Sander Baas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sander Baas has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Aldrik H. Velders
Wageningen University & Research
4 shared publications - Maria Victoria Gomez
Facultad de Ciencias y Tecnologías Químicas, Instituto Regional de Investigación Científica Aplicada (IRICA), Universidad de Castilla-La Mancha, Avda Camilo José Cela s/n, 13071 Ciudad Real, Spain
2 shared publications - Daniel Krüger
Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
1 shared publication - Frederik Dreyer
Institute of Smart Sensors, University of Stuttgart, Stuttgart, Germany
1 shared publication - Jens Anders
University of Stuttgart
1 shared publication - Vittorio Saggiomo
BioNanoTechnology, Wageningen University and Research, Bornse Weilanden 9, 6708 WG Wageningen, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 15 September 2023
- Published by Springer Nature in Research Square
Shim-free homebuilt 2 T magnet for NMR spectroscopy with sub-ppm resolution and sub-nanomole sensitivity
Nuclear Magnetic Resonance (NMR) spectroscopy is quintessential for molecular characterization and quantification in many research areas. However, a major drawback is the complex and expensive instrumentation, which inhibits a greater use and impact. The required magnet is typically several Tesla strong to allow good sensitivity and adapted with complex shimming systems for sufficient field homogeneity in the standard 0.5 mL sample tubes. Here we show that a home-constructed 2.1 T permanent magnet suffices for NMR spectroscopy with chemical shift resolution and sensitivity that can be tailored to the requirements using home-built microcoils. 1D and 2D, 1H and 19F-NMR spectra are obtained without any shimming of the magnet, with resolution down to 0.3 ppm exploiting a 40 nL microcoil and sub-nanomole detection sensitivity is achieved by light-induced hyperpolarization. The presented paradigm of matching transceiver microcoils to the sweet-spot of home-built magnets allows for a more wide-spread use and democratization of NMR spectroscopy.
- 15 September 2023
- Published by Springer Nature in Research Square
Open AccessShim-free homebuilt 2 T magnet for NMR spectroscopy with sub-ppm resolution and sub-nanomole sensitivity
Nuclear Magnetic Resonance (NMR) spectroscopy is quintessential for molecular characterization and quantification in many research areas. However, a major drawback is the complex and expensive instrumentation, which inhibits a greater use and impact. The required magnet is typically several Tesla strong to allow good sensitivity and adapted with complex shimming systems for sufficient field homogeneity in the standard 0.5 mL sample tubes. Here we show that a home-constructed 2.1 T permanent magnet suffices for NMR spectroscopy with chemical shift resolution and sensitivity that can be tailored to the requirements using home-built microcoils. 1D and 2D, 1H and 19F-NMR spectra are obtained without any shimming of the magnet, with resolution down to 0.3 ppm exploiting a 40 nL microcoil and sub-nanomole detection sensitivity is achieved by light-induced hyperpolarization. The presented paradigm of matching transceiver microcoils to the sweet-spot of home-built magnets allows for a more wide-spread use and democratization of NMR spectroscopy.
- Open Access
- 30 June 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-14
Multinuclear 1D and 2D NMR with 19F-Photo-CIDNP hyperpolarization in a microfluidic chip with untuned microcoil
Nuclear Magnetic Resonance (NMR) spectroscopy is a most powerful molecular characterization and quantification technique, yet two major persistent factors limit its more wide-spread applications: poor sensitivity, and intricate complex and expensive hardware required for sophisticated experiments. Here we show NMR with a single planar-spiral microcoil in an untuned circuit with hyperpolarization option and capability to execute complex experiments addressing simultaneously up to three different nuclides. A microfluidic NMR-chip in which the 25 nL detection volume can be efficiently illuminated with laser-diode light enhances the sensitivity by orders of magnitude via photochemically induced dynamic nuclear polarization (photo-CIDNP), allowing rapid detection of samples in the lower picomole range (normalized limit of detection at 600 MHz, nLODf,600, of 0.01 nmol Hz1/2). The chip is equipped with a single planar microcoil operating in an untuned circuit that allows different Larmor frequencies to be addressed simultaneously, permitting advanced hetero-, di- and trinuclear, 1D and 2D NMR experiments. Here we show NMR chips with photo-CIDNP and broadband capabilities addressing two of the major limiting factors of NMR, by enhancing sensitivity as well as reducing cost and hardware complexity; the performance is compared to state-of-the-art instruments.
