    RF-EMF response modeling of implantable medical electrodes under 1.5T and 3T MRI exposure using a lumped element model approach

    by Jinting Fu, Aiping Yao, Jing Wang, Pengfei Yang

    Accurate assessment of radiofrequency electromagnetic field (RF-EMF) induced heating risks for patients with implantable medical electrodes during magnetic resonance imaging (MRI) remains challenging, particularly when implementing the Tier 4(-) evaluation methodology, outlined in the latest ISO 10974 IS1 Committee Draft for Vote (CDV),, in heterogeneous tissue environments. This work introduces an equivalent lumped element model (LEM) to streamline in vivo RF response modeling of implantable medical electrodes in complicated tissue environments without substantially increasing computational burden. Extensive numerical studies were conducted for generic helical implantable medical electrodes with lead lengths of 400, 500, and 600 mm in homogeneous, heterogeneous, and anatomically realistic tissue environments from the Virtual Population model Ella, at 1.5 T and 3.0 T. The LEM-based approach consistently yielded more accurate estimates of RF-EMF-induced power deposited at the implant hotspot than transfer functions derived from simplified tissue configurations representative of Tier 3 evaluations. In particular, the LEM reproduced the equivalent impedance and transfer function of the detailed implantable medical electrode, enabling efficient evaluation of RF-EMF-induced heating in clinically relevant heterogeneous tissue environment. Experimental validation with a commercial implantable medical electrode further showed close agreement between the LEM-predicted transfer function and measurements of the commercial device. These results indicate that the proposed methodology addresses key limitations of conventional modeling strategies and provides a robust, computationally efficient framework for Tier 4(-) RF-EMF-induced heating risk assessment in clinical MRI exposure.

  • Open Access

    Breast MRI in the prone position: impact on RF-induced heating of active implantable medical devices

    by Aiping Yao, Tolga Goren, Bryn Alexander Lloyd, Carina Johanna Fuss, Silvia Farcito, Jing Wang, Pengfei Yang, Niels Kuster

    Objective: Prone (face-down) postures, commonly used in breast examination, as well as in wrist and elbow imaging, change the the induced current path in the body and therefore the incident electric fields to the implants during MR examination, potentially leading to significant variations from risk predictions made in supine postures. The goal of this work is to investigates the impact of prone breast examination postures, compared to supine MR examination postures, on the RF-induced heating of medical implants. Approach: To assess these effects, the Virtual Population anatomical model Ella was modified with breast shapes typical of a prone examination, and posed with one or both arms raised above the head. The head was positioned either adjacent to the bore wall, typical for breast MR examinations, or centrally within the bore, similar to supine positioning. The RF-induced electric fields and worst-case power depositions were compared with those from the supine Ella model for representative generic pacemaker, deep brain stimulator (DBS), and cochlear implants, at breast imaging landmarks. Main Results: The results indicate that prone positions typical of breast examination can lead to differences in incident electric field and corresponding RF-heating of, at least, up to 5 dB at 1.5 T, and up to 2.5 dB at 3.0 T, for cochlear implants, 1-2 dB for DBS, and 1 dB for pacemakers, compared to the corresponding supine imaging landmarks. Significance: These findings underscore the importance of considering patient posture in RF safety assessments of implantable medical devices in the head and neck regions. To avoid underestimation of local RF exposure near these implants, a comprehensive posture-aware safety protocol should be designed and considered during the RF safety evaluation and labeling.

  • Open Access

    Impact of MRI RF coil design on the RF-induced heating of medical implants: fixed B 1 + rms exposure versus normal operating mode

    by Aiping Yao, Zihan Li, Mingjuan Ma

    A direct comparison of the impact of RF coil design under specific absorption rate and B 1 + rms limitations are investigated and quantified using RF coils of different geometries and topologies at 64 MHz and 128 MHz. The RF-induced in vivo electric field and power deposition of a 50 cm long pacemaker and 55 cm long deep brain stimulator (DBS) are evaluated within two anatomical models exposed with these RF coils. The associated uncertainty is quantified and analyzed under a fixed B 1 + rms incident and normal operating mode. For a fixed B 1 + rms incident, the in vivo incident field shows a much higher uncertainty (>5.6 dB) to the RF coil diameter compared to other design parameters (e.g. B 1 + rms field to the untested implant will lead to a large variation in the induced incident and power deposition of the implant, as a result, a larger safe margin when different coil designs (e.g. coil diameter) are considered.


