Breast MRI in the prone position: impact on RF-induced heating of active implantable medical devices
Open Access
- 29 July 2025
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (17)
Abstract
Objective: Prone (face-down) postures, commonly used in breast examination, as well as in wrist and elbow imaging, change the the induced current path in the body and therefore the incident electric fields to the implants during MR examination, potentially leading to significant variations from risk predictions made in supine postures. The goal of this work is to investigates the impact of prone breast examination postures, compared to supine MR examination postures, on the RF-induced heating of medical implants. Approach: To assess these effects, the Virtual Population anatomical model Ella was modified with breast shapes typical of a prone examination, and posed with one or both arms raised above the head. The head was positioned either adjacent to the bore wall, typical for breast MR examinations, or centrally within the bore, similar to supine positioning. The RF-induced electric fields and worst-case power depositions were compared with those from the supine Ella model for representative generic pacemaker, deep brain stimulator (DBS), and cochlear implants, at breast imaging landmarks. Main Results: The results indicate that prone positions typical of breast examination can lead to differences in incident electric field and corresponding RF-heating of, at least, up to 5 dB at 1.5 T, and up to 2.5 dB at 3.0 T, for cochlear implants, 1-2 dB for DBS, and 1 dB for pacemakers, compared to the corresponding supine imaging landmarks. Significance: These findings underscore the importance of considering patient posture in RF safety assessments of implantable medical devices in the head and neck regions. To avoid underestimation of local RF exposure near these implants, a comprehensive posture-aware safety protocol should be designed and considered during the RF safety evaluation and labeling.Keywords
Funding Information
- Swiss State Secretariat for Education, Research and Innovation
- project 21NRM05 STASIS
- Katja Pokovic Fellowship
- Jiangxi Province "Ganpo Talents" Young Leading Talent Program for Innovation
This publication has 19 references indexed in Scilit:
- Influence of patient head definition on induced E‐fields during MR examinationMagnetic Resonance in Medicine, 2023
- A workflow for predicting temperature increase at the electrical contacts of deep brain stimulation electrodes undergoing MRIMagnetic Resonance in Medicine, 2022
- MRI‐Related Heating of Implants and Devices: A ReviewJournal of Magnetic Resonance Imaging, 2020
- Anatomical Model Uncertainty for RF Safety Evaluation of Metallic Implants Under MRI ExposureBioelectromagnetics, 2019
- A numerical investigation on the effect of RF coil feed variability on global and local electromagnetic field exposure in human body models at 64 MHzMagnetic Resonance in Medicine, 2017
- Whole‐body and local RF absorption in human models as a function of anatomy and position within 1.5T MR body coilMagnetic Resonance in Medicine, 2013
- Thermal Tissue Damage Model Analyzed for Different Whole‐Body SAR and Scan Durations for Standard MR Body CoilsMagnetic Resonance in Medicine, 2013
- Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer functionJournal of Magnetic Resonance Imaging, 2007
- Heating of metallic implants and instruments induced by gradient switching in a 1.5‐Tesla whole‐body unitJournal of Magnetic Resonance Imaging, 2007
- Estimating radiofrequency power deposition in body NMR imagingMagnetic Resonance in Medicine, 1985