Suzi Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Suzi Liang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Bradley E. Treeby
Department of Medical Physics and Biomedical Engineering, University College London, London, UK
2 shared publications - Eleanor Martin
Department of Medical Physics and Biomedical Engineering, University College London, London, UK
2 shared publications - Hairong Zheng
Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
2 shared publications - Min Su
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
2 shared publications - Weibao Qiu
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
2 shared publications - Zhiqiang Zhang
Shenzhen Institutes of Advanced Technology and Key Laboratory of Biomedical Imaging Science and System, Chinese Academy of Sciences, and State Key Laboratory of Biomedical Imaging Science and System, Shenzhen, China
2 shared publications
Latest Publications
- Open Access
- 24 November 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (11) , 115018
Experimental optimization of a multiple-reflection system for acoustic material property measurement
Knowledge of the acoustic properties of materials is critical for many applications of acoustics. Common methods for measuring acoustic material properties include the through transmission substitution-insertion method (SIM) and the multiple-reflection method (MRM). However, the accuracy and uncertainty of MRM measurements have not been evaluated as widely as for SIM. This study investigates the impact of system compressional force, buffer rod diameter, and buffer rod and specimen surface conditions on the accuracy and repeatability of MRM measurements of the attenuation coefficient and longitudinal sound velocity of 3D printed specimens validated against SIM measurements. The measurement accuracy and repeatability improved as the system compression was increased, with attenuation coefficients measured by SIM and MRM at 0.5 MHz converging to within 0.1 dB cm −1 (1.6 ± 0.1 dB cm −1 versus 1.7 ± 0.2 dB cm −1 ) for the RGDA8625 material. A buffer rod of at least twice the diameter of the transducer was required for agreement between the two methods and differences of > 40% were measured with narrower buffer rods. The buffer rod and specimen should be sufficiently flat and well-polished to minimize errors. These findings may guide future system design and optimization, and suggest that experimental convergence should be verified in the setup. This may aid the standardization of measurement protocols, helping to improve the accuracy and repeatability of acoustic material property measurements.
- 24 November 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (11) , 115018
Open AccessExperimental optimization of a multiple-reflection system for acoustic material property measurement
Knowledge of the acoustic properties of materials is critical for many applications of acoustics. Common methods for measuring acoustic material properties include the through transmission substitution-insertion method (SIM) and the multiple-reflection method (MRM). However, the accuracy and uncertainty of MRM measurements have not been evaluated as widely as for SIM. This study investigates the impact of system compressional force, buffer rod diameter, and buffer rod and specimen surface conditions on the accuracy and repeatability of MRM measurements of the attenuation coefficient and longitudinal sound velocity of 3D printed specimens validated against SIM measurements. The measurement accuracy and repeatability improved as the system compression was increased, with attenuation coefficients measured by SIM and MRM at 0.5 MHz converging to within 0.1 dB cm −1 (1.6 ± 0.1 dB cm −1 versus 1.7 ± 0.2 dB cm −1 ) for the RGDA8625 material. A buffer rod of at least twice the diameter of the transducer was required for agreement between the two methods and differences of > 40% were measured with narrower buffer rods. The buffer rod and specimen should be sufficiently flat and well-polished to minimize errors. These findings may guide future system design and optimization, and suggest that experimental convergence should be verified in the setup. This may aid the standardization of measurement protocols, helping to improve the accuracy and repeatability of acoustic material property measurements.
