Boxin Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Boxin Liu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Xin Xiang
Zhejiang University
16 shared publications - Wuhua Li
Zhejiang University
14 shared publications - Tianling Shi
School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
9 shared publications - Xiangning He
Zhejiang University
9 shared publications - Jintao Lei
College of Electrical Engineering, Zhejiang University, Hangzhou, China
8 shared publications - Fei Wang
Shanghai University
7 shared publications
Latest Publications
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (8) , 11538-11550
Transient Overcurrent Suppression in Fault Recovery Stage for Grid Forming Converter Based on Postfault Active Angle Control
The grid forming (GFM) converter may undesirably output a higher postfault current than the fault duration current, which would cause it to face the severe risk of overcurrent or even damage after the grid fault has already been cleared. The existing methods mainly focus on the fault duration current limitation, while the tailored strategy for transient overcurrent suppression in the fault recovery stage is still missing. This article describes the analytical relationship between transient current and grid voltage considering power angle swing effect in GFM converter. On this basis, it reveals that the grid voltage recovery under a significant power angle value is the root cause of the recovery overcurrent (ROC) phenomenon. To solve this issue, a postfault active angle control (PAAC) strategy is proposed and designed without the need for additional fault grid detection methods. This strategy may help the GFM converter effectively avoid the ROC problem by reshaping the power angle trajectory at the fault recovery stage without compromising resynchronization capability with the postfault grid. Furthermore, the effect of parameters in PAAC control is assessed analytically, and its design criteria are also discussed in detail. Finally, the correctness of the theoretical analysis and the feasibility of the PAAC strategy are both verified in the experimental tests.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (8) , 11538-11550
Transient Overcurrent Suppression in Fault Recovery Stage for Grid Forming Converter Based on Postfault Active Angle Control
The grid forming (GFM) converter may undesirably output a higher postfault current than the fault duration current, which would cause it to face the severe risk of overcurrent or even damage after the grid fault has already been cleared. The existing methods mainly focus on the fault duration current limitation, while the tailored strategy for transient overcurrent suppression in the fault recovery stage is still missing. This article describes the analytical relationship between transient current and grid voltage considering power angle swing effect in GFM converter. On this basis, it reveals that the grid voltage recovery under a significant power angle value is the root cause of the recovery overcurrent (ROC) phenomenon. To solve this issue, a postfault active angle control (PAAC) strategy is proposed and designed without the need for additional fault grid detection methods. This strategy may help the GFM converter effectively avoid the ROC problem by reshaping the power angle trajectory at the fault recovery stage without compromising resynchronization capability with the postfault grid. Furthermore, the effect of parameters in PAAC control is assessed analytically, and its design criteria are also discussed in detail. Finally, the correctness of the theoretical analysis and the feasibility of the PAAC strategy are both verified in the experimental tests.
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 5013-5018
Fault Inrush Current Characterization of Grid Forming Converter Based on Analytical Calculation
The fault inrush current (FIC) characterization, which focuses on the current transition process at grid fault occurs, is vital for the control and protection of grid forming (GFM) converter system. However, the existing FIC analysis usually oversimplifies the electromagnetic transient (EMT) interactions and mainly relies on numerical iterations. The negligence of the quantitative relationship between FIC and control parameters brings difficulties in FIC suppression and system protection. To fill the gap, this article establishes a tailored EMT model that considers the dominating interactions of cascaded control and passive components. On this basis, the response of FIC under grid fault is analytically calculated in time domain and the impact of control parameters on FIC attenuation is also depicted. It would provide reference on control configuration and protection threshold settings for GFM converter system. The theoretical analysis is well validated by a series of experiments.
