    Advanced voltage selection model for a gas field electrical distribution grid

    by A.A. Yarkina, Khamitov, A.S. Sorogin, O.V. Arkhipova, Р.н. Хамитов

    Relevance. In the development of a gas fields, an important function is performed by the power supply system. One of the main criteria affecting the reliability of the power supply system is the correctly selected voltage class. In a market economy, on the one hand, the power supply system must be technically reliable, providing continuous power supply to consumers, on the other hand, it must be optimal in terms of capital and operating costs. Existing mathematical models for selecting the voltage class are based on the life cycle of a field, but they do not take into account the drilling period. Currently, many oil and gas companies are forming requirements for the power supply of drilling rigs via two overhead power line circuits. Aim. To develop a mathematical model for the rational choice of voltage for an electric distribution grid, taking into account the drilling period of gas wells and the entire life cycle of gas field development. Object. The power supply scheme of a gas field. Methods. Theory of experimental planning, calculation of discounted costs, statistical method. Results and conclusions. It was revealed that the nature of the electrical load of the drilling rig has a sharply variable load schedule, while that of a gas-condensate well cluster is uniform. To account for the feature of the electrical load, it is proposed to introduce the simultaneity coefficient in the mathematical model. Thus, the mathematical models take into account five factors: the number of gas-condensate well clusters, the length of the power line, the load growth coefficient, the load distribution coefficient, and the simultaneity coefficient. The authors have developed a mathematical model for choosing rational voltage and seven mathematical models for calculating discounted costs for voltage classes 3, 6, 10, 20, 35, 110, 220 kV. Mathematical models have the form of a regression equation of a polynomial type. The significance of the coefficients of the polynomials is estimated using the Student's t-criterion. The adequacy of mathematical models is verified by the Fisher's criterion. The accuracy of the model calculation is 11.36%, which is considered sufficient for technical and economic tasks. The rational voltage of the distribution electric grid of a particular deposit (Urat=35 kV) was selected. It was established that a correctly selected voltage class at the design stage, taking into account the drilling period and the entire life cycle of the field operation, can save up to 40% of discounted costs for the development of the distribution grid.

  • Open Access

    Automated system for optimal control of distribution electric network configuration

    by V.A. Rokhlov, R N Khamitov, S.N. Zherebtsov, A.A. Latyntseva, O.V. Arkhipova, Р.н. Хамитов

    Relevance. The need to develop and implement technical solutions aimed at minimizing energy losses in the power supply systems of the public utility sector. The key direction in this area is the development of automated systems for optimal control of the operating modes of electrical networks. The implementation of such systems is currently technically feasible due to the availability of a developed software and hardware base. Aim. To develop an integrated system that automates the full cycle of optimal network configuration management: from data collection and analysis of current operating modes to determining the optimal configuration and secure generation of control commands. Methods. The network operating mode is calculated using the nodal voltage method and the Newton–Raphson method. The mode is corrected using the sensitivity matrix. The optimal network configuration is determined by solving the combinatorial optimization problem using the branch and bound method. The control system architecture is modeled using the object-oriented UML language. Results and conclusions. The authors have developed the algorithmic support and architecture of the automated system for optimal control of the distribution electric network configuration. The algorithmic support includes four main components: an algorithm for calculating and correcting the network operating mode based on the Newton–Raphson method and sensitivity matrices, an algorithm for determining the possibility of controlling reclosers in automatic mode with checking the state of the switching device, an algorithm for determining the optimal network configuration using the branch and bound method, and an algorithm for generating a sequence of control commands that allows avoiding violation of mode restrictions on the switching time. The developed architecture of the control system is described as a UML model reflecting interaction with related systems and operating personnel, as well as the main functional modules.

  • Open Access

    Development and research of a full-order observer for the dynamic system «cable line – permanent magnet synchronous motor» in discrete time

    by Александр Савельевич Глазырин, Евгений Игоревич Попов, Владимир Анатольевич Копырин, Rustam N. Khamitov, Vladimir Z. Kovalev, Александр Александрович Филипас, Alexander A. Shchipkov, Yulia O. Kulesh, Семен Семенович Попов, Евгений Владимирович Боловин, et al.

