Ahmed Essadki
Research Subjects
Ahmed Essadki has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Tamou Nasser
Research Center of Engineering and Health Sciences and Technologies, Higher National School of Computer Science and Systems Analysis, Mohammed V University, Rabat, Morocco
39 shared publications- Hind Elaimani
Institut Supérieur d’Ingénierie et des Affaires (ISGA Rabat)
8 shared publications Mohammed Fdaili
Mohammed V University-Rabat-Morocco,ERERA, Research Center in Sciences and Technologies of Engineering and Health (STIS). Higher Normal School of Technical Education (ENSET)
8 shared publications- Noureddine Elmouhi
Institut Supérieur d’Ingénierie et des Affaires (ISGA Rabat)
8 shared publications - Mohamed Cherkaoui
Department of Electrical Engineering, Mohammed V University Mohammadia School of Engineers, Rabat, Morocco
7 shared publications - Mohamed Nadour
Research Center of Engineering and Health Science and Technologies (STIS), High Normal School of Technical Education (ENSET), Mohammed V University, Rabat, Morocco
7 shared publications
Latest Publications
- Open Access
- 1 September 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 14 (3) , 1382-1393
Fault tolerant control for DFIG wind turbine controlled by ADRC and optimized by genetic algorithm
This research work deals with the modelling, control and simulation of a wind turbine based on the doubly fed induction generator (DFIG) in the current sensor’s failure event. We present in the first time the model of the wind energy conversion system based on the DFIG and the control by active disturbances rejection control (ADRC) optimized by genetic algorithm. Particular focus is directed towards on a technique for detection, identification, isolation and reconfiguration of current sensor signals after failure. The combination of the two preceding techniques makes it possible to have a fault tolerant control to sensor faults which ensures continuity of service in all circumstances. The robustness of the proposed technique is tested under the MATLAB/Simulink environment.
- 1 September 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 14 (3) , 1382-1393
Open AccessFault tolerant control for DFIG wind turbine controlled by ADRC and optimized by genetic algorithm
This research work deals with the modelling, control and simulation of a wind turbine based on the doubly fed induction generator (DFIG) in the current sensor’s failure event. We present in the first time the model of the wind energy conversion system based on the DFIG and the control by active disturbances rejection control (ADRC) optimized by genetic algorithm. Particular focus is directed towards on a technique for detection, identification, isolation and reconfiguration of current sensor signals after failure. The combination of the two preceding techniques makes it possible to have a fault tolerant control to sensor faults which ensures continuity of service in all circumstances. The robustness of the proposed technique is tested under the MATLAB/Simulink environment.
- Open Access
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Robust control of wind turbine based on doubly-fed induction generator optimized by genetic algorithm
In this research paper we will cover the study of the modelling and the control methods of the variable speed wind turbine based on doubly-fed induction generator (DFIG). It represents the most stressed structure given its distinctive characteristics. To control the electrical powers generated by this system independently, the vector control with the stator flux orientation is founded according to two techniques: i) the control of the powers by the backstepping technique and ii) the robust control based on the active disturbances rejection control. After the synthesis of the controllers of those two methods, their performances will be tested and compared to evaluate their effectiveness. We are mainly interested in the robustness test of the two control strategies with respect to the internal parameters’ fluctuation of the generator. The computing of the different parameters regulators of these two strategies is carried out using a genetic algorithm. This computing method makes it possible to arrive at an optimal solution of the DFIG power control. The different parts are simulated using MATLAB/Simulink environment.
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Open AccessRobust control of wind turbine based on doubly-fed induction generator optimized by genetic algorithm
In this research paper we will cover the study of the modelling and the control methods of the variable speed wind turbine based on doubly-fed induction generator (DFIG). It represents the most stressed structure given its distinctive characteristics. To control the electrical powers generated by this system independently, the vector control with the stator flux orientation is founded according to two techniques: i) the control of the powers by the backstepping technique and ii) the robust control based on the active disturbances rejection control. After the synthesis of the controllers of those two methods, their performances will be tested and compared to evaluate their effectiveness. We are mainly interested in the robustness test of the two control strategies with respect to the internal parameters’ fluctuation of the generator. The computing of the different parameters regulators of these two strategies is carried out using a genetic algorithm. This computing method makes it possible to arrive at an optimal solution of the DFIG power control. The different parts are simulated using MATLAB/Simulink environment.
