    μMobileScan: A Smartphone Whole Slide Imaging App for Red Blood Cell Counting with Real-time Guidance

    by Sixuan Wu, Jung Hyun Bae, Alexander T. Adams

    Red blood cell counting is an essential metric in hematology analysis for disease diagnosis. Low red blood cell count can indicate anemia, and high red blood cell count can indicate tumors. The current clinical standard for counting the cells involves human experts counting the cells on hemocytometers through a microscope. This approach is labor-intensive and volatile. The manual process of counting cells via hemocytometer has no record (i.e., images) other than the clinicians' count. Whole slide imaging (WSI) systems can be used for slide scanning and digitization, but the high cost limits access to WSI technology. We propose a smartphone app called μMobileScan to make this measure more readily available. μMobileScan solely relies on commonly available tools, smartphone cameras, and microscopes, to reconstruct a virtual WSI hemocytometer by providing real-time guidance to the users and operating cell counting on the constructed images. We conducted studies to evaluate the WSI construction quality, learning curve, and cell counting accuracy demonstrating usability. The studies demonstrated the impact of scanning routes and overlap percentage on feature mapping. The learning curve evaluation on 8 participants illustrated that our system can guide users to scan the hemocytometer with consistent overlap percentages, and the scanning time and success rate converge after 5 trials. Usability testing with four participants (two experts and two novices) on de-identified samples from three donors under various configurations achieved high cell counting accuracy (MAPE = 1.40%, SDAPE = 1.48%). Evaluations across diverse hardware and optical configurations demonstrated the robustness and practicality of the proposed system.


  • Open Access

    LumiBite: An In-the-Wild Technology Probe Exploring Personalized bottom-up Lighting Lunchbox for Enhanced Dining Experiences

    by Haiqing Xu, Xiwen Yao, Sixuan Wu, Jung Hyun Bae, Zhifan Guo, Dian Lv, Zhihao Yao, HyunJoo Oh, Alexander T Adams

  • Open Access

    Pump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation

    by Sixuan Wu, Kefan Song, Jason Cobb, Alexander T Adams

    Background: Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. Objective: The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? Methods: To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. Results: In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. Conclusions: In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.


  • Open Access

    Pump-Free Microfluidics for Cell Concentration Analysis on Smartphones in Clinical Settings (SmartFlow): Design, Development, and Evaluation (Preprint)

    by Sixuan Wu, Kefan Song, Jason Cobb, Alexander T Adams

    BACKGROUND Cell concentration in body fluid is an important factor for clinical diagnosis. The traditional method involves clinicians manually counting cells under microscopes, which is labor-intensive. Automated cell concentration estimation can be achieved using flow cytometers; however, their high cost limits accessibility. Microfluidic systems, although cheaper than flow cytometers, still require high-speed cameras and syringe pumps to drive the flow and ensure video quality. In this paper, we present SmartFlow, a low-cost solution for cell concentration estimation using smartphone-based computer vision on 3D-printed, pump-free microfluidic platforms. OBJECTIVE The objective was to design and fabricate microfluidic chips, coupled with clinical utilities, for cell counting and concentration analysis. We answered the following research questions (RQs): RQ1, Can gravity drive the flow within the microfluidic chips, eliminating the need for external pumps? RQ2, How does the microfluidic chip design impact video quality for cell analysis? RQ3, Can smartphone-captured videos be used to estimate cell count and concentration in microfluidic chips? METHODS To answer the 3 RQs, 2 experiments were conducted. In the cell flow velocity experiment, diluted sheep blood flowed through the microfluidic chips with and without a bottleneck design to answer RQ1 and RQ2, respectively. In the cell concentration analysis experiment, sheep blood diluted into 13 concentrations flowed through the microfluidic chips while videos were recorded by smartphones for the concentration measurement. RESULTS In the cell flow velocity experiment, we designed and fabricated 2 versions of microfluidic chips. The ANOVA test (Straight: F6, 99=6144.45, P<.001; Bottleneck: F6, 99=3475.78, P<.001) showed the height difference had a significant impact on the cell velocity, which implied gravity could drive the flow. The video sharpness analysis demonstrated that video quality followed an exponential decay with increasing height differences (video quality=100e–k×Height) and a bottleneck design could effectively preserve video quality (Straight: R2=0.95, k=4.33; Bottleneck: R2=0.91, k=0.59). Samples from the 13 cell concentrations were used for cell counting and cell concentration estimation analysis. The accuracy of cell counting (n=35, 60-second samples, R2=0.96, mean absolute error=1.10, mean squared error=2.24, root mean squared error=1.50) and cell concentration regression (n=39, 150-second samples, R2=0.99, mean absolute error=0.24, mean squared error=0.11, root mean squared error=0.33 on a logarithmic scale, mean average percentage error=0.25) were evaluated using 5-fold cross-validation by comparing the algorithmic estimation to ground truth. CONCLUSIONS In conclusion, we demonstrated the importance of the flow velocity in a microfluidic system, and we proposed SmartFlow, a low-cost system for computer vision–based cellular analysis. The proposed system could count the cells and estimate cell concentrations in the samples.