Pallav Kumar Bera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pallav Kumar Bera has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Can Isik
Syracuse University, Syracuse, NY 13244, USA
4 shared publications - Vajendra Kumar
Indian Institute of Technology, Roorkee, India
4 shared publications - Samita Rani Pani
School of Electrical Engineering, Kalinga Institute of Industrial Technology (KIIT), Bhubaneswar, Odisha, India
2 shared publications Can Isik
1 shared publication- Hassan Haes Alhelou
School of Engineering, Massachusetts Institute of Technology (MIT), Cambridge, MA, USA
1 shared publication - Himadri Sekhar Chatterjee
Department of Electrical Engineering, National Institute of Technology Durgapur, Durgapur, India
1 shared publication
Latest Publications
- Open Access
- 8 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Intelligent Detection of High Impedance Faults in Microgrid Distribution Lines Using Optimized Machine Learning Models
This paper presents a data-driven protection scheme for high impedance fault (HIF) classification in microgrids. Conventional overcurrent protection often lacks the sensitivity to detect HIFs because of their low current magnitude and nonlinear characteristics. To address these limitations, we investigate an approach based on multiple machine learning (ML) classifier models for distribution line fault diagnosis. The proposed technique trains ML classifiers directly on raw three-phase differential current signals, allowing the models to autonomously learn patterns without manual feature extraction. The classifiers are optimized through a grid-search procedure and evaluated using a PSCAD/EMTDC model of a 5-bus AC microgrid test system with distributed generations (DGs) operating in both grid-connected and islanded modes. The generated dataset includes healthy conditions, internal faults (with/without HIF), and external faults with current transformer (CT) saturation. Nine ML models are assessed using accuracy, precision, recall, F1-score, receiver operating characteristic (ROC) analysis, computational cost, and noise sensitivity tests. The results indicate that the feedforward neural network (FFNN), random forest (RF), and stochastic gradient descent (SGD) classifiers exhibit robust and consistent classification performance on the test set. Significantly, even when using raw input data, the proposed methodology effectively discriminates subtle HIF signatures from other transient events and CT saturation conditions. These findings highlight the potential of optimized ML models, particularly FFNN and RF classifiers, to provide accurate and robust support for real-time microgrid protection.
- 8 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Open AccessIntelligent Detection of High Impedance Faults in Microgrid Distribution Lines Using Optimized Machine Learning Models
This paper presents a data-driven protection scheme for high impedance fault (HIF) classification in microgrids. Conventional overcurrent protection often lacks the sensitivity to detect HIFs because of their low current magnitude and nonlinear characteristics. To address these limitations, we investigate an approach based on multiple machine learning (ML) classifier models for distribution line fault diagnosis. The proposed technique trains ML classifiers directly on raw three-phase differential current signals, allowing the models to autonomously learn patterns without manual feature extraction. The classifiers are optimized through a grid-search procedure and evaluated using a PSCAD/EMTDC model of a 5-bus AC microgrid test system with distributed generations (DGs) operating in both grid-connected and islanded modes. The generated dataset includes healthy conditions, internal faults (with/without HIF), and external faults with current transformer (CT) saturation. Nine ML models are assessed using accuracy, precision, recall, F1-score, receiver operating characteristic (ROC) analysis, computational cost, and noise sensitivity tests. The results indicate that the feedforward neural network (FFNN), random forest (RF), and stochastic gradient descent (SGD) classifiers exhibit robust and consistent classification performance on the test set. Significantly, even when using raw input data, the proposed methodology effectively discriminates subtle HIF signatures from other transient events and CT saturation conditions. These findings highlight the potential of optimized ML models, particularly FFNN and RF classifiers, to provide accurate and robust support for real-time microgrid protection.
- 27 August 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 237
A hybrid intelligent system for protection of transmission lines connected to PV farms based on linear trends
- 27 August 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 237
A hybrid intelligent system for protection of transmission lines connected to PV farms based on linear trends
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 71-82
Autoregressive Coefficients Based Intelligent Protection of Transmission Lines Connected to Type-3 Wind Farms
Protective relays can mal-operate for transmission lines connected to doubly fed induction generator (DFIG) based large capacity wind farms (WFs). The performance of distance relays protecting such lines is investigated and a statistical model based intelligent protection of the area between the grid and the WF is proposed in this article. The suggested method employs an adaptive fuzzy inference system to detect faults based on autoregressive (AR) coefficients of the 3-phase currents selected using minimum redundancy maximum relevance algorithm. Deep learning networks are used to supervise the detection of faults, their subsequent localization, and classification. The effectiveness of the scheme is evaluated on IEEE 9-bus and IEEE 39-bus systems with varying fault resistances, fault inception times, locations, fault types, wind speeds, and transformer connections. Further, the impact of factors like the presence of type-4 WFs, double circuit lines, WF capacity, grid strength, FACTs devices, reclosing on permanent faults, power swings, fault during power swings, voltage instability, load encroachment, high impedance faults, evolving and cross-country faults, close-in and remote-end faults, CT saturation, sampling rate, data window size, synchronization error, noise, and semi-supervised learning are considered while validating the proposed scheme. The results show the efficacy of the suggested method in dealing with various system conditions and configurations while protecting the transmission lines that are connected to WFs.
