Marie-Elise Jennes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marie-Elise Jennes has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Florian Beuer
Department of Prosthodontics, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Geriatric Dentistry and Craniomandibular Disorders, Berlin, Germany
3 shared publications- Florian Beuer
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
3 shared publications - Franziska Schmidt
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
2 shared publications Jeremias Hey
Department of Prosthetic Dentistry, University School of Dental Medicine, Martin Luther University Halle-Wittenberg, Halle, Germany
2 shared publications- Zhen Mao
Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany
2 shared publications Alexey Unkovskiy
1 shared publication
Latest Publications
- Open Access
- 6 November 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 177
Accuracy of robotic computer-assisted implant surgery in fully edentulous patients: a systematic review and meta-analysis
- 6 November 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 177
Open AccessAccuracy of robotic computer-assisted implant surgery in fully edentulous patients: a systematic review and meta-analysis
- Open Access
- 19 August 2026
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 12 (1) , 40
Prospective clinical study to evaluate the survival of two-piece zirconia implants: a single-center study. 36-month results
Purpose: To evaluate the 36-month survival and clinical outcomes of two-piece zirconia implants restored with screw-retained glass-ceramic crowns on PEKK abutments. Methods: This prospective single-center clinical study evaluated implant survival as the primary outcome, with secondary outcomes including peri-implant soft tissue parameters, marginal bone level changes, and patient-reported outcome measures. Twenty-four patients received single CERALOG Hexalobe two-piece zirconia implants manufactured by ceramic injection molding (CIM) in healed sites. After 6-month submerged healing, implants were restored with provisional screw-retained crowns on PEKK abutments, followed by definitive lithium disilicate crowns (IPS e.max Press) on PEKK abutments secured with titanium abutment screws (25 Ncm). Clinical and radiographic examinations were performed at implant placement, re-entry, definitive loading, and at 12-, 24-, and 36-month follow-ups. Implant survival was analyzed using Kaplan–Meier estimates. Results: Of 23 evaluable implants, nine failed within the first 12 months: six due to failed osseointegration (two at re-entry, three during provisional restoration, one after definitive loading) and three due to implant fracture (one during provisional restoration, two after definitive loading). Kaplan-Meier survival rate was 60.9% (95% CI; 41–81%) at 12 months. No additional failures occurred between 12 and 36 months. Peri-implant soft tissue parameters of surviving implants showed favorable trends (PPD: 2.7 ± 0.7 mm at 12 months, 2.0 ± 0.5 mm at 24 months, 1.9 ± 0.8 mm at 36 months; BOP: 26%, 21%, and 18%, respectively; MGI: 0.38 ± 0.36 at 12 months, 0.40 ± 0.76 at 24 months, 0.21 ± 0.48 at 36 months). At the implant level, peri-implant mucositis was diagnosed in 7 of 13 implants (53.8%) at 36 months; no peri-implantitis was observed throughout the observation period. Mean DIB was 1.9 ± 0.6 mm at definitive loading, 1.6 ± 0.5 mm at 24 months, and 1.5 ± 0.9 mm at 36 months. One abutment screw loosening at 24 months was successfully managed. Patients with surviving implants reported high satisfaction scores (overall satisfaction: 5.0 ± 0.0 at 36 months). Conclusions: The 39.1% early failure rate within the first 12 months was followed by stable marginal bone levels through 36 months in implants that achieved successful osseointegration. However, peri-implant mucositis remained prevalent at 36 months, underlining the need for peri-implant maintenance. The early post-loading period represents the critical determinant of long-term implant survival in this system. Extended follow-up through 60 months is ongoing.