- Open Access
- 1 January 2022
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 29 (1) , 120-132
Adaptive doubly fed induction generator’s control driven wind turbine using luenberger observer optimized by genetic algorithm
The calculation of control parameters for a system control method is based on the model of the system with assumed fixed internal parameters. However, these parameters can vary greatly due to several phenomena. This paper presents an adapted control of a doubly fed induction generator machine robust against the rotor resistance variations of the machine used as a generator in wind energy conversion systems. The adaptation is ensured by a system allowing to identify in real time the value of the resistance, the system used is mainly based on a Luenberger observer. The conversion system is divided into two parts, the first mechanical part containing the turbine and the gearbox, the second electrical one consisting of a double fed induction generator, linked on the stator side directly to the grid, and on the rotor, side linked to the grid through two power electronics converters interposed with a direct current (DC) link. The machine-side converter is used to control the active and reactive powers, and the second on the grid side is used to control the DC link voltage. The converters are controlled by the sliding mode strategy, and the validity of the methods is checked by simulation using MATLAB/Simulink.
- 1 January 2022
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 29 (1) , 120-132
Open AccessAdaptive doubly fed induction generator’s control driven wind turbine using luenberger observer optimized by genetic algorithm
The calculation of control parameters for a system control method is based on the model of the system with assumed fixed internal parameters. However, these parameters can vary greatly due to several phenomena. This paper presents an adapted control of a doubly fed induction generator machine robust against the rotor resistance variations of the machine used as a generator in wind energy conversion systems. The adaptation is ensured by a system allowing to identify in real time the value of the resistance, the system used is mainly based on a Luenberger observer. The conversion system is divided into two parts, the first mechanical part containing the turbine and the gearbox, the second electrical one consisting of a double fed induction generator, linked on the stator side directly to the grid, and on the rotor, side linked to the grid through two power electronics converters interposed with a direct current (DC) link. The machine-side converter is used to control the active and reactive powers, and the second on the grid side is used to control the DC link voltage. The converters are controlled by the sliding mode strategy, and the validity of the methods is checked by simulation using MATLAB/Simulink.
- Open Access
- 15 May 2020
- Published by Hindawi Limited in Mathematical Problems in Engineering
- Vol. 2020, 1-12
Robust Multiobjective Model Predictive Control with Computation Delay Compensation for Electric Vehicle Applications Using PMSM with Multilevel Inverter
The Three-Level Neutral-Point-Clamped (3L-NPC) inverter fed Permanent Magnet Synchronous Motor (PMSM) drive is an attractive configuration for high performance Electric Vehicle (EV) applications. For such configuration, due to their high performances, the Finite-Control-Set Model Predictive Control (FCS-MPC) is a very attractive control solution. The FCS-MPC scheme is based on the prediction of the future behavior of the controlled variables using the dynamic model of PMSM and the discrete nature of the 3L-NPC inverter. However, the parametric uncertainties and time-varying parameters affect the FCS-MPC algorithm performances. In this paper, robust FCS-MPC controls based on “dynamic error correction” (DEC) and “modified revised prediction” (MRP) are proposed to improve the FCS-MPC robustness without affecting the controller performances and complexity. The proposed strategies are improved also by multiobjective (MO) algorithm optimization and computation delay compensation. The simulation results included prove the performance in robustness and efficiency of the proposed robust FCS-MPC-DEC.
- 15 May 2020
- Published by Hindawi Limited in Mathematical Problems in Engineering
- Vol. 2020, 1-12
Open AccessRobust Multiobjective Model Predictive Control with Computation Delay Compensation for Electric Vehicle Applications Using PMSM with Multilevel Inverter
The Three-Level Neutral-Point-Clamped (3L-NPC) inverter fed Permanent Magnet Synchronous Motor (PMSM) drive is an attractive configuration for high performance Electric Vehicle (EV) applications. For such configuration, due to their high performances, the Finite-Control-Set Model Predictive Control (FCS-MPC) is a very attractive control solution. The FCS-MPC scheme is based on the prediction of the future behavior of the controlled variables using the dynamic model of PMSM and the discrete nature of the 3L-NPC inverter. However, the parametric uncertainties and time-varying parameters affect the FCS-MPC algorithm performances. In this paper, robust FCS-MPC controls based on “dynamic error correction” (DEC) and “modified revised prediction” (MRP) are proposed to improve the FCS-MPC robustness without affecting the controller performances and complexity. The proposed strategies are improved also by multiobjective (MO) algorithm optimization and computation delay compensation. The simulation results included prove the performance in robustness and efficiency of the proposed robust FCS-MPC-DEC.