- 5 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 5013-5018
Fault Inrush Current Characterization of Grid Forming Converter Based on Analytical Calculation
The fault inrush current (FIC) characterization, which focuses on the current transition process at grid fault occurs, is vital for the control and protection of grid forming (GFM) converter system. However, the existing FIC analysis usually oversimplifies the electromagnetic transient (EMT) interactions and mainly relies on numerical iterations. The negligence of the quantitative relationship between FIC and control parameters brings difficulties in FIC suppression and system protection. To fill the gap, this article establishes a tailored EMT model that considers the dominating interactions of cascaded control and passive components. On this basis, the response of FIC under grid fault is analytically calculated in time domain and the impact of control parameters on FIC attenuation is also depicted. It would provide reference on control configuration and protection threshold settings for GFM converter system. The theoretical analysis is well validated by a series of experiments.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 6553-6558
Islanding Detection Time Calculation for Constraint Characterization in DC Microgrid
Detection time is the core indicator of the islanding detection method with positive feedback power disturbance (PFPD) for dc microgrid, which determines the speed and effectiveness of the detection. However, the PFPD-based system presents high-order characteristics due to the employment of a high-pass filter, making it hard to analyze in the time domain. The existing studies rely on the frequency domain to indirectly constrain the range of positive feedback parameters, which may make the detection speed cannot be designed accurately and even lead to detection failure. In this letter, the equivalent control model of the distributed generator is developed to reveal the limitation of the conventional frequency domain-based parameter design method. Then, the dynamics model of the voltage at the point of common coupling is analyzed and simplified to describe the time domain oscillation trajectory triggered by the islanding event. Furthermore, a detection time calculation method based on voltage envelope is proposed to constrain the islanding detection parameters, and its effectiveness and advantages are validated by experiments. This method quantitatively and intuitively characterizes the constraints of detection time on positive feedback parameters, and it provides good insight into the detection control optimization and detection speed improvement.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (6) , 6553-6558
Islanding Detection Time Calculation for Constraint Characterization in DC Microgrid
Detection time is the core indicator of the islanding detection method with positive feedback power disturbance (PFPD) for dc microgrid, which determines the speed and effectiveness of the detection. However, the PFPD-based system presents high-order characteristics due to the employment of a high-pass filter, making it hard to analyze in the time domain. The existing studies rely on the frequency domain to indirectly constrain the range of positive feedback parameters, which may make the detection speed cannot be designed accurately and even lead to detection failure. In this letter, the equivalent control model of the distributed generator is developed to reveal the limitation of the conventional frequency domain-based parameter design method. Then, the dynamics model of the voltage at the point of common coupling is analyzed and simplified to describe the time domain oscillation trajectory triggered by the islanding event. Furthermore, a detection time calculation method based on voltage envelope is proposed to constrain the islanding detection parameters, and its effectiveness and advantages are validated by experiments. This method quantitatively and intuitively characterizes the constraints of detection time on positive feedback parameters, and it provides good insight into the detection control optimization and detection speed improvement.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 2987-3004
Stability Constrained Transient Overcurrent Capability Enhancement of Grid Forming Converters Based on Switching Frequency Adjustment
The short-term overcurrent capability is critical for grid forming (GFM) converters to provide support during grid fault transient. Although the transient overcurrent (TOC) capability enhancement strategy based on customized and oversized design for power converters has developed in recent studies, these solutions are still difficult to promote due to their high cost and complex hardware structures. To address this issue, this article introduces the switching frequency as the degree of freedom to improve the TOC capability of GFM converter at the software level. By actively reducing the switching frequency in the TOC stage, the rise in junction temperature caused by overrated current can be suppressed effectively. Moreover, the inherent control stability issue of the inner voltage vector control loop under the substantial decrease of the switching frequency is quantitatively studied. On this basis, a multiparameters coregulation strategy is further proposed to ensure sufficient stability margin of the control loop during the TOC stage with the decreasing switching frequency. This strategy solves the contradiction between control stability and thermal demands in the switching frequency-based TOC method and it can further enhance the TOC capability without redesigning the hardware. Finally, the proposed TOC capability enhancement strategy is verified in both the electrothermal simulation and experiment.
- 30 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (2) , 2987-3004
Stability Constrained Transient Overcurrent Capability Enhancement of Grid Forming Converters Based on Switching Frequency Adjustment
The short-term overcurrent capability is critical for grid forming (GFM) converters to provide support during grid fault transient. Although the transient overcurrent (TOC) capability enhancement strategy based on customized and oversized design for power converters has developed in recent studies, these solutions are still difficult to promote due to their high cost and complex hardware structures. To address this issue, this article introduces the switching frequency as the degree of freedom to improve the TOC capability of GFM converter at the software level. By actively reducing the switching frequency in the TOC stage, the rise in junction temperature caused by overrated current can be suppressed effectively. Moreover, the inherent control stability issue of the inner voltage vector control loop under the substantial decrease of the switching frequency is quantitatively studied. On this basis, a multiparameters coregulation strategy is further proposed to ensure sufficient stability margin of the control loop during the TOC stage with the decreasing switching frequency. This strategy solves the contradiction between control stability and thermal demands in the switching frequency-based TOC method and it can further enhance the TOC capability without redesigning the hardware. Finally, the proposed TOC capability enhancement strategy is verified in both the electrothermal simulation and experiment.
- 8 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (1) , 1773-1783
Stability Improvement Without External Communication for DC Microgrid Equipped With Positive Feedback Islanding Detection
Unplanned islanding events in dc microgrids bring severe safety hazards to distributed generators (DG) and consumers. The positive feedback islanding detection method (IDM) provides guaranteed protection for consumers due to its small non-detection zone and high detection speed. However, the positive feedback loop continuously injects disturbances into DG and thus will result in a reduction in the stability margin of the grid-connected dc microgrid. Conventional solutions usually provide stability compensation based on grid current in the dc/dc converter to avoid conflicts with IDM, but it requires external communication and thus reduces system reliability. To address this issue, the cascaded impedance model of the grid-connected dc system is developed first in this paper, which reveals the instability mechanism caused by the IDM. On top of that, the phase stability region of the voltage source converter (VSC) is explored and described to guide the damper design. Furthermore, an active damping method is proposed to realize phase compensation for the VSC impedance. In this manner, the negative effect of the islanding detection loop on the stability margin is effectively mitigated without external communication links. Finally, the proposed method is validated in hardware-in-loop experiments.