- 19 August 2026
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 12 (1) , 40
Open AccessProspective clinical study to evaluate the survival of two-piece zirconia implants: a single-center study. 36-month results
Purpose: To evaluate the 36-month survival and clinical outcomes of two-piece zirconia implants restored with screw-retained glass-ceramic crowns on PEKK abutments. Methods: This prospective single-center clinical study evaluated implant survival as the primary outcome, with secondary outcomes including peri-implant soft tissue parameters, marginal bone level changes, and patient-reported outcome measures. Twenty-four patients received single CERALOG Hexalobe two-piece zirconia implants manufactured by ceramic injection molding (CIM) in healed sites. After 6-month submerged healing, implants were restored with provisional screw-retained crowns on PEKK abutments, followed by definitive lithium disilicate crowns (IPS e.max Press) on PEKK abutments secured with titanium abutment screws (25 Ncm). Clinical and radiographic examinations were performed at implant placement, re-entry, definitive loading, and at 12-, 24-, and 36-month follow-ups. Implant survival was analyzed using Kaplan–Meier estimates. Results: Of 23 evaluable implants, nine failed within the first 12 months: six due to failed osseointegration (two at re-entry, three during provisional restoration, one after definitive loading) and three due to implant fracture (one during provisional restoration, two after definitive loading). Kaplan-Meier survival rate was 60.9% (95% CI; 41–81%) at 12 months. No additional failures occurred between 12 and 36 months. Peri-implant soft tissue parameters of surviving implants showed favorable trends (PPD: 2.7 ± 0.7 mm at 12 months, 2.0 ± 0.5 mm at 24 months, 1.9 ± 0.8 mm at 36 months; BOP: 26%, 21%, and 18%, respectively; MGI: 0.38 ± 0.36 at 12 months, 0.40 ± 0.76 at 24 months, 0.21 ± 0.48 at 36 months). At the implant level, peri-implant mucositis was diagnosed in 7 of 13 implants (53.8%) at 36 months; no peri-implantitis was observed throughout the observation period. Mean DIB was 1.9 ± 0.6 mm at definitive loading, 1.6 ± 0.5 mm at 24 months, and 1.5 ± 0.9 mm at 36 months. One abutment screw loosening at 24 months was successfully managed. Patients with surviving implants reported high satisfaction scores (overall satisfaction: 5.0 ± 0.0 at 36 months). Conclusions: The 39.1% early failure rate within the first 12 months was followed by stable marginal bone levels through 36 months in implants that achieved successful osseointegration. However, peri-implant mucositis remained prevalent at 36 months, underlining the need for peri-implant maintenance. The early post-loading period represents the critical determinant of long-term implant survival in this system. Extended follow-up through 60 months is ongoing.
- Open Access
- 20 April 2025
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 11 (1) , 1-11
Prospective clinical study to evaluate the success and survival of two-piece zirconia implants: a single-center study. 12-month results
Purpose: To evaluate the survival and success rates of a novel two-piece zirconia implant system restored with screw-retained glass–ceramic crowns over 12 months, including assessment of bone levels, soft tissue parameters, and patient-reported outcome measures. Methods: Twenty-four patients received single two-piece zirconia implants (CERALOG® Hexalobe) in healed sites. After a 6-month healing period, implants received provisional screw-retained crowns on PEKK temporary abutments, followed by definitive lithium disilicate crowns (IPS e.max Press) on PEKK abutments. Clinical and radiographic examinations were performed at implant placement, re-entry, definitive loading, and 12-month follow-up, along with patient-reported outcome measures. Results: The implant survival rate at 12 months was 60.9%. Nine implants were lost: two due to lack of osseointegration at re-entry, four due to mobility after loading, and three due to fractures in the coronal third after loading. Surviving implants showed stable soft tissue parameters with mean probing pocket depths of 2.7 ± 0.7 mm at 12 months. The mean distance from implant shoulder to first bone contact decreased from 1.9 ± 0.6 mm at loading to 1.4 ± 0.6 mm at 12 months. Patients with surviving implants reported high satisfaction scores (4.8 ± 0.4) for function and aesthetics. Conclusions: The two-piece zirconia implant system with screw-retained restorations showed unsatisfactory survival rates. The combination of ceramic implants with screw-retained prosthetic restorations may have contributed to the higher failure rates observed. As a pilot study with a relatively small sample size, these findings should be confirmed by larger multicenter studies to validate these preliminary results.
