Dahlia M. Kenawy
Research Subjects
Dahlia M. Kenawy has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Bryan W. Tillman
Division of Vascular Surgery, The Ohio State University Wexner Medical Center, Columbus, OH
2 shared publications Jennifer M. Underhill
United States Naval Hospital Okinawa, Department of General Surgery, FPO, AP 96362
2 shared publicationsSavannah M. Renshaw
Center for Abdominal Core Health, Department of Surgery, Division of General and Gastrointestinal Surgery, The Ohio State University Wexner Medical Center, N729 Doan Hall, 410 W. Tenth Avenue, Columbus, OH 43210
2 shared publicationsArt Sedrakyan
Department of Population Health Sciences, Weill Cornell Medical College, 570 Lexington Avenue, New York, NY 10022
1 shared publicationAyanna G. Jacobs
Center for Abdominal Core Health, The Ohio State University Wexner Medical Center, Columbus, USA
1 shared publicationAysenur Gunacar
Center for Abdominal Core Health, The Ohio State University Wexner Medical Center, Columbus, USA
1 shared publication
Latest Publications
- 10 February 2026
- Published by Wolters Kluwer Health in Annals of Surgery
An Observational Cohort Study on Non-Recurrence Procedural Intervention and Reoperation for Recurrence After Ventral Hernia Repair
Objective: To establish the use of Non-Recurrence Procedural Intervention (NRPI) and Reoperation for Recurrence (ROR) as long-term outcome measures after ventral hernia repair (VHR). NRPI is a novel, claims-based measure sensitive to procedures performed to manage complications after VHR. Summary Background Data: Obtaining long-term follow-up after VHR is difficult. Clinical registry linkages with administrative claims data offer a novel solution to assess long-term complications and recurrence. This study provides validation of coding algorithms for these outcomes to ensure reproducibility and scalability. Methods: This was an observational cohort study of patients undergoing VHR from 2011-2019 at a single tertiary care center. Claims-based coding algorithms for NRPI and ROR were compared to abstracted electronic health record (EHR) information. The main outcome was cumulative incidence of long-term NRPI and ROR. P P =0.0184. Similar results were found for ROR: claims 6.84% (95%CI 5.43-8.25%) and EHR 7.00% (95%CI 5.58-8.43%), P =0.6547. Conclusions: NRPI and ROR cumulative incidence rates are similar using the claims-based coding algorithm and EHR data. The algorithm can be used to enhance long-term follow-up through clinical registry linkages with administrative claims data. This will enable robust long-term assessment for research, quality improvement, and post-market device surveillance.
- 10 February 2026
- Published by Wolters Kluwer Health in Annals of Surgery
An Observational Cohort Study on Non-Recurrence Procedural Intervention and Reoperation for Recurrence After Ventral Hernia Repair
Objective: To establish the use of Non-Recurrence Procedural Intervention (NRPI) and Reoperation for Recurrence (ROR) as long-term outcome measures after ventral hernia repair (VHR). NRPI is a novel, claims-based measure sensitive to procedures performed to manage complications after VHR. Summary Background Data: Obtaining long-term follow-up after VHR is difficult. Clinical registry linkages with administrative claims data offer a novel solution to assess long-term complications and recurrence. This study provides validation of coding algorithms for these outcomes to ensure reproducibility and scalability. Methods: This was an observational cohort study of patients undergoing VHR from 2011-2019 at a single tertiary care center. Claims-based coding algorithms for NRPI and ROR were compared to abstracted electronic health record (EHR) information. The main outcome was cumulative incidence of long-term NRPI and ROR. P P =0.0184. Similar results were found for ROR: claims 6.84% (95%CI 5.43-8.25%) and EHR 7.00% (95%CI 5.58-8.43%), P =0.6547. Conclusions: NRPI and ROR cumulative incidence rates are similar using the claims-based coding algorithm and EHR data. The algorithm can be used to enhance long-term follow-up through clinical registry linkages with administrative claims data. This will enable robust long-term assessment for research, quality improvement, and post-market device surveillance.
- Open Access
High Accuracy Location Tracking for a Hemostasis Stent Achieved by the Fusion of Comprehensively Denoised Magnetic and Inertial Measurements
This paper will introduce a location tracking system targeted on a stent when it is deployed into the human artery to achieve hemostasis. This system is proposed to be applied in emergent conditions such as treating injured soldiers on the battlefield where common surgical devices such as fluoroscopy systems are not available. The locating algorithm is based on both magnetic measurements and inertial measurements. The magnetic locating approach detects the sensor’s location in a coordinate system centered with the reference magnet source. The inertial locating approach integrates the linear acceleration and angular velocity measured by the sensor to obtain the angular and linear displacement during a time period. Measurements from all sensors are deeply fused to remove disturbances and noise that degrade the locating accuracy. The focus of this research is to identify all potential error-increasing factors and then provide solutions to correct them to enhance the location measurement reliability. Validation experiments for each improvement approach and the overall locating performance will be introduced.
