ICIsabelle Helena Gurgel de Carvalho

Isabelle Helena Gurgel de Carvalho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Isabelle Helena Gurgel de Carvalho has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical performance of ultratranslucent monolithic zirconia posterior crowns compared with lithium disilicate crowns: A pilot, randomized, double‐blind, controlled clinical trial

    by Larissa Mendonça Miranda, Isabelle Helena Gurgel de Carvalho, Lidya Nara Marques de Araújo, Mutlu Özcan, Rodrigo Othávio de Assunção e Souza

    Purpose: To evaluate, through a pilot, randomized, double‐blind, controlled clinical trial, the clinical performance of ultratranslucent monolithic zirconia (UTZr) compared to lithium disilicate (LD) posterior crowns after 24 months of follow‐up. Materials and Methods: Twenty‐four crowns were fabricated and placed in 18 patients, assigned to 2 groups: Control (LD—IPS e.max CAD/Ivoclar) and Experimental (UTZr—Zircon FitPlus/Talmax). Longevity was assessed using the modified United States Public Health Service (USPHS) Ryge criteria, visual analog scales (VAS) for patients’ self‐perceived esthetics, and the Oral Impacts on Daily Performances (OIDP) index for quality‐of‐life evaluation. Evaluations were conducted at baseline (T0) and 1 (T1), 6 (T2), 12 (T3), and 24 (T4) months after cementation. Survival analysis was performed using the Kaplan‐Meier method with log‐rank test (α = .05). OIDP and USPHS data were analyzed descriptively, while VAS esthetic satisfaction was analyzed using Mann‐Whitney, Friedman, and Wilcoxon post‐hoc tests. Results: The mean age of participants was 38.5 years. Eleven crowns were fabricated with LD and 13 with UTZr. After 24 months, the cumulative survival rate was 100% for both groups. Both groups showed a significant improvement in esthetic satisfaction over time ( P <.05). No ceramic fractures, occlusal changes, marginal integrity alterations, or secondary caries were observed; however, one UTZr crown presented minor marginal discoloration. Conclusions: Both materials, ultratranslucent monolithic zirconia and lithium disilicate, demonstrated high survival rates and satisfactory clinical performance after 24 months.


  • Repair bond strength of resin composite to CAD/CAM glass-ceramic: Influence of cleaning methods, surface treatments, and aging

    by Mariana Silva de Bessa, Liliane Cristina Nogueira Marinho, Larissa Mendonça de Miranda, Isabelle Helena Gurgel de Carvalho, Bruna Oliveira Campos, Boniek Castillo Dutra Borges, Patrícia dos Santos Calderon, Rodrigo Othávio de Assunção e Souza


  • Open Access

    Internal and marginal discrepancies of monolithic zirconia, polymer infiltrated ceramic, and lithium disilicate crowns: an in vivo study

    by Larissa Mendonça de Miranda, Sophia Queiroz Marques dos Santos, Anne Heloyse Teixeira Crispim, Isabelle Helena Gurgel de Carvalho, Amanda Maria de Oliveira Dal Piva, Yu Zhang, Rodrigo Othávio de Assunção e Souza

    Evaluate the marginal and internal discrepancies of Lithium Disilicate (LD), Monolithic Zirconia (Zr), and Polymer-Infiltrated Ceramics (PIC) crowns in vivo. Thirty patients requiring posterior single crowns were divided into three groups (n = 10 each): LD (IPS e.max CAD), Zr (Zircon Fit Plus), and PIC (VITA Enamic). After tooth preparation and temporary crown placement, impressions were taken for the fabrication of the crown. Marginal (MD) and Internal (ID) Discrepancies were measured before cementation using the replica technique and optical stereomicroscopy. ID was assessed by measuring the light body silicone thickness in occlusal, cusp, axial, and chamfer regions, while MD was evaluated at the chamfer finish line. ID was analyzed by two-way ANOVA and Tukey tests, while MD was analyzed by one-way ANOVA (α=5%). For ID, ANOVA revealed that the factors “material”, “region”, and their interaction were significant (p < 0.05). Although ID values varied by material and region, all remained within clinically acceptable limits. When comparing the experimental groups, PICo (226.0±84.7A μm) and PICc (165.6±71.9AB μm) exhibited the highest ID values, while LDax (87.9±17.3D μm) and PICax (91.4±36.2D μm) had the lowest. For MD, ANOVA revealed no significant differences between the materials (p = 0.4287): Zr (108.4 ± 34.6 μm), LD (95.7 ± 13.6 μm), and PIC (114.5 ± 42 μm). ID and MD were comparable among the evaluated crown materials, with all values falling within clinically acceptable limits. However, the lack of reported acceptable clinical thresholds and limited sample size highlight the need for larger-scale studies and long-term follow-ups to assess the longevity of restorative treatments.