- 20 April 2025
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 11 (1) , 1-11
Open AccessProspective clinical study to evaluate the success and survival of two-piece zirconia implants: a single-center study. 12-month results
Purpose: To evaluate the survival and success rates of a novel two-piece zirconia implant system restored with screw-retained glass–ceramic crowns over 12 months, including assessment of bone levels, soft tissue parameters, and patient-reported outcome measures. Methods: Twenty-four patients received single two-piece zirconia implants (CERALOG® Hexalobe) in healed sites. After a 6-month healing period, implants received provisional screw-retained crowns on PEKK temporary abutments, followed by definitive lithium disilicate crowns (IPS e.max Press) on PEKK abutments. Clinical and radiographic examinations were performed at implant placement, re-entry, definitive loading, and 12-month follow-up, along with patient-reported outcome measures. Results: The implant survival rate at 12 months was 60.9%. Nine implants were lost: two due to lack of osseointegration at re-entry, four due to mobility after loading, and three due to fractures in the coronal third after loading. Surviving implants showed stable soft tissue parameters with mean probing pocket depths of 2.7 ± 0.7 mm at 12 months. The mean distance from implant shoulder to first bone contact decreased from 1.9 ± 0.6 mm at loading to 1.4 ± 0.6 mm at 12 months. Patients with surviving implants reported high satisfaction scores (4.8 ± 0.4) for function and aesthetics. Conclusions: The two-piece zirconia implant system with screw-retained restorations showed unsatisfactory survival rates. The combination of ceramic implants with screw-retained prosthetic restorations may have contributed to the higher failure rates observed. As a pilot study with a relatively small sample size, these findings should be confirmed by larger multicenter studies to validate these preliminary results.
- Open Access
- 26 March 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (5) , 584-592
The influence of ZnO content in YSZ-ZnO composite ceramics on bacterial growth and cell behaviour for the prevention of peri-implant inflammation
- 26 March 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (5) , 584-592
Open AccessThe influence of ZnO content in YSZ-ZnO composite ceramics on bacterial growth and cell behaviour for the prevention of peri-implant inflammation
- 30 July 2022
- Published by Elsevier in Dental Materials
- Vol. 38 (9) , 1532-1546
Response of human gingival keratinocytes to hybrid CAD/CAM material eluates
- 30 July 2022
- Published by Elsevier in Dental Materials
- Vol. 38 (9) , 1532-1546
Response of human gingival keratinocytes to hybrid CAD/CAM material eluates
- Open Access
- 28 June 2022
- Published by Wiley in Clinical Oral Implants Research
- Vol. 33 (S23) , 125-136
Effectiveness of soft tissue augmentation procedures for coverage of buccal soft tissue dehiscence around dental implants: A systematic review
Objective: This systematic review evaluated the effectiveness of soft tissue augmentation procedures for complete coverage and mean coverage of buccal soft tissue dehiscence (BSTD) in patients with implant‐supported restorations.Methods: Three databases were surveyed for randomized (RCTs), non‐randomized controlled clinical trials (CCTs), cohort studies, case–control studies, and case series with a minimum of five patients per control or test group. Studies dealing with soft tissue augmentation procedures to cover BSTD—occurring during implant function and not due to the result of peri‐implantitis—were included. Risk of bias was evaluated with RoB 2 or the National Institutes of Health's Quality Assessment. Whenever possible, exploratory meta‐analyses were performed to evaluate weighted mean effects (WME) for the different outcomes. The primary outcomes were the percentage of complete coverage and mean coverage of BSTD.Results: Seven articles were included. Only one study was a RCT, with a high risk of bias. Meta‐analyses showed that after 1 year (2 studies, n = 36 patients; WME = 70; 95% confidence interval [CI] = 50; 90; p = .23) as well as after 5 years (3 studies, n = 54 patients; WME = 70; 95%; CI = 60; 80; p = .44), complete coverage of BSTD could be achieved in 70% of the cases.Conclusion: Based on limited evidence, it can be concluded that BSTD can be substantially reduced with the use of soft tissue augmentation procedures. Further research with comparative trials using larger samples and longer follow‐up periods is needed to study the stability of soft tissues in the long term.
- 28 June 2022
- Published by Wiley in Clinical Oral Implants Research
- Vol. 33 (S23) , 125-136
Open AccessEffectiveness of soft tissue augmentation procedures for coverage of buccal soft tissue dehiscence around dental implants: A systematic review
Objective: This systematic review evaluated the effectiveness of soft tissue augmentation procedures for complete coverage and mean coverage of buccal soft tissue dehiscence (BSTD) in patients with implant‐supported restorations.Methods: Three databases were surveyed for randomized (RCTs), non‐randomized controlled clinical trials (CCTs), cohort studies, case–control studies, and case series with a minimum of five patients per control or test group. Studies dealing with soft tissue augmentation procedures to cover BSTD—occurring during implant function and not due to the result of peri‐implantitis—were included. Risk of bias was evaluated with RoB 2 or the National Institutes of Health's Quality Assessment. Whenever possible, exploratory meta‐analyses were performed to evaluate weighted mean effects (WME) for the different outcomes. The primary outcomes were the percentage of complete coverage and mean coverage of BSTD.Results: Seven articles were included. Only one study was a RCT, with a high risk of bias. Meta‐analyses showed that after 1 year (2 studies, n = 36 patients; WME = 70; 95% confidence interval [CI] = 50; 90; p = .23) as well as after 5 years (3 studies, n = 54 patients; WME = 70; 95%; CI = 60; 80; p = .44), complete coverage of BSTD could be achieved in 70% of the cases.Conclusion: Based on limited evidence, it can be concluded that BSTD can be substantially reduced with the use of soft tissue augmentation procedures. Further research with comparative trials using larger samples and longer follow‐up periods is needed to study the stability of soft tissues in the long term.
