Tolga Goren has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dosimetric Electromagnetic Safety of People With Implants: A Neglected Population?

    by Lena Kranold, Jingtian Xi, Tolga Goren, Niels Kuster

    Electromagnetic (EM) safety guidelines are designed to protect the general public and workers from the risks posed by exposure to EM sources of all types, with the exception of medical EM sources. However, it has never been systematically evaluated whether individuals with conductive implants are also protected by these guidelines or whether the local field enhancement due to presence of the implant may pose an unacceptable risk under certain realistic exposure conditions. To address this important knowledge and regulatory gap, we first evaluated the upper bound of the local enhancement of bare and insulated generic implants of 0.5 λ (approximately equal to resonant) and 0.1 λ lengths, but restricted the maximum length to 2 m, as a function of tissue properties and frequency (10 kHz to 1 GHz). Results for uniform electric field excitation showed local enhancement of psSAR 10mg and of locally averaged E‐field, respectively, compared to the background in the presence of a generic implant of 10 dB (1 GHz) to over 100 dB at frequencies under 100 MHz. In the next step, we tested the hypothesis that fields induced inside the human body by realistic near‐field sources are not sufficiently uniform to generate results in enhancement that could pose unacceptable risk. Common implant trajectories were inserted into the Virtual Population human anatomical model Ella V3.0, and the model was exposed to the following conditions (i) a standard source representing a wireless power transfer source operating at 85 kHz and (ii) a dipole source that operates at 450 MHz within the current exposure limits. Results show that the safety limit is exceeded at the tip of the implant by a factor of >  10 ( > 20 dB) or >  115 V/m at 85 kHz, whereas the locally induced specific absorption rate averaged over 10 mg at 450 MHz was 7.9 W/kg, resulting in a temperature increase after 6 min of <  0.4 K. Hence, as the hypothesis was falsified at frequencies <  450 MHz, patients with implants are inadequately protected by current safety and product guidelines. In the discussions, proposals for how to close this regulatory gap are provided. Bioelectromagnetics. 00:00–00, 2025. © 2025 Bioelectromagnetics Society.


  • Open Access

    Impact of simultaneous exposure to RF and gradient electromagnetic fields on implant MR safety labeling

    by Umberto Zanovello, Alessandro Arduino, Carina Fuss, Tolga Goren, Luca Zilberti, Oriano Bottauscio

    Purpose: To investigate whether heating contributions produced by radiofrequency (RF) and gradient fields superpose sufficiently at the worst‐case locations to justify their simultaneous consideration in magnetic resonance imaging (MRI) implant safety labeling. Theory and Methods: Six implant models were positioned in an ASTM phantom and realistically implanted in two anatomical human models, and exposed to gradient and RF fields at 64 MHz and 128 MHz. The simulations with the anatomical body models considered different axial exposure landmarks inside the RF and gradient body coils. The exposures were scaled to represent two sets of scenarios: either limited by the implant's MR conditional labeling to a fixed peak temperature rise, or representing an EPI or TrueFISP examination with clinically relevant parameters, where the implant label is not limiting. Results: The temperature enhancement due to the combined RF and gradient sources, evaluated with respect to the maximum values obtained separately, depends on the implant, pulse sequence, and exposure landmark. A maximum relative enhancement of about 65% was found in the ASTM phantom, and maximum absolute enhancements above 0.3 K were found in anatomical models with realistic pulse sequences. Conclusion: There are clinically relevant MR examination scenarios where the maximum heating contributions produced by RF and gradient fields combine, enhancing the local peak temperature increase beyond that obtained from either assessment alone. The results prove to be useful for defining safety margins on the maximum allowable temperature increase, avoiding the requirement of a combined gradient coil and RF test.


  • Open Access

    Breast MRI in the prone position: impact on RF-induced heating of active implantable medical devices

    by Aiping Yao, Tolga Goren, Bryn Alexander Lloyd, Carina Johanna Fuss, Silvia Farcito, Jing Wang, Pengfei Yang, Niels Kuster

    Objective: Prone (face-down) postures, commonly used in breast examination, as well as in wrist and elbow imaging, change the the induced current path in the body and therefore the incident electric fields to the implants during MR examination, potentially leading to significant variations from risk predictions made in supine postures. The goal of this work is to investigates the impact of prone breast examination postures, compared to supine MR examination postures, on the RF-induced heating of medical implants. Approach: To assess these effects, the Virtual Population anatomical model Ella was modified with breast shapes typical of a prone examination, and posed with one or both arms raised above the head. The head was positioned either adjacent to the bore wall, typical for breast MR examinations, or centrally within the bore, similar to supine positioning. The RF-induced electric fields and worst-case power depositions were compared with those from the supine Ella model for representative generic pacemaker, deep brain stimulator (DBS), and cochlear implants, at breast imaging landmarks. Main Results: The results indicate that prone positions typical of breast examination can lead to differences in incident electric field and corresponding RF-heating of, at least, up to 5 dB at 1.5 T, and up to 2.5 dB at 3.0 T, for cochlear implants, 1-2 dB for DBS, and 1 dB for pacemakers, compared to the corresponding supine imaging landmarks. Significance: These findings underscore the importance of considering patient posture in RF safety assessments of implantable medical devices in the head and neck regions. To avoid underestimation of local RF exposure near these implants, a comprehensive posture-aware safety protocol should be designed and considered during the RF safety evaluation and labeling.

