Vajendra Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vajendra Kumar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Pallav Kumar Bera
School of Applied Science and Engineering Western, Kentucky University, Bowling Green, Kentucky, USA
4 shared publications - Can Isik
Syracuse University, Syracuse, NY 13244, USA
2 shared publications - Samita Rani Pani
School of Electrical Engineering VSSUT KIIT Deemed to be University Burla India
2 shared publications - Om Parkash Malik
University of Calgary, Canada
1 shared publication Pallav Kumar Bera
School of Engr. & Computer Science University of Evansville Indiana USA
1 shared publication- Samita Rani Pani
School of Electrical Engineering, Kalinga Institute of Industrial Technology (KIIT), Bhubaneswar, Odisha, India
1 shared publication
Latest Publications
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 71-82
Autoregressive Coefficients Based Intelligent Protection of Transmission Lines Connected to Type-3 Wind Farms
Protective relays can mal-operate for transmission lines connected to doubly fed induction generator (DFIG) based large capacity wind farms (WFs). The performance of distance relays protecting such lines is investigated and a statistical model based intelligent protection of the area between the grid and the WF is proposed in this article. The suggested method employs an adaptive fuzzy inference system to detect faults based on autoregressive (AR) coefficients of the 3-phase currents selected using minimum redundancy maximum relevance algorithm. Deep learning networks are used to supervise the detection of faults, their subsequent localization, and classification. The effectiveness of the scheme is evaluated on IEEE 9-bus and IEEE 39-bus systems with varying fault resistances, fault inception times, locations, fault types, wind speeds, and transformer connections. Further, the impact of factors like the presence of type-4 WFs, double circuit lines, WF capacity, grid strength, FACTs devices, reclosing on permanent faults, power swings, fault during power swings, voltage instability, load encroachment, high impedance faults, evolving and cross-country faults, close-in and remote-end faults, CT saturation, sampling rate, data window size, synchronization error, noise, and semi-supervised learning are considered while validating the proposed scheme. The results show the efficacy of the suggested method in dealing with various system conditions and configurations while protecting the transmission lines that are connected to WFs.
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 71-82
Autoregressive Coefficients Based Intelligent Protection of Transmission Lines Connected to Type-3 Wind Farms
Protective relays can mal-operate for transmission lines connected to doubly fed induction generator (DFIG) based large capacity wind farms (WFs). The performance of distance relays protecting such lines is investigated and a statistical model based intelligent protection of the area between the grid and the WF is proposed in this article. The suggested method employs an adaptive fuzzy inference system to detect faults based on autoregressive (AR) coefficients of the 3-phase currents selected using minimum redundancy maximum relevance algorithm. Deep learning networks are used to supervise the detection of faults, their subsequent localization, and classification. The effectiveness of the scheme is evaluated on IEEE 9-bus and IEEE 39-bus systems with varying fault resistances, fault inception times, locations, fault types, wind speeds, and transformer connections. Further, the impact of factors like the presence of type-4 WFs, double circuit lines, WF capacity, grid strength, FACTs devices, reclosing on permanent faults, power swings, fault during power swings, voltage instability, load encroachment, high impedance faults, evolving and cross-country faults, close-in and remote-end faults, CT saturation, sampling rate, data window size, synchronization error, noise, and semi-supervised learning are considered while validating the proposed scheme. The results show the efficacy of the suggested method in dealing with various system conditions and configurations while protecting the transmission lines that are connected to WFs.
- Open Access
Detection of High Impedance Faults in Microgrids using Machine Learning
This article presents differential protection of the distribution line connecting a wind farm in a microgrid. Machine Learning (ML) based models are built using differential features extracted from currents at both ends of the line to assist in relaying decisions. Wavelet coefficients obtained after feature selection from an extensive list of features are used to train the classifiers. Internal faults are distinguished from external faults with CT saturation. The internal faults include the high impedance faults (HIFs) which have very low currents and test the dependability of the conventional relays. The faults are simulated in a 5-bus system in PSCAD/EMTDC. The results show that ML-based models can effectively distinguish faults and other transients and help maintain security and dependability of the microgrid operation.
Open AccessDetection of High Impedance Faults in Microgrids using Machine Learning
This article presents differential protection of the distribution line connecting a wind farm in a microgrid. Machine Learning (ML) based models are built using differential features extracted from currents at both ends of the line to assist in relaying decisions. Wavelet coefficients obtained after feature selection from an extensive list of features are used to train the classifiers. Internal faults are distinguished from external faults with CT saturation. The internal faults include the high impedance faults (HIFs) which have very low currents and test the dependability of the conventional relays. The faults are simulated in a 5-bus system in PSCAD/EMTDC. The results show that ML-based models can effectively distinguish faults and other transients and help maintain security and dependability of the microgrid operation.