- 1 June 2022
- Vol. 53 (6) , 534-545
Esthetic and functional rehabilitation of severe facial asymmetry and dental attrition in a patient with hemifacial microsomia: an interdisciplinary treatment outcome
The treatment management of patients with hemifacial microso- mia (HM) includes both surgical and nonsurgical approaches and depends primarily on the degree of deformity of the facial and skeletal structures. In this context, the combined efforts of the maxillofacial surgeon, the orthodontist, and the prosthodontist are essential for a satisfactory functional and esthetic outcome. Case presentation: A 31-year -old man presented with a chief complaint of facial asymmetry. The patient had been diagnosed with HM on the right side, with severe external ear deformity, and hypoplasia of the facial muscles and the zygomatic bone. The intra- oral examination showed a Class I molar and canine relationship with a reduced horizontal overlap and an occlusal plane canting. The maxillary anterior teeth were severely worn due to traumatic occlusion. Orthodontic treatment in conjunction with combined orthognathic surgery was planned to address the facial asymmetry. Ramus distraction osteogenesis was carried out, followed by con- ventional presurgical orthodontic treatment. The treatment was completed by prosthetic rehabilitation for the reconstruction of the maxillary teeth and fine occlusal adjustment. Conclusion: The cooperation between the orthodontist, surgeon, and prostho- dontist becomes indispensable when treating complex cases of HM. An interdisciplinary approach should be adopted from the start of treatment, promoting integrated customized care.
- 1 June 2022
- Vol. 53 (6) , 534-545
Esthetic and functional rehabilitation of severe facial asymmetry and dental attrition in a patient with hemifacial microsomia: an interdisciplinary treatment outcome
The treatment management of patients with hemifacial microso- mia (HM) includes both surgical and nonsurgical approaches and depends primarily on the degree of deformity of the facial and skeletal structures. In this context, the combined efforts of the maxillofacial surgeon, the orthodontist, and the prosthodontist are essential for a satisfactory functional and esthetic outcome. Case presentation: A 31-year -old man presented with a chief complaint of facial asymmetry. The patient had been diagnosed with HM on the right side, with severe external ear deformity, and hypoplasia of the facial muscles and the zygomatic bone. The intra- oral examination showed a Class I molar and canine relationship with a reduced horizontal overlap and an occlusal plane canting. The maxillary anterior teeth were severely worn due to traumatic occlusion. Orthodontic treatment in conjunction with combined orthognathic surgery was planned to address the facial asymmetry. Ramus distraction osteogenesis was carried out, followed by con- ventional presurgical orthodontic treatment. The treatment was completed by prosthetic rehabilitation for the reconstruction of the maxillary teeth and fine occlusal adjustment. Conclusion: The cooperation between the orthodontist, surgeon, and prostho- dontist becomes indispensable when treating complex cases of HM. An interdisciplinary approach should be adopted from the start of treatment, promoting integrated customized care.
- 1 January 2022
- Vol. 25 (1) , 9-16
In vivo full-arch accuracy of intraoral scanners: a narrative review
Aim: The present narrative review aims to provide an overview of the in vivo accuracy of full-arch scans performed with currently used intraoral devices and to compare different methods for the determination of in vivo accuracy. Materials and methods: An electronic search was performed with the PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), and Web of Science databases, including articles from 2015 to 2020. Specific search strategies were developed for each platform. Results: The final search resulted in five published articles. The mean values of trueness and precision of the examined scanners ranged from 12.9 to 80.01 mu m for trueness and from 42.9 to 86.0 mu m for precision in full-arch dentition. Not all studies evaluated both trueness and precision. Furthermore, the methods and references for determining the in vivo accuracy proved to be very different. Conclusion: To date, no scientific consensus on the required accuracy of in vivo full-arch scans has been reached and published. Due to the small number of studies on the in vivo accuracy of full-arch scans, further studies should be conducted in this area. In addition, a concept for a valid reference that can be scanned both extraorally and intraorally should be developed.
