Tianling Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tianling Shi has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Fei Wang
Shanghai University
12 shared publications - Xin Xiang
Zhejiang University
11 shared publications - Wuhua Li
Zhejiang University
10 shared publications - Boxin Liu
College of Electrical Engineering, Zhejiang University, Hangzhou, China
9 shared publications - Jintao Lei
College of Electrical Engineering, Zhejiang University, Hangzhou, China
5 shared publications - Li Li
University of Technology Sydney
5 shared publications
Latest Publications
- 29 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A Highly Integrated Electric Traction System with Bidirectional Energy Conversion for EVs/HEVs
Highly integrated electric traction system (ETS) is a key technology for promoting electric vehicles (EVs) and hybrid electric vehicles (HEVs). This paper proposes an integrated ETS with bidirectional energy conversion, aiming to reduce costs at the power electronics level. Unlike conventional ETS configurations, the proposed system eliminates the need for a separate physical DC/DC converter. Instead, it powers the battery bank through the neutral point of the traction motor using a smoothing inductor. To clearly illustrate the operating principles, a detailed mathematical model of the system is developed. Two equivalent circuits representing the positive-sequence and zero-sequence components are derived from the model. The zero-sequence circuit effectively fulfills the role of a bidirectional DC/DC converter. Power flow behavior under both driving and regenerative braking conditions is analyzed within these two circuit frameworks. To enable coordinated control of the traction motor and DC bus voltage, an extended field-oriented control (EFOC) strategy is introduced, incorporating additional regulators for DC bus voltage and neutral-point current. Finally, comparative experiments are conducted on a 1.2 kW test bench, demonstrating the effectiveness of the proposed ETS and its control strategy under both motoring and braking operations.
- 29 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A Highly Integrated Electric Traction System with Bidirectional Energy Conversion for EVs/HEVs
Highly integrated electric traction system (ETS) is a key technology for promoting electric vehicles (EVs) and hybrid electric vehicles (HEVs). This paper proposes an integrated ETS with bidirectional energy conversion, aiming to reduce costs at the power electronics level. Unlike conventional ETS configurations, the proposed system eliminates the need for a separate physical DC/DC converter. Instead, it powers the battery bank through the neutral point of the traction motor using a smoothing inductor. To clearly illustrate the operating principles, a detailed mathematical model of the system is developed. Two equivalent circuits representing the positive-sequence and zero-sequence components are derived from the model. The zero-sequence circuit effectively fulfills the role of a bidirectional DC/DC converter. Power flow behavior under both driving and regenerative braking conditions is analyzed within these two circuit frameworks. To enable coordinated control of the traction motor and DC bus voltage, an extended field-oriented control (EFOC) strategy is introduced, incorporating additional regulators for DC bus voltage and neutral-point current. Finally, comparative experiments are conducted on a 1.2 kW test bench, demonstrating the effectiveness of the proposed ETS and its control strategy under both motoring and braking operations.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 9463-9478
Power Losses Modeling and Thermal Imbalance Suppression of Modular Multilevel Resonant DC–DC Converters
Modular multilevel resonant dc-dc converter (MMRDCs) have garnered substantial research interest within the domain of medium-voltage dc to low-voltage dc applications. Nevertheless, compared with the traditional modular multilevel converter employed in high voltage dc transmission, due to the different operating principles and modulation techniques, the electrical and thermal stress distribution in MMRDC remains yet to be fully elucidated. In this article, the power losses of submodule (SM) devices in MMRDC are investigated comprehensively. A precise calculation model of the SM conduction and switching losses is established under different operation conditions. The calculations reveal the serious thermal imbalance features among the devices inside SM, which may curtail the device lifetime and thus threaten the converter reliability. Then, to alleviate the thermal imbalance, a modulation scheme by reassigning the current path inside the SM is proposed. Without extra hardware cost and influence on the output performance, the proposed modulation can mitigate the loss imbalance between the upper switch and lower switch significantly and reduce power losses of the most highly stressed device. Finally, the accuracy of the theoretical model and the efficacy of the thermal imbalance suppression modulation are corroborated by full-scaled simulation and an MV MMRDC laboratory prototype with 7–14 kV input and 300 V output.
