Kefan Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kefan Song has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Alexander T. Adams
School of Interactive Computing, Georgia Institute of Technology, Atlanta, Georgia, USA
2 shared publications - Jason Cobb
Jason Cobb, MD, is an Associate Professor of Medicine, Division of Renal Medicine, Emory University School of Medicine, Atlanta, Georgia, USA
2 shared publications - Sixuan Wu
School of Interactive Computing, Georgia Institute of Technology, Atlanta, Georgia, USA
2 shared publications - Alexander Adams
Georgia Institute of Technology
1 shared publication Ilan Mandel
Cornell Tech
1 shared publication- Jason Cobb
Emory University School of Medicine
1 shared publication
Latest Publications
- Open Access
- 30 July 2025
- Published by Springer Nature in Research Square
SpectraPhone: A Smartphone Based Spectrometer for High-Resolution Urinalysis
Chronic kidney disease (CKD) affects millions worldwide but remains under-diagnosed, especially in resource-limited settings. Current diagnostic methods, including visual and dipstick urinalysis, lack quantitative accuracy, while laboratory-based tests remain inaccessible for routine or remote monitoring. Here we present SpectraPhone, a smartphone-integrated, portable spectrometer designed for quantitative, point-of-care urinalysis. Leveraging the smartphone's built-in camera and flashlight, SpectraPhone captures high-resolution spectral data to accurately quantify hematuria and albuminuria, which are both biomarkers of CKD. Through rigorous optical characterization and empirical validation, SpectraPhone demonstrates superior quantification performance, accurately measuring red blood cell concentrations (R2=0.9913, RMSE=61.6086 RBC/μL, MAE=43.9077 RBC/μL) and albumin levels (R2=0.9981, RMSE=11.8525 mg/dL, MAE=8.4985 mg/dL), significantly surpassing the capabilities of conventional qualitative methods. With the addition of bromophenol blue reagent, SpectraPhone achieves more accurate urine albumin measurements (R2=0.9997, RMSE=4.2583 mg/dL, MAE=3.2625 mg/dL), enabling clinical-grade albuminuria detection. SpectraPhone’s affordability, ease of use, and robust performance highlight its potential to transform routine CKD screening, facilitate early detection, improve disease management, and increase healthcare access globally.
- 30 July 2025
- Published by Springer Nature in Research Square
Open AccessSpectraPhone: A Smartphone Based Spectrometer for High-Resolution Urinalysis
Chronic kidney disease (CKD) affects millions worldwide but remains under-diagnosed, especially in resource-limited settings. Current diagnostic methods, including visual and dipstick urinalysis, lack quantitative accuracy, while laboratory-based tests remain inaccessible for routine or remote monitoring. Here we present SpectraPhone, a smartphone-integrated, portable spectrometer designed for quantitative, point-of-care urinalysis. Leveraging the smartphone's built-in camera and flashlight, SpectraPhone captures high-resolution spectral data to accurately quantify hematuria and albuminuria, which are both biomarkers of CKD. Through rigorous optical characterization and empirical validation, SpectraPhone demonstrates superior quantification performance, accurately measuring red blood cell concentrations (R2=0.9913, RMSE=61.6086 RBC/μL, MAE=43.9077 RBC/μL) and albumin levels (R2=0.9981, RMSE=11.8525 mg/dL, MAE=8.4985 mg/dL), significantly surpassing the capabilities of conventional qualitative methods. With the addition of bromophenol blue reagent, SpectraPhone achieves more accurate urine albumin measurements (R2=0.9997, RMSE=4.2583 mg/dL, MAE=3.2625 mg/dL), enabling clinical-grade albuminuria detection. SpectraPhone’s affordability, ease of use, and robust performance highlight its potential to transform routine CKD screening, facilitate early detection, improve disease management, and increase healthcare access globally.
- Open Access
- 23 December 2024
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 9 (1) , e62770
Pump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation
Background: Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. Objective: The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? Methods: To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. Results: In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. Conclusions: In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.
- 23 December 2024
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 9 (1) , e62770
Open AccessPump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation
Background: Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. Objective: The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? Methods: To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. Results: In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. Conclusions: In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.
- Open Access
- 8 July 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Pump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation (Preprint)
BACKGROUND Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. OBJECTIVE The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? METHODS To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. RESULTS In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. CONCLUSIONS In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.
- 8 July 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessPump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation (Preprint)
BACKGROUND Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. OBJECTIVE The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? METHODS To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. RESULTS In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. CONCLUSIONS In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.