Pierre Ele
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pierre Ele has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Aristide Tolok Nelem
Higher Technical Teachers’ Training College of the University of Ebolowa, Ebolowa, Cameroon
4 shared publications - Achille Melingui
Department of Electrical and Telecommunications Engineering, Ecole Nationale Suprieure Polytechnique, University of Yaound 1, Yaound, Cameroon
3 shared publications - Mathieu Jean Pierre Pesdjock
University of Ebolowa
3 shared publications - Yannick Antoine Abanda
University of Ebolowa
3 shared publications - Alexandre Teplaira Boum
University of Douala
2 shared publications - Camille Franklin Mbey
University of Douala
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Politechnika Lubelska in Applied Computer Science
- Vol. 22 (3) , 196-218
Implementation of an IEC 61215-oriented photovoltaic module test emulator with integrated predictive maintenance capabilities
This paper presents a hybrid software-based framework for photovoltaic (PV) testing, monitoring, and predictive maintenance that combines a physically validated PV emulator with data-driven diagnostic models. The emulator reproduces selected IEC 61215-inspired test scenarios, including electrical characterisation, irradiance/temperature variations, simulated accelerated ageing, and electrical fault scenarios—without relying on real solar irradiation, enabling realistic I–V and P–V curve generation under controlled settings for performance assessment and algorithm validation. Note that the emulator is a complementary validation tool and does not substitute for formal IEC 61215 certification. Building on this emulator, a two-stage intelligent monitoring architecture is proposed. First, an unsupervised autoencoder learns normal PV behaviour and detects anomalies by analysing reconstruction errors. It shows strong discriminative capability, achieving a high ROC–AUC while remaining robust across varying environmental conditions, thereby enabling early detection of abrupt faults and progressive degradation. Second, a supervised bidirectional gated recurrent unit (BiGRU) model performs fault classification by explicitly exploiting temporal dependencies in electrical signals. The BiGRU classifier achieves an overall accuracy exceeding 99%, with high class-wise precision and recall across multiple fault categories, including resistive faults, degradation, soiling, and severe electrical failures. The framework is validated on emulator-based and analytically derived datasets (Sandia, Madison, Cenerg models), demonstrating strong generalisation and stability across operating conditions; field validation on real PV installations is identified as a key next step. Overall, integrating physical emulation, unsupervised anomaly detection, and supervised temporal classification provides a robust and scalable predictive maintenance solution for PV installations, particularly in environments with high climatic variability.
- 30 September 2026
- Published by Politechnika Lubelska in Applied Computer Science
- Vol. 22 (3) , 196-218
Open AccessImplementation of an IEC 61215-oriented photovoltaic module test emulator with integrated predictive maintenance capabilities
This paper presents a hybrid software-based framework for photovoltaic (PV) testing, monitoring, and predictive maintenance that combines a physically validated PV emulator with data-driven diagnostic models. The emulator reproduces selected IEC 61215-inspired test scenarios, including electrical characterisation, irradiance/temperature variations, simulated accelerated ageing, and electrical fault scenarios—without relying on real solar irradiation, enabling realistic I–V and P–V curve generation under controlled settings for performance assessment and algorithm validation. Note that the emulator is a complementary validation tool and does not substitute for formal IEC 61215 certification. Building on this emulator, a two-stage intelligent monitoring architecture is proposed. First, an unsupervised autoencoder learns normal PV behaviour and detects anomalies by analysing reconstruction errors. It shows strong discriminative capability, achieving a high ROC–AUC while remaining robust across varying environmental conditions, thereby enabling early detection of abrupt faults and progressive degradation. Second, a supervised bidirectional gated recurrent unit (BiGRU) model performs fault classification by explicitly exploiting temporal dependencies in electrical signals. The BiGRU classifier achieves an overall accuracy exceeding 99%, with high class-wise precision and recall across multiple fault categories, including resistive faults, degradation, soiling, and severe electrical failures. The framework is validated on emulator-based and analytically derived datasets (Sandia, Madison, Cenerg models), demonstrating strong generalisation and stability across operating conditions; field validation on real PV installations is identified as a key next step. Overall, integrating physical emulation, unsupervised anomaly detection, and supervised temporal classification provides a robust and scalable predictive maintenance solution for PV installations, particularly in environments with high climatic variability.
