Hironori Suzuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hironori Suzuki has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Amrita Kumar Sana
Hiroshima University
2 shared publications - Eslam Abubakr
Department of Mechanical Engineering and Intelligent Systems, Graduate School of Informatics and Engineering, The University of Electro-Communications, Tokyo, Japan
2 shared publications - Hideki Shibata
Department of Applied Biosciences, Graduate School of Bioagricultural Sciences, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan
2 shared publications Hidemi Kato
IMRA Japan Co., Ltd., 2-36, Hachiken-cho, Kariya, Japan
2 shared publications- Hiroaki Misawa
Hokkaido University
2 shared publications Koki Hayashi
IMRA Japan Co., Ltd., 2-36, Hachiken-cho, Kariya, Japan
2 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (11) , 658
Filter-Array-Free Broadband NIR Reconstructive Spectroscopy via a Titanium-Engineered Self-Powered Plasmonic Photodetector
Conventional gas sensors suffer from poor selectivity, high operating temperatures, or reliance on bulky spectrometers and cooled infrared detectors, limiting compact, real-time analysis. Plasmon-induced hot-electron injection across a metal/semiconductor junction offers a route to sub-bandgap photodetection without an external bias. Here, we demonstrate an angle-resolved, filter-array-free near-infrared (NIR) reconstructive spectroscopy approach based on a single embedded-grating plasmonic photodetector. Gold supports the grating-coupled surface plasmon resonance, while a thin Ti interlayer improves the interface and yields an effective Schottky barrier height of 0.506 eV, enabling internal photoemission below the silicon bandgap. An embedded grating, formed by directly grooving the silicon surface, increases the metal/semiconductor interfacial area available for hot-electron injection. Zero-bias responsivities of 4 mA/W at 1200 nm and 0.62 mA/W at 1600 nm were measured, and resonant photoresponse was additionally observed up to 2.4 µm with high spectral selectivity. Using a measured angle–wavelength responsivity matrix, high-fidelity spectral reconstruction comparable to that of commercial Fourier-transform infrared spectrometers was demonstrated at room temperature. In the present demonstration, the detector chip requires no filter array, with high potential for compact NIR spectroscopic sensors and gas monitoring applications.
- 17 November 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (11) , 658
Open AccessFilter-Array-Free Broadband NIR Reconstructive Spectroscopy via a Titanium-Engineered Self-Powered Plasmonic Photodetector
Conventional gas sensors suffer from poor selectivity, high operating temperatures, or reliance on bulky spectrometers and cooled infrared detectors, limiting compact, real-time analysis. Plasmon-induced hot-electron injection across a metal/semiconductor junction offers a route to sub-bandgap photodetection without an external bias. Here, we demonstrate an angle-resolved, filter-array-free near-infrared (NIR) reconstructive spectroscopy approach based on a single embedded-grating plasmonic photodetector. Gold supports the grating-coupled surface plasmon resonance, while a thin Ti interlayer improves the interface and yields an effective Schottky barrier height of 0.506 eV, enabling internal photoemission below the silicon bandgap. An embedded grating, formed by directly grooving the silicon surface, increases the metal/semiconductor interfacial area available for hot-electron injection. Zero-bias responsivities of 4 mA/W at 1200 nm and 0.62 mA/W at 1600 nm were measured, and resonant photoresponse was additionally observed up to 2.4 µm with high spectral selectivity. Using a measured angle–wavelength responsivity matrix, high-fidelity spectral reconstruction comparable to that of commercial Fourier-transform infrared spectrometers was demonstrated at room temperature. In the present demonstration, the detector chip requires no filter array, with high potential for compact NIR spectroscopic sensors and gas monitoring applications.
- Open Access
In Silico Exfoliation of ReaxFF Graphite—Temperature, Speed, Angle Dependence, and the Effect of Gold Overlayer
Exfoliation of layered materials is an important technique for preparing atomic-layer materials. To provide fundamental mechanistic insights for optimizing this process, we investigated the exfoliation process of nano graphite using molecular dynamics simulations with the ReaxFF force field. The impact of temperature, speed, and angle of removing the top layer has been examined to gain insight into obtaining thin, uniform layers. The bending rigidity of the ReaxFF graphite is temperature-dependent and affects the cleavage behavior. The impact of the Au overlayer, which has recently been utilized to obtain a large area, was also studied, and it was confirmed to be effective in improving repeatability.