  • Open Access

    Influence of patient head definition on induced E‐fields during MR examination

    by Tolga Goren, Sylvain Reboux, Silvia Farcito, Bryn Lloyd, Niels Kuster

    Purpose: Radiofrequency (RF) exposure during MR examination is limited by IEC 60601‐2‐33 to prevent thermal hazards to patients. These limits are also the basis to derive the maximum induced field for the demonstration of MR safety of implants per ISO/TS 10974 (2018). One limit is the head‐averaged specific absorption rate (SAR), for which the head extent is defined differently by MR and implant vendors. The purpose of this technical note is to inform MR safety stakeholders on the sensitivity of safety evaluations due to different head extent definitions.Methods: RF distributions from the validated MRIxViP exposure libraries of 12 high‐resolution human anatomical models were scaled to the normative SAR limits for different definitions of the head extent to compare the corresponding induced SAR and electric (E‐)field levels.Results: The definitions of the head extent used by major implant vendors and defined in ISO/TS 10974 (2018) are larger than those introduced in IEC 60601‐2‐33 (2022), resulting in lower RF head exposure by up to 2.4 dB (factor 1.7). Other proposed definitions of the head result in intermediate values.Conclusion: The different head extents result in different maximum RF exposures affecting the risk assessment by up to a factor of 1.7. The results of this study can be used to estimate the additional uncertainty in safety assessments. Future revisions of MR standards should eliminate this inconsistency.


  • Open Access

    Induced radiofrequency fields in patients undergoing MR examinations: insights for risk assessment

    by Aiping Yao, Manuel Murbach, Tolga Goren, Earl Zastrow, Wolfgang Kainz, Niels Kuster

    Purpose . To characterize and quantify the induced radiofrequency (RF) electric ( E )-fields and B 1+rms fields in patients undergoing magnetic resonance (MR) examinations; to provide guidance on aspects of RF heating risks for patients with and without implants; and to discuss some strengths and limitations of safety assessments in current ISO, IEC, and ASTM standards to determine the RF heating risks for patients with and without implants. Methods . Induced E -fields and B 1+rms fields during 1.5 T and 3 T MR examinations were numerically estimated for high-resolution patient models of the Virtual Population exposed to ten two-port birdcage RF coils from head to feet imaging landmarks over the full polarization space, as well as in surrogate ASTM phantoms. Results . Worst-case B 1+rms exposure greater than 3.5 μ T (1.5 T) and 2 μ T (3 T) must be considered for all MR examinations at the Normal Operating Mode limit. Representative induced E -field and specific absorption rate distributions under different clinical scenarios allow quick estimation of clinical factors of high and reduced exposure. B 1 shimming can cause +6 dB enhancements to E -fields along implant trajectories. The distribution and magnitude of induced E -fields in the ASTM phantom differ from clinical exposures and are not always conservative for typical implant locations. Conclusions. Field distributions in patient models are condensed, visualized for quick estimation of risks, and compared to those induced in the ASTM phantom. Induced E -fields in patient models can significantly exceed those in the surrogate ASTM phantom in some cases. In the recent 19 ε 2 revision of the ASTM F2182 standard, the major shortcomings of previous versions have been addressed by requiring that the relationship between ASTM test conditions and in vivo tangential E -fields be established, e.g. numerically. With this requirement, the principal methods defined in the ASTM standard for passive implants are reconciled with those of the ISO 10974 standard for active implantable medical devices.


  • Open Access

    Radiofrequency‐induced heating of broken and abandoned implant leads during magnetic resonance examinations

    by Aiping Yao, Tolga Goren, Theodoros Samaras, Niels Kuster, Wolfgang Kainz

    Purpose The risks of RF-induced heating of active implantable medical device (AIMD) leads during MR examinations must be well understood and realistically assessed. In this study, we evaluate the potential additional risks of broken and abandoned (cut) leads. Methods First, we defined a generic AIMD with a metallic implantable pulse generator (IPG) and a 100-cm long lead containing 1 or 2 wires. Next, we numerically estimated the deposited in vitro lead-tip power for an intact lead, as well as with wire breaks placed at 10 cm intervals. We studied the effect of the break size (wire gap width), as well as the presence of an intact wire parallel to the broken wire, and experimentally validated the numeric results for the configurations with maximum deposited in vitro lead-tip power. Finally, we performed a Tier 3 assessment of the deposited in vivo lead-tip power for the intact and broken lead in 4 high resolution virtual population anatomic models for over 54,000 MR examination scenarios. Results The enhancement of the deposited lead-tip power for the broken leads, compared to the intact lead, reached 30-fold in isoelectric exposure, and 16-fold in realistic clinical exposures. The presence of a nearby intact wire, or even a nearby broken wire, reduced this enhancement factor to <7-fold over the intact lead. Conclusion Broken and abandoned leads can pose increased risk of RF-induced lead-tip heating to patients undergoing MR examinations. The potential enhancement of deposited in vivo lead-tip power depends on location and type of the wire break, lead design, and clinical routing of the lead, and should be carefully considered when performing risk assessment for MR examinations and MR conditional labeling.


  • Open Access

    Influence of Solutes on Hydration and Lubricity of Dextran Brushes

    by Tolga Goren, Rowena Crockett, Nicholas D. Spencer

    The characteristic lubricity and non-fouling behavior of polymer brushes is critically dependent on the solvation of the polymer chains, as well as the chain–chain interactions. Dextran brushes have shown promise as non-toxic aqueous lubricant films, and are similar in composition to natural lubricating systems, while their comparative simplicity allows for controlled preparation and fine characterization. This project entails measuring the solvation and lubricity of dextran brushes in the presence of additives which modify the inter-chain hydrogen bonding. The thickness and refractive index of the film were measured during adsorption of the brush layer onto a silica substrate and the subsequent immersion in solutions of potassium sulfate and α, α-trehalose. We also studied the lubricity of the system as a function of normal loading using colloidal-probe AFM. Both solutes are shown to have a minimal effect on the hydration of the brush while significantly reducing the brush lubricity, indicating that inter-chain hydrogen bonding supports the load-bearing capacity of polysaccharide brushes.