Akanksha Mishra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Akanksha Mishra has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dasika Nagesh Kumar
Department of Civil Engineering, Indian Institute of Science, Bengaluru, India
12 shared publications Gundavarapu Venkata Nagesh Kumar
GITAM University
2 shared publications- Bathina Venkateswara Rao
V. R. Siddhartha Engineering College
1 shared publication - Deepak Chowdary Duvvada
Vignan's Institute of Information Technology, Andhra Pradesh, INDIA
1 shared publication G. V. Nagesh Kumar
1 shared publicationS. ChandraSekhar Beera
Vignan's Institute of Engineering for Women
1 shared publication
Latest Publications
- Open Access
- 28 August 2024
- Published by Springer Nature in Research Square
Reduction of Thermal Loading on ACSR Transmission Lines by Optimization of Integrated Power System
Maximum utilization of the ACSR conductors, renewable and optimal utilization of the non-renewable resources for meeting the energy requirements is the norm of the present Industrial world. Availability of quality, undisrupted and reliable power at affordable prizes to the customers is the objective of the research. In this paper, a multi- objective optimal power flow of the power system in the presence of Interline Power Flow Controller is proposed for an integrated transmission system. The objective function includes minimization of power loss, negative security margin (NSM), voltage deviation, and negative social welfare (NSW). Lessening of loss and NSW ensures a drop in per-unit charge of energy leading to a greater customer satisfaction. The proposition has been applied on an IEEE 30 bus system. A 24-hour loading of the transmission system has been used to study the reliability of the proposed system. This gives an insight into the actual loading scenario of the power system. The Moth Flame Optimization Algorithm has been used for the optimization of objective function. The results obtained have been presented, compared and analysed in detail.
- 28 August 2024
- Published by Springer Nature in Research Square
Open AccessReduction of Thermal Loading on ACSR Transmission Lines by Optimization of Integrated Power System
Maximum utilization of the ACSR conductors, renewable and optimal utilization of the non-renewable resources for meeting the energy requirements is the norm of the present Industrial world. Availability of quality, undisrupted and reliable power at affordable prizes to the customers is the objective of the research. In this paper, a multi- objective optimal power flow of the power system in the presence of Interline Power Flow Controller is proposed for an integrated transmission system. The objective function includes minimization of power loss, negative security margin (NSM), voltage deviation, and negative social welfare (NSW). Lessening of loss and NSW ensures a drop in per-unit charge of energy leading to a greater customer satisfaction. The proposition has been applied on an IEEE 30 bus system. A 24-hour loading of the transmission system has been used to study the reliability of the proposed system. This gives an insight into the actual loading scenario of the power system. The Moth Flame Optimization Algorithm has been used for the optimization of objective function. The results obtained have been presented, compared and analysed in detail.
- Open Access
- 1 May 2017
- Published by Springer Nature in Journal of Electrical Systems and Information Technology
- Vol. 4 (1) , 198-212
Congestion management of deregulated power systems by optimal setting of Interline Power Flow Controller using Gravitational Search algorithm
- 1 May 2017
- Published by Springer Nature in Journal of Electrical Systems and Information Technology
- Vol. 4 (1) , 198-212
Open AccessCongestion management of deregulated power systems by optimal setting of Interline Power Flow Controller using Gravitational Search algorithm
- 20 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Composite severity contingency distribution index based contingency management of power system
Secured and uninterrupted operation of the power systems has become a great challenge. The load on the practical power systems vary through the day, month and year. Thus making the task of the power system engineers much more complicated. In this paper, a novel index, namely, composite severity contingency distribution index (CSCDI) has been proposed in order to find the severe-most line of the system under contingency condition in real time scenario. Contingency analysis for each hour load of the IEEE 30 bus system has been performed. CSCDI has been calculated for each line of the system and the result obtained indicates the stress on the lines due to contingency for varied load throughout the day. An IPFC has been optimally placed to improve the post-contingency condition. The device has further been tuned for a multi-objective function using differential evolution algorithm. The results obtained have been presented and analyzed to emphasize on the advantages of IPFC for post-contingency management in a real time framework.