Open AccessIn Silico Exfoliation of ReaxFF Graphite—Temperature, Speed, Angle Dependence, and the Effect of Gold Overlayer
Exfoliation of layered materials is an important technique for preparing atomic-layer materials. To provide fundamental mechanistic insights for optimizing this process, we investigated the exfoliation process of nano graphite using molecular dynamics simulations with the ReaxFF force field. The impact of temperature, speed, and angle of removing the top layer has been examined to gain insight into obtaining thin, uniform layers. The bending rigidity of the ReaxFF graphite is temperature-dependent and affects the cleavage behavior. The impact of the Au overlayer, which has recently been utilized to obtain a large area, was also studied, and it was confirmed to be effective in improving repeatability.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (1) , 301-305
Advanced Room-Temperature NIR Plasmonic Photodetection and Reconstructive Spectroscopy
While Au is commonly utilized in semiconductor fabrication, its interaction with Si yields unstable contacts, posing potential reliability concerns. In this work, Cr interlayers were integrated to improve interface properties, enhance charge carrier transport within a plasmonic photodetector, and ensure long-term stability, demonstrated by consistent responses under zero bias and room-temperature conditions over the span of a year. The induced Fermi level shifts and Schottky barrier lowering to 0.59 eV, improving responsivity and extending the operation range beyond 1850 nm with increased sensitivity, allowing for precise reconstructive spectroscopy (RS). This is promising for reliable compound identification based on specific bond absorbance properties while scaling down IR spectroscopy to chip level, promoting applications like environmental monitoring and gas detection.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (1) , 301-305
Advanced Room-Temperature NIR Plasmonic Photodetection and Reconstructive Spectroscopy
While Au is commonly utilized in semiconductor fabrication, its interaction with Si yields unstable contacts, posing potential reliability concerns. In this work, Cr interlayers were integrated to improve interface properties, enhance charge carrier transport within a plasmonic photodetector, and ensure long-term stability, demonstrated by consistent responses under zero bias and room-temperature conditions over the span of a year. The induced Fermi level shifts and Schottky barrier lowering to 0.59 eV, improving responsivity and extending the operation range beyond 1850 nm with increased sensitivity, allowing for precise reconstructive spectroscopy (RS). This is promising for reliable compound identification based on specific bond absorbance properties while scaling down IR spectroscopy to chip level, promoting applications like environmental monitoring and gas detection.
- Open Access
- 10 November 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-7
A Fabry-Pérot cavity coupled surface plasmon photodiode for electrical biomolecular sensing
Surface plasmon resonance is a well-established technology for real-time highly sensitive label-free detection and measurement of binding kinetics between biological samples. A common drawback, however, of surface plasmon resonance detection is the necessity for far field angular resolved measurement of specular reflection, which increases the size as well as requiring precise calibration of the optical apparatus. Here we present an alternative optoelectronic approach in which the plasmonic sensor is integrated within a photovoltaic cell. Incident light generates an electronic signal that is sensitive to the refractive index of a solution via interaction with the plasmon. The photogenerated current is enhanced due to the coupling of the plasmon mode with Fabry-Pérot modes in the absorbing layer of the photovoltaic cell. The near field electrical detection of surface plasmon resonance we demonstrate will enable a next generation of cheap, compact and high throughput biosensors.
- 10 November 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-7
Open AccessA Fabry-Pérot cavity coupled surface plasmon photodiode for electrical biomolecular sensing
Surface plasmon resonance is a well-established technology for real-time highly sensitive label-free detection and measurement of binding kinetics between biological samples. A common drawback, however, of surface plasmon resonance detection is the necessity for far field angular resolved measurement of specular reflection, which increases the size as well as requiring precise calibration of the optical apparatus. Here we present an alternative optoelectronic approach in which the plasmonic sensor is integrated within a photovoltaic cell. Incident light generates an electronic signal that is sensitive to the refractive index of a solution via interaction with the plasmon. The photogenerated current is enhanced due to the coupling of the plasmon mode with Fabry-Pérot modes in the absorbing layer of the photovoltaic cell. The near field electrical detection of surface plasmon resonance we demonstrate will enable a next generation of cheap, compact and high throughput biosensors.
- Open Access
- 15 April 2021
- Published by Springer Nature in Research Square
A Fabry-Pérot cavity coupled surface plasmon photodiode for electrical biomolecular sensing
Surface plasmon resonance (SPR) is a well-established technology for real-time highly sensitive label-free detection and measurement of binding kinetics between biological samples. A common drawback, however, of SPR detection is the necessity for far field angular resolved measurement of specular reflection, which increases the size as well as requiring precise calibration of the optical apparatus. Here we present an alternative optoelectronic approach in which the plasmonic sensor is integrated within a photovoltaic cell. Incident light generates an electronic signal that is sensitive to the refractive index (RI) of a solution via interaction with the plasmon. The photogenerated current is enhanced due to the coupling of the plasmon mode with Fabry-Pérot (FP) modes in the absorbing layer of the photovoltaic cell. The near field electrical detection of SPR we demonstrate will enable a new generation of cheap, compact and high throughput biosensors.
