Frederik Dreyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Frederik Dreyer has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Jens Anders
University of Stuttgart
5 shared publications - Daniel Krüger
Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
3 shared publications - Qing Yang
Institute of Smart Sensors, University of Stuttgart, Stuttgart, Germany
3 shared publications - Bernhard Blümich
Institut für Technische und Makromolekulare Chemie, RWTH Aachen University, Aachen, Germany
2 shared publications - Jianyu Zhao
Institute of Smart Sensors, University of Stuttgart, Stuttgart, Germany
2 shared publications - Aldrik H. Velders
Wageningen University & Research
1 shared publication
Latest Publications
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (2) , 257-269
A Portable Chip-Based Overhauser DNP Platform for Biomedical Liquid Sample Analysis
Low-field nuclear magnetic resonance (NMR) instruments are an indispensable tool in industrial research and quality control. However, the intrinsically low spin polarization at low magnetic fields severely limits their detection sensitivity and measurement throughput, preventing their widespread use in biomedical analysis. Overhauser dynamic nuclear polarization (ODNP) effectively addresses this problem by transferring the spin polarization from free electrons to protons, significantly enhancing sensitivity. In this paper, we explore the potential of using ODNP for signal enhancement in a custom-designed portable chipbased DNP-enhanced NMR platform, which is centered around a miniaturized microwave (MW) transmitter, a custom-designed NMR-on-a-chip transceiver, and two application-specific ODNP probes. The MW transmitter provides frequency synthesis, signal modulation, and power amplification, providing sufficient output power for efficient polarization transfer. The NMR-on-a-chip transceiver combines a radio frequency (RF) transmitter with a fully differential quadrature receiver, providing pulsed excitation and NMR signal down-conversion and amplification. Two customdesigned ODNP probes are used for proof-of-concept DNPenhanced NMR relaxometry and spectroscopy measurements. The presented chip-based ODNP platform achieves a maximum MW output power of 34dBm, resulting in a signal enhancement of –162 using the relaxometry ODNP probe with 1.4 μL of 10mM non-degassed TEMPOL solution, and an enhancement of –63 with the spectroscopy ODNP probe using 50 nL of the same solution. The proton polarization was increased from 0.5×10 –6 to 81×10 –6 at a low field of 0.16T. Proof-of-concept measurements on radical-doped tattoo inks and acetic acid verify the potential of our chip-based ODNP platform for the analysis of biologically and medically relevant parameters such as relaxation times, chemical shifts, and hyperfine interactions.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (2) , 257-269
A Portable Chip-Based Overhauser DNP Platform for Biomedical Liquid Sample Analysis
Low-field nuclear magnetic resonance (NMR) instruments are an indispensable tool in industrial research and quality control. However, the intrinsically low spin polarization at low magnetic fields severely limits their detection sensitivity and measurement throughput, preventing their widespread use in biomedical analysis. Overhauser dynamic nuclear polarization (ODNP) effectively addresses this problem by transferring the spin polarization from free electrons to protons, significantly enhancing sensitivity. In this paper, we explore the potential of using ODNP for signal enhancement in a custom-designed portable chipbased DNP-enhanced NMR platform, which is centered around a miniaturized microwave (MW) transmitter, a custom-designed NMR-on-a-chip transceiver, and two application-specific ODNP probes. The MW transmitter provides frequency synthesis, signal modulation, and power amplification, providing sufficient output power for efficient polarization transfer. The NMR-on-a-chip transceiver combines a radio frequency (RF) transmitter with a fully differential quadrature receiver, providing pulsed excitation and NMR signal down-conversion and amplification. Two customdesigned ODNP probes are used for proof-of-concept DNPenhanced NMR relaxometry and spectroscopy measurements. The presented chip-based ODNP platform achieves a maximum MW output power of 34dBm, resulting in a signal enhancement of –162 using the relaxometry ODNP probe with 1.4 μL of 10mM non-degassed TEMPOL solution, and an enhancement of –63 with the spectroscopy ODNP probe using 50 nL of the same solution. The proton polarization was increased from 0.5×10 –6 to 81×10 –6 at a low field of 0.16T. Proof-of-concept measurements on radical-doped tattoo inks and acetic acid verify the potential of our chip-based ODNP platform for the analysis of biologically and medically relevant parameters such as relaxation times, chemical shifts, and hyperfine interactions.
