Samita Rani Pani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Samita Rani Pani has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Pallav Kumar Bera
School of Applied Science and Engineering Western, Kentucky University, Bowling Green, Kentucky, USA
2 shared publications - Geetanjali Dei
School of Electrical Engineering, KIIT Deemed to be University,India
1 shared publication - Imen Ben Hamida
Laboratiry of Automatic, Electrical Systems and Environment (LAS2E), University of Monastir, ENIM, TUNISIA
1 shared publication - Kaushik Paul
Department of Electrical Engineering, BIT Sindri, Dhanbad 828123, India
1 shared publication - Majdi Mansouri
Sultan Qaboos University
1 shared publication - Om Parkash Malik
University of Calgary, Canada
1 shared publication
Latest Publications
- Open Access
- 8 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Intelligent Detection of High Impedance Faults in Microgrid Distribution Lines Using Optimized Machine Learning Models
This paper presents a data-driven protection scheme for high impedance fault (HIF) classification in microgrids. Conventional overcurrent protection often lacks the sensitivity to detect HIFs because of their low current magnitude and nonlinear characteristics. To address these limitations, we investigate an approach based on multiple machine learning (ML) classifier models for distribution line fault diagnosis. The proposed technique trains ML classifiers directly on raw three-phase differential current signals, allowing the models to autonomously learn patterns without manual feature extraction. The classifiers are optimized through a grid-search procedure and evaluated using a PSCAD/EMTDC model of a 5-bus AC microgrid test system with distributed generations (DGs) operating in both grid-connected and islanded modes. The generated dataset includes healthy conditions, internal faults (with/without HIF), and external faults with current transformer (CT) saturation. Nine ML models are assessed using accuracy, precision, recall, F1-score, receiver operating characteristic (ROC) analysis, computational cost, and noise sensitivity tests. The results indicate that the feedforward neural network (FFNN), random forest (RF), and stochastic gradient descent (SGD) classifiers exhibit robust and consistent classification performance on the test set. Significantly, even when using raw input data, the proposed methodology effectively discriminates subtle HIF signatures from other transient events and CT saturation conditions. These findings highlight the potential of optimized ML models, particularly FFNN and RF classifiers, to provide accurate and robust support for real-time microgrid protection.
- 8 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. PP, 1
Open AccessIntelligent Detection of High Impedance Faults in Microgrid Distribution Lines Using Optimized Machine Learning Models
This paper presents a data-driven protection scheme for high impedance fault (HIF) classification in microgrids. Conventional overcurrent protection often lacks the sensitivity to detect HIFs because of their low current magnitude and nonlinear characteristics. To address these limitations, we investigate an approach based on multiple machine learning (ML) classifier models for distribution line fault diagnosis. The proposed technique trains ML classifiers directly on raw three-phase differential current signals, allowing the models to autonomously learn patterns without manual feature extraction. The classifiers are optimized through a grid-search procedure and evaluated using a PSCAD/EMTDC model of a 5-bus AC microgrid test system with distributed generations (DGs) operating in both grid-connected and islanded modes. The generated dataset includes healthy conditions, internal faults (with/without HIF), and external faults with current transformer (CT) saturation. Nine ML models are assessed using accuracy, precision, recall, F1-score, receiver operating characteristic (ROC) analysis, computational cost, and noise sensitivity tests. The results indicate that the feedforward neural network (FFNN), random forest (RF), and stochastic gradient descent (SGD) classifiers exhibit robust and consistent classification performance on the test set. Significantly, even when using raw input data, the proposed methodology effectively discriminates subtle HIF signatures from other transient events and CT saturation conditions. These findings highlight the potential of optimized ML models, particularly FFNN and RF classifiers, to provide accurate and robust support for real-time microgrid protection.
- Open Access
- 31 January 2024
- Published by Frontiers Media SA in Frontiers in Smart Grids
- Vol. 3, 1338774
Identification of harmonic sources in smart grid using systematic feature extraction from non-active powers
The paper introduces a novel method for identifying the location of harmonic-generating sources in smartgrids. The method utilizes a Dual-Tree Complex Wavelet Transform (DTCWT) of voltage and current signals measured at a specific point in the network. By applying DTCWT Transform, the signals are decomposed, and three non-active power quantities are extracted to represent the harmonic components within the system exclusively. These chosen non-active power quantities serve as indicators of the presence of harmonics in the system. Through analysis and comparison of these quantities, the method enables determining the precise location of the dominant harmonic generating source. This information is valuable for effectively addressing and mitigating harmonic issues in the network. Leveraging DTCWT and focusing on non-active power quantities provides a valuable tool for power system engineers and operators to diagnose and mitigate harmonic issues, ultimately improving power quality and system performance. This study presents a new feature extraction method to compute Non-active power quantities based on DTCWT due to its shift-invariant property.
