JLJintao Lei

Jintao Lei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jintao Lei has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Transient Stability Analysis for Paralleled System of Virtual Synchronous Generators Based on Damping Energy Visualization and Approximation

    by Qiannan Qu, Xin Xiang, Jintao Lei, Wuhua Li, Xiangning He

    With the increasing penetration of virtual synchronous generator (VSG)-controlled inverters in the renewable power system, the transient stability analysis of the paralleled VSG system with the interactions between inverters is urgently needed. However, the large damping effect brought by VSGs on the relative motion between inverters is still unclear, which impedes the accurate transient stability evaluation of the paralleled system. In this article, the damping effect in the paralleled VSG system is explored with the recognition of the uniform and the nonuniform damping effects, and it is found that the large damping in VSGs may also destabilize the system under some nonuniform damping configurations. To figure out the influential mechanism of the damping terms in the paralleled VSGs, two customized phase portraits are presented to visualize the uniform and the nonuniform damping energies with the respective areas. On top of that, a damping energy approximation method is further proposed to quantitatively depict damping energy, and thus, the critical clearing time can be analytically solved. The effectiveness of the proposed method is validated by both simulation results and control hardware-in-loop experimental results. The results demonstrate that the proposed method can clearly characterize the large damping effects and accurately solve the critical fault clearing point, which may provide some new insights for the transient stability analysis of the paralleled VSG system.


  • Parameter Boundary Characterization for DC Microgrid Islanding Detection Based on Time-Domain Voltage Oscillation Trajectory Analysis

    by Tianling Shi, Xin Xiang, Jintao Lei, Boxin Liu, Fei Wang, Li Li, Ricardo P. Aguilera, Wuhua Li

    Unintentional islanding events cause potential threats to the safety of dc microgrids. Selected frequency islanding detection is considered a promising technology thanks to its good power quality and high detection accuracy. However, the conventional frequency-domain-based islanding detection parameter boundary cannot consider the impact of detection time, which causes a quite slow detection speed and thus leads to detection failure. To overcome this obstacle, a linear model of the islanding dc system is developed first to analyze the steady-state response of the voltage at the point of common coupling (PCC). On top of that, the components of the islanding system characteristic equation are analyzed based on modal analysis, which lays a good foundation for simplifying the time-domain response model of the PCC voltage. Then, the oscillation trajectory of the PCC voltage triggered by the islanding event is characterized in the time domain, which facilitates the analysis and calculation of islanding detection time. Furthermore, the boundary of the islanding detection parameters considering the detection time effect is accurately depicted to guide the resonator design. In this manner, the effect of resonant parameters on the detection time can be evaluated visually while the fast detection speed is also ensured. Finally, the proposed method is validated in simulations and hardware-in-loop experiments.


  • On the Destabilizing Mechanism of Nonuniform Damping in Grid-Forming Converters Penetrated Multi-Machine System

    by Jintao Lei, Xin Xiang, Qiannan Qu, Wuhua Li, Xiangning He

    The nonuniform large damping introduced by grid-forming (GFM) converters in multi-machine system could destabilize the power system under large disturbance, which may bring new challenges to the safe operation of future power system. In this letter, the mathematic model of GFM-penetrated multi-machine system considering large damping effect is established first, and the concept of uniform and nonuniform damping energy is further proposed to clarify the impact of different damping components. Moreover, the influence mechanism of nonuniform damping on system transient stability is revealed, which implies that the large damping in only part of generators could destabilize the system. The analysis result may provide some new insights for the transient stability analysis of future power system with nonuniform damping effect.


  • Communication-Less Active Damping Method With VSC for Stability Improvement of Grid-Connected DC Microgrid With Selected Frequency Islanding Detection

    by Tianling Shi, Xin Xiang, Jintao Lei, Boxin Liu, Fei Wang, Huan Yang, Li Li, Wuhua Li

    The islanding detection method (IDM) with current disturbance of selected frequency (CDSF) in dc microgrids is gaining extensive attention thanks to its small nondetection zone and good power quality. However, the CDSF is implemented through a positive feedback loop and thus will lead to instability issues for the dc microgrid even in the grid-connected mode. Conventional stabilization control is generally employed on the distributed generator (DG) side and usually requires an additional uninterrupted communication process, which therefore decreases system reliability. In this article, the impedance model of the dc microgrid is established first to reveal the interaction instability mechanism between the voltage source converter (VSC) and DG equipped with CDSF IDM. On top of that, the notch-filter-based active damping method is proposed on the VSC side to avoid amplitude intersection of impedance near the selected resonant frequency, which effectively mitigates the instability caused by the islanding detection loop without relying on communication. Moreover, the parameter design method is further summarized to provide guidance for the selection of notch bandwidth in the proposed damper. In this manner, the stability of the grid-connected system can be improved while the islanding detecting speed is enhanced. In the end, the effectiveness of the proposed stabilizing method is verified by the experiments.


  • Detection Threshold Design for DC Islanding Detection with Static Disturbing Frequency

    by Tianling Shi, Yonghao Li, Boxin Liu, Jintao Lei, Fei Wang, Xin Xiang, Wuhua Li

    Anti-islanding approach with current perturbation of particular frequency in dc microgrids has attracted wide attention in recent years. Nevertheless, the static perturbation frequency selected from the rated conditions shifts with system power variation, and thus will lead to a detection failure. In this article, the function of current perturbation to the output voltage of distributed generations is derived to illustrate the root cause of the frequency shift problem. On top of that, the design method of detection threshold is proposed to ensure successful detection. At last, the effectiveness and accuracy of the detection threshold design method is proved by the simulations.