- 3 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (7) , 9463-9478
Power Losses Modeling and Thermal Imbalance Suppression of Modular Multilevel Resonant DC–DC Converters
Modular multilevel resonant dc-dc converter (MMRDCs) have garnered substantial research interest within the domain of medium-voltage dc to low-voltage dc applications. Nevertheless, compared with the traditional modular multilevel converter employed in high voltage dc transmission, due to the different operating principles and modulation techniques, the electrical and thermal stress distribution in MMRDC remains yet to be fully elucidated. In this article, the power losses of submodule (SM) devices in MMRDC are investigated comprehensively. A precise calculation model of the SM conduction and switching losses is established under different operation conditions. The calculations reveal the serious thermal imbalance features among the devices inside SM, which may curtail the device lifetime and thus threaten the converter reliability. Then, to alleviate the thermal imbalance, a modulation scheme by reassigning the current path inside the SM is proposed. Without extra hardware cost and influence on the output performance, the proposed modulation can mitigate the loss imbalance between the upper switch and lower switch significantly and reduce power losses of the most highly stressed device. Finally, the accuracy of the theoretical model and the efficacy of the thermal imbalance suppression modulation are corroborated by full-scaled simulation and an MV MMRDC laboratory prototype with 7–14 kV input and 300 V output.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (6) , 4423-4434
Coordinated Operation of Active Distribution Network and Mobile Energy Storage Using Stackelberg Game
To improve system flexibility and reliability, mobile energy storage (MES) is treated as a unified dispatching resource of the active distribution network (ADN) to participate in operation optimization and power supply recovery. However, the coordinated optimization of MES with ADN network reconfiguration and voltage regulation is neglected in current studies. Especially, there exists blank research on ADN and MES as independent stakeholders. Therefore, a coordinated operation strategy based on the Stackelberg game for ADN and MES is proposed. Considering multitime period dynamic reconfiguration, voltage regulation, and their joint optimization with MES, the ADN as a leader, makes a tradeoff between expected profits and reliability to formulate reasonable prices for MES. As a follower, MES models energy transfer characteristics based on the space–time network and actively participates in the operation optimization of ADN by responding to the price decision to increase revenue. Following that, Karush–Kuhn–Tucker conditions are used to transform the two-layer optimization model based on the Stackelberg game into a single-layer mixed integer linear programming problem for solution. Finally, simulations on an improved IEEE-33 bus system validate the proposed strategy, which saves 2.2% of total social costs and reduces 6% of the voltage deviation.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (6) , 4423-4434
Coordinated Operation of Active Distribution Network and Mobile Energy Storage Using Stackelberg Game
To improve system flexibility and reliability, mobile energy storage (MES) is treated as a unified dispatching resource of the active distribution network (ADN) to participate in operation optimization and power supply recovery. However, the coordinated optimization of MES with ADN network reconfiguration and voltage regulation is neglected in current studies. Especially, there exists blank research on ADN and MES as independent stakeholders. Therefore, a coordinated operation strategy based on the Stackelberg game for ADN and MES is proposed. Considering multitime period dynamic reconfiguration, voltage regulation, and their joint optimization with MES, the ADN as a leader, makes a tradeoff between expected profits and reliability to formulate reasonable prices for MES. As a follower, MES models energy transfer characteristics based on the space–time network and actively participates in the operation optimization of ADN by responding to the price decision to increase revenue. Following that, Karush–Kuhn–Tucker conditions are used to transform the two-layer optimization model based on the Stackelberg game into a single-layer mixed integer linear programming problem for solution. Finally, simulations on an improved IEEE-33 bus system validate the proposed strategy, which saves 2.2% of total social costs and reduces 6% of the voltage deviation.
- 7 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (1) , 1125-1135
Series Arc Fault Detection by Modeling and Integral Regulated Residual Analysis
With the rapid development of renewable energy, photovoltaic systems, energy storage systems, and DC microgrids are widely used. However, arc faults can cause electrical fires and even compromise the safety and reliability of the system. In this paper, a modeling and integral-regulated-residual-analysis-based arc fault detection technique is developed for DC systems. The generalized state space average model of the DC system is developed under normal operation and arc fault conditions. The power electronic harmonics are considered in the modeling and analyzed to estimate the state variation of the system. The developed model can predict the arc current and can preliminarily determine the causes of variation. The integral regulated residual analysis method is proposed to calculate the intersection area between the model-predicted arc current and the actual arc current. The nominal values of the intersection area can be determined by experiments. Thus, an arc fault can be identified when the value of the intersection area reaches the nominal value. In this way, the modeling and integral regulated residual analysis algorithm is established and the arc detector is developed. The experimental results of 600 groups of tests verified that the technique can detect sustained and intermittent arc faults at different arc formation conditions with an accuracy of 99.5% within 80 ms despite the effects of line impedance, load transient and power electronics noise.