- Open Access
Discrimination of Internal Faults and Other Transients in an Interconnected System with Power Transformers and Phase Angle Regulators
This study solves the problem of accurate detection of internal faults and classification of transients in a 5-bus interconnected system for Phase Angle Regulators (PAR) and Power Transformers. The analysis prevents mal-operation of differential relays in case of transients other than faults which include magnetizing inrush, sympathetic inrush, external faults with CT saturation, capacitor switching, non-linear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of 3-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (Power Transformer, PAR series, or exciting unit) and identify the type of fault. In case a transient disturbance is detected, another GBC classifies them into the six transient disturbances. Five most relevant frequency and time domain features obtained using Information Gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy of 99.95%. The faulty transformer unit is located with a balanced accuracy of 99.5% and the different transient disturbances are identified with a balanced accuracy of 99.3%. Moreover, the reliability of the scheme is verified for different rating and connection of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two and three-winding transformer models for creating the internal faults including inter-turn and inter-winding faults.
Open AccessDiscrimination of Internal Faults and Other Transients in an Interconnected System with Power Transformers and Phase Angle Regulators
This study solves the problem of accurate detection of internal faults and classification of transients in a 5-bus interconnected system for Phase Angle Regulators (PAR) and Power Transformers. The analysis prevents mal-operation of differential relays in case of transients other than faults which include magnetizing inrush, sympathetic inrush, external faults with CT saturation, capacitor switching, non-linear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of 3-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (Power Transformer, PAR series, or exciting unit) and identify the type of fault. In case a transient disturbance is detected, another GBC classifies them into the six transient disturbances. Five most relevant frequency and time domain features obtained using Information Gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy of 99.95%. The faulty transformer unit is located with a balanced accuracy of 99.5% and the different transient disturbances are identified with a balanced accuracy of 99.3%. Moreover, the reliability of the scheme is verified for different rating and connection of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two and three-winding transformer models for creating the internal faults including inter-turn and inter-winding faults.
- 29 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 15 (3) , 3450-3461
Discrimination of Internal Faults and Other Transients in an Interconnected System With Power Transformers and Phase Angle Regulators
This article solves the problem of accurate detection of internal faults and classification of transients in a five-bus interconnected system for phase angle regulators (PARs) and power transformers (PTs). The analysis prevents mal-operation of differential relays in case of transients other than faults, which include magnetizing inrush, sympathetic inrush, external faults with current transformer (CT) saturation, capacitor switching, nonlinear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of three-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (PT, PAR series, or exciting unit) and identify the type of fault. In case, a transient disturbance is detected, another GBC classifies them into the six disturbances. Five most relevant frequency- and time-domain features obtained using information gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy ( $\bar{\eta }$ ) of 99.95%. The faulty transformer unit is located with $\bar{\eta }$ of 99.5% and the different transient disturbances are identified with $\bar{\eta }$ of 99.3%. Moreover, the reliability of the scheme is verified for different ratings and connections of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two- and three-winding transformer models for creating the internal faults including interturn and interwinding faults.- 29 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 15 (3) , 3450-3461
Discrimination of Internal Faults and Other Transients in an Interconnected System With Power Transformers and Phase Angle Regulators
This article solves the problem of accurate detection of internal faults and classification of transients in a five-bus interconnected system for phase angle regulators (PARs) and power transformers (PTs). The analysis prevents mal-operation of differential relays in case of transients other than faults, which include magnetizing inrush, sympathetic inrush, external faults with current transformer (CT) saturation, capacitor switching, nonlinear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of three-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (PT, PAR series, or exciting unit) and identify the type of fault. In case, a transient disturbance is detected, another GBC classifies them into the six disturbances. Five most relevant frequency- and time-domain features obtained using information gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy ( $\bar{\eta }$ ) of 99.95%. The faulty transformer unit is located with $\bar{\eta }$ of 99.5% and the different transient disturbances are identified with $\bar{\eta }$ of 99.3%. Moreover, the reliability of the scheme is verified for different ratings and connections of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two- and three-winding transformer models for creating the internal faults including interturn and interwinding faults.- Open Access
Detection and Classification of Internal Faults in Power Transformers using Tree-based Classifiers
This paper proposes a Decision Tree (DT) based detection and classification of internal faults in a power transformer. The faults are simulated in Power System Computer Aided Design (PSCAD)/ Electromagnetic Transients including DC (EMTDC) by varying the fault resistance, fault inception angle, and percentage of winding under fault. A series of features are extracted from the differential currents in phases a, b, and c belonging to the time, and frequency domains. Out of these, three features are selected to distinguish the internal faults from the magnetizing inrush and another three to classify faults in the primary and secondary of the transformer. DT, Random Forest (RF), and Gradient Boost (GB) classifiers are used to determine the fault types. The results show that DT detects faults with 100\% accuracy and the GB classifier performed the best among the three classifiers while classifying the internal faults.
Open AccessDetection and Classification of Internal Faults in Power Transformers using Tree-based Classifiers
This paper proposes a Decision Tree (DT) based detection and classification of internal faults in a power transformer. The faults are simulated in Power System Computer Aided Design (PSCAD)/ Electromagnetic Transients including DC (EMTDC) by varying the fault resistance, fault inception angle, and percentage of winding under fault. A series of features are extracted from the differential currents in phases a, b, and c belonging to the time, and frequency domains. Out of these, three features are selected to distinguish the internal faults from the magnetizing inrush and another three to classify faults in the primary and secondary of the transformer. DT, Random Forest (RF), and Gradient Boost (GB) classifiers are used to determine the fault types. The results show that DT detects faults with 100\% accuracy and the GB classifier performed the best among the three classifiers while classifying the internal faults.