- 8 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Consumer Electronics
- Vol. 71 (1) , 1773-1783
Stability Improvement Without External Communication for DC Microgrid Equipped With Positive Feedback Islanding Detection
Unplanned islanding events in dc microgrids bring severe safety hazards to distributed generators (DG) and consumers. The positive feedback islanding detection method (IDM) provides guaranteed protection for consumers due to its small non-detection zone and high detection speed. However, the positive feedback loop continuously injects disturbances into DG and thus will result in a reduction in the stability margin of the grid-connected dc microgrid. Conventional solutions usually provide stability compensation based on grid current in the dc/dc converter to avoid conflicts with IDM, but it requires external communication and thus reduces system reliability. To address this issue, the cascaded impedance model of the grid-connected dc system is developed first in this paper, which reveals the instability mechanism caused by the IDM. On top of that, the phase stability region of the voltage source converter (VSC) is explored and described to guide the damper design. Furthermore, an active damping method is proposed to realize phase compensation for the VSC impedance. In this manner, the negative effect of the islanding detection loop on the stability margin is effectively mitigated without external communication links. Finally, the proposed method is validated in hardware-in-loop experiments.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (6) , 5388-5401
Parameter Boundary Characterization for DC Microgrid Islanding Detection Based on Time-Domain Voltage Oscillation Trajectory Analysis
Unintentional islanding events cause potential threats to the safety of dc microgrids. Selected frequency islanding detection is considered a promising technology thanks to its good power quality and high detection accuracy. However, the conventional frequency-domain-based islanding detection parameter boundary cannot consider the impact of detection time, which causes a quite slow detection speed and thus leads to detection failure. To overcome this obstacle, a linear model of the islanding dc system is developed first to analyze the steady-state response of the voltage at the point of common coupling (PCC). On top of that, the components of the islanding system characteristic equation are analyzed based on modal analysis, which lays a good foundation for simplifying the time-domain response model of the PCC voltage. Then, the oscillation trajectory of the PCC voltage triggered by the islanding event is characterized in the time domain, which facilitates the analysis and calculation of islanding detection time. Furthermore, the boundary of the islanding detection parameters considering the detection time effect is accurately depicted to guide the resonator design. In this manner, the effect of resonant parameters on the detection time can be evaluated visually while the fast detection speed is also ensured. Finally, the proposed method is validated in simulations and hardware-in-loop experiments.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (6) , 5388-5401
Parameter Boundary Characterization for DC Microgrid Islanding Detection Based on Time-Domain Voltage Oscillation Trajectory Analysis
Unintentional islanding events cause potential threats to the safety of dc microgrids. Selected frequency islanding detection is considered a promising technology thanks to its good power quality and high detection accuracy. However, the conventional frequency-domain-based islanding detection parameter boundary cannot consider the impact of detection time, which causes a quite slow detection speed and thus leads to detection failure. To overcome this obstacle, a linear model of the islanding dc system is developed first to analyze the steady-state response of the voltage at the point of common coupling (PCC). On top of that, the components of the islanding system characteristic equation are analyzed based on modal analysis, which lays a good foundation for simplifying the time-domain response model of the PCC voltage. Then, the oscillation trajectory of the PCC voltage triggered by the islanding event is characterized in the time domain, which facilitates the analysis and calculation of islanding detection time. Furthermore, the boundary of the islanding detection parameters considering the detection time effect is accurately depicted to guide the resonator design. In this manner, the effect of resonant parameters on the detection time can be evaluated visually while the fast detection speed is also ensured. Finally, the proposed method is validated in simulations and hardware-in-loop experiments.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 12163-12169
On the Transient Overcurrent Mechanism of Grid Forming Converter in Fault Recovery Stage
The grid forming (GFM) converter may undesirably output a higher current during the recovery stage than fault duration due to its transient angle swing, which would cause the power devices to face the risk of overcurrent or even damage in both the fault stage and the recovery stage. In this letter, the current power angle plane is presented for the current trajectory description and the mechanism of the recovery overcurrent (ROC) issue is revealed through the proposed concept of critical recovery angle (CRA). On top of that, the power angle relationship in the critical ROC state is described in detail and the ROC boundary is further characterized accurately. Moreover, an analytical calculation method of CRA is proposed to identify whether the ROC phenomenon occurs, which is well validated by a series of experiments. The proposed method depicts the inherent relationship between the current behavior and power angle motion of GFM converters quantitatively and intuitively, and it may provide some new insights into the transient analysis and control optimization of GFM converters.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 12163-12169