- 15 April 2021
- Published by Springer Nature in Research Square
Open AccessA Fabry-Pérot cavity coupled surface plasmon photodiode for electrical biomolecular sensing
Surface plasmon resonance (SPR) is a well-established technology for real-time highly sensitive label-free detection and measurement of binding kinetics between biological samples. A common drawback, however, of SPR detection is the necessity for far field angular resolved measurement of specular reflection, which increases the size as well as requiring precise calibration of the optical apparatus. Here we present an alternative optoelectronic approach in which the plasmonic sensor is integrated within a photovoltaic cell. Incident light generates an electronic signal that is sensitive to the refractive index (RI) of a solution via interaction with the plasmon. The photogenerated current is enhanced due to the coupling of the plasmon mode with Fabry-Pérot (FP) modes in the absorbing layer of the photovoltaic cell. The near field electrical detection of SPR we demonstrate will enable a new generation of cheap, compact and high throughput biosensors.
- Open Access
- 18 June 2012
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 13 (6) , 7532-7549
Prediction of a New Ligand-Binding Site for Type 2 Motif based on the Crystal Structure of ALG-2 by Dry and Wet Approaches
ALG-2 is a penta-EF-hand Ca2+-binding protein and interacts with a variety of intracellular proteins. Two types of ALG-2-binding motifs have been determined: type 1, PXYPXnYP (X, variable; n = 4), in ALIX and PLSCR3; type 2, PXPGF, in Sec31A and PLSCR3. The previously solved X-ray crystal structure of the complex between ALG-2 and an ALIX peptide containing type 1 motif showed that the peptide binds to Pocket 1 and Pocket 2. Co-crystallization of ALG-2 and type 2 motif-containing peptides has not been successful. To gain insights into the molecular basis of type 2 motif recognition, we searched for a new hydrophobic cavity by computational algorithms using MetaPocket 2.0 based on 3D structures of ALG-2. The predicted hydrophobic pocket designated Pocket 3 fits with N-acetyl-ProAlaProGlyPhe-amide, a virtual penta-peptide derived from one of the two types of ALG-2-binding sites in PLSCR3 (type 2 motif), using the molecular docking software AutoDock Vina. We investigated effects of amino acid substitutions of the predicted binding sites on binding abilities by pulldown assays using glutathione-S-transferase -fused ALG-2 of wild-type and mutant proteins and lysates of cells expressing green fluorescent protein -fused PLSCR3 of wild-type and mutants. Substitution of either L52 with Ala or F148 with Ser of ALG-2 caused loss of binding abilities to PLSCR3 lacking type 1 motif but retained those to PLSCR3 lacking type 2 motif, strongly supporting the hypothesis that Pocket 3 is the binding site for type 2 motif.
- 18 June 2012
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 13 (6) , 7532-7549
Open AccessPrediction of a New Ligand-Binding Site for Type 2 Motif based on the Crystal Structure of ALG-2 by Dry and Wet Approaches
ALG-2 is a penta-EF-hand Ca2+-binding protein and interacts with a variety of intracellular proteins. Two types of ALG-2-binding motifs have been determined: type 1, PXYPXnYP (X, variable; n = 4), in ALIX and PLSCR3; type 2, PXPGF, in Sec31A and PLSCR3. The previously solved X-ray crystal structure of the complex between ALG-2 and an ALIX peptide containing type 1 motif showed that the peptide binds to Pocket 1 and Pocket 2. Co-crystallization of ALG-2 and type 2 motif-containing peptides has not been successful. To gain insights into the molecular basis of type 2 motif recognition, we searched for a new hydrophobic cavity by computational algorithms using MetaPocket 2.0 based on 3D structures of ALG-2. The predicted hydrophobic pocket designated Pocket 3 fits with N-acetyl-ProAlaProGlyPhe-amide, a virtual penta-peptide derived from one of the two types of ALG-2-binding sites in PLSCR3 (type 2 motif), using the molecular docking software AutoDock Vina. We investigated effects of amino acid substitutions of the predicted binding sites on binding abilities by pulldown assays using glutathione-S-transferase -fused ALG-2 of wild-type and mutant proteins and lysates of cells expressing green fluorescent protein -fused PLSCR3 of wild-type and mutants. Substitution of either L52 with Ala or F148 with Ser of ALG-2 caused loss of binding abilities to PLSCR3 lacking type 1 motif but retained those to PLSCR3 lacking type 2 motif, strongly supporting the hypothesis that Pocket 3 is the binding site for type 2 motif.