- 1 January 2022
- Vol. 25 (1) , 9-16
In vivo full-arch accuracy of intraoral scanners: a narrative review
Aim: The present narrative review aims to provide an overview of the in vivo accuracy of full-arch scans performed with currently used intraoral devices and to compare different methods for the determination of in vivo accuracy. Materials and methods: An electronic search was performed with the PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), and Web of Science databases, including articles from 2015 to 2020. Specific search strategies were developed for each platform. Results: The final search resulted in five published articles. The mean values of trueness and precision of the examined scanners ranged from 12.9 to 80.01 mu m for trueness and from 42.9 to 86.0 mu m for precision in full-arch dentition. Not all studies evaluated both trueness and precision. Furthermore, the methods and references for determining the in vivo accuracy proved to be very different. Conclusion: To date, no scientific consensus on the required accuracy of in vivo full-arch scans has been reached and published. Due to the small number of studies on the in vivo accuracy of full-arch scans, further studies should be conducted in this area. In addition, a concept for a valid reference that can be scanned both extraorally and intraorally should be developed.
- Open Access
- 5 November 2021
- Published by MDPI AG in Antibiotics
- Vol. 10 (11) , 1350
Antibacterial Effects of Modified Implant Abutment Surfaces for the Prevention of Peri-Implantitis—A Systematic Review
The aim of the present study was to systematically review studies investigating antibacterial implant abutment surfaces or coatings, which may suppress bacterial growth to prevent plaque-induced peri-implant inflammatory disease. Data were collected after identification of case, assay/laboratory procedure, predicate/reference standard and outcome (CAPO). Seven hundred and twenty (720) records were identified through data base searching. After screening nine publications fulfilled inclusion criteria and were included. The following surfaces/coatings showed antibacterial properties: Electrochemical surface modification of titanium by the anodic spark deposition technique; doxycycline coating by cathodic polarization; silver coating by DC plasma sputter; titanium nitride; zirconium nitride and microwave assistant nano silver coating. Since the current state of the literature is rather descriptive, a meta-analysis was not performed. While several abutment coatings showed to have antibacterial capacity, some of them also influenced the behavior of investigated human cells. None of the studies investigated the long-term effect of surface modifications. Since surface changes are the main contributing factor in the development of antibacterial effects, the biodegradation behavior must be characterized to understand its durability. To date there is no effective structure, material or strategy to avoid peri-implant inflammation used as clinical routine. Furthermore, clinical studies are scarce.
- 5 November 2021
- Published by MDPI AG in Antibiotics
- Vol. 10 (11) , 1350
Open AccessAntibacterial Effects of Modified Implant Abutment Surfaces for the Prevention of Peri-Implantitis—A Systematic Review
The aim of the present study was to systematically review studies investigating antibacterial implant abutment surfaces or coatings, which may suppress bacterial growth to prevent plaque-induced peri-implant inflammatory disease. Data were collected after identification of case, assay/laboratory procedure, predicate/reference standard and outcome (CAPO). Seven hundred and twenty (720) records were identified through data base searching. After screening nine publications fulfilled inclusion criteria and were included. The following surfaces/coatings showed antibacterial properties: Electrochemical surface modification of titanium by the anodic spark deposition technique; doxycycline coating by cathodic polarization; silver coating by DC plasma sputter; titanium nitride; zirconium nitride and microwave assistant nano silver coating. Since the current state of the literature is rather descriptive, a meta-analysis was not performed. While several abutment coatings showed to have antibacterial capacity, some of them also influenced the behavior of investigated human cells. None of the studies investigated the long-term effect of surface modifications. Since surface changes are the main contributing factor in the development of antibacterial effects, the biodegradation behavior must be characterized to understand its durability. To date there is no effective structure, material or strategy to avoid peri-implant inflammation used as clinical routine. Furthermore, clinical studies are scarce.