- Open Access
- 29 April 2020
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2020, 1-16
Coordinated Control Using Backstepping of DFIG-Based Wind Turbine for Frequency Regulation in High Wind Energy Penetrated System
The expansion of renewable generation has raised some red flags in terms of power system stability, control, and management. For instance, unlike traditional synchronous energy sources, the doubly-fed induction generator- (DFIG-) based wind turbines (WTs) do not instinctively act against frequency deviations. In fact, the power electronics interfacing the generator, merely controlled to warrant maximum wind power conversion, make its output power and mechanical speed immune to the characteristics of the electric network frequency. Moreover, significant wind power penetration (WPP) promotes the retirement of many traditional generation groups, consequently curtailing the power system corresponding inertia and displacing the primary reserves that are essential to retain the frequency within an acceptable range of variation. This paper explores different control approaches, using backstepping, allowing DFIG-based WTs to engage actively in frequency regulation using a coordinated control of the rotor speed and pitch angle to regulate the system during both partial- and full-load operation modes. The first method momentarily discharges part of the kinetic energy stored in the WT spinning masses, and the second method follows a deloaded operation characteristic, so as to keep a specific power reserve that can be automatically activated at the events of frequency excursions. A study case considering an isolated power system that consists of synchronous generators, DFIG-based wind farm, static load, and a sudden frequency disturbance was performed. The simulation result in a Matlab/Simulink environment highlights the robustness and capability of the coordinated control scheme to furnish, under variant operation conditions, active power aid, consequently lifting the frequency nadir up to a superior level than that obtained with 0% wind power penetration in the system.
- 29 April 2020
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2020, 1-16
Open AccessCoordinated Control Using Backstepping of DFIG-Based Wind Turbine for Frequency Regulation in High Wind Energy Penetrated System
The expansion of renewable generation has raised some red flags in terms of power system stability, control, and management. For instance, unlike traditional synchronous energy sources, the doubly-fed induction generator- (DFIG-) based wind turbines (WTs) do not instinctively act against frequency deviations. In fact, the power electronics interfacing the generator, merely controlled to warrant maximum wind power conversion, make its output power and mechanical speed immune to the characteristics of the electric network frequency. Moreover, significant wind power penetration (WPP) promotes the retirement of many traditional generation groups, consequently curtailing the power system corresponding inertia and displacing the primary reserves that are essential to retain the frequency within an acceptable range of variation. This paper explores different control approaches, using backstepping, allowing DFIG-based WTs to engage actively in frequency regulation using a coordinated control of the rotor speed and pitch angle to regulate the system during both partial- and full-load operation modes. The first method momentarily discharges part of the kinetic energy stored in the WT spinning masses, and the second method follows a deloaded operation characteristic, so as to keep a specific power reserve that can be automatically activated at the events of frequency excursions. A study case considering an isolated power system that consists of synchronous generators, DFIG-based wind farm, static load, and a sudden frequency disturbance was performed. The simulation result in a Matlab/Simulink environment highlights the robustness and capability of the coordinated control scheme to furnish, under variant operation conditions, active power aid, consequently lifting the frequency nadir up to a superior level than that obtained with 0% wind power penetration in the system.
- Open Access
- 30 March 2020
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2020, 1-14
A Novel Adaptive Active Disturbance Rejection Control Strategy to Improve the Stability and Robustness for a Wind Turbine Using a Doubly Fed Induction Generator
A novel and robust active disturbance rejection control (ADRC) strategy for variable speed wind turbine systems using a doubly fed induction generator (DFIG) is presented in this paper. The DFIG is directly connected to the main utility grid by stator, and its rotor is connected through a back-to-back three phase power converter (AC/DC/AC). Due to the acoustic nature of wind and to ensure capturing maximum energy, a control strategy to extract the available maximum power from the wind turbine by using a maximum power point tracking (MPPT) algorithm is presented. Moreover, a pitch actuator system is used to control the blades’ pitch angle of the wind turbine in order to not exceed the wind turbine rated power value in case of strong wind speeds. Furthermore, the rotor-side converter is used to control the active and reactive powers generated by the DFIG. However, the grid-side converter is used to control the currents injected into the utility grid as well as to regulate the DC-link voltage. This paper aims to study and develop two control strategies for wind turbine system control: classical control by proportional integral (PI) and the proposed linear active disturbance rejection control (LADRC). The main purpose here is to compare and evaluate the dynamical performances and sensitivity of these controllers to the DFIG parameter variation. Therefore, a series of simulations were carried out in the MATLAB/Simulink environment, and the obtained results have shown the effectiveness of the proposed strategy in terms of efficiency, rapidity, and robustness to internal and external disturbances.
