Jin Jegal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jin Jegal has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Chang Heon Choi
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
16 shared publications - Jung-In Kim
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
15 shared publications - Seonghee Kang
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
13 shared publications - Inbum Lee
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
10 shared publications - Yoonsuk Huh
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
9 shared publications - Bo-Wi Cheon
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
7 shared publications
Latest Publications
- 1 July 2026
- Published by Elsevier in Optical Materials
- Vol. 179
Optical properties of CsPbBr3 nanocrystals scintillator under accelerator-based irradiation
- 1 July 2026
- Published by Elsevier in Optical Materials
- Vol. 179
Optical properties of CsPbBr3 nanocrystals scintillator under accelerator-based irradiation
- Open Access
- 31 March 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (1) , 28-37
Prediction of Therapeutic and Imaging Doses in the Gonadal Shielding Block Using Monte Carlo Simulation
Sung Hyun Lee, Inbum Lee, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Jong Min Park, Chang Heon Choi, Jung-in Kim, Kyung Su Kim, Eui Kyu Chie, Seonghee Kang. Progress in Medical Physics 2026;37:28-37. https://doi.org/10.14316/pmp.2026.37.1.28
- 31 March 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (1) , 28-37
Open AccessPrediction of Therapeutic and Imaging Doses in the Gonadal Shielding Block Using Monte Carlo Simulation
Sung Hyun Lee, Inbum Lee, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Jong Min Park, Chang Heon Choi, Jung-in Kim, Kyung Su Kim, Eui Kyu Chie, Seonghee Kang. Progress in Medical Physics 2026;37:28-37. https://doi.org/10.14316/pmp.2026.37.1.28
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 100-107
Validation of Clinically Optimized Multi-Leaf Collimator Parameters Using Enhanced Leaf Modeling in the AcurosXB Algorithm
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Chang Heon Choi, Jung-in Kim, Seonghee Kang. Progress in Medical Physics 2025;36:100-7. https://doi.org/10.14316/pmp.2025.36.4.100
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 100-107
Open AccessValidation of Clinically Optimized Multi-Leaf Collimator Parameters Using Enhanced Leaf Modeling in the AcurosXB Algorithm
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Chang Heon Choi, Jung-in Kim, Seonghee Kang. Progress in Medical Physics 2025;36:100-7. https://doi.org/10.14316/pmp.2025.36.4.100
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 165-174
Performance Evaluation of the HyperSight Cone-Beam Computed Tomography System on the Halcyon Platform: Installation Acceptance and Quantitative Image Quality Assessment
Yoonsuk Huh, Euntaek Yoon, Jin Jegal, Inbum Lee, Bo-Wi Cheon, Jongmin Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Sung Hyun Lee, Hyeongmin Jin, Jaeman Son. Progress in Medical Physics 2025;36:165-74. https://doi.org/10.14316/pmp.2025.36.4.165
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 165-174
Open AccessPerformance Evaluation of the HyperSight Cone-Beam Computed Tomography System on the Halcyon Platform: Installation Acceptance and Quantitative Image Quality Assessment
Yoonsuk Huh, Euntaek Yoon, Jin Jegal, Inbum Lee, Bo-Wi Cheon, Jongmin Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Sung Hyun Lee, Hyeongmin Jin, Jaeman Son. Progress in Medical Physics 2025;36:165-74. https://doi.org/10.14316/pmp.2025.36.4.165
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 139-146
Clinical Validation of EPIbeam as a Patient-Specific Pre-Treatment Quality Assurance System
Euntaek Yoon, Inbum Lee, Yoonsuk Huh, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Sung Hyun Lee, Seonghee Kang, Chang Heon Choi, Jong Min Park, Jung-in Kim, Jaeman Son. Progress in Medical Physics 2025;36:139-46. https://doi.org/10.14316/pmp.2025.36.4.139
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 139-146
Open AccessClinical Validation of EPIbeam as a Patient-Specific Pre-Treatment Quality Assurance System
Euntaek Yoon, Inbum Lee, Yoonsuk Huh, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Sung Hyun Lee, Seonghee Kang, Chang Heon Choi, Jong Min Park, Jung-in Kim, Jaeman Son. Progress in Medical Physics 2025;36:139-46. https://doi.org/10.14316/pmp.2025.36.4.139
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 147-154
Head Leakage in Modern Clinical Linear Accelerators: A Multimachine Appraisal at Seoul National University Hospital
Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Jin Jegal, Yoonsuk Huh, Jong Min Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Jaeman Son, Hyeongmin Jin, Sung Hyun Lee. Progress in Medical Physics 2025;36:147-54. https://doi.org/10.14316/pmp.2025.36.4.147
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 147-154
Open AccessHead Leakage in Modern Clinical Linear Accelerators: A Multimachine Appraisal at Seoul National University Hospital
Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Jin Jegal, Yoonsuk Huh, Jong Min Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Jaeman Son, Hyeongmin Jin, Sung Hyun Lee. Progress in Medical Physics 2025;36:147-54. https://doi.org/10.14316/pmp.2025.36.4.147