    Relevance. Currently, the share of centrifugal electric pumps operating in intermittent modes is increasing, allowing for increased oil production from low- and medium-flow wells. This is achieved by switching the well to two-position control modes with separate pumping and fluid accumulation cycles. However, this significantly reduces the time it takes to bring the well up to operating mode, which can reach several minutes. This approach reduces the mean time between failures of submersible electric motors and components of the submersible section of the unit due to increased vibration amplitude and torsional oscillations compared to quasi-stationary processes during continuous well operation. The impact of starting currents and torques, which lead to excessive fatigue wear of the submersible section components, can be reduced by using closed-loop sensorless control systems for submersible electric motor drives. This necessitates the development of methods for identifying unmeasured state variables of submersible electric motors, such as the flux vector and rotor angular velocity, using full-order state observers. Aim. Development and research of a rotor speed and load torque full-order observer for the dynamic system «cable line – permanent magnet synchronous motor» based on explicit mathematical models in discrete time for the implementation of closed-loop sensorless control systems for the electric drive of centrifugal electric pump units. Methods. The work used methods of system analysis and structural-parametric synthesis of dynamic systems, methods of identifying unmeasured state variables of dynamic systems based on state observers, methods of numerical mathematical modeling of dynamic systems described by systems of stiff differential equations, and methods of solving systems of nonlinear algebraic equations. Results. The authors have developed the adaptive mathematical model of a rotor speed and load torque full-order observer for the dynamic system «cable line – permanent magnet synchronous motor». The observer performance was studied under typical operating conditions and when the parameters of its customizable model deviated from the reference values. For all operating conditions, the relative errors in estimating the rotor angular velocity and shaft drag torque were less than 1.5 and 1%, respectively.

  • Open Access

    Analysis of existing approaches to monitoring and diagnostics of the active part of power transformers

    by Olga V. Arkhipova, Vladimir Z. Kovalev, Ruslan V. Saifullin

    Subject of research: monitoring and diagnostics of the condition of the active part of power transformers. Purpose of research: identification of promising trends in the development of methods for monitoring and diagnosing the state of the active part of power transformers. Object of research: power transformers. Methods of research: critical system analysis. Main results of research: the problem of monitoring and diagnosing the condition of the active part of power transformers, including windings, is considered. It is noted that a significant number (more than four million units) of distribution transformers are in operation in the Russian Federation. The causes of emergency failures of the specified class of power transformers are analyzed. One of the main causes of failures is highlighted – a winding circuit in the transformer winding. Attention is focused on the problem of monitoring the state of the active part of the transformer and on the diagnosis of the development of short circuits in the transformer winding. The presence of several groups of methods for monitoring and diagnosing winding circuits of transformer windings is shown. The economic attractiveness of monitoring and diagnostics based on the reaction to artificial electromagnetic influences, and monitoring and diagnostics based on the reaction to natural electromagnetic influences is shown.


  • Open Access

    Rational dimension of a basis of a regression model for adaptive short-term forecasting the state of a discrete nonstationary dynamic system

    by Александр Савельевич Глазырин, Евгений Владимирович Боловин, Olga V. Arkhipova, Владимир Захарович Ковалев, Rustam N. Khamitov, Сергей Николаевич Кладиев, Александр Александрович Филипас, Вадим Владимирович Тимошкин, Vladimir A. Kopyrin, Evgeniia A. Beliauskene