- Open Access
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 2510-2517
Monitoring Physiological Signals With NMR-on-a-Chip Sensors for Motion Correction in Abdominal MRI
The aim of this study was to evaluate the feasibility of an NMR-on-a-chip sensor as local field probe for contactless monitoring of respiratory and cardiac motion-induced field changes and to investigate their applicability for motion synchronization in MRI. Cardiac and respiratory motion-induced field changes were recorded at 7 positions around the torso of 6 volunteers. The data were analysed regarding cardiac and respiratory components and the most promising location for assessment of respiratory motion identified. Further, the sensor-derived signal was correlated with the vendor-provided respiratory belt. The cranial parasternal positions were identified as excellent candidates for mapping cardiac motion, whereas the anterior locations at height of the diaphragm appear most promising for mapping of the respiration. Realtime analysis of the recorded signals was successfully applied for respiratory synchronization of the MR system and showed very good correlation with the respiratory belt with less fluctuation and shorter transient phase during breath-holding. NMR-on-a-chip sensors are sensitive enough for monitoring physiological motion and can be applied for respiratory motion synchronization. Depending on the positioning of the sensor, cardiac as well as respiratory induced field changes can be contactless mapped and used for synchronization of the MRI.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 2510-2517
Open AccessMonitoring Physiological Signals With NMR-on-a-Chip Sensors for Motion Correction in Abdominal MRI
The aim of this study was to evaluate the feasibility of an NMR-on-a-chip sensor as local field probe for contactless monitoring of respiratory and cardiac motion-induced field changes and to investigate their applicability for motion synchronization in MRI. Cardiac and respiratory motion-induced field changes were recorded at 7 positions around the torso of 6 volunteers. The data were analysed regarding cardiac and respiratory components and the most promising location for assessment of respiratory motion identified. Further, the sensor-derived signal was correlated with the vendor-provided respiratory belt. The cranial parasternal positions were identified as excellent candidates for mapping cardiac motion, whereas the anterior locations at height of the diaphragm appear most promising for mapping of the respiration. Realtime analysis of the recorded signals was successfully applied for respiratory synchronization of the MR system and showed very good correlation with the respiratory belt with less fluctuation and shorter transient phase during breath-holding. NMR-on-a-chip sensors are sensitive enough for monitoring physiological motion and can be applied for respiratory motion synchronization. Depending on the positioning of the sensor, cardiac as well as respiratory induced field changes can be contactless mapped and used for synchronization of the MRI.
- 19 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (4) , 831-842
A Portable Chip-Based NMR Relaxometry System With Arbitrary Phase Control for Point-of-Care Blood Analysis
In this paper, we present a portable NMR relaxometry system optimized for the point-of-care analysis of body liquids such as blood. The presented system is centered on an NMR-on-a-chip transceiver ASIC, a reference frequency generator with arbitrary phase control, and a custom-designed miniaturized NMR magnet with a field strength of 0.29 T and a total weight of 330 g. The NMR-ASIC co-integrates a low-IF receiver, a power amplifier, and a PLL-based frequency synthesizer on a total chip area of 1100 $\bm {\times }$ 900 $\mu$ m $\bm {^{2}}$ . The arbitrary reference frequency generator enables the use of conventional CPMG and inversion sequences, as well as modified water-suppression sequences. Moreover, it is used to implement an automatic frequency lock to correct temperature-induced magnetic field drifts. Proof-of-concept measurements on NMR phantoms and human blood samples show an excellent concentration sensitivity of v $\bm {_\rm{c,min}}$ = 2.2 mM/ $\bm {\sqrt{\rm{Hz}}}$ . This very good performance renders the presented system an ideal candidate for the future NMR-based point-of-care detection of biomarkers such as the blood glucose concentration.