- 26 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (5) , 607-620
Review of the Low-Temperature Acoustic Properties of Water, Aqueous Solutions, Lipids, and Soft Biological Tissues
Existing data on the acoustic properties of low-temperature biological materials is limited and widely dispersed across fields. This makes it difficult to employ this information in the development of ultrasound applications in the medical field, such as cryosurgery and rewarming of cryopreserved tissues. In this review, the low-temperature acoustic properties of biological materials, and the measurement methods used to acquire them were collected from a range of scientific fields. The measurements were reviewed from the acoustic set-up to thermal methodologies for samples preparation, temperature monitoring, and system insulation. The collected data contain the longitudinal and shear velocity, and attenuation coefficient of biological soft tissues and biologically relevant substances - water, aqueous solutions, and lipids - in the temperature range down to -50°C and in the frequency range from 108 kHz to 25 MHz. The Multiple-Reflection Method (MRM) was found to be the preferred method for low-temperature samples, with a buffer-rod inserted between the transducer and sample to avoid direct contact. Longitudinal velocity changes are observed through the phase transition zone, which is sharp in pure water, and occurs more slowly and at lower temperatures with added solutes. Lipids show longer transition zones with smaller sound velocity changes; with the longitudinal velocity changes observed during phase transition in tissues lying between these two extremes. More general conclusions on the shear velocity and attenuation coefficient at low-temperatures are restricted by the limited data. This review enhance knowledge guiding for further development of ultrasound applications in low-temperature biomedical fields, and may help to increase the precision and standardisation of low-temperature acoustic property measurements.
- 26 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (5) , 607-620
Review of the Low-Temperature Acoustic Properties of Water, Aqueous Solutions, Lipids, and Soft Biological Tissues
Existing data on the acoustic properties of low-temperature biological materials is limited and widely dispersed across fields. This makes it difficult to employ this information in the development of ultrasound applications in the medical field, such as cryosurgery and rewarming of cryopreserved tissues. In this review, the low-temperature acoustic properties of biological materials, and the measurement methods used to acquire them were collected from a range of scientific fields. The measurements were reviewed from the acoustic set-up to thermal methodologies for samples preparation, temperature monitoring, and system insulation. The collected data contain the longitudinal and shear velocity, and attenuation coefficient of biological soft tissues and biologically relevant substances - water, aqueous solutions, and lipids - in the temperature range down to -50°C and in the frequency range from 108 kHz to 25 MHz. The Multiple-Reflection Method (MRM) was found to be the preferred method for low-temperature samples, with a buffer-rod inserted between the transducer and sample to avoid direct contact. Longitudinal velocity changes are observed through the phase transition zone, which is sharp in pure water, and occurs more slowly and at lower temperatures with added solutes. Lipids show longer transition zones with smaller sound velocity changes; with the longitudinal velocity changes observed during phase transition in tissues lying between these two extremes. More general conclusions on the shear velocity and attenuation coefficient at low-temperatures are restricted by the limited data. This review enhance knowledge guiding for further development of ultrasound applications in low-temperature biomedical fields, and may help to increase the precision and standardisation of low-temperature acoustic property measurements.
- 26 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 98-105
Evaluation of Blood Induced Influence for High-Definition Intravascular Ultrasound (HD-IVUS)
High-definition intravascular ultrasound (HD-IVUS) utilizing more than 80 MHz frequency to assess atherosclerotic plaque, can theoretically achieve an axial resolution of less than $20~\mu \text{m}$ . However, the blood is a high-attenuation source at high frequency, which would affect the imaging quality. There has been no research evaluating the blood-induced influence on HD-IVUS imaging. And whether a temporary removal of blood is needed for HD-IVUS is unknown. In this study, an ultrahigh-frequency (100 MHz) ultrasound transducer was developed to evaluate the blood-induced attenuation for HD-IVUS imaging. A series of tungsten-wire phantom images in saline and blood at varying hematocrits were obtained. The images showed that blood did influence the ultrahigh-frequency imaging quality greatly. The signal-to-noise ratio (SNR) decrease by 71.7% in porcine whole blood compared to that in saline at the same depth of 2.3 mm. Moreover, the potential flushing schemes for HD-IVUS were studied in varying hematocrits. Three flushing agents commonly used in intravascular optical coherence tomography (IV-OCT) were investigated, including iohexol, mannitol, and dextran 5% and saline as the control group. The attenuation of blood in varying hematocrits/flushing agents was measured from 90 to 110 MHz. The result indicated dextran 5% was a suitable flushing agent for HD-IVUS due to its less signal attenuation compared to others.