    Relevance. Today, there are many methodologies for predicting power consumption of various objects. However, there is no a general methodology that is suitable for all types of energy systems, including the sectoral characteristics of small northern settlements and other objects with the stochastic nature of electricity consumption schedules. At the same time, during the development of problem-oriented forecasting methods, it is necessary to take into account computational and statistical features of forecasted time series to the maximum and apply them adequately. The mentioned circumstance prompts the creation of criteria-indicators that allow evaluating the quality of the applied model for solving the forecasting problem, correctness of its construction and correctness of applying a priori information about the object and its physical properties.Aim. Develop and apply the criteria-indicators, which allow evaluating the quality of the forecast regression model and the influence of the dimensionality of such model base on a forecasting error. Methods. The choice of rational dimensionality of the regression model basis for the adaptive forecasting problem is based on the known and developed criteria-indicators. The main provisions of such criteria-indicators were formulated, which provide an assessment of the quality of conditioning of an equivalent square matrix, the presence of uninformative elements of the matrix, and linear dependence of the columns. Results. Based on the analysis of criteria-indicators, the authors selected a rational dimension of the regression model basis for the problem of adaptive short-term forecasting of the state of discrete non-stationary dynamic systems. Conclusions. The authors have previously selected the most promising criteria-indicators and developed a normalized difference factor of diagonal predominance. This allows us to evaluate the influence of the basis size change on the regression model quality when building an approach of adaptive short-term forecasting of electricity consumption by autonomous power systems of small northern settlements on the basis of regression analysis methods. Based on the analysis of criteria-indicators the authors obtained information about the influence of the regression model basis dimension on the forecasting problem solution error. The authors stated the further stages of research to reduce this error. The paper introduces and describes one of the ways to improve the forecasting model quality. The dependence of the forecasting error on the size of the regression model basis were revealed; the criteria-indicators considered in the article were successfully applied. It is confirmed that the pre-selected and developed criteria-indicators make it possible, at the stage of compiling an equivalent square matrix and performing preliminary actions on it, to track changes within the matrix. The changes will lead to improvement in the solution of the problem of adaptive short-term forecasting. Актуальность. На сегодняшний день существует множество методологий прогнозирования электропотребления различных объектов. Однако нет общей методологии, которая подходит для всех типов энергосистем, в том числе для отраслевых особенностей малых северных поселений и других объектов со стохастическим характером графиков потребления электрической энергии. При этом в ходе разработки проблемно-ориентированных методов прогнозирования необходимо по максимуму учитывать вычислительные и статистические особенности прогнозируемых временных рядов и адекватно их применять. Отмеченное обстоятельство побуждает к созданию критериев-индикаторов, позволяющих оценить качество применяемой модели для решения задачи прогнозирования, правильность ее построения и корректность применения априорной информации об объекте и его физических свойствах. Цель: разработка и применение критериев-индикаторов, позволяющих произвести оценку качества составления прогнозной регрессионной модели и влияние размерности базиса такой модели на погрешность прогнозирования. Методы. Выбор рациональной размерности базиса регрессионной модели для задачи адаптивного прогнозирования базируется на известных и разработанном критериях-индикаторах. Были сформулированы основные положения таких критериев-индикаторов, которые дают оценку качества обусловленности эквивалентной квадратной матрицы, наличия малоинформативных элементов матрицы, линейной зависимости столбцов. Результаты. На основании анализа критериев-индикаторов была выбрана рациональная размерность базиса регрессионной модели для задачи адаптивного...


  • Open Access

    АДАПТИВНОЕ КРАТКОСРОЧНОЕ ПРОГНОЗИРОВАНИЕ ПОТРЕБЛЕНИЯ ЭЛЕКТРОЭНЕРГИИ АВТОНОМНЫМИ ЭНЕРГОСИСТЕМАМИ МАЛЫХ СЕВЕРНЫХ ПОСЕЛЕНИЙ НА ОСНОВЕ МЕТОДОВ КОРРЕЛЯЦИОННОГО АНАЛИЗА

    by Юсуп Ниязбекович Исаев, Ольга Владимировна Архипова, Владимир Захарович Ковалев, Рустам Нуриманович Хамитов