- 7 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (1) , 1125-1135
Series Arc Fault Detection by Modeling and Integral Regulated Residual Analysis
With the rapid development of renewable energy, photovoltaic systems, energy storage systems, and DC microgrids are widely used. However, arc faults can cause electrical fires and even compromise the safety and reliability of the system. In this paper, a modeling and integral-regulated-residual-analysis-based arc fault detection technique is developed for DC systems. The generalized state space average model of the DC system is developed under normal operation and arc fault conditions. The power electronic harmonics are considered in the modeling and analyzed to estimate the state variation of the system. The developed model can predict the arc current and can preliminarily determine the causes of variation. The integral regulated residual analysis method is proposed to calculate the intersection area between the model-predicted arc current and the actual arc current. The nominal values of the intersection area can be determined by experiments. Thus, an arc fault can be identified when the value of the intersection area reaches the nominal value. In this way, the modeling and integral regulated residual analysis algorithm is established and the arc detector is developed. The experimental results of 600 groups of tests verified that the technique can detect sustained and intermittent arc faults at different arc formation conditions with an accuracy of 99.5% within 80 ms despite the effects of line impedance, load transient and power electronics noise.
- Open Access
Stability Boundary Characterization and Power Quality Improvement for Distribution Networks
With the increasing proportion of distributed generators (DGs), distribution networks usually include grid forming (GFM) and grid following (GFL) converters. However, the incompatibility of dynamic performance caused by different control methods of the GFM and GFL converters may bring instability problems and power quality risks to the distribution network. To solve this issue, the models of the GFM and GFL converters are established first to lay a good foundation for stability analysis and power quality improvement control. On this basis, an inner loop parameters design scheme is developed for GFM converters based on the D-Partition method, which facilitates the stability boundary characterization. Meanwhile, a current injection strategy is proposed to enhance the voltage support capacity of the GFL converter during grid faults. Moreover, for the distribution network with multi-converters, a compensation current control based on the analytic hierarchy process and coefficient of variation is proposed to ensure a balance between minimal capacity and optimal power quality. In this manner, DGs can be plug-and-play without considering stability and power quality issues. Finally, the effectiveness of the proposed strategy is validated with simulation results.
Open AccessStability Boundary Characterization and Power Quality Improvement for Distribution Networks
With the increasing proportion of distributed generators (DGs), distribution networks usually include grid forming (GFM) and grid following (GFL) converters. However, the incompatibility of dynamic performance caused by different control methods of the GFM and GFL converters may bring instability problems and power quality risks to the distribution network. To solve this issue, the models of the GFM and GFL converters are established first to lay a good foundation for stability analysis and power quality improvement control. On this basis, an inner loop parameters design scheme is developed for GFM converters based on the D-Partition method, which facilitates the stability boundary characterization. Meanwhile, a current injection strategy is proposed to enhance the voltage support capacity of the GFL converter during grid faults. Moreover, for the distribution network with multi-converters, a compensation current control based on the analytic hierarchy process and coefficient of variation is proposed to ensure a balance between minimal capacity and optimal power quality. In this manner, DGs can be plug-and-play without considering stability and power quality issues. Finally, the effectiveness of the proposed strategy is validated with simulation results.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 6553-6558
Islanding Detection Time Calculation for Constraint Characterization in DC Microgrid
Detection time is the core indicator of the islanding detection method with positive feedback power disturbance (PFPD) for dc microgrid, which determines the speed and effectiveness of the detection. However, the PFPD-based system presents high-order characteristics due to the employment of a high-pass filter, making it hard to analyze in the time domain. The existing studies rely on the frequency domain to indirectly constrain the range of positive feedback parameters, which may make the detection speed cannot be designed accurately and even lead to detection failure. In this letter, the equivalent control model of the distributed generator is developed to reveal the limitation of the conventional frequency domain-based parameter design method. Then, the dynamics model of the voltage at the point of common coupling is analyzed and simplified to describe the time domain oscillation trajectory triggered by the islanding event. Furthermore, a detection time calculation method based on voltage envelope is proposed to constrain the islanding detection parameters, and its effectiveness and advantages are validated by experiments. This method quantitatively and intuitively characterizes the constraints of detection time on positive feedback parameters, and it provides good insight into the detection control optimization and detection speed improvement.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 6553-6558
Islanding Detection Time Calculation for Constraint Characterization in DC Microgrid
Detection time is the core indicator of the islanding detection method with positive feedback power disturbance (PFPD) for dc microgrid, which determines the speed and effectiveness of the detection. However, the PFPD-based system presents high-order characteristics due to the employment of a high-pass filter, making it hard to analyze in the time domain. The existing studies rely on the frequency domain to indirectly constrain the range of positive feedback parameters, which may make the detection speed cannot be designed accurately and even lead to detection failure. In this letter, the equivalent control model of the distributed generator is developed to reveal the limitation of the conventional frequency domain-based parameter design method. Then, the dynamics model of the voltage at the point of common coupling is analyzed and simplified to describe the time domain oscillation trajectory triggered by the islanding event. Furthermore, a detection time calculation method based on voltage envelope is proposed to constrain the islanding detection parameters, and its effectiveness and advantages are validated by experiments. This method quantitatively and intuitively characterizes the constraints of detection time on positive feedback parameters, and it provides good insight into the detection control optimization and detection speed improvement.