- Open Access
- 7 September 2026
- Published by Universe Scientific Publishing Pte. Ltd. in Clean Energy Science and Technology
Power quality analysis and energy consumption monitoring across hospitals in Cameroon
The quality of electrical supply is the main cause of premature failure of biomedical equipment in Cameroon, where nearly 95% of hospital devices are imported and designed to operate under stable mains conditions. This study, based on real hospital data, utilises data collected by CURES (University Centre for Energy Research in Healthcare) in four Cameroonian hospitals. The data collection yielded 3,474 ten-minute intervals. A model-free algorithm enabled, in turn: the profiling of regulatory compliance against the EN 50160 and IEEE 519-2014 standards; the detection of anomalies via SPE and Hotelling’s T2 statistics derived from PCA; the localization of faults through residual structuring; unsupervised classification using the K-means method validated by the elbow and silhouette criteria; and finally, the modelling of temporal dependence via a robust vector autoregressive model with parameter estimation based on the M-estimator. Four disturbance profiles were identified. A Spearman’s correlation of ρ = −1.00 between anomaly rates and compliance scores indicates the internal consistency between the compliance scoring and the anomaly detection outputs. With a frequency compliance rate of 28.9% and a score of 47.8%, Djoum Hospital is the most critical site, while Obala achieved the highest score (72.6%). These results highlight the urgent need to deploy reactive compensation and frequency stabilisation systems in the rural hospital facilities included in this study.
- 7 September 2026
- Published by Universe Scientific Publishing Pte. Ltd. in Clean Energy Science and Technology
Open AccessPower quality analysis and energy consumption monitoring across hospitals in Cameroon
The quality of electrical supply is the main cause of premature failure of biomedical equipment in Cameroon, where nearly 95% of hospital devices are imported and designed to operate under stable mains conditions. This study, based on real hospital data, utilises data collected by CURES (University Centre for Energy Research in Healthcare) in four Cameroonian hospitals. The data collection yielded 3,474 ten-minute intervals. A model-free algorithm enabled, in turn: the profiling of regulatory compliance against the EN 50160 and IEEE 519-2014 standards; the detection of anomalies via SPE and Hotelling’s T2 statistics derived from PCA; the localization of faults through residual structuring; unsupervised classification using the K-means method validated by the elbow and silhouette criteria; and finally, the modelling of temporal dependence via a robust vector autoregressive model with parameter estimation based on the M-estimator. Four disturbance profiles were identified. A Spearman’s correlation of ρ = −1.00 between anomaly rates and compliance scores indicates the internal consistency between the compliance scoring and the anomaly detection outputs. With a frequency compliance rate of 28.9% and a score of 47.8%, Djoum Hospital is the most critical site, while Obala achieved the highest score (72.6%). These results highlight the urgent need to deploy reactive compensation and frequency stabilisation systems in the rural hospital facilities included in this study.
