Jason Cobb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jason Cobb has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Alexander T. Adams
School of Interactive Computing, Georgia Institute of Technology, Atlanta, Georgia, USA
2 shared publications - Kefan Song
Georgia Institute of Technology
2 shared publications - Sixuan Wu
School of Interactive Computing, Georgia Institute of Technology, Atlanta, Georgia, USA
2 shared publications Ahmad Akhgar
Clinical Pharmacology and Quantitative Pharmacology, AstraZeneca, Gaithersburg, Maryland
1 shared publication- Ajai Rajabalan
Med Coll Georgia, Dept Med, Wellstar Campus, Marietta, GA USA
1 shared publication - Alton Brad Farris
Department of Pathology, Emory University, Atlanta, Georgia, USA
1 shared publication
Latest Publications
- 1 June 2025
- Published by Journal of Graduate Medical Education in Journal of Graduate Medical Education
- Vol. 17 (3) , 304-307
RYSEFAX: A Virtual Recruitment Initiative Targeting Internal Medicine Fellowship Applicants Committed to Program Inclusion
Background Graduate medical education programs have implemented strategies to enhance recruitment of diverse applicants who value inclusive training environments, yet there are few published fellowship recruitment strategies. Objective To assess the acceptability and feasibility of a virtual recruitment and engagement program for internal medicine (IM) fellowship applicants. Methods In 2020, we developed a virtual recruitment program (RYSEFAX) centered on IM fellowship applicants. From 2020 to 2022, fellowship programs invited all self-declared underrepresented in medicine applicants who interviewed in their respective programs; since 2023, the program expanded to all interviewed applicants. Participants met with current fellows, faculty, and leadership in one-on-one sessions and groups. Program components included introduction to the department chair, discussions with fellowship and diversity, equity, and inclusion leaders, breakouts with current fellows, and conversations with mentor-mentee teams. Applicant participation rates, fellowship Match outcomes, and 2022-2023 participant surveys were used to examine perceptions of program value. Results From 2020 to 2023, 721 individuals were invited, 158 attended, and 50 (31%) matched with one of our fellowship programs. In 2022 and 2023 feedback surveys, respondents (n=22) indicated increased interest and ranking of one of our fellowship programs after RYSEFAX: 19 (86%) indicated that participation increased their likelihood of seeking employment with us, and all 22 ranked our institution following attendance. Open-ended feedback described perceptions that RYSEFAX strengthened our reputation as an inclusive training environment. Conclusions A virtual fellowship recruitment and engagement program for subspecialty medical fellowship programs is feasible and appears to positively influence applicant perceptions of the program.
- 1 June 2025
- Published by Journal of Graduate Medical Education in Journal of Graduate Medical Education
- Vol. 17 (3) , 304-307
RYSEFAX: A Virtual Recruitment Initiative Targeting Internal Medicine Fellowship Applicants Committed to Program Inclusion
Background Graduate medical education programs have implemented strategies to enhance recruitment of diverse applicants who value inclusive training environments, yet there are few published fellowship recruitment strategies. Objective To assess the acceptability and feasibility of a virtual recruitment and engagement program for internal medicine (IM) fellowship applicants. Methods In 2020, we developed a virtual recruitment program (RYSEFAX) centered on IM fellowship applicants. From 2020 to 2022, fellowship programs invited all self-declared underrepresented in medicine applicants who interviewed in their respective programs; since 2023, the program expanded to all interviewed applicants. Participants met with current fellows, faculty, and leadership in one-on-one sessions and groups. Program components included introduction to the department chair, discussions with fellowship and diversity, equity, and inclusion leaders, breakouts with current fellows, and conversations with mentor-mentee teams. Applicant participation rates, fellowship Match outcomes, and 2022-2023 participant surveys were used to examine perceptions of program value. Results From 2020 to 2023, 721 individuals were invited, 158 attended, and 50 (31%) matched with one of our fellowship programs. In 2022 and 2023 feedback surveys, respondents (n=22) indicated increased interest and ranking of one of our fellowship programs after RYSEFAX: 19 (86%) indicated that participation increased their likelihood of seeking employment with us, and all 22 ranked our institution following attendance. Open-ended feedback described perceptions that RYSEFAX strengthened our reputation as an inclusive training environment. Conclusions A virtual fellowship recruitment and engagement program for subspecialty medical fellowship programs is feasible and appears to positively influence applicant perceptions of the program.
- Open Access
- 23 December 2024
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 9 (1) , e62770
Pump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation
Background: Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. Objective: The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? Methods: To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. Results: In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. Conclusions: In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.
