Hind Elaimani
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hind Elaimani has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Noureddine Elmouhi
Institut Supérieur d’Ingénierie et des Affaires (ISGA Rabat)
9 shared publications - Ahmed Essadki
Mohammed V University-Rabat-Morocco,ERERA, Research Center in Sciences and Technologies of Engineering and Health (STIS). Higher Normal School of Technical Education (ENSET)
8 shared publications Rachid Chakib
Laboratory of Innovation in Management and Engineering for Enterprise (LIMIE), ISGA Rabat Institut supérieur d’ingénierie et des affaires
6 shared publicationsAhmed Essadki
Mohammed V University in Rabat, Ecole Nationale Supérieure d’Arts et Métiers (ENSAM), Research Center of Engineering and Health Sciences and Technologies (STIS) Avenue de l'Armée Royale, Rabat, Morocco
2 shared publications- Fadoua Bahja
Institut Supérieur d’Ingénierie et des Affaires (ISGA Rabat)
1 shared publication - Ikram Aissaoui
Mohammed V University in Rabat
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (2)
Improved control strategy for harmonic current mitigation in DFIG-based wind turbines supplying linear and nonlinear loads
Improving power quality is a major challenge in grid-connected wind energy systems, especially under mixed linear and nonlinear load conditions. This paper proposes an enhanced control strategy for harmonic current mitigation in a doubly fed induction generator (DFIG)-based wind turbine. The proposed approach integrates flux-oriented vector control with an active harmonic compensation algorithm implemented through the rotor-side converter (RSC). Unlike conventional methods that target only specific harmonic orders, the proposed strategy mitigates all current harmonics at the point of common coupling (PCC). Simulation studies conducted under various load conditions demonstrate that the method significantly reduces the total harmonic distortion (THD) and ensures near-sinusoidal stator currents. The results confirm the effectiveness and robustness of the proposed control approach in improving the power quality of DFIG-based wind energy conversion systems.
- 1 June 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (2)
Open AccessImproved control strategy for harmonic current mitigation in DFIG-based wind turbines supplying linear and nonlinear loads
Improving power quality is a major challenge in grid-connected wind energy systems, especially under mixed linear and nonlinear load conditions. This paper proposes an enhanced control strategy for harmonic current mitigation in a doubly fed induction generator (DFIG)-based wind turbine. The proposed approach integrates flux-oriented vector control with an active harmonic compensation algorithm implemented through the rotor-side converter (RSC). Unlike conventional methods that target only specific harmonic orders, the proposed strategy mitigates all current harmonics at the point of common coupling (PCC). Simulation studies conducted under various load conditions demonstrate that the method significantly reduces the total harmonic distortion (THD) and ensures near-sinusoidal stator currents. The results confirm the effectiveness and robustness of the proposed control approach in improving the power quality of DFIG-based wind energy conversion systems.
- Open Access
- 1 September 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 14 (3) , 1382-1393
Fault tolerant control for DFIG wind turbine controlled by ADRC and optimized by genetic algorithm
This research work deals with the modelling, control and simulation of a wind turbine based on the doubly fed induction generator (DFIG) in the current sensor’s failure event. We present in the first time the model of the wind energy conversion system based on the DFIG and the control by active disturbances rejection control (ADRC) optimized by genetic algorithm. Particular focus is directed towards on a technique for detection, identification, isolation and reconfiguration of current sensor signals after failure. The combination of the two preceding techniques makes it possible to have a fault tolerant control to sensor faults which ensures continuity of service in all circumstances. The robustness of the proposed technique is tested under the MATLAB/Simulink environment.
- 1 September 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 14 (3) , 1382-1393
Open AccessFault tolerant control for DFIG wind turbine controlled by ADRC and optimized by genetic algorithm
This research work deals with the modelling, control and simulation of a wind turbine based on the doubly fed induction generator (DFIG) in the current sensor’s failure event. We present in the first time the model of the wind energy conversion system based on the DFIG and the control by active disturbances rejection control (ADRC) optimized by genetic algorithm. Particular focus is directed towards on a technique for detection, identification, isolation and reconfiguration of current sensor signals after failure. The combination of the two preceding techniques makes it possible to have a fault tolerant control to sensor faults which ensures continuity of service in all circumstances. The robustness of the proposed technique is tested under the MATLAB/Simulink environment.