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 40 (3)
Fuzzy logic control of a hybrid PV/battery/diesel generator system integrated in an electrical network: case study of City of Douala
The control of hybrid systems is a considerable challenge for the energy supply to consumers. For this purpose, this study implemented an intelligent control for a hybrid system connected to the electrical grid to meet the energy demand of a building in the city of Douala, Cameroon. In this work, an intelligent management system using fuzzy logic is proposed to overcome the challenges of this multi-source integration. The proposed method based on a fuzzy logic controller makes it possible to optimize the performance of the energy sources used with a coordination system. Thus, it makes it possible to adjust in real time the system control process based on climatic conditions and the characteristics of the storage devices in order to provide an adequate adaptive control strategy. Furthermore, this system effectively balances the energy supply from all sources. MATLAB/Simulink software and real building data are used to simulate the proposed intelligent management strategy. The results obtained indicate that energy is efficiently supplied to consumers with efficiency of 98% and reduction of fuel consumption of 45% based on the availability of the sources, thus demonstrating the benefits of the control strategy based on fuzzy logic for balanced system operation.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 40 (3)
Open AccessFuzzy logic control of a hybrid PV/battery/diesel generator system integrated in an electrical network: case study of City of Douala
The control of hybrid systems is a considerable challenge for the energy supply to consumers. For this purpose, this study implemented an intelligent control for a hybrid system connected to the electrical grid to meet the energy demand of a building in the city of Douala, Cameroon. In this work, an intelligent management system using fuzzy logic is proposed to overcome the challenges of this multi-source integration. The proposed method based on a fuzzy logic controller makes it possible to optimize the performance of the energy sources used with a coordination system. Thus, it makes it possible to adjust in real time the system control process based on climatic conditions and the characteristics of the storage devices in order to provide an adequate adaptive control strategy. Furthermore, this system effectively balances the energy supply from all sources. MATLAB/Simulink software and real building data are used to simulate the proposed intelligent management strategy. The results obtained indicate that energy is efficiently supplied to consumers with efficiency of 98% and reduction of fuel consumption of 45% based on the availability of the sources, thus demonstrating the benefits of the control strategy based on fuzzy logic for balanced system operation.
- Open Access
- 31 January 2025
- Published by ADBA Information Technology and Publishing Limited Company in Chaos and Fractals
- Vol. 2 (1) , 14-19
Permanent Magnet Synchronous Motor with Load Torque: Dynamics, Circuitry Execution and Control
This paper is interested in the study of the dynamics and control of the permanent magnet synchronous motor with load torque (PMSMLT). PMSMLT has three fixed points where one is saddle and the two others are saddle focus. PMSMLT exhibits no oscillations, periodic characteristics, chaotic characteristics and coexistence between no oscillations and chaotic characteristics. In order to validate the results obtained numerically, an electronic implementation of PMSMLT is performed in probe simulation program with integrated circuit emphases (PSPICE) environment which reveals a concordance between the numerical simulations and the experimental verifications. The coexisting characteristics is eliminated by the linear augmentation control method.
- 31 January 2025
- Published by ADBA Information Technology and Publishing Limited Company in Chaos and Fractals
- Vol. 2 (1) , 14-19
Open AccessPermanent Magnet Synchronous Motor with Load Torque: Dynamics, Circuitry Execution and Control
This paper is interested in the study of the dynamics and control of the permanent magnet synchronous motor with load torque (PMSMLT). PMSMLT has three fixed points where one is saddle and the two others are saddle focus. PMSMLT exhibits no oscillations, periodic characteristics, chaotic characteristics and coexistence between no oscillations and chaotic characteristics. In order to validate the results obtained numerically, an electronic implementation of PMSMLT is performed in probe simulation program with integrated circuit emphases (PSPICE) environment which reveals a concordance between the numerical simulations and the experimental verifications. The coexisting characteristics is eliminated by the linear augmentation control method.
- Open Access
- 3 September 2023
- Published by MDPI AG in Inventions
- Vol. 8 (5) , 113
Contribution to the Development of a Smart Ultrasound Scanner: Design and Analysis of the High-Voltage Power Supply of the Transmitter
A smart ultrasound scanner plays an important role in the transition to point-of-care imaging. DC–DC bipolar converters are essential in the generation of the ultrasound burst signal as they power the piezoelectric transducer. The conventional bipolar converter has minimal output gain and high-voltage stress, and the longer duty cycle on the semiconductors produces high conduction losses and reduces the efficiency of the system. The transmitter supply voltage is minimal, necessitating the use of high-gain bipolar converters. This proposed study is concerned with the development of an improved high-output voltage gain symmetric bipolar DC–DC converter topology which may be suitable for applications such as powering a smart ultrasound scanner transmitter. The proposed converter combines the conventional single-ended primary inductor converter (SEPIC) with a voltage multiplier cell (VMC) to improve voltage gain, transistor duty cycle, efficiency, and reliability. The present study describes the working principle of the proposed converter. The analysis of the voltage gain is carried out in continuous current mode (CCM) and discontinuous current mode (DCM), taking into account the nonidealities of the device. The simulation of the proposed system is carried out in the numerical environment Matlab/Simulink in order to verify its characteristics. A prototype model is realized and the experimental study presented validates the theoretical arguments and simulations. Due to the advantages of continuous input current, self-balancing bipolar outputs, and small component size, the proposed converter is a suitable choice for smart ultrasound transmitters.