- 30 June 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-14
Open AccessMultinuclear 1D and 2D NMR with 19F-Photo-CIDNP hyperpolarization in a microfluidic chip with untuned microcoil
Nuclear Magnetic Resonance (NMR) spectroscopy is a most powerful molecular characterization and quantification technique, yet two major persistent factors limit its more wide-spread applications: poor sensitivity, and intricate complex and expensive hardware required for sophisticated experiments. Here we show NMR with a single planar-spiral microcoil in an untuned circuit with hyperpolarization option and capability to execute complex experiments addressing simultaneously up to three different nuclides. A microfluidic NMR-chip in which the 25 nL detection volume can be efficiently illuminated with laser-diode light enhances the sensitivity by orders of magnitude via photochemically induced dynamic nuclear polarization (photo-CIDNP), allowing rapid detection of samples in the lower picomole range (normalized limit of detection at 600 MHz, nLODf,600, of 0.01 nmol Hz1/2). The chip is equipped with a single planar microcoil operating in an untuned circuit that allows different Larmor frequencies to be addressed simultaneously, permitting advanced hetero-, di- and trinuclear, 1D and 2D NMR experiments. Here we show NMR chips with photo-CIDNP and broadband capabilities addressing two of the major limiting factors of NMR, by enhancing sensitivity as well as reducing cost and hardware complexity; the performance is compared to state-of-the-art instruments.
- 2 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 70 (9) , 3484-3496
A 5–780-MHz Transceiver ASIC for Multinuclear NMR Spectroscopy in 0.13-μm BiCMOS
In this paper, we present a broadband (5-780 MHz) transceiver ASIC optimized for $^{\bm{1}}$ H and X-nuclei nuclear magnetic resonance (NMR) with external custom-designed microcoils. The NMR-on-a-chip transceiver is realized in a 0.13 $\mu$ m BiCMOS technology, consumes an area of 1100 $\bm{\times}$ 900 $\mu$ m $\bm{^2}$ , and integrates a quadrature receiver, consisting of a low-noise amplifier, a quadrature downconversion mixer, and intermediate-frequency variable gain amplifiers, a power amplifier, and a frequency synthesizer on a single chip. An extensive noise analysis of the BJT-based low-noise amplifier with regard to the optimum source impedance provides simplified expressions for an optimized LNA design for broadband NMR-on-a-chip applications. The NMR-on-chip transceiver provides a measured state-of-the-art input-referred voltage noise of 610 pV/ $\sqrt{\text{Hz}}$ and a maximum RX gain of 66 dB. In combination with an external, custom-designed solenoidal microcoil, the presented NMR-on-a-chip transceiver achieves a state-of-the-art normalized $^{\bm{1}}$ H spin sensitivity of 7.2 $\bm{\times}$ 10 $^{\bm{17}}$ spins $/\sqrt{\text{Hz}}\cdot\text{T}^{\bm{2}}/$ m with an untuned, i.e. broadband front-end. Proof of concept NMR experiments on multiple nuclei ( $^{\bm{1}}$ H, $^{\bm{2}}$ H, $^{\bm{13}}$ C, and $^{\bm{19}}$ F) verify the applicability of the proposed untuned, broadband approach.