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 71-82
Autoregressive Coefficients Based Intelligent Protection of Transmission Lines Connected to Type-3 Wind Farms
Protective relays can mal-operate for transmission lines connected to doubly fed induction generator (DFIG) based large capacity wind farms (WFs). The performance of distance relays protecting such lines is investigated and a statistical model based intelligent protection of the area between the grid and the WF is proposed in this article. The suggested method employs an adaptive fuzzy inference system to detect faults based on autoregressive (AR) coefficients of the 3-phase currents selected using minimum redundancy maximum relevance algorithm. Deep learning networks are used to supervise the detection of faults, their subsequent localization, and classification. The effectiveness of the scheme is evaluated on IEEE 9-bus and IEEE 39-bus systems with varying fault resistances, fault inception times, locations, fault types, wind speeds, and transformer connections. Further, the impact of factors like the presence of type-4 WFs, double circuit lines, WF capacity, grid strength, FACTs devices, reclosing on permanent faults, power swings, fault during power swings, voltage instability, load encroachment, high impedance faults, evolving and cross-country faults, close-in and remote-end faults, CT saturation, sampling rate, data window size, synchronization error, noise, and semi-supervised learning are considered while validating the proposed scheme. The results show the efficacy of the suggested method in dealing with various system conditions and configurations while protecting the transmission lines that are connected to WFs.
- 7 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (3) , 3425-3435
An Enhanced Protective Relaying Scheme for TCSC Compensated Line Connecting DFIG-Based Wind Farm
The electricity generated from the present-day large capacity doubly fed induction generator (DFIG) installed wind farm is generally transmitted to utility grid via medium or high voltage transmission line (TL). Due to the restriction of building new TLs, series compensated TLs are some cases preferred for such applications. But, the nonlinear output power versus wind speed relation, control strategies of power electronic interfaced DFIG-wind turbine generators and the nonlinear operation of the thyristor-controlled series capacitor (TCSC) during fault impose adverse impact on the performance of the conventionally used distance relaying-based TL protection schemes. In this article, an improved fault detection and classification technique is proposed to assist distance relay in ensuring fast and reliable protection to TCSC compensated TL linked to DFIG-installed wind farm. In this method, a feature called transient monitoring indexed (TMI) is derived from the measured three-phase currents at the relay location for fault detection and TMI-assisted support vector machine is employed further for fault classification. Performance of the proposed scheme is validated on various fault and nonfault transients simulated on a test power system through MATLAB/Simulink. This protective scheme is farther validated throughout real-time assembled dSPACE DS 1104 control prototype hardware. The superiority of the proposed method is also demonstrated through comparative assessment results with few existing techniques. The overall results justify the merits of the proposed method for fast and accurate detection and classification of faults in such crucial TLs.
- 7 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (3) , 3425-3435
An Enhanced Protective Relaying Scheme for TCSC Compensated Line Connecting DFIG-Based Wind Farm
The electricity generated from the present-day large capacity doubly fed induction generator (DFIG) installed wind farm is generally transmitted to utility grid via medium or high voltage transmission line (TL). Due to the restriction of building new TLs, series compensated TLs are some cases preferred for such applications. But, the nonlinear output power versus wind speed relation, control strategies of power electronic interfaced DFIG-wind turbine generators and the nonlinear operation of the thyristor-controlled series capacitor (TCSC) during fault impose adverse impact on the performance of the conventionally used distance relaying-based TL protection schemes. In this article, an improved fault detection and classification technique is proposed to assist distance relay in ensuring fast and reliable protection to TCSC compensated TL linked to DFIG-installed wind farm. In this method, a feature called transient monitoring indexed (TMI) is derived from the measured three-phase currents at the relay location for fault detection and TMI-assisted support vector machine is employed further for fault classification. Performance of the proposed scheme is validated on various fault and nonfault transients simulated on a test power system through MATLAB/Simulink. This protective scheme is farther validated throughout real-time assembled dSPACE DS 1104 control prototype hardware. The superiority of the proposed method is also demonstrated through comparative assessment results with few existing techniques. The overall results justify the merits of the proposed method for fast and accurate detection and classification of faults in such crucial TLs.