On the Transient Overcurrent Mechanism of Grid Forming Converter in Fault Recovery Stage
The grid forming (GFM) converter may undesirably output a higher current during the recovery stage than fault duration due to its transient angle swing, which would cause the power devices to face the risk of overcurrent or even damage in both the fault stage and the recovery stage. In this letter, the current power angle plane is presented for the current trajectory description and the mechanism of the recovery overcurrent (ROC) issue is revealed through the proposed concept of critical recovery angle (CRA). On top of that, the power angle relationship in the critical ROC state is described in detail and the ROC boundary is further characterized accurately. Moreover, an analytical calculation method of CRA is proposed to identify whether the ROC phenomenon occurs, which is well validated by a series of experiments. The proposed method depicts the inherent relationship between the current behavior and power angle motion of GFM converters quantitatively and intuitively, and it may provide some new insights into the transient analysis and control optimization of GFM converters.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (10) , 12290-12300
Communication-Less Active Damping Method With VSC for Stability Improvement of Grid-Connected DC Microgrid With Selected Frequency Islanding Detection
The islanding detection method (IDM) with current disturbance of selected frequency (CDSF) in dc microgrids is gaining extensive attention thanks to its small nondetection zone and good power quality. However, the CDSF is implemented through a positive feedback loop and thus will lead to instability issues for the dc microgrid even in the grid-connected mode. Conventional stabilization control is generally employed on the distributed generator (DG) side and usually requires an additional uninterrupted communication process, which therefore decreases system reliability. In this article, the impedance model of the dc microgrid is established first to reveal the interaction instability mechanism between the voltage source converter (VSC) and DG equipped with CDSF IDM. On top of that, the notch-filter-based active damping method is proposed on the VSC side to avoid amplitude intersection of impedance near the selected resonant frequency, which effectively mitigates the instability caused by the islanding detection loop without relying on communication. Moreover, the parameter design method is further summarized to provide guidance for the selection of notch bandwidth in the proposed damper. In this manner, the stability of the grid-connected system can be improved while the islanding detecting speed is enhanced. In the end, the effectiveness of the proposed stabilizing method is verified by the experiments.
- 15 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (10) , 12290-12300
Communication-Less Active Damping Method With VSC for Stability Improvement of Grid-Connected DC Microgrid With Selected Frequency Islanding Detection
The islanding detection method (IDM) with current disturbance of selected frequency (CDSF) in dc microgrids is gaining extensive attention thanks to its small nondetection zone and good power quality. However, the CDSF is implemented through a positive feedback loop and thus will lead to instability issues for the dc microgrid even in the grid-connected mode. Conventional stabilization control is generally employed on the distributed generator (DG) side and usually requires an additional uninterrupted communication process, which therefore decreases system reliability. In this article, the impedance model of the dc microgrid is established first to reveal the interaction instability mechanism between the voltage source converter (VSC) and DG equipped with CDSF IDM. On top of that, the notch-filter-based active damping method is proposed on the VSC side to avoid amplitude intersection of impedance near the selected resonant frequency, which effectively mitigates the instability caused by the islanding detection loop without relying on communication. Moreover, the parameter design method is further summarized to provide guidance for the selection of notch bandwidth in the proposed damper. In this manner, the stability of the grid-connected system can be improved while the islanding detecting speed is enhanced. In the end, the effectiveness of the proposed stabilizing method is verified by the experiments.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1564-1568
Detection Threshold Design for DC Islanding Detection with Static Disturbing Frequency
Anti-islanding approach with current perturbation of particular frequency in dc microgrids has attracted wide attention in recent years. Nevertheless, the static perturbation frequency selected from the rated conditions shifts with system power variation, and thus will lead to a detection failure. In this article, the function of current perturbation to the output voltage of distributed generations is derived to illustrate the root cause of the frequency shift problem. On top of that, the design method of detection threshold is proposed to ensure successful detection. At last, the effectiveness and accuracy of the detection threshold design method is proved by the simulations.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1564-1568
Detection Threshold Design for DC Islanding Detection with Static Disturbing Frequency
Anti-islanding approach with current perturbation of particular frequency in dc microgrids has attracted wide attention in recent years. Nevertheless, the static perturbation frequency selected from the rated conditions shifts with system power variation, and thus will lead to a detection failure. In this article, the function of current perturbation to the output voltage of distributed generations is derived to illustrate the root cause of the frequency shift problem. On top of that, the design method of detection threshold is proposed to ensure successful detection. At last, the effectiveness and accuracy of the detection threshold design method is proved by the simulations.