- 26 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (1) , 98-105
Evaluation of Blood Induced Influence for High-Definition Intravascular Ultrasound (HD-IVUS)
High-definition intravascular ultrasound (HD-IVUS) utilizing more than 80 MHz frequency to assess atherosclerotic plaque, can theoretically achieve an axial resolution of less than $20~\mu \text{m}$ . However, the blood is a high-attenuation source at high frequency, which would affect the imaging quality. There has been no research evaluating the blood-induced influence on HD-IVUS imaging. And whether a temporary removal of blood is needed for HD-IVUS is unknown. In this study, an ultrahigh-frequency (100 MHz) ultrasound transducer was developed to evaluate the blood-induced attenuation for HD-IVUS imaging. A series of tungsten-wire phantom images in saline and blood at varying hematocrits were obtained. The images showed that blood did influence the ultrahigh-frequency imaging quality greatly. The signal-to-noise ratio (SNR) decrease by 71.7% in porcine whole blood compared to that in saline at the same depth of 2.3 mm. Moreover, the potential flushing schemes for HD-IVUS were studied in varying hematocrits. Three flushing agents commonly used in intravascular optical coherence tomography (IV-OCT) were investigated, including iohexol, mannitol, and dextran 5% and saline as the control group. The attenuation of blood in varying hematocrits/flushing agents was measured from 90 to 110 MHz. The result indicated dextran 5% was a suitable flushing agent for HD-IVUS due to its less signal attenuation compared to others.
- 16 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (6) , 2212-2218
Flexible Pico-Liter Acoustic Droplet Ejection Based on High-Frequency Ultrasound Transducer
Acoustic droplet ejection (ADE) uses the acoustic energy produced by a focused ultrasound beam to provide a noncontact, highly precise, automatic, and cost-effective liquid transfer method for life science applications. The reported minimum precision of the current acoustic liquid transfer technology is 1 nL. Since precision improvement always brings valuable results in biological research, it is highly necessary to develop pico-liter precision liquid transfer technology. In this work, we developed a 40-MHz ultrahigh -frequency focused ultrasound transducer with a large aperture of 7×7 mm 2 and a wide bandwidth of 76.4%. The designed transducer can successfully eject pico-liter droplets, and the droplet ejection accuracy ranges from 28 to 439 pL. The effects of the acoustic parameters, including excitation amplitude, pulsewidth, and frequency, on the size of the ejected droplet were studied. A wide range of ejected droplet sizes could be obtained by adjusting the acoustic parameters, thereby making liquid transfer flexible. The flexible pico-liter liquid transfer based on the wide-bandwidth, high-frequency ultrasound transducer is easier to achieve automatically, and thus it has broad prospects in biological research and industrial applications.
- 16 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (6) , 2212-2218
Flexible Pico-Liter Acoustic Droplet Ejection Based on High-Frequency Ultrasound Transducer
Acoustic droplet ejection (ADE) uses the acoustic energy produced by a focused ultrasound beam to provide a noncontact, highly precise, automatic, and cost-effective liquid transfer method for life science applications. The reported minimum precision of the current acoustic liquid transfer technology is 1 nL. Since precision improvement always brings valuable results in biological research, it is highly necessary to develop pico-liter precision liquid transfer technology. In this work, we developed a 40-MHz ultrahigh -frequency focused ultrasound transducer with a large aperture of 7×7 mm 2 and a wide bandwidth of 76.4%. The designed transducer can successfully eject pico-liter droplets, and the droplet ejection accuracy ranges from 28 to 439 pL. The effects of the acoustic parameters, including excitation amplitude, pulsewidth, and frequency, on the size of the ejected droplet were studied. A wide range of ejected droplet sizes could be obtained by adjusting the acoustic parameters, thereby making liquid transfer flexible. The flexible pico-liter liquid transfer based on the wide-bandwidth, high-frequency ultrasound transducer is easier to achieve automatically, and thus it has broad prospects in biological research and industrial applications.