- 3 September 2023
- Published by MDPI AG in Inventions
- Vol. 8 (5) , 113
Open AccessContribution to the Development of a Smart Ultrasound Scanner: Design and Analysis of the High-Voltage Power Supply of the Transmitter
A smart ultrasound scanner plays an important role in the transition to point-of-care imaging. DC–DC bipolar converters are essential in the generation of the ultrasound burst signal as they power the piezoelectric transducer. The conventional bipolar converter has minimal output gain and high-voltage stress, and the longer duty cycle on the semiconductors produces high conduction losses and reduces the efficiency of the system. The transmitter supply voltage is minimal, necessitating the use of high-gain bipolar converters. This proposed study is concerned with the development of an improved high-output voltage gain symmetric bipolar DC–DC converter topology which may be suitable for applications such as powering a smart ultrasound scanner transmitter. The proposed converter combines the conventional single-ended primary inductor converter (SEPIC) with a voltage multiplier cell (VMC) to improve voltage gain, transistor duty cycle, efficiency, and reliability. The present study describes the working principle of the proposed converter. The analysis of the voltage gain is carried out in continuous current mode (CCM) and discontinuous current mode (DCM), taking into account the nonidealities of the device. The simulation of the proposed system is carried out in the numerical environment Matlab/Simulink in order to verify its characteristics. A prototype model is realized and the experimental study presented validates the theoretical arguments and simulations. Due to the advantages of continuous input current, self-balancing bipolar outputs, and small component size, the proposed converter is a suitable choice for smart ultrasound transmitters.
- 30 March 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (4) , 045025
Exploitation of second-and fourth-order PDEs to improve Lossy compression of noisy images
This paper presents a lossy compression method for noisy images. The main contributions in this paper are: improve the performance of noisy image compression algorithms by using partial differential equations (PDEs) as an image preprocessing filter and show that it is more advantageous to apply a restoration filter before compressing noise images. Method: The preprocessing filter is applied to the noisy image first. A comparing of the obtained outcomes with those in the scientific literature devoted to the restoration of noisy images is performed. The filtered image is then submitted to a compression algorithm. The compression algorithm employed is a hybrid of the following: DWT + SPIHT + HUFFMAN. Results: The simulation results demonstrate that the suggested technique is as efficient as approaches described in the scientific literature for picture compression and/or image restoration.
- 30 March 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (4) , 045025
Exploitation of second-and fourth-order PDEs to improve Lossy compression of noisy images
This paper presents a lossy compression method for noisy images. The main contributions in this paper are: improve the performance of noisy image compression algorithms by using partial differential equations (PDEs) as an image preprocessing filter and show that it is more advantageous to apply a restoration filter before compressing noise images. Method: The preprocessing filter is applied to the noisy image first. A comparing of the obtained outcomes with those in the scientific literature devoted to the restoration of noisy images is performed. The filtered image is then submitted to a compression algorithm. The compression algorithm employed is a hybrid of the following: DWT + SPIHT + HUFFMAN. Results: The simulation results demonstrate that the suggested technique is as efficient as approaches described in the scientific literature for picture compression and/or image restoration.