    Ссылка для цитирования: Адаптивное краткосрочное прогнозирование потребления электроэнергии автономными энергосистемами малых северных поселений на основе методов корреляционного анализа / Ю.Н. Исаев, О.В. Архипова, В.З. Ковалев, Р.Н. Хамитов // Известия Томского политехнического университета. Инжиниринг георесурсов. – 2023. – Т. 334. – № 2. – С. 224-239. Одной из основных проблем построения энергоэффективных и нересурсоемких систем децентрализованного электроснабжения Арктической зоны и районов Крайнего Севера является прогнозирование потребления электрической энергии малыми северными поселениями. Среди существующих методов, дающих приемлемый по точности результат, можно выделить подходы на базе эконометрического метода ARIMA. Рассмотрен метод на основе разложения Вольда и корреляционных функций стохастического процесса, построена адаптивная модель разностного уравнения, позволяющая прогнозировать процесс энергопотребления активной мощности автономных систем малого поселения на интервале 0–4 часа, за счет сведения стохастического процесса к стационарному Марковскому процессу с короткой памятью. Цель: построение методики краткосрочного прогноза потребления электрической энергии автономными энергосистемами малых северных поселений с учетом специфики энергопотребления в условиях Арктической зоны и Крайнего Севера на основании стохастического ряда данных об электрической энергии, потребленной поселением за предшествующий период. Методы: подход к получению краткосрочного прогноза потребления электроэнергии автономными энергосистемами малых северных поселений, который базируется на эконометрическом методе ARIMA. При этом конструируется разностное уравнение для детерминированной и случайной компонент имеющегося стохастического ряда энергопотребления; используются декомпозиция Вольда и корреляционные функций процесса энергопотребления. Для адаптации модели исследуемый стохастический процесс сводится к Марковскому процессу с короткой памятью. Для этого необходимо использовать разностный оператор, который уменьшает относительный вклад детерминированной составляющей процесса потребления. Результаты. На основе декомпозиции Вольда и корреляционных функций удалось получить модель, дающую краткосрочный прогноз энергопотребления активной мощности на интервал упреждения до 4 часов. Выводы. На основе декомпозиции Вольда и корреляционных функций стохастического процесса авторам работы удалось получить адаптивную модель разностного уравнения, позволяющую прогнозировать процесс энергопотребления активной мощности автономных систем малого поселения с интервалом упреждения в 4 часа. Стационарность случайного процесса производилась с помощью введения разностного оператора первого порядка, позволяющего уменьшить относительный вклад детерминированной составляющей стохастического ряда. Авторам удалось свести процесс к стационарному Марковскому процессу с короткой памятью. Коэффициенты разложения разностного уравнения оценивались с помощью решения нелинейного уравнения, заключающегося в поиске глобального максимума функции правдоподобия. Построенные 90 % вероятностные границы позволяют говорить об удовлетворительной подстройке адаптивных параметров разностного уравнения для...


  • Open Access

    МЕТОДИКА МОДЕЛИРОВАНИЯ РЕГИОНАЛЬНО ОБОСОБЛЕННОГО ЭЛЕКТРОТЕХНИЧЕСКОГО КОМПЛЕКСА

    by Архипова Ольга Владимировна (Olga V. Arkhipova), Ковалев Владимир Захарович (Vladimir Z. Kovalev), Хамитов Рустам Нуриманович (Rustam N. Khamitov)

    Актуальность исследования обусловлена необходимостью устранения разрыва между существующими подходами к моделированию изолированных систем электроснабжения и необходимостью учета динамических процессов в их физически разнородных подсистемах, образующих совокупность, при наличии слабых связей и слабых взаимодействий между единичными системами. Цель исследования: сконструировать проблемно-ориентированный численный метод, непосредственно применимый к математическим моделям совокупности изолированных систем электроснабжения и существенно превосходящий по критерию «время счета – точность счета» универсальные численные методы. Объект: электротехнический комплекс, состоящий из совокупности изолированных систем электроснабжения, объединенных слабыми связями и слабыми взаимодействиями. Методы. При анализе формы и структуры исходной математической модели совокупности электротехнических комплексов, состоящих из изолированных систем электроснабжения, объединенных слабыми связями и слабыми взаимодействиями, и при конструировании проблемно-ориентированного численного метода использованы: энергетический подход к построению математических моделей электротехнических комплексов и систем, теория численных методов решения жестких систем дифференциальных уравнений, корректные допущения при составлении математических моделей и компьютерное моделирование. Результаты. Введено в рассмотрение понятие «Регионально обособленный электротехнический комплекс», и выявлены его характерные признаки. Показана возможность создания новых алгоритмов управления «Регионально обособленным электротехническим комплексом», в целях снижения возможного экологического ущерба и средней расчётной себестоимости производства электроэнергии электростанциями, входящими в «Регионально обособленный электротехнический комплекс». Выявлена исходная структура математической модели «Регионально обособленного электротехнического комплекса». Показано принципиальное отличие структуры данной модели от модели в нормальной форме Коши. Обосновано принципиальное наличие свойств жесткости и сверхжесткости у анализируемого класса моделей. Сконструирован и реализован в программе BKM-3 проблемно ориентированный трехшаговый численный метод, применимый к исходной математической модели «Регионально обособленного электротехнического комплекса». Проведен численный эксперимент, показавший, на идеализированных математических моделях «Регионально обособленного электротехнического комплекса», существенное преимущество программы BKM-3, по критерию «время счета – точность счета» в области применимости.


  • Open Access

    SIMULATION OF DYNAMIC MODES OF ASYNCHRONOUS MACHINES WITH REGARD TO THERMAL TRANSITION PROCESSES

    by Arkhipova O.V., Kovalev V.Z., Kovaleva S.E.