- Open Access
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Robust control of wind turbine based on doubly-fed induction generator optimized by genetic algorithm
In this research paper we will cover the study of the modelling and the control methods of the variable speed wind turbine based on doubly-fed induction generator (DFIG). It represents the most stressed structure given its distinctive characteristics. To control the electrical powers generated by this system independently, the vector control with the stator flux orientation is founded according to two techniques: i) the control of the powers by the backstepping technique and ii) the robust control based on the active disturbances rejection control. After the synthesis of the controllers of those two methods, their performances will be tested and compared to evaluate their effectiveness. We are mainly interested in the robustness test of the two control strategies with respect to the internal parameters’ fluctuation of the generator. The computing of the different parameters regulators of these two strategies is carried out using a genetic algorithm. This computing method makes it possible to arrive at an optimal solution of the DFIG power control. The different parts are simulated using MATLAB/Simulink environment.
- 1 June 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 13 (2)
Open AccessRobust control of wind turbine based on doubly-fed induction generator optimized by genetic algorithm
In this research paper we will cover the study of the modelling and the control methods of the variable speed wind turbine based on doubly-fed induction generator (DFIG). It represents the most stressed structure given its distinctive characteristics. To control the electrical powers generated by this system independently, the vector control with the stator flux orientation is founded according to two techniques: i) the control of the powers by the backstepping technique and ii) the robust control based on the active disturbances rejection control. After the synthesis of the controllers of those two methods, their performances will be tested and compared to evaluate their effectiveness. We are mainly interested in the robustness test of the two control strategies with respect to the internal parameters’ fluctuation of the generator. The computing of the different parameters regulators of these two strategies is carried out using a genetic algorithm. This computing method makes it possible to arrive at an optimal solution of the DFIG power control. The different parts are simulated using MATLAB/Simulink environment.
- 3 February 2022
- Published by Faculty of Electrical Engineering, Computer Science and Information Technology Osijek in International journal of electrical and computer engineering systems
- Vol. 13 (1) , 77-86
Comparative study of power smoothing techniques produced by a wind energy conversion system
This paper aims to present and compare two techniques used to smooth the injected power in the grid from a doubly-fed induction generator (DFIG) based conversion system. The first technique based on an inertial storage system while the second is founded on limiting the power captured by the wind turbine. The overall system composed of a wind energy conversion system (WECS) allowing to convert a wind power into electric power. It is controlled by two converters, grid side converter and a rotor side converter, both are controlled by sliding mode. The storage system is used to consume power which exceeds the setpoint due to storing it or producing more in the event of a lack, the system is controlled through the flywheel side converter by the sliding mode. Numerical simulations were carried out using Matlab/Simulink software.
- 3 February 2022
- Published by Faculty of Electrical Engineering, Computer Science and Information Technology Osijek in International journal of electrical and computer engineering systems
- Vol. 13 (1) , 77-86
Comparative study of power smoothing techniques produced by a wind energy conversion system
This paper aims to present and compare two techniques used to smooth the injected power in the grid from a doubly-fed induction generator (DFIG) based conversion system. The first technique based on an inertial storage system while the second is founded on limiting the power captured by the wind turbine. The overall system composed of a wind energy conversion system (WECS) allowing to convert a wind power into electric power. It is controlled by two converters, grid side converter and a rotor side converter, both are controlled by sliding mode. The storage system is used to consume power which exceeds the setpoint due to storing it or producing more in the event of a lack, the system is controlled through the flywheel side converter by the sliding mode. Numerical simulations were carried out using Matlab/Simulink software.