  • Effect of full-step versus simplified resin cement luting strategies on the push-out bond strength of indirect resin composite restorations bonded to dentin

    by Bianca Cristina Dantas da Silva, Isabelle Helena Gurgel de Carvalho, Taciana Emília Leite Vila-Nova, Gabriela Monteiro de Araújo, Boniek Castillo Dutra Borges, Marília Regalado Galvão Rabelo Caldas, Isauremi Vieira de Assunção, Mutlu Özcan, Rodrigo Othávio de Assunção e Souza

    Indirect restorations made of resin composite materials are increasingly used yet there is no consensus in the literature on how different luting strategies influence the bond strength. The aim of this was to study the influence of luting strategy and aging on the adhesion of indirect restorations on dentin. Bovine incisors (N = 120) received conical cavities and filled them with resin composite. The cone sets were divided into 8 groups (n = 15 each) and the cylinders were cemented according to: ‘Luting strategy’ (U200: Self-adhesive cement resin; ULT: Scotchbond Universal + RelyX Ultimate; SB2: Phosphoric Acid + Adper Single Bond 2 + RelyX ARC; SBMP: Phosphoric Acid + Scotchbond Multi-purpose + ARC) and ‘Aging’ (Tc: With thermocycling/10.000 cycles: 5–55 °C; Without thermocycling). The specimens were subjected to a Push-out Bond Strength (σ) (100 kgf; 0.5 mm/min). Stereomicroscope and scanning electron microscopy (SEM) images were made to classify the failures. Data (MPa) were submitted to two-way-ANOVA, Tukey (α = 5%), and Weibull tests. ANOVA revealed that ‘luting strategy’ and ‘aging’ were statistically significant. When the factor ‘TC’ was evaluated separately, the TC groups presented higher bond strength than the unaged groups. As for the non-thermocycling groups, the different luting strategies had no statistical difference, except for the SB2 group, which was lower than ULT. Among all groups, TC, U200_Tc, SBMP_Tc, and ULT_Tc were statistically similar and significantly higher than that of the SB2-Tc group. The Weibull modulus was statistically different among the groups but characteristic strength was significant. Mixed failures were predominantly observed. Self-conditioning strategy promoted higher bond strength than the two-step conventional strategy but after thermocycling, the two-step conventional strategy presented the worst performance among the experimental groups.


  • Bond strength, degree of conversion, and microorganism adhesion using different bracket-to-enamel bonding protocols

    by Lorena Marques Ferreira de Sena, Dayanne Monielle Duarte Moura, Isabelle Helena Gurgel de Carvalho, Leopoldina de Fatima Dantas de Almeida, Nathalia Ramos da Silva, Rodrigo Othávio de Assunção e Souza

    Purpose This study aimed to evaluate the effect of bonding protocols and the type of orthodontic resin on the adhesion of microorganisms, degree of conversion (DC), and shear bond strength (SBS) of metallic brackets to enamel. Methods A total of 60 bovine incisors were prepared and randomly divided into 6 groups (n = 10): “bonding protocol” (A: phosphoric acid; AXT: A+Transbond™ XT primer adhesive [all Transbond™ products from 3M Unitek, Monrovia, CA, USA]; and SE: Transbond™ Plus Self Etching Primer) and “orthodontic resin” (XT: Transbond™ XT adhesive paste and CC: Transbond™ Plus Color Change). After bonding, the samples were subjected to thermocycling (5000 cycles) and to the SBS test. Bond failures were classified according to the adhesive remnant index (ARI). Next, 60 enamel blocks were sterilized in ethylene oxide in order to perform the CFU (Streptococcus mutans) assay in vitro to analyze the colony forming units (CFU/mL). Then, 60 discs of each orthodontic resin were made to measure the DC. The SBS (MPa), CFU/mL, and DC (%) data were statistically analyzed by two-way analysis of variance and Tukey’s test (5%) was performed for the DC. Results CFU and SBS revealed no significance for all factors (P > 0.05). Tukey’s test showed that A_XT (acid+Transbond™ XT adhesive paste) presented the highest DC (70.38% ± 10.5), while AXT_XT (acid+Transbond™ XT primer adhesive+Transbond™ XT adhesive paste) showed the lowest (23.47% ± 10.4). An ARI score of 2 was more frequent for the CC resin and an ARI score of 4 for the XT resin. Conclusion The CC resin does not reduce adhesion of S. mutans around orthodontic brackets and the bonding protocol did not influence the SBS, although the SE and A_XT groups contributed to a better DC.