- 23 December 2024
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 9 (1) , e62770
Open AccessPump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation
Background: Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. Objective: The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? Methods: To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. Results: In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. Conclusions: In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.
- Open Access
- 8 July 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Pump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation (Preprint)
BACKGROUND Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. OBJECTIVE The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? METHODS To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. RESULTS In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. CONCLUSIONS In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.
- 8 July 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessPump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation (Preprint)
BACKGROUND Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. OBJECTIVE The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? METHODS To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. RESULTS In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. CONCLUSIONS In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.
- Open Access
- 23 May 2024
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (9) , 1104-1109
Implementing nasal povidone-iodine decolonization to reduce infections in hemodialysis units: a qualitative assessment
Background: A substantial proportion of patients undergoing hemodialysis carry Staphylococcus aureus in their noses, and carriers are at increased risk of S. aureus bloodstream infections. Our pragmatic clinical trial implemented nasal povidone-iodine (PVI) decolonization for the prevention of bloodstream infections in the novel setting of hemodialysis units.Objective: We aimed to identify pragmatic strategies for implementing PVI decolonization among patients in outpatient hemodialysis units.Design: Qualitative descriptive study.Setting: Outpatient hemodialysis units affiliated with five US academic medical centers. Units varied in size, patient demographics, and geographic location.Interviewees: Sixty-six interviewees including nurses, hemodialysis technicians, research coordinators, and other personnel.Methods: We conducted interviews with personnel affiliated with all five academic medical centers and conducted thematic analysis of transcripts.Results: Hemodialysis units had varied success with patient recruitment, but interviewees reported that patients and healthcare personnel (HCP) found PVI decolonization acceptable and feasible. Leadership support, HCP engagement, and tailored patient-focused tools or strategies facilitated patient engagement and PVI implementation. Interviewees reported both patients and HCP sometimes underestimated patients’ infection risks and experienced infection-prevention fatigue. Other HCP barriers included limited staffing and poor staff engagement. Patient barriers included high health burdens, language barriers, memory issues, and lack of social support.Conclusion: Our qualitative study suggests that PVI decolonization would be acceptable to patients and clinical personnel, and implementation is feasible for outpatient hemodialysis units. Hemodialysis units could facilitate implementation by engaging unit leaders, patients and personnel, and developing education for patients about their infection risk.
- 23 May 2024
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 45 (9) , 1104-1109
Open AccessImplementing nasal povidone-iodine decolonization to reduce infections in hemodialysis units: a qualitative assessment
Background: A substantial proportion of patients undergoing hemodialysis carry Staphylococcus aureus in their noses, and carriers are at increased risk of S. aureus bloodstream infections. Our pragmatic clinical trial implemented nasal povidone-iodine (PVI) decolonization for the prevention of bloodstream infections in the novel setting of hemodialysis units.Objective: We aimed to identify pragmatic strategies for implementing PVI decolonization among patients in outpatient hemodialysis units.Design: Qualitative descriptive study.Setting: Outpatient hemodialysis units affiliated with five US academic medical centers. Units varied in size, patient demographics, and geographic location.Interviewees: Sixty-six interviewees including nurses, hemodialysis technicians, research coordinators, and other personnel.Methods: We conducted interviews with personnel affiliated with all five academic medical centers and conducted thematic analysis of transcripts.Results: Hemodialysis units had varied success with patient recruitment, but interviewees reported that patients and healthcare personnel (HCP) found PVI decolonization acceptable and feasible. Leadership support, HCP engagement, and tailored patient-focused tools or strategies facilitated patient engagement and PVI implementation. Interviewees reported both patients and HCP sometimes underestimated patients’ infection risks and experienced infection-prevention fatigue. Other HCP barriers included limited staffing and poor staff engagement. Patient barriers included high health burdens, language barriers, memory issues, and lack of social support.Conclusion: Our qualitative study suggests that PVI decolonization would be acceptable to patients and clinical personnel, and implementation is feasible for outpatient hemodialysis units. Hemodialysis units could facilitate implementation by engaging unit leaders, patients and personnel, and developing education for patients about their infection risk.