- Open Access
- 1 June 2023
- Published by KEAI Publishing in International Journal of Cognitive Computing in Engineering
- Vol. 4, 194-204
A Delay-Tolerant low-duty cycle scheme in wireless sensor networks for IoT applications
- 1 June 2023
- Published by KEAI Publishing in International Journal of Cognitive Computing in Engineering
- Vol. 4, 194-204
Open AccessA Delay-Tolerant low-duty cycle scheme in wireless sensor networks for IoT applications
- Open Access
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 72937-72948
A Data Mining Based Protection and Classification of Transients for Two-Core Symmetric Phase Angle Regulators
Several conventional and non-conventional transient conditions cause differential relays associated with Phase Angle Regulators to malfunction. For Two-core Symmetric Phase Angle Regulators, this article investigates the suitability of time and time-frequency feature-based estimators to differentiate internal faults from other transient conditions such as overexcitation, external faults with current transformer (CT) saturation, and magnetizing inrush. Subsequently, the faulty core unit (series or exciting) is located, and the transients are identified. Six well-known classifiers are trained on features extracted from one-cycle of post transient 3-phase differential currents filtered by an event detector. Maximum Relevance Minimum Redundancy, Random Forest, and exhaustive search with Decision Trees are used to select the relevant wavelet energy, time-domain, and wavelet coefficient features respectively. The fault detection scheme trained on XGBoost classifier with hyperparameters obtained from Bayesian Optimization gives an accuracy of 99.8%. The reliability of the proposed scheme is verified with varying tap positions, noise levels, and transformer ratings; and under different conditions like CT saturation, fault during magnetizing inrush, series core saturation, low current faults, and integration of wind energy. As a potential application, the methodology can be deployed to supervise microprocessor-based differential relays to improve the security and dependability of the protection system.
- 17 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 72937-72948
Open AccessA Data Mining Based Protection and Classification of Transients for Two-Core Symmetric Phase Angle Regulators
Several conventional and non-conventional transient conditions cause differential relays associated with Phase Angle Regulators to malfunction. For Two-core Symmetric Phase Angle Regulators, this article investigates the suitability of time and time-frequency feature-based estimators to differentiate internal faults from other transient conditions such as overexcitation, external faults with current transformer (CT) saturation, and magnetizing inrush. Subsequently, the faulty core unit (series or exciting) is located, and the transients are identified. Six well-known classifiers are trained on features extracted from one-cycle of post transient 3-phase differential currents filtered by an event detector. Maximum Relevance Minimum Redundancy, Random Forest, and exhaustive search with Decision Trees are used to select the relevant wavelet energy, time-domain, and wavelet coefficient features respectively. The fault detection scheme trained on XGBoost classifier with hyperparameters obtained from Bayesian Optimization gives an accuracy of 99.8%. The reliability of the proposed scheme is verified with varying tap positions, noise levels, and transformer ratings; and under different conditions like CT saturation, fault during magnetizing inrush, series core saturation, low current faults, and integration of wind energy. As a potential application, the methodology can be deployed to supervise microprocessor-based differential relays to improve the security and dependability of the protection system.
- Open Access
Discrimination of Internal Faults and Other Transients in an Interconnected System with Power Transformers and Phase Angle Regulators
This study solves the problem of accurate detection of internal faults and classification of transients in a 5-bus interconnected system for Phase Angle Regulators (PAR) and Power Transformers. The analysis prevents mal-operation of differential relays in case of transients other than faults which include magnetizing inrush, sympathetic inrush, external faults with CT saturation, capacitor switching, non-linear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of 3-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (Power Transformer, PAR series, or exciting unit) and identify the type of fault. In case a transient disturbance is detected, another GBC classifies them into the six transient disturbances. Five most relevant frequency and time domain features obtained using Information Gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy of 99.95%. The faulty transformer unit is located with a balanced accuracy of 99.5% and the different transient disturbances are identified with a balanced accuracy of 99.3%. Moreover, the reliability of the scheme is verified for different rating and connection of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two and three-winding transformer models for creating the internal faults including inter-turn and inter-winding faults.
