Tobias Menden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tobias Menden has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Steffen Leonhardt
RWTH Aachen University
5 shared publications - Marian Walter
Institute for Medical Information Technology, RWTH Aachen University,Aachen,Germany
3 shared publications Jascha Matuszczyk
Shared first authorship Aachen , Germany
2 shared publicationsMarian Walter
Medical Information Technology, RWTH Aachen University , Pauwelsstr. 20 , Aachen , Germany
2 shared publicationsAlec T Stevenson
QinetiQ, Farnborough
1 shared publication- Caroline J. Jolley
Centre for Human and Applied Physiological Sciences, Faculty of Life Sciences & Medicine, King’s College London, London, UK
1 shared publication
Latest Publications
- 1 September 2021
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (9) , 094001
Dynamic lung behavior under high G acceleration monitored with electrical impedance tomography
Objective . During launch and atmospheric re-entry in suborbital space flights, astronauts are exposed to high G-acceleration. These acceleration levels influence gas exchange inside the lung and can potentially lead to hypoxaemia. The distribution of air inside the lung can be monitored by electrical impedance tomography. This imaging technique might reveal how high gravitational forces affect the dynamic behavior of ventilation and impair gas exchange resulting in hypoxaemia. Approach . We performed a trial in a long-arm centrifuge with ten participants lying supine while being exposed to +2, +4 and +6 G x (chest-to-back acceleration) to study the magnitude of accelerations experienced during suborbital spaceflight. Main results . First, the tomographic images revealed that the dorsal region of the lung emptied faster than the ventral region. Second, the ventilated area shifted from dorsal to ventral. Consequently, alveolar pressure in the dorsal area reached the pressure of the upper airways before the ventral area emptied completely. Finally, the upper airways collapsed and the end-expiratory volume increased. This resulted in ventral gas trapping with restricted gas exchange. Significance . At +4 G x , changes in ventilation distribution varied considerably between subjects, potentially due to variation in individual physical conditions. However, at +6 G x all participants were affected similarly and the influence of high gravitational conditions was pronounced.
- 1 September 2021
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (9) , 094001
Dynamic lung behavior under high G acceleration monitored with electrical impedance tomography
Objective . During launch and atmospheric re-entry in suborbital space flights, astronauts are exposed to high G-acceleration. These acceleration levels influence gas exchange inside the lung and can potentially lead to hypoxaemia. The distribution of air inside the lung can be monitored by electrical impedance tomography. This imaging technique might reveal how high gravitational forces affect the dynamic behavior of ventilation and impair gas exchange resulting in hypoxaemia. Approach . We performed a trial in a long-arm centrifuge with ten participants lying supine while being exposed to +2, +4 and +6 G x (chest-to-back acceleration) to study the magnitude of accelerations experienced during suborbital spaceflight. Main results . First, the tomographic images revealed that the dorsal region of the lung emptied faster than the ventral region. Second, the ventilated area shifted from dorsal to ventral. Consequently, alveolar pressure in the dorsal area reached the pressure of the upper airways before the ventral area emptied completely. Finally, the upper airways collapsed and the end-expiratory volume increased. This resulted in ventral gas trapping with restricted gas exchange. Significance . At +4 G x , changes in ventilation distribution varied considerably between subjects, potentially due to variation in individual physical conditions. However, at +6 G x all participants were affected similarly and the influence of high gravitational conditions was pronounced.