Open AccessHigh Accuracy Location Tracking for a Hemostasis Stent Achieved by the Fusion of Comprehensively Denoised Magnetic and Inertial Measurements
This paper will introduce a location tracking system targeted on a stent when it is deployed into the human artery to achieve hemostasis. This system is proposed to be applied in emergent conditions such as treating injured soldiers on the battlefield where common surgical devices such as fluoroscopy systems are not available. The locating algorithm is based on both magnetic measurements and inertial measurements. The magnetic locating approach detects the sensor’s location in a coordinate system centered with the reference magnet source. The inertial locating approach integrates the linear acceleration and angular velocity measured by the sensor to obtain the angular and linear displacement during a time period. Measurements from all sensors are deeply fused to remove disturbances and noise that degrade the locating accuracy. The focus of this research is to identify all potential error-increasing factors and then provide solutions to correct them to enhance the location measurement reliability. Validation experiments for each improvement approach and the overall locating performance will be introduced.
- Open Access
- 7 December 2023
- Published by BMJ in Trauma Surgery & Acute Care Open
- Vol. 8 (1) , e001220
A self calibrating, magnetic sensor approach accurately positions an aortic damage control stent in a porcine model
Objectives Non-compressible torso hemorrhage remains a high mortality injury, with difficulty mobilizing resources before exsanguination. Previous studies reported on a retrievable stent graft for damage control and morphometric algorithms for rapid placement, yet fluoroscopy is impractical for the austere environment. We hypothesized that magnetic sensors could be used to position stents relative to an external magnet placed on an anatomic landmark, whereas an electromagnet would allow self-calibration to account for environmental noise. Methods A magnetic sensor alone (MSA) and with integrated stent (MSIS) were examined in a porcine model under anesthesia. A target electromagnet was placed on the xiphoid process (position 0 cm). Sensors were placed in the aorta and measurements obtained at positions 0 cm, +4 cm, and +12 cm from the magnet and compared with fluoroscopy. Sensors were examined under conditions of tachycardia/hypertension, hypotension, vibration, and metal shrapnel to simulate environmental factors that might impact accuracy. General linear models compared mean differences between fluoroscopy and sensor readings. Results Both sensors were compatible with a 10 French catheter system and provided real-time assessment of the distance between the sensor and magnetic target in centimeters. Mean differences between fluoroscopy and both magnetic sensor readings demonstrated accuracy within ±0.5 cm for all but one condition at 0 cm and +4 cm, whereas accuracy decreased at +12 cm from the target. Using the control as a reference, there was no significant difference in mean differences between fluoroscopy and both MSA or MSIS readings at 0 cm and +4 cm for all conditions. The system retained effectiveness if the target was overshot. Conclusion Magnetic sensors achieved the highest accuracy as sensors approached the target. Oscillation of the electromagnet on and off effectively accounts for environmental noise. This approach is promising for rapid and accurate placement of damage control retrievable stent grafts when fluoroscopy is impractical. Level of evidence Not applicable.
- 7 December 2023
- Published by BMJ in Trauma Surgery & Acute Care Open
- Vol. 8 (1) , e001220
Open AccessA self calibrating, magnetic sensor approach accurately positions an aortic damage control stent in a porcine model
Objectives Non-compressible torso hemorrhage remains a high mortality injury, with difficulty mobilizing resources before exsanguination. Previous studies reported on a retrievable stent graft for damage control and morphometric algorithms for rapid placement, yet fluoroscopy is impractical for the austere environment. We hypothesized that magnetic sensors could be used to position stents relative to an external magnet placed on an anatomic landmark, whereas an electromagnet would allow self-calibration to account for environmental noise. Methods A magnetic sensor alone (MSA) and with integrated stent (MSIS) were examined in a porcine model under anesthesia. A target electromagnet was placed on the xiphoid process (position 0 cm). Sensors were placed in the aorta and measurements obtained at positions 0 cm, +4 cm, and +12 cm from the magnet and compared with fluoroscopy. Sensors were examined under conditions of tachycardia/hypertension, hypotension, vibration, and metal shrapnel to simulate environmental factors that might impact accuracy. General linear models compared mean differences between fluoroscopy and sensor readings. Results Both sensors were compatible with a 10 French catheter system and provided real-time assessment of the distance between the sensor and magnetic target in centimeters. Mean differences between fluoroscopy and both magnetic sensor readings demonstrated accuracy within ±0.5 cm for all but one condition at 0 cm and +4 cm, whereas accuracy decreased at +12 cm from the target. Using the control as a reference, there was no significant difference in mean differences between fluoroscopy and both MSA or MSIS readings at 0 cm and +4 cm for all conditions. The system retained effectiveness if the target was overshot. Conclusion Magnetic sensors achieved the highest accuracy as sensors approached the target. Oscillation of the electromagnet on and off effectively accounts for environmental noise. This approach is promising for rapid and accurate placement of damage control retrievable stent grafts when fluoroscopy is impractical. Level of evidence Not applicable.