- Open Access
- 8 November 2022
- Published by Wiley in International Journal of Photoenergy
- Vol. 2022, 1-14
Fault Detection and Classification of a Photovoltaic Generator Using the BES Optimization Algorithm Associated with SVM
In this work, an innovative approach based on the estimation of the photovoltaic generator (GPV) parameters from the Bald Eagle Search (BES) optimization algorithm, associated with a support vector machine (SVM) classification algorithm, allowed to highlight a new tool for the classification of the signatures of shading and moisture PV defects. It recognizes signatures generated by the GPV in healthy and erroneous operation using the optimized parametric vector and classifies defects using the same optimized vector. The technique emphasizes the resilience of parameter estimate in terms of error on all parameters. The classification accuracy is 93. The residuals between the estimated curve in healthy operation with a minimum error of the order of 10-4 and the one at fault are used as an indicator of faults.
- 8 November 2022
- Published by Wiley in International Journal of Photoenergy
- Vol. 2022, 1-14
Open AccessFault Detection and Classification of a Photovoltaic Generator Using the BES Optimization Algorithm Associated with SVM
In this work, an innovative approach based on the estimation of the photovoltaic generator (GPV) parameters from the Bald Eagle Search (BES) optimization algorithm, associated with a support vector machine (SVM) classification algorithm, allowed to highlight a new tool for the classification of the signatures of shading and moisture PV defects. It recognizes signatures generated by the GPV in healthy and erroneous operation using the optimized parametric vector and classifies defects using the same optimized vector. The technique emphasizes the resilience of parameter estimate in terms of error on all parameters. The classification accuracy is 93. The residuals between the estimated curve in healthy operation with a minimum error of the order of 10-4 and the one at fault are used as an indicator of faults.
- Open Access
- 30 July 2022
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 15, 100273
Optimal design of the modelling parameters of photovoltaic modules and array through metaheuristic with Secant method
- 30 July 2022
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 15, 100273
Open AccessOptimal design of the modelling parameters of photovoltaic modules and array through metaheuristic with Secant method
- Open Access
- 10 May 2022
- Published by Hindawi Limited in Applied Computational Intelligence and Soft Computing
- Vol. 2022, 1-14
A Novel Smart Method for State Estimation in a Smart Grid Using Smart Meter Data
Smart grids have brought new possibilities in power grid operations for control and monitoring. For this purpose, state estimation is considered as one of the effective techniques in the monitoring and analysis of smart grids. State estimation uses a processing algorithm based on data from smart meters. The major challenge for state estimation is to take into account this large volume of measurement data. In this article, a novel smart distribution network state estimation algorithm has been proposed. The proposed method is a combined high-gain state estimation algorithm named adaptive extended Kalman filter (AEKF) using extended Kalman filter (EKF) and unscented Kalman filter (UKF) in order to achieve better intelligent utility grid state estimation accuracy. The performance index and the error are indicators used to evaluate the accuracy of the estimation models in this article. An IEEE 37-node test network is used to implement the state estimation models. The state variables considered in this article are the voltage module at the measurement nodes. The results obtained show that the proposed hybrid algorithm has better performance compared to single state estimation methods such as the extended Kalman filter, the unscented Kalman filter, and the weighted least squares (WLS) method.
- 10 May 2022
- Published by Hindawi Limited in Applied Computational Intelligence and Soft Computing
- Vol. 2022, 1-14
Open AccessA Novel Smart Method for State Estimation in a Smart Grid Using Smart Meter Data
Smart grids have brought new possibilities in power grid operations for control and monitoring. For this purpose, state estimation is considered as one of the effective techniques in the monitoring and analysis of smart grids. State estimation uses a processing algorithm based on data from smart meters. The major challenge for state estimation is to take into account this large volume of measurement data. In this article, a novel smart distribution network state estimation algorithm has been proposed. The proposed method is a combined high-gain state estimation algorithm named adaptive extended Kalman filter (AEKF) using extended Kalman filter (EKF) and unscented Kalman filter (UKF) in order to achieve better intelligent utility grid state estimation accuracy. The performance index and the error are indicators used to evaluate the accuracy of the estimation models in this article. An IEEE 37-node test network is used to implement the state estimation models. The state variables considered in this article are the voltage module at the measurement nodes. The results obtained show that the proposed hybrid algorithm has better performance compared to single state estimation methods such as the extended Kalman filter, the unscented Kalman filter, and the weighted least squares (WLS) method.