Mathieu Jean Pierre Pesdjock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mathieu Jean Pierre Pesdjock has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Aristide Tolok Nelem
Higher Technical Teachers’ Training College of the University of Ebolowa, Ebolowa, Cameroon
3 shared publications Fombu Andrew Muluh
3 shared publicationsGodpromesse Kenne
3 shared publicationsLionel Leroy Sonfack
3 shared publications- Pierre Ele
University of Yaoundé I
3 shared publications - Achille Melingui
Department of Electrical and Telecommunications Engineering, Ecole Nationale Suprieure Polytechnique, University of Yaound 1, Yaound, Cameroon
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Politechnika Lubelska in Applied Computer Science
- Vol. 22 (3) , 196-218
Implementation of an IEC 61215-oriented photovoltaic module test emulator with integrated predictive maintenance capabilities
This paper presents a hybrid software-based framework for photovoltaic (PV) testing, monitoring, and predictive maintenance that combines a physically validated PV emulator with data-driven diagnostic models. The emulator reproduces selected IEC 61215-inspired test scenarios, including electrical characterisation, irradiance/temperature variations, simulated accelerated ageing, and electrical fault scenarios—without relying on real solar irradiation, enabling realistic I–V and P–V curve generation under controlled settings for performance assessment and algorithm validation. Note that the emulator is a complementary validation tool and does not substitute for formal IEC 61215 certification. Building on this emulator, a two-stage intelligent monitoring architecture is proposed. First, an unsupervised autoencoder learns normal PV behaviour and detects anomalies by analysing reconstruction errors. It shows strong discriminative capability, achieving a high ROC–AUC while remaining robust across varying environmental conditions, thereby enabling early detection of abrupt faults and progressive degradation. Second, a supervised bidirectional gated recurrent unit (BiGRU) model performs fault classification by explicitly exploiting temporal dependencies in electrical signals. The BiGRU classifier achieves an overall accuracy exceeding 99%, with high class-wise precision and recall across multiple fault categories, including resistive faults, degradation, soiling, and severe electrical failures. The framework is validated on emulator-based and analytically derived datasets (Sandia, Madison, Cenerg models), demonstrating strong generalisation and stability across operating conditions; field validation on real PV installations is identified as a key next step. Overall, integrating physical emulation, unsupervised anomaly detection, and supervised temporal classification provides a robust and scalable predictive maintenance solution for PV installations, particularly in environments with high climatic variability.
- 30 September 2026
- Published by Politechnika Lubelska in Applied Computer Science
- Vol. 22 (3) , 196-218
Open AccessImplementation of an IEC 61215-oriented photovoltaic module test emulator with integrated predictive maintenance capabilities
This paper presents a hybrid software-based framework for photovoltaic (PV) testing, monitoring, and predictive maintenance that combines a physically validated PV emulator with data-driven diagnostic models. The emulator reproduces selected IEC 61215-inspired test scenarios, including electrical characterisation, irradiance/temperature variations, simulated accelerated ageing, and electrical fault scenarios—without relying on real solar irradiation, enabling realistic I–V and P–V curve generation under controlled settings for performance assessment and algorithm validation. Note that the emulator is a complementary validation tool and does not substitute for formal IEC 61215 certification. Building on this emulator, a two-stage intelligent monitoring architecture is proposed. First, an unsupervised autoencoder learns normal PV behaviour and detects anomalies by analysing reconstruction errors. It shows strong discriminative capability, achieving a high ROC–AUC while remaining robust across varying environmental conditions, thereby enabling early detection of abrupt faults and progressive degradation. Second, a supervised bidirectional gated recurrent unit (BiGRU) model performs fault classification by explicitly exploiting temporal dependencies in electrical signals. The BiGRU classifier achieves an overall accuracy exceeding 99%, with high class-wise precision and recall across multiple fault categories, including resistive faults, degradation, soiling, and severe electrical failures. The framework is validated on emulator-based and analytically derived datasets (Sandia, Madison, Cenerg models), demonstrating strong generalisation and stability across operating conditions; field validation on real PV installations is identified as a key next step. Overall, integrating physical emulation, unsupervised anomaly detection, and supervised temporal classification provides a robust and scalable predictive maintenance solution for PV installations, particularly in environments with high climatic variability.