  • Does the zirconia cleaning protocol followed by vitrification increase the resin-bond strength to zirconia?

    by Rodrigo Furtado de Carvalho, César Dalmolin Bergoli, Renata Marques de Melo, Lilian Costa Anami, Marco Antonio Bottino, Mutlu Özcan, Isabelle Helena Gurgel De Carvalho, Rodrigo Othavio de Assunção e Souza

    Evaluate the influence of cleaning protocols on vitrification patterns, contact angles, and bond strength between zirconia and resin cement. 48 zirconia discs were sectioned, polished, and sintered (15 × 2 mm). The discs were randomized into four groups according to the zirconia cleaning protocol (n = 12), following: CJ (positive control)-sandblasted with 30-µm particles of alumina coated by silica (Cojet/3M); AV (negative control)-cleaning with alcohol + vitrification (glaze); PV-37% phosphoric acid + vitrification; and HFV-10% hydrofluoric acid + vitrification. Next, the surfaces were conditioned with hydrofluoric acid and then silanized. The samples from the CJ treatment group were silanized to proceed with the cementation stage. Resin cement cylinders were built on 10 specimens from each group (ϕ = 3mm, height = 5mm), following the manufacturer’s instructions, and next they were subjected to thermocycling (5000 cycles at 5 °C and 55 °C for 30 s) followed by the shear test (1 mm/min) and failure analysis. Two discs of each group were subjected to contact angle evaluation and surface analysis under SEM. One-way ANOVA (α = 0.05) and Tukey’s test (p < 0.05) were used to analyze the data (MPa). Weibull analysis was performed to evaluate the shear bond strength test data. Our results revealed that the shear bond strength varied among our experimental groups (p < 0.0001). AV = 9.5 (0.5)B presented lower bond strength than CJ = 10.8 (0.2)A, PV = 10.9 (0.2)A, and HFV = 10.9 (0.3)A experimental groups. The predominant mode of failure was the adhesive between the resin cement and glaze. Surface treatments have influenced the contact angles (p < 0.0001), following: CJ = 41.6 (0.9)C; AV = 52.1 (0.7)A; PV = 46.8 (0.5)B; and HFV = 46.0 (0.9)B. Zirconia cleaning protocols using 37% phosphoric acid or 10% HF followed by glaze application demonstrated to modify the ceramic surface and to increase the bond strength to resin cement after its etching with HF followed by silanization. Cleaning protocol using acid (e.g. H3PO4 or HF) followed by vitrification of zirconia surface appears to be an applicable alternative to modify the ceramic surface and to increase its resin-bond strength after etching with HF followed by silanization.


  • Effect of finishing/polishing techniques and aging on topography, C. albicans adherence, and flexural strength of ultra-translucent zirconia: an in situ study

    by Isabelle Helena Gurgel de Carvalho, Nathalia Ramos da Silva, Taciana Emília Leite Vila-Nova, Leopoldina de Fatima Dantas de Almeida, Aretha Heitor Veríssimo, Renata Marques de Melo, Yu Zhang, Rodrigo Othávio de Assunçãao e Souza