- 1 June 2021
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (6) , 064002
Multi-channel bioimpedance spectroscopy based on orthogonal baseband shifting
Objective . Multi-channel bioimpedance spectroscopy (BIS) systems typically sample each channel’s impedance sequentially using multiplexers and a single analog-to-digital converter. These systems may lose their real-time capability with an increasing number of channels, especially for low excitation frequencies. We propose a new method, called orthogonal baseband shifting (OBS), for high-speed parallel BIS data acquisition at multiple excitation frequencies with low hardware and computational effort. Approach . Similar to orthogonal frequency-division multiplexing, used for digital data transmission, OBS systems use channel-specific orthogonal carrier frequencies to modulate the voltage response of the tissue. Given a suitable choice of carrier frequencies, the modulated signals of all channels sum up without loss of information and cross-talk. The fast Fourier transform (FFT) of the summed signal reveals a spectrum of non-overlapping, interleaved BIS data from which the corresponding BIS data of each channel can be calculated. Main results . In simulations, the system design requires a minimum signal-to-noise ratio of 30 dB to achieve amplitude errors below 1% and phase errors below 0.8°. The hardware realization, called ‘AixBIS’, has been evaluated for impedance measurements between 0.1 and 10 Ω with multi-frequency excitations between 45 and 180 kHz. The impedance values acquired had an averaged precision of 3.67 mΩ, which is only 0.65‰ in relation to the measured impedance. The phase had a mean precision of 0.46°. Moreover, in vitro measurements achieved 140 full spectrum acquisitions per second. The impedance change measured in a silicone heart phantom showed a high correlation of 0.83 with the ventricles volume change (flow). Significance . The proposed method enables very fast impedance acquisition of all channels. A complete measurement is performed in the time of a single FFT acquisition, which is equal to the resolution bandwidth of the FFT. In addition, portable and low-power multi-channel BIS devices profit from highly reduced hardware effort. The outstanding performance of OBS measurements with the AixBIS system have the potential for in vivo BIS measurements in real-time.
- 1 June 2021
- Published by IOP Publishing in Physiological Measurement
- Vol. 42 (6) , 064002
Multi-channel bioimpedance spectroscopy based on orthogonal baseband shifting
Objective . Multi-channel bioimpedance spectroscopy (BIS) systems typically sample each channel’s impedance sequentially using multiplexers and a single analog-to-digital converter. These systems may lose their real-time capability with an increasing number of channels, especially for low excitation frequencies. We propose a new method, called orthogonal baseband shifting (OBS), for high-speed parallel BIS data acquisition at multiple excitation frequencies with low hardware and computational effort. Approach . Similar to orthogonal frequency-division multiplexing, used for digital data transmission, OBS systems use channel-specific orthogonal carrier frequencies to modulate the voltage response of the tissue. Given a suitable choice of carrier frequencies, the modulated signals of all channels sum up without loss of information and cross-talk. The fast Fourier transform (FFT) of the summed signal reveals a spectrum of non-overlapping, interleaved BIS data from which the corresponding BIS data of each channel can be calculated. Main results . In simulations, the system design requires a minimum signal-to-noise ratio of 30 dB to achieve amplitude errors below 1% and phase errors below 0.8°. The hardware realization, called ‘AixBIS’, has been evaluated for impedance measurements between 0.1 and 10 Ω with multi-frequency excitations between 45 and 180 kHz. The impedance values acquired had an averaged precision of 3.67 mΩ, which is only 0.65‰ in relation to the measured impedance. The phase had a mean precision of 0.46°. Moreover, in vitro measurements achieved 140 full spectrum acquisitions per second. The impedance change measured in a silicone heart phantom showed a high correlation of 0.83 with the ventricles volume change (flow). Significance . The proposed method enables very fast impedance acquisition of all channels. A complete measurement is performed in the time of a single FFT acquisition, which is equal to the resolution bandwidth of the FFT. In addition, portable and low-power multi-channel BIS devices profit from highly reduced hardware effort. The outstanding performance of OBS measurements with the AixBIS system have the potential for in vivo BIS measurements in real-time.
- Open Access
- 1 January 2021
- Published by Walter de Gruyter GmbH in Journal of Electrical Bioimpedance
- Vol. 12 (1) , 135-146
Bandwidth and Common Mode Optimization for Current and Voltage Sources in Bioimpedance Spectroscopy
Bioimpedance measurements use current or voltage sources to inject an excitation signal into the body. These sources require a high bandwidth, typically from 1 kHz to 1 MHz. Besides a low common mode, current limitation is necessary for patient safety. In this paper, we compare a symmetric enhanced Howland current source (EHCS) and a symmetric voltage source (VS) based on a non-inverting amplifier between 1 kHz and 1 MHz. A common mode reduction circuit has been implemented in both sources. The bandwidth of each source was optimized in simulations and achieved a stable output impedance over the whole frequency range. In laboratory measurements, the output impedance of the EHCS had its -3 dB point at 400 kHz. In contrast, the VS reached the +3 dB point at 600 kHz. On average over the observed frequency range, the active common mode compensation achieved a common mode rejection of -57.7 dB and -71.8 dB for the EHCS and VS, respectively. Our modifications to classical EHCS and VS circuits achieved a low common mode signal between 1 kHz and 1 MHz without the addition of complex circuitry, like general impedance converters. As a conclusion we found VSs to be superior to EHCSs for bioimpedance spectroscopy due to the higher bandwidth performance. However, this only applies if the injected current of the VS can be measured.