- 8 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (1) , 1773-1783
Stability Improvement Without External Communication for DC Microgrid Equipped With Positive Feedback Islanding Detection
Unplanned islanding events in dc microgrids bring severe safety hazards to distributed generators (DG) and consumers. The positive feedback islanding detection method (IDM) provides guaranteed protection for consumers due to its small non-detection zone and high detection speed. However, the positive feedback loop continuously injects disturbances into DG and thus will result in a reduction in the stability margin of the grid-connected dc microgrid. Conventional solutions usually provide stability compensation based on grid current in the dc/dc converter to avoid conflicts with IDM, but it requires external communication and thus reduces system reliability. To address this issue, the cascaded impedance model of the grid-connected dc system is developed first in this paper, which reveals the instability mechanism caused by the IDM. On top of that, the phase stability region of the voltage source converter (VSC) is explored and described to guide the damper design. Furthermore, an active damping method is proposed to realize phase compensation for the VSC impedance. In this manner, the negative effect of the islanding detection loop on the stability margin is effectively mitigated without external communication links. Finally, the proposed method is validated in hardware-in-loop experiments.
- 8 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (1) , 1773-1783
Stability Improvement Without External Communication for DC Microgrid Equipped With Positive Feedback Islanding Detection
Unplanned islanding events in dc microgrids bring severe safety hazards to distributed generators (DG) and consumers. The positive feedback islanding detection method (IDM) provides guaranteed protection for consumers due to its small non-detection zone and high detection speed. However, the positive feedback loop continuously injects disturbances into DG and thus will result in a reduction in the stability margin of the grid-connected dc microgrid. Conventional solutions usually provide stability compensation based on grid current in the dc/dc converter to avoid conflicts with IDM, but it requires external communication and thus reduces system reliability. To address this issue, the cascaded impedance model of the grid-connected dc system is developed first in this paper, which reveals the instability mechanism caused by the IDM. On top of that, the phase stability region of the voltage source converter (VSC) is explored and described to guide the damper design. Furthermore, an active damping method is proposed to realize phase compensation for the VSC impedance. In this manner, the negative effect of the islanding detection loop on the stability margin is effectively mitigated without external communication links. Finally, the proposed method is validated in hardware-in-loop experiments.
- 20 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 1168-1182
Power Flow Control of Bidirectional Modular Multilevel Resonant Converters in MVDC and LVDC Distribution Networks
This article proposes a bidirectional modular multilevel resonant dc converter (BMMRDC) and its power flow control strategy for medium-voltage dc to low-voltage dc distribution network First, a brief description of the BMMRDC topology structure is provided, followed by a detailed investigation of its operational principles under different operating modes. Then, the voltage gain model is studied, and the relationship between the transferred power and the operating frequency is precisely built. On this basis, a bidirectional power control strategy is proposed to adjust power flexibly by regulating the switching frequency. Furthermore, the soft-switching behaviors of the medium-voltage side and low-voltage side devices are analyzed to guide the parameter design of the converter, enabling soft-switching operation under a wide range of operating conditions. Finally, a downscaled BMMRDC prototype is constructed to validate the feasibility of the BMMRDC topology and the proposed control strategy.