- 30 March 2020
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2020, 1-14
Open AccessA Novel Adaptive Active Disturbance Rejection Control Strategy to Improve the Stability and Robustness for a Wind Turbine Using a Doubly Fed Induction Generator
A novel and robust active disturbance rejection control (ADRC) strategy for variable speed wind turbine systems using a doubly fed induction generator (DFIG) is presented in this paper. The DFIG is directly connected to the main utility grid by stator, and its rotor is connected through a back-to-back three phase power converter (AC/DC/AC). Due to the acoustic nature of wind and to ensure capturing maximum energy, a control strategy to extract the available maximum power from the wind turbine by using a maximum power point tracking (MPPT) algorithm is presented. Moreover, a pitch actuator system is used to control the blades’ pitch angle of the wind turbine in order to not exceed the wind turbine rated power value in case of strong wind speeds. Furthermore, the rotor-side converter is used to control the active and reactive powers generated by the DFIG. However, the grid-side converter is used to control the currents injected into the utility grid as well as to regulate the DC-link voltage. This paper aims to study and develop two control strategies for wind turbine system control: classical control by proportional integral (PI) and the proposed linear active disturbance rejection control (LADRC). The main purpose here is to compare and evaluate the dynamical performances and sensitivity of these controllers to the DFIG parameter variation. Therefore, a series of simulations were carried out in the MATLAB/Simulink environment, and the obtained results have shown the effectiveness of the proposed strategy in terms of efficiency, rapidity, and robustness to internal and external disturbances.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Power Smoothing Control of DFIG Based Wind Turbine using Flywheel Energy Storage System
In this paper, we present coordinated control strategies of a flywheel energy storage system (FESS) and a doubly fed induction generator (DFIG) in wind energy conversion application. The general aim is to enhance the wind energy conversion system's capability to participate in ancillary services. The overall system control relies on the nonlinear backstepping approach applied, firstly, to the rotor side converter to regulate stator active and reactive powers. Then, to the grid side converter to regulate the DC link voltage and the rotor reactive power. Then finally, to the flywheel side converter allowing the FESS to serve as a buffer used to smooth the undesirable wind-induced output power fluctuations. A fuzzy logic supervisor is proposed to maintain the FESS within its operating limits. Numerical simulation in Matlab/Simulink demonstrates the effectiveness of the presented control strategies in terms of stability, tracking behavior and out power quality improvement.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Power Smoothing Control of DFIG Based Wind Turbine using Flywheel Energy Storage System
In this paper, we present coordinated control strategies of a flywheel energy storage system (FESS) and a doubly fed induction generator (DFIG) in wind energy conversion application. The general aim is to enhance the wind energy conversion system's capability to participate in ancillary services. The overall system control relies on the nonlinear backstepping approach applied, firstly, to the rotor side converter to regulate stator active and reactive powers. Then, to the grid side converter to regulate the DC link voltage and the rotor reactive power. Then finally, to the flywheel side converter allowing the FESS to serve as a buffer used to smooth the undesirable wind-induced output power fluctuations. A fuzzy logic supervisor is proposed to maintain the FESS within its operating limits. Numerical simulation in Matlab/Simulink demonstrates the effectiveness of the presented control strategies in terms of stability, tracking behavior and out power quality improvement.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Adaptive Fuzzy-PI Control of Wind Energy Conversion System Based DFIG Under Voltage Dip
The Proportional-Integral (PI) and Fuzzy Logic Controllers (FLC) cannot deal accurately with the system variation. To overcome the drawbacks of PI and FLC regulators, the Adaptive Fuzzy-PI Controllers (AFPICs) are configured. This paper presents a comparison between three different controllers based control methodology for Variable Speed Wind Energy Conversion Systems (WECSs) by means of Doubly Fed Induction Generator (DFIG). Artificial Intelligence (AI) based FLCs is performed to improve the system efficiency and performance under Small Disturbance (SD) and Large Disturbance (LD) cases. To test the PI, FLC, and AFPIC robustness, simulations are done during abrupt wind speed variation (SD), and voltage dip fault (LD). The simulation results show that the proposed AFPIC delivers improved power control, better response rise time, reduced overshoot, undershoot, and settling time compared to classical PI and Fuzzy controllers. The proposed control is proved by simulation using Matlab/Simulink-R2016b.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Adaptive Fuzzy-PI Control of Wind Energy Conversion System Based DFIG Under Voltage Dip