- 1 January 2021
- Published by Walter de Gruyter GmbH in Journal of Electrical Bioimpedance
- Vol. 12 (1) , 135-146
Open AccessBandwidth and Common Mode Optimization for Current and Voltage Sources in Bioimpedance Spectroscopy
Bioimpedance measurements use current or voltage sources to inject an excitation signal into the body. These sources require a high bandwidth, typically from 1 kHz to 1 MHz. Besides a low common mode, current limitation is necessary for patient safety. In this paper, we compare a symmetric enhanced Howland current source (EHCS) and a symmetric voltage source (VS) based on a non-inverting amplifier between 1 kHz and 1 MHz. A common mode reduction circuit has been implemented in both sources. The bandwidth of each source was optimized in simulations and achieved a stable output impedance over the whole frequency range. In laboratory measurements, the output impedance of the EHCS had its -3 dB point at 400 kHz. In contrast, the VS reached the +3 dB point at 600 kHz. On average over the observed frequency range, the active common mode compensation achieved a common mode rejection of -57.7 dB and -71.8 dB for the EHCS and VS, respectively. Our modifications to classical EHCS and VS circuits achieved a low common mode signal between 1 kHz and 1 MHz without the addition of complex circuitry, like general impedance converters. As a conclusion we found VSs to be superior to EHCSs for bioimpedance spectroscopy due to the higher bandwidth performance. However, this only applies if the injected current of the VS can be measured.
- 5 February 2020
- Published by Springer Nature in IFMBE Proceedings
- p. 11-17
Influence of Measurement Pattern on RAW-data in Electrical Impedance Tomography
- 5 February 2020
- Published by Springer Nature in IFMBE Proceedings
- p. 11-17
Influence of Measurement Pattern on RAW-data in Electrical Impedance Tomography
- 1 March 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (3) , 034008
Reconstruction algorithm for frequency-differential EIT using absolute values
Objective : Tissues in the body differ by their frequency-dependent conductivity. Frequency-differential electrical impedance tomography (fdEIT) is a promising technique to reconstruct the distribution of tissue inside the body by injecting current at two frequencies and measuring the resulting surface-potential. Approach : The Gauss–Newton method is one way to map the surface measurements to a conductivity image. Usually, the minimization function contains only weighted differential measurement data and a regularization. This traditional method is extended by absolute measurement data to improve fdEIT reconstruction results. The key challenge of unknown torso geometries and electrode displacement has been addressed for the reconstruction of different lung pathologies. Main results : The frequency-dependent conductivity of the background was reconstructed precisely and a contrast between organs was achieved. The algorithm shows good performance compared to GREIT and the traditional Gauss–Newton method with respect to the figures of merit of GREIT. Significance : The reconstruction is robust in the presence of noise. One application of the algorithm might be the detection and monitoring of lung diseases like edema or atelectasis.
- 1 March 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (3) , 034008
Reconstruction algorithm for frequency-differential EIT using absolute values
Objective : Tissues in the body differ by their frequency-dependent conductivity. Frequency-differential electrical impedance tomography (fdEIT) is a promising technique to reconstruct the distribution of tissue inside the body by injecting current at two frequencies and measuring the resulting surface-potential. Approach : The Gauss–Newton method is one way to map the surface measurements to a conductivity image. Usually, the minimization function contains only weighted differential measurement data and a regularization. This traditional method is extended by absolute measurement data to improve fdEIT reconstruction results. The key challenge of unknown torso geometries and electrode displacement has been addressed for the reconstruction of different lung pathologies. Main results : The frequency-dependent conductivity of the background was reconstructed precisely and a contrast between organs was achieved. The algorithm shows good performance compared to GREIT and the traditional Gauss–Newton method with respect to the figures of merit of GREIT. Significance : The reconstruction is robust in the presence of noise. One application of the algorithm might be the detection and monitoring of lung diseases like edema or atelectasis.