- 27 September 2023
- Published by American Society of Nephrology (ASN)
2023 ASN Nephrology Fellow Survey
Takeaways from ASN’s 10th Annual Nephrology Fellow Survey
- 27 September 2023
- Published by American Society of Nephrology (ASN)
2023 ASN Nephrology Fellow Survey
Takeaways from ASN’s 10th Annual Nephrology Fellow Survey
- 5 May 2022
- Published by Wolters Kluwer Health in Kidney360
- Vol. 3 (8) , 1359-1366
Proportion of Hemodialysis Treatments with High Ultrafiltration Rate and the Association with Mortality
Key Points: Episodes of hemodialysis (HD) with high ultrafiltration rates (>13 ml/kg per hour) occurred frequently in 1050 incident dialysis patients. Younger age, diabetes, heart failure, higher albumin, being a man, shorter treatment time, and lower weight were associated with high UFR. Increasing numbers of dialysis sessions with high ultrafiltration rates were associated with higher all-cause and cardiovascular mortality. Background: Rapid fluid removal during hemodialysis has been associated with increased mortality. The limit of ultrafiltration rate (UFR) monitored by the Centers for Medicare & Medicaid Services is 13 ml/kg per hour. It is not clear if the proportion of treatments with high UFR is associated with higher mortality. We examined the association of proportion of dialysis treatments with high UFR and mortality in end stage kidney failure patients receiving hemodialysis. Methods: This was a retrospective study of incident patients initiating hemodialysis between January 1, 2010, and December 31, 2019, at Emory dialysis centers. The proportion of treatments with high UFR (>13 ml/kg per hour) per patient was calculated using data from the initial 3 months of dialysis therapy. Patients were categorized on the basis of quartiles of proportion of dialysis sessions with high UFR. Risk of death and survival probabilities were calculated and compared for all quartiles. Results: Of 1050 patients eligible, the median age was 59 years, 56% were men, and 91% were Black. The median UFR was 6.5 ml/kg per hour, and the proportion of sessions with high UFR was 5%. Thirty-one percent of patients never experienced high UFR. Being a man, younger age, shorter duration of hemodialysis sessions, lower weight, diabetic status, higher albumin, and history of heart failure were associated with a higher proportion of sessions with high UFR. Patients in the higher quartile (26% dialysis with high UFR, average UFR 9.8 ml/kg per hour, median survival of 5.6 years) had a higher risk of death (adjusted hazard ratio 1.54; 95% CI, 1.13 to 2.10) compared with those in the lower quartile (0% dialysis with high UFR, average UFR 4.7 ml/kg per hour, median survival 8.8 years). Conclusions: Patients on hemodialysis who did not experience frequent episodes of elevated UFR during the first 3 months of their dialysis tenure had a significantly lower risk of death compared with patients with frequent episodes of high UFR.
- 5 May 2022
- Published by Wolters Kluwer Health in Kidney360
- Vol. 3 (8) , 1359-1366
Proportion of Hemodialysis Treatments with High Ultrafiltration Rate and the Association with Mortality
Key Points: Episodes of hemodialysis (HD) with high ultrafiltration rates (>13 ml/kg per hour) occurred frequently in 1050 incident dialysis patients. Younger age, diabetes, heart failure, higher albumin, being a man, shorter treatment time, and lower weight were associated with high UFR. Increasing numbers of dialysis sessions with high ultrafiltration rates were associated with higher all-cause and cardiovascular mortality. Background: Rapid fluid removal during hemodialysis has been associated with increased mortality. The limit of ultrafiltration rate (UFR) monitored by the Centers for Medicare & Medicaid Services is 13 ml/kg per hour. It is not clear if the proportion of treatments with high UFR is associated with higher mortality. We examined the association of proportion of dialysis treatments with high UFR and mortality in end stage kidney failure patients receiving hemodialysis. Methods: This was a retrospective study of incident patients initiating hemodialysis between January 1, 2010, and December 31, 2019, at Emory dialysis centers. The proportion of treatments with high UFR (>13 ml/kg per hour) per patient was calculated using data from the initial 3 months of dialysis therapy. Patients were categorized on the basis of quartiles of proportion of dialysis sessions with high UFR. Risk of death and survival probabilities were calculated and compared for all quartiles. Results: Of 1050 patients eligible, the median age was 59 years, 56% were men, and 91% were Black. The median UFR was 6.5 ml/kg per hour, and the proportion of sessions with high UFR was 5%. Thirty-one percent of patients never experienced high UFR. Being a man, younger age, shorter duration of hemodialysis sessions, lower weight, diabetic status, higher albumin, and history of heart failure were associated with a higher proportion of sessions with high UFR. Patients in the higher quartile (26% dialysis with high UFR, average UFR 9.8 ml/kg per hour, median survival of 5.6 years) had a higher risk of death (adjusted hazard ratio 1.54; 95% CI, 1.13 to 2.10) compared with those in the lower quartile (0% dialysis with high UFR, average UFR 4.7 ml/kg per hour, median survival 8.8 years). Conclusions: Patients on hemodialysis who did not experience frequent episodes of elevated UFR during the first 3 months of their dialysis tenure had a significantly lower risk of death compared with patients with frequent episodes of high UFR.