The Proportional-Integral (PI) and Fuzzy Logic Controllers (FLC) cannot deal accurately with the system variation. To overcome the drawbacks of PI and FLC regulators, the Adaptive Fuzzy-PI Controllers (AFPICs) are configured. This paper presents a comparison between three different controllers based control methodology for Variable Speed Wind Energy Conversion Systems (WECSs) by means of Doubly Fed Induction Generator (DFIG). Artificial Intelligence (AI) based FLCs is performed to improve the system efficiency and performance under Small Disturbance (SD) and Large Disturbance (LD) cases. To test the PI, FLC, and AFPIC robustness, simulations are done during abrupt wind speed variation (SD), and voltage dip fault (LD). The simulation results show that the proposed AFPIC delivers improved power control, better response rise time, reduced overshoot, undershoot, and settling time compared to classical PI and Fuzzy controllers. The proposed control is proved by simulation using Matlab/Simulink-R2016b.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Efficient Model Predictive Current Control Algorithm for Grid-Connected Multi-Level Inverter with Computational Delay Compensation
This paper proposes an efficient model predictive current control (MPC) algorithms for grid-connected multi-level (ML) inverter. The proposed algorithm utilizes the discrete-time model to predict the future behavior of the grid connected inverter (GCI) to fulfil the control objectives: fast dynamic and low ripples of the grid current, balancing of the capacitor voltages and minimizing the switching number. These threes control objectives are incorporated in single cost function calculated and evaluated ,for each switching state S abc opt available in the inverter, to generate the optimal switching state applied directly to the inverter. Moreover, a considerable computational delay is required to generate S abc opt . Furthermore, the contributions of the paper is not only the compensation of the computational delay using a long horizon prediction approach, but also using the three-level neutral point clamped (3L-NPC) inverter to provide a low ripples grid current and decrease the control complexity. Finally, the efficiency of the proposed compensation demonstrated through simulations results.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Efficient Model Predictive Current Control Algorithm for Grid-Connected Multi-Level Inverter with Computational Delay Compensation
This paper proposes an efficient model predictive current control (MPC) algorithms for grid-connected multi-level (ML) inverter. The proposed algorithm utilizes the discrete-time model to predict the future behavior of the grid connected inverter (GCI) to fulfil the control objectives: fast dynamic and low ripples of the grid current, balancing of the capacitor voltages and minimizing the switching number. These threes control objectives are incorporated in single cost function calculated and evaluated ,for each switching state S abc opt available in the inverter, to generate the optimal switching state applied directly to the inverter. Moreover, a considerable computational delay is required to generate S abc opt . Furthermore, the contributions of the paper is not only the compensation of the computational delay using a long horizon prediction approach, but also using the three-level neutral point clamped (3L-NPC) inverter to provide a low ripples grid current and decrease the control complexity. Finally, the efficiency of the proposed compensation demonstrated through simulations results.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control Strategies for DFIG-based Wind Turbine Systems Contributing to LVRT improvement and Grid Primary Frequency Adjustment
According to the new technical requirements and standards proposed by the grid operator, wind turbine systems (WTSs) based on doubly-fed induction generator (DFIG) must participate in power system management in the case of grid disturbances such as voltage dip and frequency regulation. Moreover, all WTSs must contribute to voltage and frequency support during and after grid failures. In this paper, the implementation of low voltage ride through (LVRT) and inertial response control based on sliding mode controllers (SMC) to avoid the disconnection of WTS from the grid during faults are investigated. The first strategy consists of keeping the stator flux in a required level to ensure the DFIG's magnetization, and the insertion of the crowbar resistors in the rotor circuits to limit the rotor and stator currents and the DC bus voltage during voltage dip. The second strategy permits to create an artificial inertial response during frequency drop by means of the kinetic energy stored in the WTS' rotating masses. The aim of this strategy is to contribute in the network frequency stabilization and, therefore, the need for additional power afforded by conventional generators.
- 1 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Control Strategies for DFIG-based Wind Turbine Systems Contributing to LVRT improvement and Grid Primary Frequency Adjustment
According to the new technical requirements and standards proposed by the grid operator, wind turbine systems (WTSs) based on doubly-fed induction generator (DFIG) must participate in power system management in the case of grid disturbances such as voltage dip and frequency regulation. Moreover, all WTSs must contribute to voltage and frequency support during and after grid failures. In this paper, the implementation of low voltage ride through (LVRT) and inertial response control based on sliding mode controllers (SMC) to avoid the disconnection of WTS from the grid during faults are investigated. The first strategy consists of keeping the stator flux in a required level to ensure the DFIG's magnetization, and the insertion of the crowbar resistors in the rotor circuits to limit the rotor and stator currents and the DC bus voltage during voltage dip. The second strategy permits to create an artificial inertial response during frequency drop by means of the kinetic energy stored in the WTS' rotating masses. The aim of this strategy is to contribute in the network frequency stabilization and, therefore, the need for additional power afforded by conventional generators.