- 19 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (4) , 831-842
A Portable Chip-Based NMR Relaxometry System With Arbitrary Phase Control for Point-of-Care Blood Analysis
In this paper, we present a portable NMR relaxometry system optimized for the point-of-care analysis of body liquids such as blood. The presented system is centered on an NMR-on-a-chip transceiver ASIC, a reference frequency generator with arbitrary phase control, and a custom-designed miniaturized NMR magnet with a field strength of 0.29 T and a total weight of 330 g. The NMR-ASIC co-integrates a low-IF receiver, a power amplifier, and a PLL-based frequency synthesizer on a total chip area of 1100 $\bm {\times }$ 900 $\mu$ m $\bm {^{2}}$ . The arbitrary reference frequency generator enables the use of conventional CPMG and inversion sequences, as well as modified water-suppression sequences. Moreover, it is used to implement an automatic frequency lock to correct temperature-induced magnetic field drifts. Proof-of-concept measurements on NMR phantoms and human blood samples show an excellent concentration sensitivity of v $\bm {_\rm{c,min}}$ = 2.2 mM/ $\bm {\sqrt{\rm{Hz}}}$ . This very good performance renders the presented system an ideal candidate for the future NMR-based point-of-care detection of biomarkers such as the blood glucose concentration.
- 2 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 70 (9) , 3484-3496
A 5–780-MHz Transceiver ASIC for Multinuclear NMR Spectroscopy in 0.13-μm BiCMOS
In this paper, we present a broadband (5-780 MHz) transceiver ASIC optimized for $^{\bm{1}}$ H and X-nuclei nuclear magnetic resonance (NMR) with external custom-designed microcoils. The NMR-on-a-chip transceiver is realized in a 0.13 $\mu$ m BiCMOS technology, consumes an area of 1100 $\bm{\times}$ 900 $\mu$ m $\bm{^2}$ , and integrates a quadrature receiver, consisting of a low-noise amplifier, a quadrature downconversion mixer, and intermediate-frequency variable gain amplifiers, a power amplifier, and a frequency synthesizer on a single chip. An extensive noise analysis of the BJT-based low-noise amplifier with regard to the optimum source impedance provides simplified expressions for an optimized LNA design for broadband NMR-on-a-chip applications. The NMR-on-chip transceiver provides a measured state-of-the-art input-referred voltage noise of 610 pV/ $\sqrt{\text{Hz}}$ and a maximum RX gain of 66 dB. In combination with an external, custom-designed solenoidal microcoil, the presented NMR-on-a-chip transceiver achieves a state-of-the-art normalized $^{\bm{1}}$ H spin sensitivity of 7.2 $\bm{\times}$ 10 $^{\bm{17}}$ spins $/\sqrt{\text{Hz}}\cdot\text{T}^{\bm{2}}/$ m with an untuned, i.e. broadband front-end. Proof of concept NMR experiments on multiple nuclei ( $^{\bm{1}}$ H, $^{\bm{2}}$ H, $^{\bm{13}}$ C, and $^{\bm{19}}$ F) verify the applicability of the proposed untuned, broadband approach.