- Open Access
- 1 January 2022
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 29 (1) , 120-132
Adaptive doubly fed induction generator’s control driven wind turbine using luenberger observer optimized by genetic algorithm
The calculation of control parameters for a system control method is based on the model of the system with assumed fixed internal parameters. However, these parameters can vary greatly due to several phenomena. This paper presents an adapted control of a doubly fed induction generator machine robust against the rotor resistance variations of the machine used as a generator in wind energy conversion systems. The adaptation is ensured by a system allowing to identify in real time the value of the resistance, the system used is mainly based on a Luenberger observer. The conversion system is divided into two parts, the first mechanical part containing the turbine and the gearbox, the second electrical one consisting of a double fed induction generator, linked on the stator side directly to the grid, and on the rotor, side linked to the grid through two power electronics converters interposed with a direct current (DC) link. The machine-side converter is used to control the active and reactive powers, and the second on the grid side is used to control the DC link voltage. The converters are controlled by the sliding mode strategy, and the validity of the methods is checked by simulation using MATLAB/Simulink.
- 1 January 2022
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 29 (1) , 120-132
Open AccessAdaptive doubly fed induction generator’s control driven wind turbine using luenberger observer optimized by genetic algorithm
The calculation of control parameters for a system control method is based on the model of the system with assumed fixed internal parameters. However, these parameters can vary greatly due to several phenomena. This paper presents an adapted control of a doubly fed induction generator machine robust against the rotor resistance variations of the machine used as a generator in wind energy conversion systems. The adaptation is ensured by a system allowing to identify in real time the value of the resistance, the system used is mainly based on a Luenberger observer. The conversion system is divided into two parts, the first mechanical part containing the turbine and the gearbox, the second electrical one consisting of a double fed induction generator, linked on the stator side directly to the grid, and on the rotor, side linked to the grid through two power electronics converters interposed with a direct current (DC) link. The machine-side converter is used to control the active and reactive powers, and the second on the grid side is used to control the DC link voltage. The converters are controlled by the sliding mode strategy, and the validity of the methods is checked by simulation using MATLAB/Simulink.
- Open Access
- 1 February 2020
- Published by Wiley in Journal of Energy
- Vol. 2020, 1-11
Comparative Study of the Grid Side Converter’s Control during a Voltage Dip
The modeling and control of a wind energy conversion system based on the Doubly Fed Induction Generator DFIG is the discussed theme in this paper. The purpose of this system was to control active and reactive power converted; this control is ensured thanks to the control of the two converters. The proposed control strategies are controlled by PI regulators and the sliding mode technique. In the present work a comparison of the robustness of the 2 controls of the grid side converter (GSC) during a voltage dip is shown. The simulation is carried out using the Matlab/Simulink software with a 300 kW generator.
- 1 February 2020
- Published by Wiley in Journal of Energy
- Vol. 2020, 1-11
Open AccessComparative Study of the Grid Side Converter’s Control during a Voltage Dip
The modeling and control of a wind energy conversion system based on the Doubly Fed Induction Generator DFIG is the discussed theme in this paper. The purpose of this system was to control active and reactive power converted; this control is ensured thanks to the control of the two converters. The proposed control strategies are controlled by PI regulators and the sliding mode technique. In the present work a comparison of the robustness of the 2 controls of the grid side converter (GSC) during a voltage dip is shown. The simulation is carried out using the Matlab/Simulink software with a 300 kW generator.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Evaluation of the Inertial Response of Variable Speed Wind Turbines Based on DFIG using Backstepping for a Frequency Control
In this paper, we are interested in the study of a DFIG based WECS controlled by the Backstepping as well as its participation in the grid frequency adjustment. The variable speed wind turbine based on DFIG can't participate in frequency setting when a fault occurs due to the decoupling between the rotation speed and the grid frequency. This decoupling is due to the grid side converter and the rotor side converter., we propose In this paper to study the participation of this type of turbine in the frequency adjustment using the synthetic inertial strategy based on the kinetic energy of the rotating masses of the conversion system. We will begin by studying the impact of a frequency drop on the DFIG characteristics controlled by the Backstepping. Then we will implement the synthetic inertia controller allowing the DFIG to act in frequency default. Finally, we will end with the simulation of the different parts using the Matlab / Simulink environment.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Evaluation of the Inertial Response of Variable Speed Wind Turbines Based on DFIG using Backstepping for a Frequency Control