- 20 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Composite severity contingency distribution index based contingency management of power system
Secured and uninterrupted operation of the power systems has become a great challenge. The load on the practical power systems vary through the day, month and year. Thus making the task of the power system engineers much more complicated. In this paper, a novel index, namely, composite severity contingency distribution index (CSCDI) has been proposed in order to find the severe-most line of the system under contingency condition in real time scenario. Contingency analysis for each hour load of the IEEE 30 bus system has been performed. CSCDI has been calculated for each line of the system and the result obtained indicates the stress on the lines due to contingency for varied load throughout the day. An IPFC has been optimally placed to improve the post-contingency condition. The device has further been tuned for a multi-objective function using differential evolution algorithm. The results obtained have been presented and analyzed to emphasize on the advantages of IPFC for post-contingency management in a real time framework.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 8 (3) , 257
A risk of severity based scheme for optimal placement of interline power flow controller using composite index
Due to massive increase in the power transactions due to restructuring, the stress in transmission lines has increased largely and severity assessment is very essential. Contingency assessment of a power system predicts the effect of outages in transmission lines and generator units. In this paper, contingency ranking of the lines has been done using composite severity index. A risk-based strategy has been adopted for the placement of interline power flow converter (IPFC). From the list of the severe lines obtained, IPFC is placed on the line which has highest possibility of severity during the occurrence for different outages. To verify the proposed methodology, it is implemented on IEEE 30 and Indian Utility 62 bus systems. The load on the bus with highest load is further increased gradually up to the critical value and the results have been presented and analysed to ascertain the effectiveness of IPFC for contingency management.
- 1 January 2017
- Published by Inderscience Publishers in International Journal of Power and Energy Conversion
- Vol. 8 (3) , 257
A risk of severity based scheme for optimal placement of interline power flow controller using composite index
Due to massive increase in the power transactions due to restructuring, the stress in transmission lines has increased largely and severity assessment is very essential. Contingency assessment of a power system predicts the effect of outages in transmission lines and generator units. In this paper, contingency ranking of the lines has been done using composite severity index. A risk-based strategy has been adopted for the placement of interline power flow converter (IPFC). From the list of the severe lines obtained, IPFC is placed on the line which has highest possibility of severity during the occurrence for different outages. To verify the proposed methodology, it is implemented on IEEE 30 and Indian Utility 62 bus systems. The load on the bus with highest load is further increased gradually up to the critical value and the results have been presented and analysed to ascertain the effectiveness of IPFC for contingency management.
- 23 October 2016
- Published by Taylor & Francis in Australian Journal of Electrical and Electronics Engineering
- Vol. 13 (4) , 211-219
A line utilization contingency distribution index based secured operation of power system
The practical power systems undergo variable load throughout the year. Maintaining security and reliability in operation of these structures in such a vulnerable scenario is a huge challenge. In this paper, a line utilisation contingency distribution index (LUCDI) has been proposed for obtaining the weakest line of the real-time power system in cases of contingency. The contingency analysis has been executed for every hour load of the IEEE 30-bus system. The LUCDI has been computed for every transmission line of the power system for the severe-most outage, which specifies the stress on the transmission lines as a result of contingency for a real-time load. An interline power flow controller (IPFC) has been positioned and tuned to recover the system from the post-contingency condition. A function with multiple objectives has been used for tuning the IPFC using differential evolution and results have been evaluated to highlight the benefits of an IPFC for management of post-contingency condition in a real-time context.
- 23 October 2016
- Published by Taylor & Francis in Australian Journal of Electrical and Electronics Engineering
- Vol. 13 (4) , 211-219
A line utilization contingency distribution index based secured operation of power system
The practical power systems undergo variable load throughout the year. Maintaining security and reliability in operation of these structures in such a vulnerable scenario is a huge challenge. In this paper, a line utilisation contingency distribution index (LUCDI) has been proposed for obtaining the weakest line of the real-time power system in cases of contingency. The contingency analysis has been executed for every hour load of the IEEE 30-bus system. The LUCDI has been computed for every transmission line of the power system for the severe-most outage, which specifies the stress on the transmission lines as a result of contingency for a real-time load. An interline power flow controller (IPFC) has been positioned and tuned to recover the system from the post-contingency condition. A function with multiple objectives has been used for tuning the IPFC using differential evolution and results have been evaluated to highlight the benefits of an IPFC for management of post-contingency condition in a real-time context.
