Estefanía Requena-Gómez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Estefanía Requena-Gómez has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ana Isabel Serrano-Esteban
Department of Criminal Law and Criminology, International University of La Rioja (UNIR), 26006 Logroño, Spain
1 shared publication - Carolina Larrazábal-Morón
Valencia University Medical and Dental School, Valencia, Spain
1 shared publication - Cinthia Rodríguez
Department of Dentistry, Universidad Federico Henriquez y Carvajal, Santo Domingo 10106, Dominican Republic
1 shared publication - Francisco Javier González
Deparment of Dentistry, Faculty of Medicine and Health Sciences, Universidad Católica de Valencia San Vicente Martir, 46001 Valencia, Spain
1 shared publication - Javier Barberá-Millán
Oral Surgery Unit, Department of Dentistry, Faculty of Medicine and Health Sciences, Catholic University of Valencia San Vicente Mártir, C/Quevedo, 2, 46001 Valencia, Spain
1 shared publication - Jesús Mena-Álvarez
Departments of Conservative Dentistry and Prosthetics, Faculty of Dentistry, Complutense University of Madrid
1 shared publication
Latest Publications
- Open Access
- 14 February 2023
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (2) , 107
Cadaveric Identification through Macroscopic Analysis of Dental Implants Subjected to High Temperatures—An Experimental Model
The aim of this study was to determine the possibility of identifying a dental implant through the measurement of the apical width and the interspiral distance in a periapical radiograph after being subjected to high temperatures for certain lengths of time. In total, 11 fresh human anatomical models were selected, in which 137 implants were placed. Previous periapical radiographs were performed using parallelizers in each implant. Subsequently, the anatomical models were introduced into a crematory oven at different temperatures and for various durations: 500 °C/15 min, 500 °C/30 min, 700 °C/15 min, 800 °C/15 min, 800 °C/45 min, 500 °C/15 min, 700 °C/15 min, and finally, 1000 °C/120 min. After this, X-rays were taken via a parallel technique, and the apical width and interspiral distance were measured. The implants were disinserted, and the coronal width was used to calculate magnification or possible distortion. All data were analyzed by the Mann–Whitney U test. There were no statistically significant differences for the apical width parameter, except when the temperature was raised to 700 °C/15 min and to 800 °C/45 min. For the interspiral distance parameter, there were no statistically significant differences, except when the implants were subjected to 800 °C/15 min and 1000 °C/120 min. It was determined that there were changes in some groups based on the increase in temperature and exposure time. Neither of the two parameters were completely useful for the identification because some of the groups studied in both variables presented differences, which makes them difficult to identify correctly.
- 14 February 2023
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 14 (2) , 107
Open AccessCadaveric Identification through Macroscopic Analysis of Dental Implants Subjected to High Temperatures—An Experimental Model
The aim of this study was to determine the possibility of identifying a dental implant through the measurement of the apical width and the interspiral distance in a periapical radiograph after being subjected to high temperatures for certain lengths of time. In total, 11 fresh human anatomical models were selected, in which 137 implants were placed. Previous periapical radiographs were performed using parallelizers in each implant. Subsequently, the anatomical models were introduced into a crematory oven at different temperatures and for various durations: 500 °C/15 min, 500 °C/30 min, 700 °C/15 min, 800 °C/15 min, 800 °C/45 min, 500 °C/15 min, 700 °C/15 min, and finally, 1000 °C/120 min. After this, X-rays were taken via a parallel technique, and the apical width and interspiral distance were measured. The implants were disinserted, and the coronal width was used to calculate magnification or possible distortion. All data were analyzed by the Mann–Whitney U test. There were no statistically significant differences for the apical width parameter, except when the temperature was raised to 700 °C/15 min and to 800 °C/45 min. For the interspiral distance parameter, there were no statistically significant differences, except when the implants were subjected to 800 °C/15 min and 1000 °C/120 min. It was determined that there were changes in some groups based on the increase in temperature and exposure time. Neither of the two parameters were completely useful for the identification because some of the groups studied in both variables presented differences, which makes them difficult to identify correctly.
- Open Access
- 30 July 2021
- Published by MDPI AG in Dentistry Journal
- Vol. 9 (8) , 84
Adjuvant Effect of Titanium Brushes in Peri-Implant Surgical Treatment: A Systematic Review
Background: the prognosis of peri-implant surgery can be affected by poor decontamination of the implant surface, which could be improved with the use of titanium brushes. The objectives of this systematic review were to evaluate the effectiveness of titanium brushes in the decontamination of the implant surface in terms of plaque index, probing depth, bleeding on probing and bone loss/gain; as well as its effectiveness according to the type of peri-implant bone defect. Methods: an electronic search was carried out in the PubMed, Scopus, Cochrane and Embase databases, as well as a manual search. The search strategy included four keywords: “Peri-implantitis”, “Periimplantitis”, “Implant Surface Decontamination” and “Titanium Brush”. Randomized controlled studies published in the last 10 years were included and systematic reviews, in vitro studies and animal studies were excluded. Results: 142 references were found, from which only four articles met the inclusion criteria. All of the studies included in the present review reported beneficial results in terms of probing depth, gingival index and radiographic bone loss and gain after implant surface decontamination adjuvated by titanium brushes. Conclusions: titanium rotary brushes show improvements in the evolution and prognosis of peri-implant surgery, although more long-term studies are needed to draw more solid conclusions.
- 30 July 2021
- Published by MDPI AG in Dentistry Journal
- Vol. 9 (8) , 84
Open AccessAdjuvant Effect of Titanium Brushes in Peri-Implant Surgical Treatment: A Systematic Review
Background: the prognosis of peri-implant surgery can be affected by poor decontamination of the implant surface, which could be improved with the use of titanium brushes. The objectives of this systematic review were to evaluate the effectiveness of titanium brushes in the decontamination of the implant surface in terms of plaque index, probing depth, bleeding on probing and bone loss/gain; as well as its effectiveness according to the type of peri-implant bone defect. Methods: an electronic search was carried out in the PubMed, Scopus, Cochrane and Embase databases, as well as a manual search. The search strategy included four keywords: “Peri-implantitis”, “Periimplantitis”, “Implant Surface Decontamination” and “Titanium Brush”. Randomized controlled studies published in the last 10 years were included and systematic reviews, in vitro studies and animal studies were excluded. Results: 142 references were found, from which only four articles met the inclusion criteria. All of the studies included in the present review reported beneficial results in terms of probing depth, gingival index and radiographic bone loss and gain after implant surface decontamination adjuvated by titanium brushes. Conclusions: titanium rotary brushes show improvements in the evolution and prognosis of peri-implant surgery, although more long-term studies are needed to draw more solid conclusions.