NSNathalia Ramos da Silva

Nathalia Ramos da Silva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nathalia Ramos da Silva has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A simplified digital workflow for reestablishing the vertical dimension of occlusion in a complete arch implant-supported prosthesis: A clinical report

    by Fernanda Gurgel de Gois Moreira, Nathalia Ramos da Silva, Larissa Mendonça de Miranda, Eduardo Miyashita, Rodrigo Othávio de Assunção e Souza

  • Influence of 3D printing system, postpolymerization and aging protocols on resin flexural strength and dimensional stability for printing occlusal splints, models and temporary restorations

    by Fernanda Gurgel de Gois Moreira, Nathalia Ramos da Silva, Marcella Guedes Pereira Gouvêa Bezerra, Sarah Emille Gomes da Silva, Sheila Butler, Karina Barbosa Souza, Rodrigo Othávio de Assunção e Souza

    Objectives Investigate the effect of different postpolymerization protocols, aging, and 3D printing systems on the flexural strength (σ), dimensional stability, and roughness of resins used to fabricate occlusal splints, dental models, and temporary restorations. Material and methods 180 bars (25 × 2 x 2 mm—ISO 4049) of each type of resin (T—Temporary/Cosmos Temp, Yller; OS—Occlusal splint/Cosmos Splint, Yller; MO – Models/ Cosmos Model, Yller) were printed and divided into 12 groups (n = 15) according to the factors: “Postpolymerization” (Ctr – Control; UV – Ultraviolet oven and MW – Microwave); “Printer” (SLA- stereolithography (Forms 2/Formslab); LCD- liquid crystal display (FlashForge Foto 6.0/FlashForge)) and “Aging” (TC – 10,000 thermocycling cycles and Without). Each bar was measured with a digital caliper at 11 points before and after postpolymerization to evaluate dimensional stability. The samples were subjected to the σ test (100Kgf;1 mm/min). Data was evaluated using Three- and Two-way ANOVA, and Tukey’s test (5%). Weibull analysis, Scanning Electron Microscopic and optical profilometry was performed. Results LCD printing system and UV oven postpolymerization exhibited the highest σ (P < .05). The groups printed in SLA and post-polymerized in microwave ovens showed the greatest variations in their dimensions, for the occlusal splint resin, the OS-SLA-MW group (-4.29 ± 3.15)A showed a shrinkage of 40.2%. The resins for models (3.31 ± 0.66)A and temporary (-2.06 ± 1.52)A showed a shrinkage of 33% and 20.6%, respectively. Conclusions LCD printing with UV light postpolymerization was the most effective method for resins used in occlusal splints, dental models, and temporary restorations. SLA printing with UV postpolymerization showed the most significant dimensional changes, leading to shrinkage in occlusal splint resins, while model resins and temporary restorations expanded. Clinical relevance Resins for 3D printing should ideally be post-polymerized with UV light and printed using LCD technology, as this approach results in better mechanical properties and less dimensional change compared to microwave oven post-polymerization.


  • Accuracy, adaptation and margin quality of monolithic zirconia crowns fabricated by 3D printing versus subtractive manufacturing technique: A systematic review and meta-analysis of in vitro studies

    by Sarah Emille Gomes da Silva, Nathalia Ramos da Silva, João Vitor Do Nascimento Santos, Fernanda Gurgel de Gois Moreira, Mutlu Özcan, Rodrigo Othávio de Assunção e Souza


  • Open Access

    Restabelecimento da dimensão vertical de oclusão com JIG estético modificado e prótese parcial removível overlay: relato de caso

    by Aretha Heitor Veríssimo, Anne Kaline Claudino Ribeiro, Nathália Ramos da Silva, Bárbara Beatriz Teixeira Lima Cardoso de Souza, Júlia Carvalheira Dourado, Rodrigo Othávio De Assunção e Souza, Adriana Da Fonte Porto Carreiro