  • A CP-ANN-Based RF-Induced Heating Estimation Method for Passive Orthopaedic Implantable Devices Under 1.5 T and 3.0 T MRI

    by Aiping Yao, Yunfeng Pei, Junchen He, Jing Wang, Pengfei Yang

    This article provides an efficient and reliable alternative assessment of radio frequency (RF)-induced heating of orthopaedic implants. The concept of the heating factor is defined to model the RF response of orthopaedic implants, and an artificial neural network based on the Chebyshev parameter model-based artificial neural network (CP-ANN) is designed to achieve efficient and accurate prediction of the heating factor. The performance of the proposed CP-ANN is validated with standard simulations and measurements. The in vivo temperature of five clinical scenarios with representative orthopaedic implants in different tissue environments is evaluated using the proposed method and compared with in vitro measurements and Tier 4 simulations. The results show that with the proposed CP-ANN, the heating factors of different types of passive implants in different tissue environments can be predicted accurately (R=0.99) and efficiently (e.g., in 6 s), with more than 250-fold improvements in efficiency compared with existing algorithms. Consequently, this work can provide an efficient and reliable option for evaluating induced RF heating of orthopaedic implants under magnetic resonance imaging examination. By considering the influence of the tissue environment, this work also provides scientific insight into the potential uncertainty caused by the discrepancy between in vitro and in vivo tissue environments.


  • A machine learning-based approach for RF transfer function modeling of active implantable medical electrodes at 3T MRI

    by Aiping Yao, Mingjuan Ma, Hexuan Shi

    Objective. The objective of this work is to propose a machine learning-based approach to rapidly and efficiently model the radiofrequency (RF) transfer function of active implantable medical (AIM) electrodes, and to overcome the limitations and drawbacks of traditional measurement methods when applied to heterogeneous tissue environments. Approach. AIM electrodes with different geometries and proximate tissue distributions were considered, and their RF transfer functions were modeled numerically. Machine learning algorithms were developed and trained with the simulated transfer function datasets for homogeneous and heterogeneous tissue distributions. The performance of the method was analyzed statistically and validated experimentally and numerically. A comprehensive uncertainty analysis was performed and uncertainty budgets were derived. Main results. The proposed method is able to predict the RF transfer function of AIM electrodes under different tissue distributions, with mean correlation coefficients r of 0.99 and 0.98 for homogeneous and heterogeneous environments, respectively. The results were successfully validated by experimental measurements (e.g. the uncertainty of less than 0.9 dB) and numerical simulation (e.g. transfer function uncertainty in vivo power deposition underestimation was observed near generic pacemakers when using a simplified homogeneous tissue model. Significance. Provide an efficient alternative of transfer function modeling, which allows a more realistic tissue distribution and the potential underestimation of in vivo RF-induced power deposition near the AIM electrode can be reduced.


  • Open Access

    Exposure Optimization Trial for Patients With Medical Implants During MRI Exposure: Balance Between the Completeness and Efficiency

    by Aiping Yao, Pengfei Yang, Mingjuan Ma, Yunfeng Pei

    Elongated conductors, such as pacemaker leads, can couple to the MRI radio-frequency (RF) field during MRI scan and cause dangerous tissue heating. By selecting proper RF exposure conditions, the RF-induced power deposition can be suppressed. As the RF-induced power deposition is a complex function of multiple clinical factors, the problem remains how to perform the exposure selection in a comprehensive and efficient way. The purpose of this work is to demonstrate an exposure optimization trail that allows a comprehensive optimization in an efficient and traceable manner. The proposed workflow is demonstrated with a generic 40 cm long cardio pacemaker, major components of the clinical factors are decoupled from the redundant data set using principle component analysis, the optimized exposure condition can not only reduce the in vivo power deposition but also maintain good image quality.

  • Open Access

    Radiofrequency‐induced heating of broken and abandoned implant leads during magnetic resonance examinations

    by Aiping Yao, Tolga Goren, Theodoros Samaras, Niels Kuster, Wolfgang Kainz

    Purpose The risks of RF-induced heating of active implantable medical device (AIMD) leads during MR examinations must be well understood and realistically assessed. In this study, we evaluate the potential additional risks of broken and abandoned (cut) leads. Methods First, we defined a generic AIMD with a metallic implantable pulse generator (IPG) and a 100-cm long lead containing 1 or 2 wires. Next, we numerically estimated the deposited in vitro lead-tip power for an intact lead, as well as with wire breaks placed at 10 cm intervals. We studied the effect of the break size (wire gap width), as well as the presence of an intact wire parallel to the broken wire, and experimentally validated the numeric results for the configurations with maximum deposited in vitro lead-tip power. Finally, we performed a Tier 3 assessment of the deposited in vivo lead-tip power for the intact and broken lead in 4 high resolution virtual population anatomic models for over 54,000 MR examination scenarios. Results The enhancement of the deposited lead-tip power for the broken leads, compared to the intact lead, reached 30-fold in isoelectric exposure, and 16-fold in realistic clinical exposures. The presence of a nearby intact wire, or even a nearby broken wire, reduced this enhancement factor to <7-fold over the intact lead. Conclusion Broken and abandoned leads can pose increased risk of RF-induced lead-tip heating to patients undergoing MR examinations. The potential enhancement of deposited in vivo lead-tip power depends on location and type of the wire break, lead design, and clinical routing of the lead, and should be carefully considered when performing risk assessment for MR examinations and MR conditional labeling.