- Open Access
- 6 August 2010
- Published by Springer Nature in BMC Structural Biology
- Vol. 10 (1) , 25
Molecular basis for defect in Alix-binding by alternatively spliced isoform of ALG-2 (ALG-2ΔGF122) and structural roles of F122 in target recognition
Background: ALG-2 (a gene product of PDCD6) belongs to the penta-EF-hand (PEF) protein family and Ca2+-dependently interacts with various intracellular proteins including mammalian Alix, an adaptor protein in the ESCRT system. Our previous X-ray crystal structural analyses revealed that binding of Ca2+ to EF3 enables the side chain of R125 to move enough to make a primary hydrophobic pocket (Pocket 1) accessible to a short fragment of Alix. The side chain of F122, facing a secondary hydrophobic pocket (Pocket 2), interacts with the Alix peptide. An alternatively spliced shorter isoform, designated ALG-2ΔGF122, lacks Gly121Phe122 and does not bind Alix, but the structural basis of the incompetence has remained to be elucidated. Results: We solved the X-ray crystal structure of the PEF domain of ALG-2ΔGF122 in the Ca2+-bound form and compared it with that of ALG-2. Deletion of the two residues shortened α-helix 5 (α5) and changed the configuration of the R125 side chain so that it partially blocked Pocket 1. A wall created by the main chain of 121-GFG-123 and facing the two pockets was destroyed. Surprisingly, however, substitution of F122 with Ala or Gly, but not with Trp, increased the Alix-binding capacity in binding assays. The F122 substitutions exhibited different effects on binding of ALG-2 to other known interacting proteins, including TSG101 (Tumor susceptibility gene 101) and annexin A11. The X-ray crystal structure of the F122A mutant revealed that removal of the bulky F122 side chain not only created an additional open space in Pocket 2 but also abolished inter-helix interactions with W95 and V98 (present in α4) and that α5 inclined away from α4 to expand Pocket 2, suggesting acquirement of more appropriate positioning of the interacting residues to accept Alix. Conclusions: We found that the inability of the two-residue shorter ALG-2 isoform to bind Alix is not due to the absence of bulky side chain of F122 but due to deformation of a main-chain wall facing pockets 1 and 2. Moreover, a residue at the position of F122 contributes to target specificity and a smaller side chain is preferable for Alix binding but not favored to bind annexin A11.
- 6 August 2010
- Published by Springer Nature in BMC Structural Biology
- Vol. 10 (1) , 25
Open AccessMolecular basis for defect in Alix-binding by alternatively spliced isoform of ALG-2 (ALG-2ΔGF122) and structural roles of F122 in target recognition
Background: ALG-2 (a gene product of PDCD6) belongs to the penta-EF-hand (PEF) protein family and Ca2+-dependently interacts with various intracellular proteins including mammalian Alix, an adaptor protein in the ESCRT system. Our previous X-ray crystal structural analyses revealed that binding of Ca2+ to EF3 enables the side chain of R125 to move enough to make a primary hydrophobic pocket (Pocket 1) accessible to a short fragment of Alix. The side chain of F122, facing a secondary hydrophobic pocket (Pocket 2), interacts with the Alix peptide. An alternatively spliced shorter isoform, designated ALG-2ΔGF122, lacks Gly121Phe122 and does not bind Alix, but the structural basis of the incompetence has remained to be elucidated. Results: We solved the X-ray crystal structure of the PEF domain of ALG-2ΔGF122 in the Ca2+-bound form and compared it with that of ALG-2. Deletion of the two residues shortened α-helix 5 (α5) and changed the configuration of the R125 side chain so that it partially blocked Pocket 1. A wall created by the main chain of 121-GFG-123 and facing the two pockets was destroyed. Surprisingly, however, substitution of F122 with Ala or Gly, but not with Trp, increased the Alix-binding capacity in binding assays. The F122 substitutions exhibited different effects on binding of ALG-2 to other known interacting proteins, including TSG101 (Tumor susceptibility gene 101) and annexin A11. The X-ray crystal structure of the F122A mutant revealed that removal of the bulky F122 side chain not only created an additional open space in Pocket 2 but also abolished inter-helix interactions with W95 and V98 (present in α4) and that α5 inclined away from α4 to expand Pocket 2, suggesting acquirement of more appropriate positioning of the interacting residues to accept Alix. Conclusions: We found that the inability of the two-residue shorter ALG-2 isoform to bind Alix is not due to the absence of bulky side chain of F122 but due to deformation of a main-chain wall facing pockets 1 and 2. Moreover, a residue at the position of F122 contributes to target specificity and a smaller side chain is preferable for Alix binding but not favored to bind annexin A11.