    A reabilitação de pacientes parcialmente edêntulos com desgaste dentário severo e dimensão vertical de oclusão reduzida é desafiadora e complexa. Objetivo: Descrever o restabelecimento da dimensão vertical de oclusão e parâmetros estéticos com uma prótese parcial removível do tipo overlay (PPRO) com auxílio de um JIG estético modificado. Relato de caso: Paciente do sexo masculino, 58 anos de idade, procurou serviço odontológico queixando-se de insatisfação com a estética do sorriso e perda dos dentes posteriores. Ao exame clínico, foram observados desgaste dentário excessivo e edentulismo parcial nas arcadas superior e inferior. Então, foi proposto tratamento em 2 etapas (provisória e definitiva) com PPRO em maxila. O JIG estético foi usado como guia de referência para incrementos em resina composta fotopolimerizável e o restabelecimento da dimensão vertical de oclusão foi determinado a partir de métodos métrico, fonético e estético. Os dentes desgastados foram aumentados e os dentes ausentes substituídos por dentes artificiais a partir de uma PPRO provisória. Após 2 meses de adaptação, a reabilitação final com PPRO definitiva foi conduzida baseando-se na reabilitação com a PPRO provisória. Conclusão: O paciente relatou satisfação com a estética e desempenho funcional com o tratamento. Portanto, o JIG estético beneficia o planejamento e tratamento para restabelecer a dimensão vertical de oclusão. Além disso, a PPRO é uma alternativa reversível, de baixo custo para reabilitar a estética e função de pacientes com desgaste severo e perda parcial dos dentes.

  • Bond strength, degree of conversion, and microorganism adhesion using different bracket-to-enamel bonding protocols

    by Lorena Marques Ferreira de Sena, Dayanne Monielle Duarte Moura, Isabelle Helena Gurgel de Carvalho, Leopoldina de Fatima Dantas de Almeida, Nathalia Ramos da Silva, Rodrigo Othávio de Assunção e Souza

    Purpose This study aimed to evaluate the effect of bonding protocols and the type of orthodontic resin on the adhesion of microorganisms, degree of conversion (DC), and shear bond strength (SBS) of metallic brackets to enamel. Methods A total of 60 bovine incisors were prepared and randomly divided into 6 groups (n = 10): “bonding protocol” (A: phosphoric acid; AXT: A+Transbond™ XT primer adhesive [all Transbond™ products from 3M Unitek, Monrovia, CA, USA]; and SE: Transbond™ Plus Self Etching Primer) and “orthodontic resin” (XT: Transbond™ XT adhesive paste and CC: Transbond™ Plus Color Change). After bonding, the samples were subjected to thermocycling (5000 cycles) and to the SBS test. Bond failures were classified according to the adhesive remnant index (ARI). Next, 60 enamel blocks were sterilized in ethylene oxide in order to perform the CFU (Streptococcus mutans) assay in vitro to analyze the colony forming units (CFU/mL). Then, 60 discs of each orthodontic resin were made to measure the DC. The SBS (MPa), CFU/mL, and DC (%) data were statistically analyzed by two-way analysis of variance and Tukey’s test (5%) was performed for the DC. Results CFU and SBS revealed no significance for all factors (P > 0.05). Tukey’s test showed that A_XT (acid+Transbond™ XT adhesive paste) presented the highest DC (70.38% ± 10.5), while AXT_XT (acid+Transbond™ XT primer adhesive+Transbond™ XT adhesive paste) showed the lowest (23.47% ± 10.4). An ARI score of 2 was more frequent for the CC resin and an ARI score of 4 for the XT resin. Conclusion The CC resin does not reduce adhesion of S. mutans around orthodontic brackets and the bonding protocol did not influence the SBS, although the SE and A_XT groups contributed to a better DC.


  • Can the type of preheated resin composite influence the microtensile bond strength of ceramic restoration to human dentin?

    by Vinícius Anéas Rodrigues, Julio Nogueira Luz, Bianca Cristina Dantas da Silva, Nathalia Ramos da Silva, Marco Antonio Bottino, Renata Marques de Melo Marinho, Mutlu Özcan, Rodrigo Othávio de Assunção e Souza

    The aim of this study was to evaluate the effect of the type of preheated resin composite on the microtensile bond strength (µTBS) between dentin and feldspathic ceramic inlays. Thirty healthy human premolars received inlay preparations for feldspathic ceramic restorations and were then divided into three treatment groups according to the luting agent (n = 10): Conventional Resin Cement (RC), Preheated Nanofilled Methacrylate-Based Resin composite (MB), and Preheated Microhybrid Silorane-Based Resin composite (SB). The composite resin was preheated to 55 °C, considering the cementation group. After cementation, the sets were cut into slabs with a bonding area of 1 mm2 to be further submitted to the µTBS test (0.5 mm/min, and10 Kgf load cell). One-way ANOVA and Tukey test (p < .5) were performed to analyze the bond strength data (MPa). Failures were observed under a stereomicroscope and representative specimens were evaluated using a Scanning Electron Microscopy (SEM). ANOVA revealed that the type of luting agent utilized was significant (p = .001). Bond strength values for the RC (7.37 ± 1.27 MPa)A and MB (6.98 ± 1.96 MPa)A treatment groups were similar and greater than the SB (4.74 ± 1.65 MPa)B. Adhesive failures between the cementing agent and ceramic were prevalent for the treatment groups. The preheated nanofilled methacrylate resin-based composite technique can promote bond strength similar to resin cement, whereas preheated silorane-based resin composite as a luting agent should be seen with caution. Thus, we concluded that the type of luting agent has influenced the µTBS of feldspathic restoration to dentin.