  • Nondetection Zone Elimination and Detection Speed Improvement for DC Microgrids Islanding Detection With Adaptive Resonant Frequency

    by Tianling Shi, Xin Xiang, Jintao Lei, Boxin Liu, Fei Wang, Min Chen, Huan Yang, Li Li, Wuhua Li

    Islanding detection based on current disturbance of selected frequency is gaining widespread acceptance in dc microgrids due to its high detecting accuracy and good power quality. However, the selected static disturbance frequency at a specific operating state causes the expansion of the non-detection zone (NDZ) and the decrease of the detection speed under different system power conditions. In this paper, the sensitivity model of current perturbation is developed to intuitively reveal the mechanism of oscillation frequency shift and the occurrence of the NDZ. Then, the theoretical resonant frequency is derived to analyze the frequency shift range with the consideration of system power changing, which provides the NDZ boundaries accurately. Moreover, an islanding detection method (IDM) with the adaptive resonant frequency is proposed to provide zero NDZ and fast detection speed by dynamically selecting the most sensitive frequency in different power operating cases. Thus, the conflict between the NDZ and detection speed is effectively addressed. Finally, the effectiveness of the proposed IDM is validated by both the simulations and experimental results.


  • Virtual Damping Stabilizing for DC Microgrid with Current Disturbance of Selected Frequency Islanding Detection Method

    by Tianling Shi, Boxin Liu, Jintao Lei, Fei Wang, Xin Xiang, Li Li, Wuhua Li

    In recent years, dc islanding detection based on current disturbance of selected frequency (CDSF) is becoming a promising technique because it has fast detecting speed and good power quality. However, the implementation of the CDSF potentially causes stability issues in the grid-connected dc microgrid. In this paper, the impedance characteristics of the voltage source converter (VSC) and distributed generators (DGs) equipped with CDSF are investigated to reveal the instability mechanism of the cascaded system. Moreover, a virtual damping stabilizing control based on the dc grid current feed-forward is proposed to cancel out the oscillation peak of the VSC, which effectively mitigates the instability associated with the CDSF loop. Finally, the theoretical development is verified by simulation results.

  • Top Cited Papers

    Transient Stability Analysis of Grid Forming Converters Based on Damping Energy Visualization and Geometry Approximation

    by Jintao Lei, Xin Xiang, Boxin Liu, Wuhua Li, Xiangning He

    The damping effect in grid forming (GFM) control is inherently large and thus has great impact on its transient stability. Although qualitative understanding of damping has been developed in recent studies, an analytical and intuitive method for quantitative assessment of damping is still needed to be developed to date. This paper visualizes the transient damping energy through the concept of damping area on a tailored phase portrait to physically and intuitively understand the damping effect. On top of that, the damping energy approximation (DEA) method is further proposed to depict transient stability boundary more accurately and evaluate the critical clearing angle analytically. Moreover, the conservativeness of proposed DEA method for GFM converter with both constant terminal voltage control (CTVC) and reactive power-voltage droop control (QVDC) is analyzed in theory and verified in time-domain simulations and control hardware-in-loop (CHIL) experiments. This method quantitatively and visually evaluates the impact of damping on transient stability boundary and critical clearing angle, which avoids complex numerical iterations and may provide some insights into the transient stability analysis of GFM converter.


  • Proportional Resonant Control With Phase Correction for Stability and Dynamics Enhancement Under Low Carrier Ratio Conditions

    by Ye Yan, Jintao Lei, Boxin Liu, Xin Xiang, Chushan Li, Chengmin Li, Wuhua Li, Xiangning He

    Phase-corrected proportional resonant (PCPR) current controllers are mainly studied under high carrier ratio conditions. When applied to high-power converters with low carrier ratios, the system could be unstable or have poor dynamics without a proper parameter design. In order to illustrate both stability and dynamics to guide parameter design, bilateral Bode plots are tailored in this article that considers the correct negative jump direction at resonant frequencies. Then, this analysis tool verifies the feasibility of the phase correction angle set over 90°, especially under a carrier ratio below six. With the designed phase correction, the stability region of the carrier ratios is characterized as extending to the theoretical limit of one. Moreover, the resonant gain of PCPR is quantitatively designed considering the variation of carrier ratios by maximizing the bandwidth under guaranteed stability and margins. Finally, the simulations and experiments verify the enlarged stability region with the phase correction and improved dynamic performance with the proposed resonant gain design method.


  • Quantitative and Intuitive VSG Transient Analysis With the Concept of Damping Area Approximation

    by Jintao Lei, Xin Xiang, Boxin Liu, Wuhua Li, Xiangning He

    The inherent large damping effect in virtual synchronous generator (VSG) control brings great challenges to its transient analysis. The recent studies mainly focus on qualitative explanation of damping effect, lacking an intuitive and quantitative assessment method. In this letter, the concept of damping area is introduced to visualize the transient damping energy in a tailored phase portrait, which facilitates the physical and intuitive understanding of damping effects. On top of that, the damping area approximation method is further proposed to evaluate attraction domain quantitatively, and its conservativeness for VSG control is proved in theory and validated by experiments. The proposed method evaluates the impact of damping on attraction domain quantitatively and intuitively, and it may provide some insights into the VSG transient stability analysis.