  • Closed-Form Implicit Models for Efficient Simulation of Power Electronics

    by Andrew S. Wunderlich, Enrico Santi

    This document describes novel closed-form implicit (CF-implicit) models of switched-mode power converters which feature implicit integration but require no iterative numerical solving algorithm for evaluation because they are explicitly solved in closed form prior to model execution. The derived models capture the large-signal dynamic behavior of the power converters, so their use and accuracy are not limited to any one set of operating conditions. These models can be directly implemented in any computational environment, including directly on an existing embedded controller. Since no iterative solver is required, the models are highly computationally efficient and have a very predictable worst-case execution time, which makes them especially suitable for real-time modeling applications like hardware-in-the-loop simulation or digital twins. The model derivation process is demonstrated by example on a two-stage power converter, and computational expense is analyzed. A discussion of model error is also included.


  • Protection Scheme for Fast Detection and Interruption of High-Impedance Faults on Rate-Limited DC Distribution Networks

    by Andrew S. Wunderlich, Daniel Bauer, Enrico Santi, Roger A. Dougal, Andrea Benigni, Rob Bennett, Luis E. Zubieta

    This paper presents a protection scheme for DC power distribution systems based on a unique rate-limited operating mode. The concept of this protection scheme is that extremely slow ramp-rate limits can be imposed on the DC network voltage and on all currents drawn from the network through control of the power electronic interfaces. Meanwhile, all fast transients produced by loads and DGs can be absorbed by local energy storage—typically a battery—behind the interface converter. The removal of all transients from the distribution network enables a very effective method to differentiate normal operation from fault conditions, including high-impedance faults such as vegetation faults and human-body faults. In the proposed scheme, the ramprates of the current and voltage on the network are sensed by each interfaced converter to check for compliance with the defined rate limits. It is unlikely that a given fault on the network will comply with the stringently slow rate limits, so this scheme allows the system to quickly detect the fault and deploy suitable protections. Experimental results show that the presented protection scheme is capable of detecting and interrupting a human-body-impedance fault quickly enough to prevent electrocution on a DC distribution cable operating at voltages of 1000 V and above, leading to unprecedented safety on a power distribution network of this voltage level.