In this paper, we are interested in the study of a DFIG based WECS controlled by the Backstepping as well as its participation in the grid frequency adjustment. The variable speed wind turbine based on DFIG can't participate in frequency setting when a fault occurs due to the decoupling between the rotation speed and the grid frequency. This decoupling is due to the grid side converter and the rotor side converter., we propose In this paper to study the participation of this type of turbine in the frequency adjustment using the synthetic inertial strategy based on the kinetic energy of the rotating masses of the conversion system. We will begin by studying the impact of a frequency drop on the DFIG characteristics controlled by the Backstepping. Then we will implement the synthetic inertia controller allowing the DFIG to act in frequency default. Finally, we will end with the simulation of the different parts using the Matlab / Simulink environment.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Modified Sliding Mode Control of a Doubly Fed Induction Generator for Wind Energy Conversion During a Voltage Dip
In this paper we present nonlinear control of the DFIG used in a wind energy conversion system (WECS). The DFIG is directly connected to the grid, moreover the the rotor is connected to the back-to-back converters. the DFIG's active and reactive powers are regulated by controlling the converters. In this work we used 2 methods based on sliding mode to control the rotor side converter. The first one is a normal sliding mode control using with reliable grid, the second one is a modified sliding mode used during the voltage dip. The machine is tested in association with a wind turbine. Simulations results are presented and discussed for the whole system.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Modified Sliding Mode Control of a Doubly Fed Induction Generator for Wind Energy Conversion During a Voltage Dip
In this paper we present nonlinear control of the DFIG used in a wind energy conversion system (WECS). The DFIG is directly connected to the grid, moreover the the rotor is connected to the back-to-back converters. the DFIG's active and reactive powers are regulated by controlling the converters. In this work we used 2 methods based on sliding mode to control the rotor side converter. The first one is a normal sliding mode control using with reliable grid, the second one is a modified sliding mode used during the voltage dip. The machine is tested in association with a wind turbine. Simulations results are presented and discussed for the whole system.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Robustness Test of the Double Fed Induction Generator Control Used in a Wind Energy Conversion System in the Voltage Dips Event
In this paper, we discuss the modeling and control of a wind energy conversion system based on a DFIG. The proposed control strategies are indirect control by PI regulators and the Backstepping technique. First, we test the performances of these two techniques to control the active and reactive powers, then we verify by simulation the performances in terms of the power setpoint monitoring, stability and robustness in the voltage dips event and the machine variation parameters.The simulation is carried out using the Matlab/ Simulink software with a 660kW generator.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Robustness Test of the Double Fed Induction Generator Control Used in a Wind Energy Conversion System in the Voltage Dips Event
In this paper, we discuss the modeling and control of a wind energy conversion system based on a DFIG. The proposed control strategies are indirect control by PI regulators and the Backstepping technique. First, we test the performances of these two techniques to control the active and reactive powers, then we verify by simulation the performances in terms of the power setpoint monitoring, stability and robustness in the voltage dips event and the machine variation parameters.The simulation is carried out using the Matlab/ Simulink software with a 660kW generator.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Active and Reactive Powers’ Control of the DFIG During Variations of its Parameters
The purpose of this paper is to present the "sliding mode" technique during the variations of the parameters of the double fed inductor generator “DFIG”, this method which is used to regulate the active and reactive powers has come to replace the conventional methods using PI regulators (Proportional Integral). The validity of the proposed methods is confirmed by the simulation results.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Active and Reactive Powers’ Control of the DFIG During Variations of its Parameters
The purpose of this paper is to present the "sliding mode" technique during the variations of the parameters of the double fed inductor generator “DFIG”, this method which is used to regulate the active and reactive powers has come to replace the conventional methods using PI regulators (Proportional Integral). The validity of the proposed methods is confirmed by the simulation results.