- 30 September 2021
- Published by Wolters Kluwer Health in Kidney360
- Vol. 2 (9) , 1473-1481
Collagen Type III and VI Remodeling Biomarkers Are Associated with Kidney Fibrosis in Lupus Nephritis
Key Points: Prognostic biomarkers that identify patients with SLE at risk of developing lupus nephritis and progressing to kidney failure are needed. Tubulointerstitial fibrosis is an important pathologic feature of lupus nephritis and is associated with kidney disease progression. Circulatory and urinary markers of collagen type III and type VI remodeling noninvasively reflect levels of kidney fibrosis in patients with lupus nephritis. Background: Lupus nephritis (LN) occurs in <40% of patients with SLE. Reliable biomarkers of kidney damage are needed to identify patients with SLE at risk of developing LN to improve screening, treat the disease earlier, and halt progression to kidney failure. Novel biomarkers of extracellular matrix remodeling were evaluated as markers of kidney fibrosis and disease activity in patients with LN. Methods: Biomarkers of the interstitial collagen type III (PRO-C3) and type VI (PRO-C6) formation and of collagen type III (C3M) degradation were evaluated in the serum and urine of 40 patients with LN, 20 patients with SLE but without LN, 20 healthy controls, and ten biopsy controls (histologic kidney inflammation/damage without SLE). Their association with histologic markers of interstitial fibrosis and tubular atrophy, with inflammatory cell infiltration and with disease activity and chronicity in the patients with LN was assessed. Results: Despite PRO-C3 (serum) and PRO-C6 (serum and urine) being significantly elevated in patients with LN compared with healthy controls, the markers did not differentiate patients with LN from those with SLE. C3M (urine) levels were not different in LN compared with the other groups. C3M (urine) strongly correlated and PRO-C6 (serum and urine) inversely correlated with kidney function (eGFR). The biomarkers of interstitial collagen turnover PRO-C6 (serum) and C3M (urine) correlated with histologic markers of interstitial fibrosis, tubular atrophy, and monocyte infiltration. Conclusions: Noninvasive collagen turnover biomarkers are promising tools to identify patients with SLE with kidney histologic modifications.
- 30 September 2021
- Published by Wolters Kluwer Health in Kidney360
- Vol. 2 (9) , 1473-1481
Collagen Type III and VI Remodeling Biomarkers Are Associated with Kidney Fibrosis in Lupus Nephritis
Key Points: Prognostic biomarkers that identify patients with SLE at risk of developing lupus nephritis and progressing to kidney failure are needed. Tubulointerstitial fibrosis is an important pathologic feature of lupus nephritis and is associated with kidney disease progression. Circulatory and urinary markers of collagen type III and type VI remodeling noninvasively reflect levels of kidney fibrosis in patients with lupus nephritis. Background: Lupus nephritis (LN) occurs in <40% of patients with SLE. Reliable biomarkers of kidney damage are needed to identify patients with SLE at risk of developing LN to improve screening, treat the disease earlier, and halt progression to kidney failure. Novel biomarkers of extracellular matrix remodeling were evaluated as markers of kidney fibrosis and disease activity in patients with LN. Methods: Biomarkers of the interstitial collagen type III (PRO-C3) and type VI (PRO-C6) formation and of collagen type III (C3M) degradation were evaluated in the serum and urine of 40 patients with LN, 20 patients with SLE but without LN, 20 healthy controls, and ten biopsy controls (histologic kidney inflammation/damage without SLE). Their association with histologic markers of interstitial fibrosis and tubular atrophy, with inflammatory cell infiltration and with disease activity and chronicity in the patients with LN was assessed. Results: Despite PRO-C3 (serum) and PRO-C6 (serum and urine) being significantly elevated in patients with LN compared with healthy controls, the markers did not differentiate patients with LN from those with SLE. C3M (urine) levels were not different in LN compared with the other groups. C3M (urine) strongly correlated and PRO-C6 (serum and urine) inversely correlated with kidney function (eGFR). The biomarkers of interstitial collagen turnover PRO-C6 (serum) and C3M (urine) correlated with histologic markers of interstitial fibrosis, tubular atrophy, and monocyte infiltration. Conclusions: Noninvasive collagen turnover biomarkers are promising tools to identify patients with SLE with kidney histologic modifications.