- Open Access
- 4 June 2021
- Published by Springer Nature in BMC Oral Health
- Vol. 21 (1) , 1-9
Gender- and age-related differences in the width of attached gingiva and clinical crown length in anterior teeth
Background: The anatomical features of the gingiva and the clinical crowns and their interrelation, especially in aesthetically and functionally demanding areas, are important in complex dental or implant-retained prosthetic rehabilitations. This observational cross-sectional study was designed to evaluate gender- and age-related differences in the width of attached gingiva (WAG), the clinical crown length (CCL), and their interrelation in the anterior teeth to determine the relationship between the pink and white aesthetics. Methods: Eighty (54 females, 26 males) fully dentate Caucasian participants between the ages of 20 and 25 years and 36 probands (23 females, 13 males) between the ages of 45 and 55 years were included in the present study. The CCL of the maxillary and mandibular canines, as well as the central incisors of the maxilla and mandible, were determined with a dental sliding caliper measuring from the middle margin of the gingiva at its deepest point to the incisal edge. The clinical investigation of the WAG was performed by inserting a periodontal probe into the gingival sulcus in the middle of the buccal surface to firstly measure the probing pocket depth. The distance between the gingival margin and mucogingival junction (MGJ) was then measured with a Beerendonk sliding caliper in the middle of the labial curvature, and the clinical WAG was determined by subtraction of the measured probing depth. For the statistical analysis, the Mann–Whitney U test, the Wilcoxon-Test, the Spearman’s rank correlation, and a two-factorial non-parametric analysis were used. Results: There was no correlation between the CCL and the WAG in a healthy periodontium. Gender influenced the CCL, with men having significantly longer teeth than women in both maxilla (P ≤ 0.01) and mandible (P ≤ 0.05). Age did not influence the CCL significantly neither in the upper (P = 0.06) nor in the lower jaw (P = 0.33). Gender did not show to have a significant influence on the WAG of maxilla (P = 0.69) and mandible (P = 0.26). But differences in the WAG between young and old participants were observed in both upper (P ≤ 0.01) and lower jaw (P ≤ 0.05). Conclusion: The present observational study demonstrated that the mean values of cohorts with mixed age groups and genders should not be considered when attempting to determine the ideal relationships between the pink and white aesthetics since the statistical analyses showed significant differences between different age groups and genders.
- 4 June 2021
- Published by Springer Nature in BMC Oral Health
- Vol. 21 (1) , 1-9
Open AccessGender- and age-related differences in the width of attached gingiva and clinical crown length in anterior teeth
Background: The anatomical features of the gingiva and the clinical crowns and their interrelation, especially in aesthetically and functionally demanding areas, are important in complex dental or implant-retained prosthetic rehabilitations. This observational cross-sectional study was designed to evaluate gender- and age-related differences in the width of attached gingiva (WAG), the clinical crown length (CCL), and their interrelation in the anterior teeth to determine the relationship between the pink and white aesthetics. Methods: Eighty (54 females, 26 males) fully dentate Caucasian participants between the ages of 20 and 25 years and 36 probands (23 females, 13 males) between the ages of 45 and 55 years were included in the present study. The CCL of the maxillary and mandibular canines, as well as the central incisors of the maxilla and mandible, were determined with a dental sliding caliper measuring from the middle margin of the gingiva at its deepest point to the incisal edge. The clinical investigation of the WAG was performed by inserting a periodontal probe into the gingival sulcus in the middle of the buccal surface to firstly measure the probing pocket depth. The distance between the gingival margin and mucogingival junction (MGJ) was then measured with a Beerendonk sliding caliper in the middle of the labial curvature, and the clinical WAG was determined by subtraction of the measured probing depth. For the statistical analysis, the Mann–Whitney U test, the Wilcoxon-Test, the Spearman’s rank correlation, and a two-factorial non-parametric analysis were used. Results: There was no correlation between the CCL and the WAG in a healthy periodontium. Gender influenced the CCL, with men having significantly longer teeth than women in both maxilla (P ≤ 0.01) and mandible (P ≤ 0.05). Age did not influence the CCL significantly neither in the upper (P = 0.06) nor in the lower jaw (P = 0.33). Gender did not show to have a significant influence on the WAG of maxilla (P = 0.69) and mandible (P = 0.26). But differences in the WAG between young and old participants were observed in both upper (P ≤ 0.01) and lower jaw (P ≤ 0.05). Conclusion: The present observational study demonstrated that the mean values of cohorts with mixed age groups and genders should not be considered when attempting to determine the ideal relationships between the pink and white aesthetics since the statistical analyses showed significant differences between different age groups and genders.