    Objective To investigate the influence of different finishing/polishing techniques and in situ aging on the flexural strength (σ), surface roughness, and Candida albicans adherence of 5 mol% yttria-stabilized zirconia (ultratranslucent zirconia). Materials and methods A total of 120 zirconia bars (Prettau Anterior, Zirkonzahn) with dimensions of 8 × 2 × 0.5 mm were divided into 8 groups (n = 15) according to two factors: “in situ aging” (non-aged and aged (A)) and “finishing/polishing” (control (C), diamond rubber polishing (R), coarse grit diamond bur abrasion (B), and coarse grit diamond bur abrasion + diamond rubber polishing (BR)). Half of the samples from each group were subjected to a 60-day in situ aging by fixing the bars into cavities prepared in the posterior region of the base of complete or partial dentures of 15 patients. The samples were then subjected to the mini flexural (σ) test (1 mm/min). A total of 40 zirconia blocks (5 × 5 × 2 mm) were prepared and subjected to roughness (Ra) analyses and fungal adherence and complementary analyses (X-ray diffraction (XRD) and scanning electron microscopy (SEM)). The data of mean σ (MPa) and roughness Ra (μm) were statistically analyzed by two-way and one-way ANOVA, respectively, and Tukey’s test. The Weibull analysis was performed for σ data. The fungal adhesion (Log CFU/mL) data were analyzed by Kruskal–Wallis tests. Results For flexural resistance, the “finishing/polishing” factor was statistically significant (P = 0.0001); however, the “in situ aging” factor (P = 0.4458) was not significant. The non-aged (507.3 ± 115.7 MPa) and aged (487.6 ± 118.4 MPa) rubber polishing groups exhibited higher mean σ than the other techniques. The non-aged (260.2 ± 43.3 MPa) and aged (270.1 ± 48.8 MPa) bur abrasion groups presented lower σ. The coarse-grit diamond bur abrasion group (1.82 ± 0.61 µm) presented the highest roughness value (P = 0.001). Cell adhesion was not different among groups (P = 0.053). Group B presented the most irregular surface and the highest roughness Ra of 0.61 m. Conclusions The finishing of ultratranslucent zirconia might be preferably done with a diamond rubber polisher. Moreover, the protocols used did not interfere with Candida albicans adhesion. Clinical relevance Coarse-grit diamond burs might be avoided for finishing ultratranslucent monolithic zirconia, which might be preferably performed with a diamond rubber polisher.


  • Can enamel etching with the Er:YAG laser be an alternative to the conventional phosphoric acid for bracket bonding? A systematic review and meta-analysis

    by Nathalia Ramos da Silva, Larissa Mendonça de Miranda, Isabelle Helena Gurgel de Carvalho, Lorena Marques Ferreira de Sena, Dayanne Monielle Duarte Moura, Mutlu Özcan, Rodrigo Othávio de Assunção e Souza

    This systematic review and meta-analysis aimed to evaluate the effect of Er:YAG laser etching on shear bond strength (SBS) of brackets bonded to the enamel and compare to the phosphoric acid (control). Electronic databases (PubMed, Scopus, and Web of Science) and a manual search were conducted up to January 2021. In vitro studies comparing Er:YAG laser and phosphoric acid etching for metal bracket bonding to human teeth, that performed aging of samples submitted to SBS tests were included. The risk of bias was assessed considering specific parameters. Statistical analysis was conducted using the RStudio statistical program for meta-analysis. Among 1456 potentially eligible studies, 19 were selected for full-text analysis, and 12 were included for qualitative and quantitative analysis. In the general meta-analysis, phosphoric acid etching showed higher SBS (n = 516; p = 0.02; I2 = 95.4%). The 100 mJ (p = 0.05; I2 = 76.2%) and p < 0.01; I2 = 89.5%) showed a significant difference, favoring phosphoric acid etching, however, there was no significant difference in the >100 mJ subgroup (p < 0.32; I2 = 93.3%). In the 500-thermocycle subgroup, phosphoric acid etching had a significantly higher SBS (p < 0.01; I2 = 96.2%), however, there was no significant difference in etching techniques for the 5000-cycle subgroup (p = 0.10; I2 = 69.1%). Although Er:YAG laser provides lower SBS than phosphoric acid etching, it provides an adequate bracket bonding. Further investigations to establish a laser protocol and clinical evidence are important for the consolidation of Er:YAG laser as a viable alternative to phosphoric acid.


  • Effect of finishing/polishing techniques and low temperature degradation on the surface topography, phase transformation and flexural strength of ultra-translucent ZrO2 ceramic

    by Taciana Emília Leite Vila-Nova, Isabelle Helena Gurgel de Carvalho, Dayanne Monielle Duarte Moura, André Ulisses Dantas Batista, Yu Zhang, Carlos Alberto Paskocimas, Marco Antonio Bottino, Rodrigo Othávio de Assunção e Souza