- 2 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 70 (9) , 3484-3496
A 5–780-MHz Transceiver ASIC for Multinuclear NMR Spectroscopy in 0.13-μm BiCMOS
In this paper, we present a broadband (5-780 MHz) transceiver ASIC optimized for $^{\bm{1}}$ H and X-nuclei nuclear magnetic resonance (NMR) with external custom-designed microcoils. The NMR-on-a-chip transceiver is realized in a 0.13 $\mu$ m BiCMOS technology, consumes an area of 1100 $\bm{\times}$ 900 $\mu$ m $\bm{^2}$ , and integrates a quadrature receiver, consisting of a low-noise amplifier, a quadrature downconversion mixer, and intermediate-frequency variable gain amplifiers, a power amplifier, and a frequency synthesizer on a single chip. An extensive noise analysis of the BJT-based low-noise amplifier with regard to the optimum source impedance provides simplified expressions for an optimized LNA design for broadband NMR-on-a-chip applications. The NMR-on-chip transceiver provides a measured state-of-the-art input-referred voltage noise of 610 pV/ $\sqrt{\text{Hz}}$ and a maximum RX gain of 66 dB. In combination with an external, custom-designed solenoidal microcoil, the presented NMR-on-a-chip transceiver achieves a state-of-the-art normalized $^{\bm{1}}$ H spin sensitivity of 7.2 $\bm{\times}$ 10 $^{\bm{17}}$ spins $/\sqrt{\text{Hz}}\cdot\text{T}^{\bm{2}}/$ m with an untuned, i.e. broadband front-end. Proof of concept NMR experiments on multiple nuclei ( $^{\bm{1}}$ H, $^{\bm{2}}$ H, $^{\bm{13}}$ C, and $^{\bm{19}}$ F) verify the applicability of the proposed untuned, broadband approach.
- 16 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
A Broadband NMR Magnetometer System With Field Searching and Automatic Tuning Function
In this paper, we present a CMOS-based broadband nuclear magnetic resonance (NMR) magnetometer system with magnetic field searching and automatic tuning capabilities. The NMR frontend consists of a custom-designed NMR transceiver ASIC and an external LC resonance circuit formed by an NMR coil and a digitally tunable capacitor (DTC). With a 1mm NMR coil, the system is designed to measure magnetic fields between 0.54 T and 2.54 T with nanotesla resolution. To this end, the system automatically sweeps its excitation frequency to acquire an NMR signal from a known sample inside the NMR coil. The measured frequency of the NMR signal, together with the known Larmor frequency of the sample, can then be used to determine the unknown magnetic field with very high precision. The presented system provides an optimum sensitivity over its entire frequency range by automatically tuning the LC resonant circuit to the current Larmor frequency using the DTC. With a 0.78 μL sample of vegetable oil, the presented NMR magnetometer achieves an excellent field resolution of 1.77 nT inside a 1.45 T benchtop MR magnet, corresponding to a relative resolution of 1.2 ppb, which is limited by the field stability of the magnet. With its intrinsic frequency noise of 15 mHz, measured using a synthetic input signal, the presented sensor can support magnetic field resolutions down to 242 pT within a 1.45 T base field.
- 16 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
A Broadband NMR Magnetometer System With Field Searching and Automatic Tuning Function
In this paper, we present a CMOS-based broadband nuclear magnetic resonance (NMR) magnetometer system with magnetic field searching and automatic tuning capabilities. The NMR frontend consists of a custom-designed NMR transceiver ASIC and an external LC resonance circuit formed by an NMR coil and a digitally tunable capacitor (DTC). With a 1mm NMR coil, the system is designed to measure magnetic fields between 0.54 T and 2.54 T with nanotesla resolution. To this end, the system automatically sweeps its excitation frequency to acquire an NMR signal from a known sample inside the NMR coil. The measured frequency of the NMR signal, together with the known Larmor frequency of the sample, can then be used to determine the unknown magnetic field with very high precision. The presented system provides an optimum sensitivity over its entire frequency range by automatically tuning the LC resonant circuit to the current Larmor frequency using the DTC. With a 0.78 μL sample of vegetable oil, the presented NMR magnetometer achieves an excellent field resolution of 1.77 nT inside a 1.45 T benchtop MR magnet, corresponding to a relative resolution of 1.2 ppb, which is limited by the field stability of the magnet. With its intrinsic frequency noise of 15 mHz, measured using a synthetic input signal, the presented sensor can support magnetic field resolutions down to 242 pT within a 1.45 T base field.