- 31 January 2024
- Published by Frontiers Media SA in Frontiers in Smart Grids
- Vol. 3, 1338774
Open AccessIdentification of harmonic sources in smart grid using systematic feature extraction from non-active powers
The paper introduces a novel method for identifying the location of harmonic-generating sources in smartgrids. The method utilizes a Dual-Tree Complex Wavelet Transform (DTCWT) of voltage and current signals measured at a specific point in the network. By applying DTCWT Transform, the signals are decomposed, and three non-active power quantities are extracted to represent the harmonic components within the system exclusively. These chosen non-active power quantities serve as indicators of the presence of harmonics in the system. Through analysis and comparison of these quantities, the method enables determining the precise location of the dominant harmonic generating source. This information is valuable for effectively addressing and mitigating harmonic issues in the network. Leveraging DTCWT and focusing on non-active power quantities provides a valuable tool for power system engineers and operators to diagnose and mitigate harmonic issues, ultimately improving power quality and system performance. This study presents a new feature extraction method to compute Non-active power quantities based on DTCWT due to its shift-invariant property.
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 71-82
Autoregressive Coefficients Based Intelligent Protection of Transmission Lines Connected to Type-3 Wind Farms
Protective relays can mal-operate for transmission lines connected to doubly fed induction generator (DFIG) based large capacity wind farms (WFs). The performance of distance relays protecting such lines is investigated and a statistical model based intelligent protection of the area between the grid and the WF is proposed in this article. The suggested method employs an adaptive fuzzy inference system to detect faults based on autoregressive (AR) coefficients of the 3-phase currents selected using minimum redundancy maximum relevance algorithm. Deep learning networks are used to supervise the detection of faults, their subsequent localization, and classification. The effectiveness of the scheme is evaluated on IEEE 9-bus and IEEE 39-bus systems with varying fault resistances, fault inception times, locations, fault types, wind speeds, and transformer connections. Further, the impact of factors like the presence of type-4 WFs, double circuit lines, WF capacity, grid strength, FACTs devices, reclosing on permanent faults, power swings, fault during power swings, voltage instability, load encroachment, high impedance faults, evolving and cross-country faults, close-in and remote-end faults, CT saturation, sampling rate, data window size, synchronization error, noise, and semi-supervised learning are considered while validating the proposed scheme. The results show the efficacy of the suggested method in dealing with various system conditions and configurations while protecting the transmission lines that are connected to WFs.
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 71-82
Autoregressive Coefficients Based Intelligent Protection of Transmission Lines Connected to Type-3 Wind Farms
Protective relays can mal-operate for transmission lines connected to doubly fed induction generator (DFIG) based large capacity wind farms (WFs). The performance of distance relays protecting such lines is investigated and a statistical model based intelligent protection of the area between the grid and the WF is proposed in this article. The suggested method employs an adaptive fuzzy inference system to detect faults based on autoregressive (AR) coefficients of the 3-phase currents selected using minimum redundancy maximum relevance algorithm. Deep learning networks are used to supervise the detection of faults, their subsequent localization, and classification. The effectiveness of the scheme is evaluated on IEEE 9-bus and IEEE 39-bus systems with varying fault resistances, fault inception times, locations, fault types, wind speeds, and transformer connections. Further, the impact of factors like the presence of type-4 WFs, double circuit lines, WF capacity, grid strength, FACTs devices, reclosing on permanent faults, power swings, fault during power swings, voltage instability, load encroachment, high impedance faults, evolving and cross-country faults, close-in and remote-end faults, CT saturation, sampling rate, data window size, synchronization error, noise, and semi-supervised learning are considered while validating the proposed scheme. The results show the efficacy of the suggested method in dealing with various system conditions and configurations while protecting the transmission lines that are connected to WFs.