- 1 October 2016
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 26, 132-141
Composite Severity Indices Based Contingency Management of Power System: A Comparative Study
Severity assessment of transmission lines is a very important aspect of contingency analysis of a power system. Thereafter, a proper solution needs to be provided to ensure a secured power supply. In this paper, rapid contingency ranking technique (RCRT) has been introduced for the contingency assessment of a power system. Several composite indices have been designed by forming different combinations of line overload indices and voltage stability indices and the results have been compared. Deterministic and probabilistic approach have been used for the placement of IPFC and the results have been compared. While, the probability approach protects the system against most of the contingencies, the deterministic approach protects the system against the severe-most contingency. Thereafter, the IPFC is tuned using the differential evolution method. A multi-objective function has been formulated for tuning the device. The use of IPFC to overcome the post-contingency problems has been reinforced by implementing the proposed strategy on an IEEE 57 bus system.
- 1 October 2016
- Published by Trans Tech Publications, Ltd. in International Journal of Engineering Research in Africa
- Vol. 26, 132-141
Composite Severity Indices Based Contingency Management of Power System: A Comparative Study
Severity assessment of transmission lines is a very important aspect of contingency analysis of a power system. Thereafter, a proper solution needs to be provided to ensure a secured power supply. In this paper, rapid contingency ranking technique (RCRT) has been introduced for the contingency assessment of a power system. Several composite indices have been designed by forming different combinations of line overload indices and voltage stability indices and the results have been compared. Deterministic and probabilistic approach have been used for the placement of IPFC and the results have been compared. While, the probability approach protects the system against most of the contingencies, the deterministic approach protects the system against the severe-most contingency. Thereafter, the IPFC is tuned using the differential evolution method. A multi-objective function has been formulated for tuning the device. The use of IPFC to overcome the post-contingency problems has been reinforced by implementing the proposed strategy on an IEEE 57 bus system.
- Open Access
- 1 July 2016
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 10 (10) , 2327-2335
Real power performance index and line stability index‐based management of contingency using firefly algorithm
Provision of secured and uninterrupted supply of power is an essential pre‐requisite for the electrical industry. Hence, FACTS devices need to be employed efficiently to ensure the security of the power system. This study proposes, a repetition of severity‐based strategy of placement of interline power flow controller (IPFC) using composite severity index (CSI) for contingency management. The formulated CSI is a combination of real power performance index) and line stability index L mn . Thus, the CSI is expected to provide an exact measure of stress on the lines in terms of MW overloading and voltage instability. The IPFC is further tuned for a multi‐objective function using firefly algorithm. To verify the proposed methodology, it has been tested and implemented on IEEE 30 and Indian utility 62 bus system. The system has been further tested under highly stressful condition by increasing the load on the maximum loaded bus up to the critical value. The results have been presented and analysed to determine the effectiveness of IPFC for contingency management.
- 1 July 2016
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 10 (10) , 2327-2335
Open AccessReal power performance index and line stability index‐based management of contingency using firefly algorithm
Provision of secured and uninterrupted supply of power is an essential pre‐requisite for the electrical industry. Hence, FACTS devices need to be employed efficiently to ensure the security of the power system. This study proposes, a repetition of severity‐based strategy of placement of interline power flow controller (IPFC) using composite severity index (CSI) for contingency management. The formulated CSI is a combination of real power performance index) and line stability index L mn . Thus, the CSI is expected to provide an exact measure of stress on the lines in terms of MW overloading and voltage instability. The IPFC is further tuned for a multi‐objective function using firefly algorithm. To verify the proposed methodology, it has been tested and implemented on IEEE 30 and Indian utility 62 bus system. The system has been further tested under highly stressful condition by increasing the load on the maximum loaded bus up to the critical value. The results have been presented and analysed to determine the effectiveness of IPFC for contingency management.