- Open Access
- 30 December 2025
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 50 (4) , 249-256
Clinical Evaluation of a Flexible Radiochromic Film for Surface-Dose Measurement in Breast Cancer Radiation Therapy
Background: Accurate quantification of surface dose is critical in radiation therapy, particularly for patients with breast cancer, for whom the risk of cutaneous toxicity is substantial. In this study, we evaluated the clinical feasibility of a novel flexible radiochromic film specifically designed to improve adhesion and usability on curved anatomic surfaces.Materials and Methods: The study prospectively enrolled 20 patients with breast cancer undergoing volumetric modulated arc therapy. Surface dose was measured using flexible radiochromic film placed near the surgical scar and close to the isocenter. Calibration curves were established using a 6 MV photon beam with flattening filter free and without, and the film response was analyzed in both transmission and reflection scanning modes. The measured surface doses were then compared with those calculated by the treatment planning system (TPS).Results and Discussion: The flexible radiochromic film demonstrated excellent sensitivity in the 1.5–2.5 Gy dose range, with superior performance observed in the transmission scanning mode. The film adhered securely to skin without requiring additional fixation and was removed without causing discomfort to the patient. Notably, substantial discrepancies were found between the measured and TPS-calculated surface doses, underscoring the limitations of a TPS in accurately modeling skin dose.Conclusion: Flexible radiochromic film demonstrated dosimetric performance similar to that of conventional films while offering enhanced flexibility and ease of clinical use. Given the significant uncertainty in TPS-based surface-dose estimation, the film provides accurate and practical in vivo surface-dose assessment in breast cancer radiotherapy.
- 30 December 2025
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 50 (4) , 249-256
Open AccessClinical Evaluation of a Flexible Radiochromic Film for Surface-Dose Measurement in Breast Cancer Radiation Therapy
Background: Accurate quantification of surface dose is critical in radiation therapy, particularly for patients with breast cancer, for whom the risk of cutaneous toxicity is substantial. In this study, we evaluated the clinical feasibility of a novel flexible radiochromic film specifically designed to improve adhesion and usability on curved anatomic surfaces.Materials and Methods: The study prospectively enrolled 20 patients with breast cancer undergoing volumetric modulated arc therapy. Surface dose was measured using flexible radiochromic film placed near the surgical scar and close to the isocenter. Calibration curves were established using a 6 MV photon beam with flattening filter free and without, and the film response was analyzed in both transmission and reflection scanning modes. The measured surface doses were then compared with those calculated by the treatment planning system (TPS).Results and Discussion: The flexible radiochromic film demonstrated excellent sensitivity in the 1.5–2.5 Gy dose range, with superior performance observed in the transmission scanning mode. The film adhered securely to skin without requiring additional fixation and was removed without causing discomfort to the patient. Notably, substantial discrepancies were found between the measured and TPS-calculated surface doses, underscoring the limitations of a TPS in accurately modeling skin dose.Conclusion: Flexible radiochromic film demonstrated dosimetric performance similar to that of conventional films while offering enhanced flexibility and ease of clinical use. Given the significant uncertainty in TPS-based surface-dose estimation, the film provides accurate and practical in vivo surface-dose assessment in breast cancer radiotherapy.
- 16 December 2025
- Published by Elsevier in Physica Medica
- Vol. 141, 105707
Comparative study of inertial measurement unit and optical tracking systems for respiratory motion management in radiotherapy
- 16 December 2025
- Published by Elsevier in Physica Medica
- Vol. 141, 105707
Comparative study of inertial measurement unit and optical tracking systems for respiratory motion management in radiotherapy
- Open Access
- 30 September 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (3) , 61-69
Clinical Commissioning of a Ceiling-Mounted Spoiler for Total Body Irradiation
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Seonghee Kang, Jaeman Son, Sung Hyun Lee, Chang Heon Choi, Jung-in Kim, Hyeongmin Jin. Progress in Medical Physics 2025;36:61-39. https://doi.org/10.14316/pmp.2025.36.3.61
- 30 September 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (3) , 61-69
Open AccessClinical Commissioning of a Ceiling-Mounted Spoiler for Total Body Irradiation
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Seonghee Kang, Jaeman Son, Sung Hyun Lee, Chang Heon Choi, Jung-in Kim, Hyeongmin Jin. Progress in Medical Physics 2025;36:61-39. https://doi.org/10.14316/pmp.2025.36.3.61