  • Effect of finishing/polishing techniques and aging on topography, C. albicans adherence, and flexural strength of ultra-translucent zirconia: an in situ study

    by Isabelle Helena Gurgel de Carvalho, Nathalia Ramos da Silva, Taciana Emília Leite Vila-Nova, Leopoldina de Fatima Dantas de Almeida, Aretha Heitor Veríssimo, Renata Marques de Melo, Yu Zhang, Rodrigo Othávio de Assunçãao e Souza

    Objective To investigate the influence of different finishing/polishing techniques and in situ aging on the flexural strength (σ), surface roughness, and Candida albicans adherence of 5 mol% yttria-stabilized zirconia (ultratranslucent zirconia). Materials and methods A total of 120 zirconia bars (Prettau Anterior, Zirkonzahn) with dimensions of 8 × 2 × 0.5 mm were divided into 8 groups (n = 15) according to two factors: “in situ aging” (non-aged and aged (A)) and “finishing/polishing” (control (C), diamond rubber polishing (R), coarse grit diamond bur abrasion (B), and coarse grit diamond bur abrasion + diamond rubber polishing (BR)). Half of the samples from each group were subjected to a 60-day in situ aging by fixing the bars into cavities prepared in the posterior region of the base of complete or partial dentures of 15 patients. The samples were then subjected to the mini flexural (σ) test (1 mm/min). A total of 40 zirconia blocks (5 × 5 × 2 mm) were prepared and subjected to roughness (Ra) analyses and fungal adherence and complementary analyses (X-ray diffraction (XRD) and scanning electron microscopy (SEM)). The data of mean σ (MPa) and roughness Ra (μm) were statistically analyzed by two-way and one-way ANOVA, respectively, and Tukey’s test. The Weibull analysis was performed for σ data. The fungal adhesion (Log CFU/mL) data were analyzed by Kruskal–Wallis tests. Results For flexural resistance, the “finishing/polishing” factor was statistically significant (P = 0.0001); however, the “in situ aging” factor (P = 0.4458) was not significant. The non-aged (507.3 ± 115.7 MPa) and aged (487.6 ± 118.4 MPa) rubber polishing groups exhibited higher mean σ than the other techniques. The non-aged (260.2 ± 43.3 MPa) and aged (270.1 ± 48.8 MPa) bur abrasion groups presented lower σ. The coarse-grit diamond bur abrasion group (1.82 ± 0.61 µm) presented the highest roughness value (P = 0.001). Cell adhesion was not different among groups (P = 0.053). Group B presented the most irregular surface and the highest roughness Ra of 0.61 m. Conclusions The finishing of ultratranslucent zirconia might be preferably done with a diamond rubber polisher. Moreover, the protocols used did not interfere with Candida albicans adhesion. Clinical relevance Coarse-grit diamond burs might be avoided for finishing ultratranslucent monolithic zirconia, which might be preferably performed with a diamond rubber polisher.


  • Bond strength and Weibull analysis of fiber posts luted with different cement types and mechanically aged

    by Elis Janaina Lira dos Santos, Fernanda Campos, Alana Moura Xavier Dantas, Maria Luiza Lima Alves Lira, Vinícius Felipe Wandsher, Nathalia Ramos da Silva, Luiz Felipe Valandro, Rodrigo Othávio de Assunção Souza

    This study aimed to evaluate the influence of cement type and mechanical cycling on the push-out bond strength (σ) of fiber posts luted to root canals. Eighty bovine single-root teeth were prepared and the roots were included with chemically cured acrylic resin. The specimens were allocated into 8 groups (n = 10) considering the factors ‘cement’ (glass ionomer cement – GIC, resin reinforced glass ionomer cement – RRGIC, conventional dual-cure resin cement – CRC, and self-adhesive resin cement – SARC) and ‘mechanical cycling’ (non-aged and aged – mc). The fiber posts and roots dentin were treated according to the cement type and luted to root canals. Composite-cores were made for the groups submitted to mechanical cycling (1,000,000 cycles, 84 N, 4 Hz). Each root were cut into 4 disk-samples of 1.8 mm (thickness) and submitted to push-out testing. Data (MPa) were analyzed using two-way ANOVA, Tukey test (5%), and Weibull analysis. ANOVA revealed that cement (p < 0.001) was significant; however, the mechanical cycling had no effect on bond strength (p = 0.895). The CRC (4.36 ± 1.15 MPa), CRCmc (4.13 ± 0.75 MPa), GIC (4.29 ± 2.14 MPa), and GICmc (4.04 ± 1.18 MPa) groups showed higher (σ) than RRGIC (2.36 ± 1.00 MPa). Weibull Characteristic strength of the CRC and CRCmc were significantly higher than RRGICmc, and RRGIC. The mixed type of failure was the most common. Conventional dual-cure resin cement and glass ionomer cement presented higher push-out bond strength to root dentin regardless of mechanical cycling.


