ANAristide Tolok Nelem

Aristide Tolok Nelem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aristide Tolok Nelem has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • ITIC-SEI: A Measurement-Driven Severity Exposure Index for Site-Level Mapping of Voltage Dips in Cameroonian Hospitals

    by Aristide Tolok Nelem, Yannick Antoine Abanda, Steyve Samson Nyatte, Mimosette Makem, Mathieu Jean Pierre Pesdjock, Achille Melingui, Pierre Ele

  • Open Access

    Implementation of an IEC 61215-oriented photovoltaic module test emulator with integrated predictive maintenance capabilities

    by Aristide Tolok Nelem, Yannick Antoine Abanda, Steyve Samson Nyatte, Mathieu Jean Pierre Pesdjock, Achille Melingui, Pierre Ele

    This paper presents a hybrid software-based framework for photovoltaic (PV) testing, monitoring, and predictive maintenance that combines a physically validated PV emulator with data-driven diagnostic models. The emulator reproduces selected IEC 61215-inspired test scenarios, including electrical characterisation, irradiance/temperature variations, simulated accelerated ageing, and electrical fault scenarios—without relying on real solar irradiation, enabling realistic I–V and P–V curve generation under controlled settings for performance assessment and algorithm validation. Note that the emulator is a complementary validation tool and does not substitute for formal IEC 61215 certification. Building on this emulator, a two-stage intelligent monitoring architecture is proposed. First, an unsupervised autoencoder learns normal PV behaviour and detects anomalies by analysing reconstruction errors. It shows strong discriminative capability, achieving a high ROC–AUC while remaining robust across varying environmental conditions, thereby enabling early detection of abrupt faults and progressive degradation. Second, a supervised bidirectional gated recurrent unit (BiGRU) model performs fault classification by explicitly exploiting temporal dependencies in electrical signals. The BiGRU classifier achieves an overall accuracy exceeding 99%, with high class-wise precision and recall across multiple fault categories, including resistive faults, degradation, soiling, and severe electrical failures. The framework is validated on emulator-based and analytically derived datasets (Sandia, Madison, Cenerg models), demonstrating strong generalisation and stability across operating conditions; field validation on real PV installations is identified as a key next step. Overall, integrating physical emulation, unsupervised anomaly detection, and supervised temporal classification provides a robust and scalable predictive maintenance solution for PV installations, particularly in environments with high climatic variability.

  • Open Access

    Power quality analysis and energy consumption monitoring across hospitals in Cameroon

    by Aristide Tolok Nelem, Yannick Antoine Abanda, Théodore Patrice Nna Nna, Junior Ngaba Mbezele, Pierre Ele

    The quality of electrical supply is the main cause of premature failure of biomedical equipment in Cameroon, where nearly 95% of hospital devices are imported and designed to operate under stable mains conditions. This study, based on real hospital data, utilises data collected by CURES (University Centre for Energy Research in Healthcare) in four Cameroonian hospitals. The data collection yielded 3,474 ten-minute intervals. A model-free algorithm enabled, in turn: the profiling of regulatory compliance against the EN 50160 and IEEE 519-2014 standards; the detection of anomalies via SPE and Hotelling’s T2 statistics derived from PCA; the localization of faults through residual structuring; unsupervised classification using the K-means method validated by the elbow and silhouette criteria; and finally, the modelling of temporal dependence via a robust vector autoregressive model with parameter estimation based on the M-estimator. Four disturbance profiles were identified. A Spearman’s correlation of ρ = −1.00 between anomaly rates and compliance scores indicates the internal consistency between the compliance scoring and the anomaly detection outputs. With a frequency compliance rate of 28.9% and a score of 47.8%, Djoum Hospital is the most critical site, while Obala achieved the highest score (72.6%). These results highlight the urgent need to deploy reactive compensation and frequency stabilisation systems in the rural hospital facilities included in this study.

  • A Low-Offset and High-Speed Latch Comparator with Single Tail-Clocked Inverter Preamplifier for High-Resolution Applications

    by Pancha Yannick Hertz, Aristide Tolok Nelem, Folla Kamdem Jerome, Wembe Tafo Evariste, Essimbi Zobo Bernard

    Dynamic Latch Comparators (DLC) are among the most crucial building blocks in many analog mixed-signal circuits. This research report focuses on the design of an improved dynamic latch comparator for high-speed applications. The proposed circuit consists of a two-stage comparator, a preamplifier, and a latch. The preamplifier is an single tail clocked inverter-based amplifier. This will provide low power consumption, excellent kickback noise immunity and low input-referred offset. The latch stage, which is the main contribution, consists of complementary input transistors to improve gain before the decision, acting like a three-stage comparator. Moreover, a reset switch is added to set the precharge point to [Formula: see text], thereby improving comparison speed. The circuit is implemented in 65[Formula: see text]nm CMOS technology with a 1[Formula: see text]V power supply. The proposed circuit exhibits a low power delay product of 10.8[Formula: see text]fJ, corresponding to an energy per comparison of 4.32[Formula: see text]fJ/GHz, for a 2.5[Formula: see text]GHz maximum clock frequency. The extracted offset shows a significant improvement of 78.5% over the conventional DLC. The die area of the circuit is about 108.54[Formula: see text] [Formula: see text]m 2 .

  • Open Access

    Contribution to the Development of a Smart Ultrasound Scanner: Design and Analysis of the High-Voltage Power Supply of the Transmitter

    by Nicolas Daniel Mbele Ndzana, Claude Bernard Lekini Nkodo, Aristide Tolok Nelem, Mathieu Jean Pierre Pesdjock, Yannick Antoine Abanda, Achille Melingui, Odile Fernande Zeh, Pierre Ele

    A smart ultrasound scanner plays an important role in the transition to point-of-care imaging. DC–DC bipolar converters are essential in the generation of the ultrasound burst signal as they power the piezoelectric transducer. The conventional bipolar converter has minimal output gain and high-voltage stress, and the longer duty cycle on the semiconductors produces high conduction losses and reduces the efficiency of the system. The transmitter supply voltage is minimal, necessitating the use of high-gain bipolar converters. This proposed study is concerned with the development of an improved high-output voltage gain symmetric bipolar DC–DC converter topology which may be suitable for applications such as powering a smart ultrasound scanner transmitter. The proposed converter combines the conventional single-ended primary inductor converter (SEPIC) with a voltage multiplier cell (VMC) to improve voltage gain, transistor duty cycle, efficiency, and reliability. The present study describes the working principle of the proposed converter. The analysis of the voltage gain is carried out in continuous current mode (CCM) and discontinuous current mode (DCM), taking into account the nonidealities of the device. The simulation of the proposed system is carried out in the numerical environment Matlab/Simulink in order to verify its characteristics. A prototype model is realized and the experimental study presented validates the theoretical arguments and simulations. Due to the advantages of continuous input current, self-balancing bipolar outputs, and small component size, the proposed converter is a suitable choice for smart ultrasound transmitters.


  • Dynamic Optimization of Switching States of an Hybrid Power Network

    by Aristide Tolok Nelem, Pierre Ele, Papa Alioune Ndiaye, Salomé Ndjakomo Essiane, Mathieu Jean Pierre Pesdjock