- 20 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 1168-1182
Power Flow Control of Bidirectional Modular Multilevel Resonant Converters in MVDC and LVDC Distribution Networks
This article proposes a bidirectional modular multilevel resonant dc converter (BMMRDC) and its power flow control strategy for medium-voltage dc to low-voltage dc distribution network First, a brief description of the BMMRDC topology structure is provided, followed by a detailed investigation of its operational principles under different operating modes. Then, the voltage gain model is studied, and the relationship between the transferred power and the operating frequency is precisely built. On this basis, a bidirectional power control strategy is proposed to adjust power flexibly by regulating the switching frequency. Furthermore, the soft-switching behaviors of the medium-voltage side and low-voltage side devices are analyzed to guide the parameter design of the converter, enabling soft-switching operation under a wide range of operating conditions. Finally, a downscaled BMMRDC prototype is constructed to validate the feasibility of the BMMRDC topology and the proposed control strategy.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (1) , 409-421
Impedance Shaping Method for System-Level Stabilization of Droop-Controlled DC Microgrids
DC microgrids (MGs) based on distributed energy resources (DERs) are prone to stability issues due to the negative impedance characteristics of some interface converters. Large-scale MGs need to be compatible with various operation modes and integrate the DERs with different structures, thereby increasing the difficulty of stabilization design. To address this problem, this paper proposes a novel impedance shaping method to achieve system-level stabilization by designing feedback laws for the droop-controlled sources. An impedance shaping criterion is first proposed for the decoupling design of multiple droop-controlled sources. Compared with existing impedance shaping methods, the proposed criterion can be more flexibly applied to a large-scale DC MG. An efficient algorithm is further developed to design the primary droop control by combining the proposed criterion and linear matrix inequalities. The proposed method features a simpler control architecture and can be directly applied to the DERs with different interface converters. Case study based on experiment and benchmark system shows that the DC MG designed by the proposed method has a high stability margin and good transient performance.
- 15 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (1) , 409-421
Impedance Shaping Method for System-Level Stabilization of Droop-Controlled DC Microgrids
DC microgrids (MGs) based on distributed energy resources (DERs) are prone to stability issues due to the negative impedance characteristics of some interface converters. Large-scale MGs need to be compatible with various operation modes and integrate the DERs with different structures, thereby increasing the difficulty of stabilization design. To address this problem, this paper proposes a novel impedance shaping method to achieve system-level stabilization by designing feedback laws for the droop-controlled sources. An impedance shaping criterion is first proposed for the decoupling design of multiple droop-controlled sources. Compared with existing impedance shaping methods, the proposed criterion can be more flexibly applied to a large-scale DC MG. An efficient algorithm is further developed to design the primary droop control by combining the proposed criterion and linear matrix inequalities. The proposed method features a simpler control architecture and can be directly applied to the DERs with different interface converters. Case study based on experiment and benchmark system shows that the DC MG designed by the proposed method has a high stability margin and good transient performance.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (6) , 5388-5401
Parameter Boundary Characterization for DC Microgrid Islanding Detection Based on Time-Domain Voltage Oscillation Trajectory Analysis
Unintentional islanding events cause potential threats to the safety of dc microgrids. Selected frequency islanding detection is considered a promising technology thanks to its good power quality and high detection accuracy. However, the conventional frequency-domain-based islanding detection parameter boundary cannot consider the impact of detection time, which causes a quite slow detection speed and thus leads to detection failure. To overcome this obstacle, a linear model of the islanding dc system is developed first to analyze the steady-state response of the voltage at the point of common coupling (PCC). On top of that, the components of the islanding system characteristic equation are analyzed based on modal analysis, which lays a good foundation for simplifying the time-domain response model of the PCC voltage. Then, the oscillation trajectory of the PCC voltage triggered by the islanding event is characterized in the time domain, which facilitates the analysis and calculation of islanding detection time. Furthermore, the boundary of the islanding detection parameters considering the detection time effect is accurately depicted to guide the resonator design. In this manner, the effect of resonant parameters on the detection time can be evaluated visually while the fast detection speed is also ensured. Finally, the proposed method is validated in simulations and hardware-in-loop experiments.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (6) , 5388-5401
Parameter Boundary Characterization for DC Microgrid Islanding Detection Based on Time-Domain Voltage Oscillation Trajectory Analysis
Unintentional islanding events cause potential threats to the safety of dc microgrids. Selected frequency islanding detection is considered a promising technology thanks to its good power quality and high detection accuracy. However, the conventional frequency-domain-based islanding detection parameter boundary cannot consider the impact of detection time, which causes a quite slow detection speed and thus leads to detection failure. To overcome this obstacle, a linear model of the islanding dc system is developed first to analyze the steady-state response of the voltage at the point of common coupling (PCC). On top of that, the components of the islanding system characteristic equation are analyzed based on modal analysis, which lays a good foundation for simplifying the time-domain response model of the PCC voltage. Then, the oscillation trajectory of the PCC voltage triggered by the islanding event is characterized in the time domain, which facilitates the analysis and calculation of islanding detection time. Furthermore, the boundary of the islanding detection parameters considering the detection time effect is accurately depicted to guide the resonator design. In this manner, the effect of resonant parameters on the detection time can be evaluated visually while the fast detection speed is also ensured. Finally, the proposed method is validated in simulations and hardware-in-loop experiments.