Michael Bressack
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael Bressack has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Ames
Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, Massachusetts 02138, USA
2 shared publications - Brian Mong
SLAC National Accelerator Laboratory
2 shared publications - Christina M Ignarra
SLAC National Accelerator Laboratory Palo Alto, CA United States
2 shared publications - Daniel S. Akerib
SLAC Natl Accelerator Lab, 2575 Sand Hill Rd, Menlo Pk, CA 94205 USA
2 shared publications - David M. Gaba
Stanford University School of Medicine, Stanford, CA, USA
2 shared publications - Eric Charles
SLAC National Accelerator Laboratory
2 shared publications
Latest Publications
- Open Access
- 5 August 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (3) , e26047
A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing
Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.
- 5 August 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (3) , e26047
Open AccessA Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing
Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.
- Open Access
- 30 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)
BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL
- 30 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)
BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL