shown after thermal treatment in the local area of the material.
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 88-97
Open AccessThe Technology of The Manufacturing Thin Wire of TiNi-based Alloys by Using Infrared Radiation
The paper describes the technology of manufacturing a thin nickel-titanium wire through direct exposure to infrared radiation (IR). The effect of IR on the change in the structure of a thin wire made from the TiNi-based alloy was studied during its manufacturing. A comparative analysis of the Ti, Ni and O concentration in the TiNi wire was carried out. The analysis was performed for both a thin wire exposed to infrared radiation and that not exposed to infrared radiation. The wire samples were studied using a scanning electron microscope with the energy dispersive analysis. The infrared radiation effect on the structure of the wire is shown after thermal treatment in the local area of the material.
- Open Access
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 131-139
The Effect Infrared and Ultraviolet Radiation in the Development of the Cells in the Porous Permeable Titanium Nickel Based Alloy Scaffold
The respond of the cells to electromagnetic radiation depends on many factors, including microenvironment. Different cells exhibit different behavior when exposed to low-intensity radiation employed in the research. The effect of infrared (IR) and ultraviolet (UV) radiation leads to the reliable change in the number of viable cells. Viable cells of Ehrlich tumor, spleen and bone marrow of C57BL/6 mice placed in a porous permeable TiNi-based alloy scaffold were studied. The level of the radiation effect was determined for different types of cells. A comparative analysis of the viable cells cultured in the porous permeable TiNi scaffold was performed.
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 131-139
Open AccessThe Effect Infrared and Ultraviolet Radiation in the Development of the Cells in the Porous Permeable Titanium Nickel Based Alloy Scaffold
The respond of the cells to electromagnetic radiation depends on many factors, including microenvironment. Different cells exhibit different behavior when exposed to low-intensity radiation employed in the research. The effect of infrared (IR) and ultraviolet (UV) radiation leads to the reliable change in the number of viable cells. Viable cells of Ehrlich tumor, spleen and bone marrow of C57BL/6 mice placed in a porous permeable TiNi-based alloy scaffold were studied. The level of the radiation effect was determined for different types of cells. A comparative analysis of the viable cells cultured in the porous permeable TiNi scaffold was performed.
- Open Access
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 159-167
The Device for the Treatment of Diabetes with Use of Infrared Radiation and Porous TiNi Based Alloy
The research addresses the problem of design and development of a new needle-free method for diabetes treatment. New porous-permeable TiNi-based materials and new methods of IR-radiation effect on tissues of the body have been used in the research. The properties of porous alloys are similar to those of high-capacity materials that can hold a large volume of insulin solution in the porous structure of the material. With this, IR-radiation stimulates directed diffusion of insulin from the porous TiNi structure to the tissues of the body. This makes the basis for development of a needle-free device for diabetes treatment. The proposed technique does not cause skin irritation, and it is safe when used in practice. The efficiency of insulin delivery was evaluated in clinical studies. The results showed the potential of prolonged delivery for both insulin and other liquids.
- 17 July 2017
- Published by Knowledge E DMCC in KnE Materials Science
- Vol. 2 (1) , 159-167
Open AccessThe Device for the Treatment of Diabetes with Use of Infrared Radiation and Porous TiNi Based Alloy
The research addresses the problem of design and development of a new needle-free method for diabetes treatment. New porous-permeable TiNi-based materials and new methods of IR-radiation effect on tissues of the body have been used in the research. The properties of porous alloys are similar to those of high-capacity materials that can hold a large volume of insulin solution in the porous structure of the material. With this, IR-radiation stimulates directed diffusion of insulin from the porous TiNi structure to the tissues of the body. This makes the basis for development of a needle-free device for diabetes treatment. The proposed technique does not cause skin irritation, and it is safe when used in practice. The efficiency of insulin delivery was evaluated in clinical studies. The results showed the potential of prolonged delivery for both insulin and other liquids.