- 2 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 70 (9) , 3484-3496
A 5–780-MHz Transceiver ASIC for Multinuclear NMR Spectroscopy in 0.13-μm BiCMOS
In this paper, we present a broadband (5-780 MHz) transceiver ASIC optimized for $^{\bm{1}}$ H and X-nuclei nuclear magnetic resonance (NMR) with external custom-designed microcoils. The NMR-on-a-chip transceiver is realized in a 0.13 $\mu$ m BiCMOS technology, consumes an area of 1100 $\bm{\times}$ 900 $\mu$ m $\bm{^2}$ , and integrates a quadrature receiver, consisting of a low-noise amplifier, a quadrature downconversion mixer, and intermediate-frequency variable gain amplifiers, a power amplifier, and a frequency synthesizer on a single chip. An extensive noise analysis of the BJT-based low-noise amplifier with regard to the optimum source impedance provides simplified expressions for an optimized LNA design for broadband NMR-on-a-chip applications. The NMR-on-chip transceiver provides a measured state-of-the-art input-referred voltage noise of 610 pV/ $\sqrt{\text{Hz}}$ and a maximum RX gain of 66 dB. In combination with an external, custom-designed solenoidal microcoil, the presented NMR-on-a-chip transceiver achieves a state-of-the-art normalized $^{\bm{1}}$ H spin sensitivity of 7.2 $\bm{\times}$ 10 $^{\bm{17}}$ spins $/\sqrt{\text{Hz}}\cdot\text{T}^{\bm{2}}/$ m with an untuned, i.e. broadband front-end. Proof of concept NMR experiments on multiple nuclei ( $^{\bm{1}}$ H, $^{\bm{2}}$ H, $^{\bm{13}}$ C, and $^{\bm{19}}$ F) verify the applicability of the proposed untuned, broadband approach.
- Open Access
- 17 October 2022
- Published by Springer Nature in Research Square
Multinuclear 1D & 2D NMR with 19F-Photo-CIDNP hyperpolarization in a microfluidic chip with broadband microcoil
Nuclear Magnetic Resonance (NMR) spectroscopy is one of the most powerful molecular characterization and quantification techniques available today, yet two major persistent factors limit more wide-spread applications of NMR: the poor sensitivity, and the intricate complex and expensive hardware required for sophisticated NMR experiments. We present a microfluidic NMR-chip in which the 25 nL detection volume can be efficiently illuminated with laser-diode light that enhances the sensitivity by orders of magnitude via the photo-CIDNP hyperpolarization principle, allowing rapid detection of samples in the lower picomole range. The chip is further equipped with a single planar microcoil operating in broadband mode that allows different Larmor frequencies to be addressed simultaneously, permitting advanced hetero-, di- and trinuclear, 1D and 2D NMR experiments. The NMR chips with photo CIDNP and broadband capabilities address two of the major limiting factors of NMR, by enhancing sensitivity as well as reducing cost and hardware complexity, and the performance is compared to state-of-the-art instruments.
- 17 October 2022
- Published by Springer Nature in Research Square
Open AccessMultinuclear 1D & 2D NMR with 19F-Photo-CIDNP hyperpolarization in a microfluidic chip with broadband microcoil
Nuclear Magnetic Resonance (NMR) spectroscopy is one of the most powerful molecular characterization and quantification techniques available today, yet two major persistent factors limit more wide-spread applications of NMR: the poor sensitivity, and the intricate complex and expensive hardware required for sophisticated NMR experiments. We present a microfluidic NMR-chip in which the 25 nL detection volume can be efficiently illuminated with laser-diode light that enhances the sensitivity by orders of magnitude via the photo-CIDNP hyperpolarization principle, allowing rapid detection of samples in the lower picomole range. The chip is further equipped with a single planar microcoil operating in broadband mode that allows different Larmor frequencies to be addressed simultaneously, permitting advanced hetero-, di- and trinuclear, 1D and 2D NMR experiments. The NMR chips with photo CIDNP and broadband capabilities address two of the major limiting factors of NMR, by enhancing sensitivity as well as reducing cost and hardware complexity, and the performance is compared to state-of-the-art instruments.
- Open Access
- 8 June 2021
- Published by American Chemical Society (ACS) in ChemRxiv
Ender3 3D Printer Kit Transformed into Open, Programmable Syringe Pump Set
Ender 3 syringe pumps is an open source and open hardware device for converting an Ender 3 kit to a set of 3 syringe pumps. Almost everything needed for the build is the Ender 3 kit, even all the screws and the tools needed for the assembly. The only parts which needed to be bought are three 5x5 shaft couplers and M5 lead screw.
- 8 June 2021
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessEnder3 3D Printer Kit Transformed into Open, Programmable Syringe Pump Set
Ender 3 syringe pumps is an open source and open hardware device for converting an Ender 3 kit to a set of 3 syringe pumps. Almost everything needed for the build is the Ender 3 kit, even all the screws and the tools needed for the assembly. The only parts which needed to be bought are three 5x5 shaft couplers and M5 lead screw.