Open AccessDiscrimination of Internal Faults and Other Transients in an Interconnected System with Power Transformers and Phase Angle Regulators
This study solves the problem of accurate detection of internal faults and classification of transients in a 5-bus interconnected system for Phase Angle Regulators (PAR) and Power Transformers. The analysis prevents mal-operation of differential relays in case of transients other than faults which include magnetizing inrush, sympathetic inrush, external faults with CT saturation, capacitor switching, non-linear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of 3-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (Power Transformer, PAR series, or exciting unit) and identify the type of fault. In case a transient disturbance is detected, another GBC classifies them into the six transient disturbances. Five most relevant frequency and time domain features obtained using Information Gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy of 99.95%. The faulty transformer unit is located with a balanced accuracy of 99.5% and the different transient disturbances are identified with a balanced accuracy of 99.3%. Moreover, the reliability of the scheme is verified for different rating and connection of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two and three-winding transformer models for creating the internal faults including inter-turn and inter-winding faults.
- 29 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 15 (3) , 3450-3461
Discrimination of Internal Faults and Other Transients in an Interconnected System With Power Transformers and Phase Angle Regulators
This article solves the problem of accurate detection of internal faults and classification of transients in a five-bus interconnected system for phase angle regulators (PARs) and power transformers (PTs). The analysis prevents mal-operation of differential relays in case of transients other than faults, which include magnetizing inrush, sympathetic inrush, external faults with current transformer (CT) saturation, capacitor switching, nonlinear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of three-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (PT, PAR series, or exciting unit) and identify the type of fault. In case, a transient disturbance is detected, another GBC classifies them into the six disturbances. Five most relevant frequency- and time-domain features obtained using information gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy ( $\bar{\eta }$ ) of 99.95%. The faulty transformer unit is located with $\bar{\eta }$ of 99.5% and the different transient disturbances are identified with $\bar{\eta }$ of 99.3%. Moreover, the reliability of the scheme is verified for different ratings and connections of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two- and three-winding transformer models for creating the internal faults including interturn and interwinding faults.- 29 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 15 (3) , 3450-3461
Discrimination of Internal Faults and Other Transients in an Interconnected System With Power Transformers and Phase Angle Regulators
This article solves the problem of accurate detection of internal faults and classification of transients in a five-bus interconnected system for phase angle regulators (PARs) and power transformers (PTs). The analysis prevents mal-operation of differential relays in case of transients other than faults, which include magnetizing inrush, sympathetic inrush, external faults with current transformer (CT) saturation, capacitor switching, nonlinear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of three-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (PT, PAR series, or exciting unit) and identify the type of fault. In case, a transient disturbance is detected, another GBC classifies them into the six disturbances. Five most relevant frequency- and time-domain features obtained using information gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy ( $\bar{\eta }$ ) of 99.95%. The faulty transformer unit is located with $\bar{\eta }$ of 99.5% and the different transient disturbances are identified with $\bar{\eta }$ of 99.3%. Moreover, the reliability of the scheme is verified for different ratings and connections of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two- and three-winding transformer models for creating the internal faults including interturn and interwinding faults.- Open Access
Detection and Classification of Internal Faults in Power Transformers using Tree-based Classifiers
This paper proposes a Decision Tree (DT) based detection and classification of internal faults in a power transformer. The faults are simulated in Power System Computer Aided Design (PSCAD)/ Electromagnetic Transients including DC (EMTDC) by varying the fault resistance, fault inception angle, and percentage of winding under fault. A series of features are extracted from the differential currents in phases a, b, and c belonging to the time, and frequency domains. Out of these, three features are selected to distinguish the internal faults from the magnetizing inrush and another three to classify faults in the primary and secondary of the transformer. DT, Random Forest (RF), and Gradient Boost (GB) classifiers are used to determine the fault types. The results show that DT detects faults with 100\% accuracy and the GB classifier performed the best among the three classifiers while classifying the internal faults.
Open AccessDetection and Classification of Internal Faults in Power Transformers using Tree-based Classifiers
This paper proposes a Decision Tree (DT) based detection and classification of internal faults in a power transformer. The faults are simulated in Power System Computer Aided Design (PSCAD)/ Electromagnetic Transients including DC (EMTDC) by varying the fault resistance, fault inception angle, and percentage of winding under fault. A series of features are extracted from the differential currents in phases a, b, and c belonging to the time, and frequency domains. Out of these, three features are selected to distinguish the internal faults from the magnetizing inrush and another three to classify faults in the primary and secondary of the transformer. DT, Random Forest (RF), and Gradient Boost (GB) classifiers are used to determine the fault types. The results show that DT detects faults with 100\% accuracy and the GB classifier performed the best among the three classifiers while classifying the internal faults.