- Open Access
- 16 June 2016
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 14 (2) , 104 - 112
Disparity Line Utilization Factor Based Optimal Placement of IPFC for Congestion Management
Recently, due to the adoption of power reforms, there is a marked increase of contracted power that flows in the transmission line and also the spontaneous power exchanges leading to complex power transmission congestion problems. The appearance of Flexible AC Transmission Systems (FACTS) devices specifically Interline Power Flow Controller (IPFC) has opened up new opportunities to overcome the congestion problem by increasing the possible system load. Hence, the optimal placement of FACTS devices is deservedly an issue of great importance. This paper proposes a Disparity Line Utilization Factor (DLUF) for the optimal placement of IPFC to control the congestion in transmission lines. DLUF determines the difference between the percentage MVA utilization of each line connected to the same bus. The proposed method is implemented for IEEE–14 and IEEE-57 bus test system. The IPFC is placed in all possible line combinations of IEEE-14 bus system to check the validity of the proposed methodology. To confirm the generality of the proposed method, the technique is also implemented and verified for IEEE-57 bus test system. An increased load of 110% and 125% is applied, and the results are presented and analysed in detail to establish the effectiveness of the proposed methodology.
- 16 June 2016
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 14 (2) , 104 - 112
Open AccessDisparity Line Utilization Factor Based Optimal Placement of IPFC for Congestion Management
Recently, due to the adoption of power reforms, there is a marked increase of contracted power that flows in the transmission line and also the spontaneous power exchanges leading to complex power transmission congestion problems. The appearance of Flexible AC Transmission Systems (FACTS) devices specifically Interline Power Flow Controller (IPFC) has opened up new opportunities to overcome the congestion problem by increasing the possible system load. Hence, the optimal placement of FACTS devices is deservedly an issue of great importance. This paper proposes a Disparity Line Utilization Factor (DLUF) for the optimal placement of IPFC to control the congestion in transmission lines. DLUF determines the difference between the percentage MVA utilization of each line connected to the same bus. The proposed method is implemented for IEEE–14 and IEEE-57 bus test system. The IPFC is placed in all possible line combinations of IEEE-14 bus system to check the validity of the proposed methodology. To confirm the generality of the proposed method, the technique is also implemented and verified for IEEE-57 bus test system. An increased load of 110% and 125% is applied, and the results are presented and analysed in detail to establish the effectiveness of the proposed methodology.
- 21 May 2016
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (10) , 1188-1202
A Fast Contingency Management Approach with Optimal Placement and Tuning of Interline Power Flow Controller Using Differential Evolution Algorithm
In the traditional approach of steady-state contingency screening, each line is removed sequentially and its effect on the system is studied, while only some contingencies may cause certain lines to become severe. This article presents an approach for fast contingency ranking in steady-state, based on the selection of a limited number of important buses. A composite severity index based placement of interline power flow controller and tuning using differential evolution for IEEE 14- and 30-bus systems has also been proposed. The composite severity index is a combination of line utilization factor and fast voltage stability index. All the lines connected to the important buses only are sequentially considered for line outage and the most severe line corresponding to each outage is ranked on the basis of composite severity index. An interline power flow controller is optimally placed and tuned to improve the system post-contingency condition. Differential evolution has been used to tune the device for a multi-objective function. The load on the system is increased to test the performance of the interline power flow controller under highly stressed conditions.
- 21 May 2016
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (10) , 1188-1202
A Fast Contingency Management Approach with Optimal Placement and Tuning of Interline Power Flow Controller Using Differential Evolution Algorithm
In the traditional approach of steady-state contingency screening, each line is removed sequentially and its effect on the system is studied, while only some contingencies may cause certain lines to become severe. This article presents an approach for fast contingency ranking in steady-state, based on the selection of a limited number of important buses. A composite severity index based placement of interline power flow controller and tuning using differential evolution for IEEE 14- and 30-bus systems has also been proposed. The composite severity index is a combination of line utilization factor and fast voltage stability index. All the lines connected to the important buses only are sequentially considered for line outage and the most severe line corresponding to each outage is ranked on the basis of composite severity index. An interline power flow controller is optimally placed and tuned to improve the system post-contingency condition. Differential evolution has been used to tune the device for a multi-objective function. The load on the system is increased to test the performance of the interline power flow controller under highly stressed conditions.
- Open Access
- 1 March 2016
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 7 (1) , 209-222
Contingency management of power system with Interline Power Flow Controller using Real Power Performance Index and Line Stability Index
- 1 March 2016
- Published by Elsevier in Ain Shams Engineering Journal
- Vol. 7 (1) , 209-222
Open AccessContingency management of power system with Interline Power Flow Controller using Real Power Performance Index and Line Stability Index