  • Anatomical Model Uncertainty for RF Safety Evaluation of Metallic Implants Under MRI Exposure

    by Aiping Yao, Earl Zastrow, Eugenia Cabot, Bryn Lloyd, Beatrice Schneider, Wolfgang Kainz, Niels Kuster

    The Virtual Population (ViP) phantoms have been used in many dosimetry studies, yet, to date, anatomical phantom uncertainty in radiofrequency (RF) research has largely been neglected. The objective of this study is to gain insight, for the first time, regarding the uncertainty in RF‐induced fields during magnetic resonance imaging associated with tissue assignment and segmentation quality and consistency in anatomical phantoms by evaluating the differences between two generations of ViP phantoms, ViP1.x and ViP3.0. The RF‐induced 10g‐average electric (E‐) fields, tangential E‐fields distribution along active implantable medical devices (AIMD) routings, and estimated AIMD heating were compared for five phantoms that are part of both ViP1.x and ViP3.0. The results demonstrated that differences exceeded 3 dB (−29%, +41%) for local quantities and 1 dB (±12% for field, ±25% for power) for integrated and volume‐averaged quantities (e.g., estimated AIMD‐heating and 10 g‐average E‐fields), while the variation across different ViP phantoms of the same generation can exceed 10 dB (−68% and +217% for field, −90% and +900% for power). In conclusion, the anatomical phantom uncertainty associated with tissue assignment and segmentation quality/consistency is larger than previously assumed, i.e., 0.6 dB or ±15% (k = 1) for AIMD heating. Further, multiple phantoms based on different volunteers covering the target population are required for quantitative analysis of dosimetric endpoints, e.g., AIMD heating, which depend on patient anatomy. Phantoms with the highest fidelity in tissue assignment and segmentation should be used, as these ensure the lowest uncertainty and possible underestimation of exposure. To verify that the uncertainty decreases monotonically with improved phantom quality, the evaluation of differences between phantom generations should be repeated for any improvement in segmentation. Bioelectromagnetics. 2019;40:458–471. © 2019 Bioelectromagnetics Society


  • Efficient and Reliable Assessment of the Maximum Local Tissue Temperature Increase at the Electrodes of Medical Implants under MRI Exposure

    by Aiping Yao, Earl Zastrow, Esra Neufeld, Niels Kuster

    Standard risk evaluations posed by medical implants during magnetic resonance imaging (MRI) includes (i) the assessment of the total local electromagnetic (EM) power (P) absorbed in the vicinity of the electrodes and (ii) the translation of P into a local in vivo tissue temperature increase ∆T (P2∆T) in animal experiments or simulations. We investigated the implant/tissue modeling requirements and associated uncertainties by applying full‐wave EM and linear bioheat solvers to different implant models, incident field conditions, electrode configurations, and tissue models. Results show that the magnitude of the power is predominately determined by the lead, while the power distribution, and the P2∆T conversion, is determined by the electrode and surrounding tissues. P2∆T is strongly dependent on the size of the electrode, tissue type in contact with the electrode, and tissue inhomogeneity (factor of >2 each) but less on the modeling of the lead (<±10%) and incident field distribution along the lead (<±20%). This was confirmed by means of full‐wave simulations performed with detailed high‐resolution anatomical phantoms exposed to two commonly used MRI clinical scenarios (64 and 128 MHz), resulting in differences of less than 6%. For the determination of P2∆T, only the electrode and surrounding tissues must be modeled in great detail, whereas the lead can be modeled as a computationally efficient simplified structure exposed to a uniform field. The separate assessments of lead and electrode reduce the overall computational effort by several orders of magnitude. The errors introduced by this simplification can be considered by uncertainty terms. Bioelectromagnetics. 2019;40:422–433. © 2019 Bioelectromagnetics Society.


  • Open Access

    Data‐Driven Experimental Evaluation Method for the Safety Assessment of Implants With Respect to RF‐Induced Heating During MRI

    by Aiping Yao, Earl Zastrow, Niels Kuster

    Small (mm size) distal electrodes of active medical implants can cause localized radio frequency (RF)‐induced power deposition with extreme spatial gradient (5–6 dB/mm). We propose a method that aims to improve the accuracy of the traditional experimental evaluation, which relies solely on hardware instrumentation. A numerically derived local deposition distribution is used to assist the estimation of power deposition. The method was successfully validated against numerical simulations, considering three different generic implants with a single electrode. The power deposition in the surrounding region of the implant electrodes estimated with the proposed method was validated with less than 1 dB (30%) of uncertainty.