- Open Access
- 20 April 2026
- Published by MDPI AG in Preprints.org
Stochastic Modeling of Space Charge Distortion in HVDC Cables using a Persistent Random Walk Approach
Space charge accumulation is a primary factor in the premature aging and electrical breakdown of High Voltage Direct Current (HVDC) cables. Conventional continuum models often fail to capture the stochastic nature of charge hopping in disordered polymeric insulations like cross-linked polyethylene (XLPE). This paper proposes a novel transport model based on the Persistent Random Walk (PRW) theory, specifically adapted to describe hopping conduction between discrete trap states. We map the trap depth and temperature-dependent Poole-Frenkel release rates to the scattering rate of the PRW. Our simulations demonstrate a strong temperature dependence of the internal electric field. At low temperatures (300 K), carriers remain trapped near the injection electrode, creating a severe local field enhancement (homocharge effect) exceeding 80% of the applied stress. Conversely, as temperature increases, thermal energy facilitates detrapping, leading to charge relaxation and a return to a uniform field distribution. Furthermore, a comparison with Space-Charge-Limited Current (SCLC) theory at the transition temperature (450 K) validates the model, showing the charge packet tail follows a power-law decay with a slope close to the theoretical − 2 / 3 prediction. These results highlight a competing physical mechanism where high temperature mitigates the electrostatic risk associated with space charge, providing critical insights for the design of reliable HVDC insulation systems
- 20 April 2026
- Published by MDPI AG in Preprints.org
Open AccessStochastic Modeling of Space Charge Distortion in HVDC Cables using a Persistent Random Walk Approach
Space charge accumulation is a primary factor in the premature aging and electrical breakdown of High Voltage Direct Current (HVDC) cables. Conventional continuum models often fail to capture the stochastic nature of charge hopping in disordered polymeric insulations like cross-linked polyethylene (XLPE). This paper proposes a novel transport model based on the Persistent Random Walk (PRW) theory, specifically adapted to describe hopping conduction between discrete trap states. We map the trap depth and temperature-dependent Poole-Frenkel release rates to the scattering rate of the PRW. Our simulations demonstrate a strong temperature dependence of the internal electric field. At low temperatures (300 K), carriers remain trapped near the injection electrode, creating a severe local field enhancement (homocharge effect) exceeding 80% of the applied stress. Conversely, as temperature increases, thermal energy facilitates detrapping, leading to charge relaxation and a return to a uniform field distribution. Furthermore, a comparison with Space-Charge-Limited Current (SCLC) theory at the transition temperature (450 K) validates the model, showing the charge packet tail follows a power-law decay with a slope close to the theoretical − 2 / 3 prediction. These results highlight a competing physical mechanism where high temperature mitigates the electrostatic risk associated with space charge, providing critical insights for the design of reliable HVDC insulation systems
- 1 November 2025
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 13 (12) , 1-12
Adaptive third-order sliding mode control of a PMSG supplying a pump with battery storage
- 1 November 2025
- Published by Springer Nature in International Journal of Dynamics and Control
- Vol. 13 (12) , 1-12
Adaptive third-order sliding mode control of a PMSG supplying a pump with battery storage
- 29 May 2025
- Published by Springer Nature in Energy Systems
- p. 1-13
New simplified energy flow management algorithms for a DC bus-coupled photovoltaic-grid hybrid system
- 29 May 2025
- Published by Springer Nature in Energy Systems
- p. 1-13
New simplified energy flow management algorithms for a DC bus-coupled photovoltaic-grid hybrid system
- 11 October 2024
- Published by Elsevier in Progress in Engineering Science
- Vol. 1 (4)
A survey of power system coordinated control algorithms for stability enhancement
- 11 October 2024
- Published by Elsevier in Progress in Engineering Science
- Vol. 1 (4)
A survey of power system coordinated control algorithms for stability enhancement
- Open Access
- 8 May 2024
- Published by Elsevier in Scientific African
- Vol. 24
Lithium-ion point-of-care ultrasound battery joint state of charge estimation
- 8 May 2024
- Published by Elsevier in Scientific African
- Vol. 24
Open AccessLithium-ion point-of-care ultrasound battery joint state of charge estimation
- Open Access
- 7 May 2024
- Published by Elsevier in Scientific African
- Vol. 24
Qualitative performance improvement of a hybrid power supply at the DC common coupling point using a neuro-fuzzy method
- 7 May 2024
- Published by Elsevier in Scientific African
- Vol. 24
Open AccessQualitative performance improvement of a hybrid power supply at the DC common coupling point using a neuro-fuzzy method
- Open Access
- 5 May 2024
- Published by IAES Indonesia Section in Indonesian Journal of Electrical Engineering and Informatics (IJEEI)
- Vol. 12 (2) , 397-408
A Simple Lyapunov Function Based Control Strategy for Coordinated Transient Stability Enhancement of Power Systems
A Simple Lyapunov Function Based Control Strategy for Coordinated Transient Stability Enhancement of Power Systems
- 5 May 2024
- Published by IAES Indonesia Section in Indonesian Journal of Electrical Engineering and Informatics (IJEEI)
- Vol. 12 (2) , 397-408
Open AccessA Simple Lyapunov Function Based Control Strategy for Coordinated Transient Stability Enhancement of Power Systems
A Simple Lyapunov Function Based Control Strategy for Coordinated Transient Stability Enhancement of Power Systems
- Open Access
- 16 October 2023
- Published by Elsevier in Energy Reports
- Vol. 10, 3619-3628
A simple fuzzy logic based DC link energy management system for hybrid industrial power supply
- 16 October 2023
- Published by Elsevier in Energy Reports
- Vol. 10, 3619-3628
Open AccessA simple fuzzy logic based DC link energy management system for hybrid industrial power supply