- 8 November 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 37 (7) , 5612-5622
Ten-year outcomes following ventral hernia repair: making the case for better post-market surveillance in the USA
Background We sought to identify the 10-year complication and recurrence rates and associated sociodemographic and operative characteristics associated with non-mesh versus mesh-based ventral hernia repairs (VHRs). Methods This was an IRB-approved (2020H0317) retrospective longitudinal study of patients undergoing mesh or non-mesh VHR from 2009–2019 at a single tertiary-care institution. The electronic medical record was used to collect sociodemographic, clinical, and intraoperative details, and early (≤ 30 days) and long-term (> 30-day) postoperative complications. Up to ten-year follow-up was obtained for long-term complications, categorized as: hernia recurrence reoperation (HRR), major complications requiring emergency surgery (MCES) (defined as non-elective operations related to the abdominal wall), and non-recurrence procedural intervention (NRPI) (defined as any procedures related to the abdominal wall, bowel, or mesh). Kaplan–Meier survival curves were obtained for each long-term complication. Results Of the 645 patients identified, the mean age at index operation was 52.51 ± 13.57 years with 50.70% female. Of the index operations, 21.24% were for a recurrence. Procedure categories included: 57.36% incisional, 37.21% non-incisional umbilical, 8.22% non-incisional epigastric, 3.88% parastomal, 0.93% diastasis recti, and 0.47% Spigelian hernias. Operative approaches included open (n = 383), laparoscopic (n = 267), and robotic (n = 21). Fascial closure (81.55%) and mesh use (66.2%) were performed in the majority of cases. Median follow-up time was 2098 days (interquartile range 1320–2806). The rate of short-term complications was 4.81% for surgical site infections, 15.04% for surgical site occurrences, and 13.64% for other complications. At 10 years, the HRR-free survival probability was 85.26%, MCES-free survival probability was 94.44%, and NRPI-free survival probability was 78.11%. Conclusions A high proportion of patients experienced long-term recurrence and complications requiring intervention after index VHR. For many patients, a ventral hernia develops into a chronic medical condition. Improved efforts at post-market surveillance of operative approaches and mesh location and type should be undertaken to help optimize outcomes. Graphical abstract
- 8 November 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 37 (7) , 5612-5622
Ten-year outcomes following ventral hernia repair: making the case for better post-market surveillance in the USA
Background We sought to identify the 10-year complication and recurrence rates and associated sociodemographic and operative characteristics associated with non-mesh versus mesh-based ventral hernia repairs (VHRs). Methods This was an IRB-approved (2020H0317) retrospective longitudinal study of patients undergoing mesh or non-mesh VHR from 2009–2019 at a single tertiary-care institution. The electronic medical record was used to collect sociodemographic, clinical, and intraoperative details, and early (≤ 30 days) and long-term (> 30-day) postoperative complications. Up to ten-year follow-up was obtained for long-term complications, categorized as: hernia recurrence reoperation (HRR), major complications requiring emergency surgery (MCES) (defined as non-elective operations related to the abdominal wall), and non-recurrence procedural intervention (NRPI) (defined as any procedures related to the abdominal wall, bowel, or mesh). Kaplan–Meier survival curves were obtained for each long-term complication. Results Of the 645 patients identified, the mean age at index operation was 52.51 ± 13.57 years with 50.70% female. Of the index operations, 21.24% were for a recurrence. Procedure categories included: 57.36% incisional, 37.21% non-incisional umbilical, 8.22% non-incisional epigastric, 3.88% parastomal, 0.93% diastasis recti, and 0.47% Spigelian hernias. Operative approaches included open (n = 383), laparoscopic (n = 267), and robotic (n = 21). Fascial closure (81.55%) and mesh use (66.2%) were performed in the majority of cases. Median follow-up time was 2098 days (interquartile range 1320–2806). The rate of short-term complications was 4.81% for surgical site infections, 15.04% for surgical site occurrences, and 13.64% for other complications. At 10 years, the HRR-free survival probability was 85.26%, MCES-free survival probability was 94.44%, and NRPI-free survival probability was 78.11%. Conclusions A high proportion of patients experienced long-term recurrence and complications requiring intervention after index VHR. For many patients, a ventral hernia develops into a chronic medical condition. Improved efforts at post-market surveillance of operative approaches and mesh location and type should be undertaken to help optimize outcomes. Graphical abstract
- 1 October 2021
- Published by Elsevier in Journal of Surgical Research
- Vol. 266, 320-327
Increasing Frailty in Geriatric Emergency General Surgery: A Cause for Concern
- 1 October 2021
- Published by Elsevier in Journal of Surgical Research
- Vol. 266, 320-327
Increasing Frailty in Geriatric Emergency General Surgery: A Cause for Concern
- 13 July 2021
- Published by Elsevier in The American Journal of Surgery
- Vol. 223 (2) , 243-244
Evaluating the role of the minimal clinically important difference for the hernia-related quality of Life Survey – How do we know who will benefit from hernia repair?
- 13 July 2021
- Published by Elsevier in The American Journal of Surgery
- Vol. 223 (2) , 243-244
Evaluating the role of the minimal clinically important difference for the hernia-related quality of Life Survey – How do we know who will benefit from hernia repair?