  • Can enamel etching with the Er:YAG laser be an alternative to the conventional phosphoric acid for bracket bonding? A systematic review and meta-analysis

    by Nathalia Ramos da Silva, Larissa Mendonça de Miranda, Isabelle Helena Gurgel de Carvalho, Lorena Marques Ferreira de Sena, Dayanne Monielle Duarte Moura, Mutlu Özcan, Rodrigo Othávio de Assunção e Souza

    This systematic review and meta-analysis aimed to evaluate the effect of Er:YAG laser etching on shear bond strength (SBS) of brackets bonded to the enamel and compare to the phosphoric acid (control). Electronic databases (PubMed, Scopus, and Web of Science) and a manual search were conducted up to January 2021. In vitro studies comparing Er:YAG laser and phosphoric acid etching for metal bracket bonding to human teeth, that performed aging of samples submitted to SBS tests were included. The risk of bias was assessed considering specific parameters. Statistical analysis was conducted using the RStudio statistical program for meta-analysis. Among 1456 potentially eligible studies, 19 were selected for full-text analysis, and 12 were included for qualitative and quantitative analysis. In the general meta-analysis, phosphoric acid etching showed higher SBS (n = 516; p = 0.02; I2 = 95.4%). The 100 mJ (p = 0.05; I2 = 76.2%) and p < 0.01; I2 = 89.5%) showed a significant difference, favoring phosphoric acid etching, however, there was no significant difference in the >100 mJ subgroup (p < 0.32; I2 = 93.3%). In the 500-thermocycle subgroup, phosphoric acid etching had a significantly higher SBS (p < 0.01; I2 = 96.2%), however, there was no significant difference in etching techniques for the 5000-cycle subgroup (p = 0.10; I2 = 69.1%). Although Er:YAG laser provides lower SBS than phosphoric acid etching, it provides an adequate bracket bonding. Further investigations to establish a laser protocol and clinical evidence are important for the consolidation of Er:YAG laser as a viable alternative to phosphoric acid.


  • Open Access

    CAD-FEA modeling and fracture resistance of bilayer zirconia crowns manufactured by the rapid layer technology

    by Julia Magalhães Costa Lima, Anna Karina Figueiredo Costa, Lilian Costa Anami, Karina Barbosa Souza, Nathalia Ramos da Silva, Renata Marques De Melo Marinho, Alexandre Luis Souto Borges, Marco Antonio Bottino, Mutlu Özcan, Rodrigo Othávio Assunção Souza

    In the RLT (Rapid Layer Technology), veneering ceramic and framework are fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) and then cemented to obtain the restoration. This study aimed to evaluate the effect of the thickness of veneering ceramic manufactured by the RLT technique on the fracture resistance (FR) of bilayer crowns with zirconia frameworks. Twenty zirconia frameworks and twenty feldspathic posterior crowns with two different veneering ceramic occlusal thicknesses (1mm=TF1; 2mm=TF2) were manufactured using CAD/CAM system. The specimens were luted to an epoxy resin abutment with resin cement and mechanically cycled (200N and 4.5×105 Pa, 37°C, 2×106 cycles, 3Hz). The FR test was performed (10kN, 0.5mm/min), and the specimens were analyzed in a stereomicroscope. For the stress analysis (finite element analysis, FEA), a 10kN load was equal to the in vitro test, and the principal stress was evaluated. The FR data were analyzed by Student’s t-test and Weibull's analysis. The thickness influenced the FR of bilayer crowns. The FR was higher in the TF2 than in the TF1 group. The TF2 group presented the highest characteristic strength compared to the group TF1. The predominant type of failure was delamination. The FEA showed higher stress concentrations below the loading application point at the veneering cement interface in the 1-mm-thick model. The bilayer crowns manufactured using the approach of 2mm of veneering ceramic promoted higher FR compared to the group with 1mm veneering ceramic. Also, the FEA showed that the veneer ceramic thickness has an effect on stress distribution in zirconia-based bilayer crowns.